Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

Similar documents
CHAPTER V RESIDENTIAL WIRING

Learning Module 10: Loadcenters. 101 Basic Series

Chapter 4 Utility Systems Electrical

Is Your Wiring System Safe and Energy Efficient?

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

METERING REQUIREMENTS

Service Entrance Methods

UNDERSTANDING ELECTRICAL EQUIPMENT AND CONDITIONS OF INCREASED RISK

TRANSMISSION SYSTEMS

ADVANCED CALCULATIONS

PROTECTION OF THE BRANCH CIRCUIT

Pretest Module 24 Three-phase Service Entrance

UPFRO. Residential Electric. Voltage & Amperage

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

DIY 15 Amp Portable Generator Transfer Switch

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

Alternating Current (AC) Electricity

More Complex Circuit

Circuit Concepts (Residential)

Electric Vehicle Charging Station Article California Electrical code (CEC) General Requirements:

INSTALL CIRCUIT PROTECTIVE DEVICES

INSTALLATION INSTRUCTIONS

Section 6 Electric Metering: Residential

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

Home Electrical Wiring. Getting the electricity from the main power lines to a location in the house

INSTALLATION AND