Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

Similar documents
Model No.: outdoor unit U-16GE3E5 U-20GE3E5 U-25GE3E5 U-30GE3E5 U-16GF3E5 U-20GF3E5 U-25GF3E5

WheelieSafe. WheelieSafe. User Manual. Motorized Trolley. Distributor:

C3 Operating Instructions

I. Safety precautions

Oil-free piston compressors KK and piston vacuum pumps KV

USER MANUAL FOR 2000 WATTS POWER INVERTER USER S MANUAL--Read before operating this equipment

Galaxy VM. Battery Breaker Box Installation 09/

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

TOD-BCU-PNUS2. User's Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System)

1100W PORTABLE GENERATOR

Cordless Rechargeable Saw Instructions for Use

Air duct switching damper

Wilo-Control SC-Fire Jockey

Multi-Mover Charger for model L25

OPERATION MANUAL BATTERY CHARGER DFC-10P DFC-50P DFC-450P DFC-650P

Language specific user manuals are available on

R18SPL. ORIGINAL INSTRUCTIONS 18V Dual Power LED Spotlight

BATTERY CHARGER BTC-1005A

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

Manual. Curtis Model 1625 Battery Charger. Curtis Instruments, Inc. 200 Kisco Avenue Mt. Kisco, NY

1200W INVERTER GENERATOR

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

Instruction Manual for Safety and Comfort

Freedom egen System End-of- Line Functional Checklist

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Owner s Information Manual

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

AXIAL FANS Axis / Tubo OPERATION MANUAL

MULTI FUNCTION POWER PAK PLUS

c-go 24V/6A 24V/8A 24V/12A

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

MODEL: AG-HA-950D GENERATOR OWNER S MANUAL

Switching DC Power Supply

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

V3700UK OWNER S GUIDE.

Safety and General Information

MANUAL (EN 7.12) (IEC 7.12 Ed.5)

Owner s Manual & Safety Instructions

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

This page is intentionally blank.

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Smart Charger 12-24V 60A, 1600W

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

PRESSURE BOOSTER 150

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Galaxy 300 Battery Breaker Kit G3HTBKIT1

Battery Power Inverters

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

IMPORTANT SAFETY INSTRUCTIONS

PAC 600 PAC 800 PAC 800 comfort

Sinewave Inverter. HIPHOP pro 1500 HIPHOP pro User s manual

Language specific user manuals are available on

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

Model: SPTOGT01 TRACTOR PTO GENERATOR

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

BRAVER UPS. (Uninterruptible Power System) User s Manual

OPERATION INSTRUCTIONS

SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E. FILE No. A

Installation Instructions for Load Management Kit A051C329

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

3000W POWER INVERTER. User Manual

Battery Unit BHM60PC/BHM100PC Instruction Manual

ATD WATT INVERTER

DIGITAL TEMPERATURE CONTROL

AG-HA-2500N GASOLINE GENERATOR

OPERATION & MAINTENANCE INSTRUCTIONS

Owner s Manual & Safety Instructions

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

720W PORTABLE GENERATOR

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

Energy-Saving Under-Cabinet Light. Assembly and safety advice Z30802A-BS Z30802B-BS

Instruction manual. Electrobloc EBL 269

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

OWNER S MANUAL POWER INVERTER

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Water Dispenser Owner s Manual 100 Series

Electrical Installation

Instruction manual. CSV 402 caravan power supply. Table of contents

ATD WATT INVERTER

S9 SWEEPER PARTS MANUAL

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

RBC-121 Battery Charger and RB-1225 Batteries

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

PowerPlex 40V MAX Standard Battery Pack/Charger

TABLE OF CONTENTS. 300 W Mobile Power Outlet SAVE THESE INSTRUCTIONS!

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

Lumitester PD-20 Control Kit

R18TP. ORIGINAL INSTRUCTIONS 18V Transfer Pump

Transcription:

Modbus Interface DIII EKMBDXA7V1 Modbus Interface DIII English

379 mm 0 C 100 mm 50 mm 50 mm 40 mm 87 mm 300 mm IP X0 50 mm 60 C 365 mm 124 mm Max. 100 mm Min. 1 2 3 1 www.daikineurope.com/support-and-manuals/product-information/ Design guide X3M RS485 BMS X1M A+ B- D UNIT/ F1 TO OUT F2 L N L N RS485 0.75~1.25 mm2 MAX 500 m 1x 1x Q1DI UNIT 2 F1 F2 L 1N~ 50 Hz 230 V AC 0.75~1.25 mm2 2 3 1

1 Introduction 1 Introduction See the illustrations at the beginning of this manual. 2 General safety precautions 2.1 About the documentation The original documentation is written in English. All other languages are translations. The precautions described in this document cover very important topics, follow them carefully. All activities described in the installation manual must be performed by an authorized installer. 2.1.1 Meaning of warnings and symbols DANGER Indicates a situation that results in death or serious injury. DANGER: RISK OF ELECTROCUTION Indicates a situation that could result in electrocution. Indicates a situation that could result in death or serious injury. CAUTION Indicates a situation that could result in minor or moderate injury. Indicates a situation that could result in equipment or property damage. INFORMATION Indicates useful tips or additional information. 2.2 For the user If you are not sure how to operate the unit, contact your installer. The appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children must be supervised to ensure that they do not play with the product. CAUTION Do NOT rinse the unit. This may cause electric shocks or fire. Do NOT place any objects or equipment on top of the unit. Do NOT sit, climb or stand on the unit. 2.3 For the installer 2.3.1 General If you are not sure how to install or operate the unit, contact your dealer. Improper installation or attachment of equipment or accessories could result in electric shock, short circuit, leaks, fire or other damage to the equipment. Only use accessories, optional equipment and spare parts made or approved by Daikin. Make sure installation, testing and applied materials comply with applicable legislation (on top of the instructions described in the Daikin documentation). CAUTION Wear adequate personal protective equipment (protective gloves, safety glasses, ) when installing, maintaining or servicing the system. Tear apart and throw away plastic packaging bags so that nobody, especially children, can play with them. Possible risk: suffocation. Provide adequate measures to prevent that the unit can be used as a shelter by small animals. Small animals that make contact with electrical parts can cause malfunctions, smoke or fire. Do NOT place any objects or equipment on top of the unit. Do NOT sit, climb or stand on the unit. In accordance with the applicable legislation, it might be necessary to provide a logbook with the product containing at least: information on maintenance, repair work, results of tests, stand by periods, Also, at least, following information must be provided at an accessible place at the product: Instructions for shutting down the system in case of an emergency Name and address of fire department, police and hospital Name, address and day and night telephone numbers for obtaining service In Europe, EN378 provides the necessary guidance for this logbook. 2.3.2 Installation site Provide sufficient space around the unit for servicing and air circulation. Make sure the installation site withstands the unit s weight and vibration. Make sure the area is well ventilated. Make sure the unit is level. Make sure that the floor, where the unit will be installed, is level. EKMBDXA7V1 Modbus Interface DIII 4P357730 1 2014.04 3

2 General safety precautions Do NOT install the unit in the following places: In potentially explosive atmospheres. In places where there is machinery that emits electromagnetic waves. Electromagnetic waves may disturb the control system, and cause malfunction of the equipment. In places where there is a risk of fire due to the leakage of flammable gases (example: thinner or gasoline), carbon fibre, ignitable dust. In places where corrosive gas (example: sulphurous acid gas) is produced. Corrosion of copper pipes or soldered parts may cause the refrigerant to leak. In bathrooms. In places where frost is possible. The ambient temperature around the indoor unit should be >5 C. 2.3.3 Electrical DANGER: RISK OF ELECTROCUTION Turn OFF all power supply before removing the switch box cover, connecting electrical wiring or touching electrical parts. Disconnect the power supply for more than 1 minute, and measure the voltage at the terminals of main circuit capacitors or electrical components before servicing. The voltage MUST be less than 50 V DC before you can touch electrical components. For the location of the terminals, see the wiring diagram. Do NOT touch electrical components with wet hands. Do NOT leave the unit unattended when the service cover is removed. If NOT factory installed, a main switch or other means for disconnection, having a contact separation in all poles providing full disconnection under overvoltage category III condition, shall be installed in the fixed wiring. ONLY use copper wires. All field wiring must be performed in accordance with the wiring diagram supplied with the product. NEVER squeeze bundled cables and make sure they do not come in contact with the piping and sharp edges. Make sure no external pressure is applied to the terminal connections. Make sure to install earth wiring. Do NOT earth the unit to a utility pipe, surge absorber, or telephone earth. Incomplete earth may cause electrical shock. Make sure to use a dedicated power circuit. NEVER use a power supply shared by another appliance. Make sure to install the required fuses or circuit breakers. Make sure to install an earth leakage protector. Failure to do so may cause electric shock or fire. When installing the earth leakage protector, make sure it is compatible with the inverter (resistant to high frequency electric noise) to avoid unnecessary opening of the earth leakage protector. Install power cables at least 1 meter away from televisions or radios to prevent interference. Depending on the radio waves, a distance of 1 meter may not be sufficient. After finishing the electrical work, confirm that each electrical component and terminal inside the electrical components box is connected securely. Make sure all covers are closed before starting up the unit. Only applicable if the power supply is three phase, and the compressor has an ON/OFF starting method. If there exists the possibility of reversed phase after a momentary black out and the power goes on and off while the product is operating, attach a reversed phase protection circuit locally. Running the product in reversed phase can break the compressor and other parts. 2.4 Glossary Dealer Sales distributor for the product. Authorized installer User Technical skilled person who is qualified to install the product. Person who is owner of the product and/or operates the product. Applicable legislation All international, European, national and local directives, laws, regulations and/or codes that are relevant and applicable for a certain product or domain. Service company Qualified company which can perform or coordinate the required service to the product. Instruction manual specified for a certain product or application, explaining how to install, configure and maintain it. Operation manual Accessories Instruction manual specified for a certain product or application, explaining how to operate it. Labels, manuals, information sheets and equipment that are delivered with the product and that need to be installed according to the instructions in the accompanying documentation. Optional equipment Field supply Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Equipment not made by Daikin that can be combined with the product according to the instructions in the accompanying documentation. 4 EKMBDXA7V1 Modbus Interface DIII 4P357730 1 2014.04

4P357730-1 0000000N Copyright 2014 Daikin 4P357730 1 2014.04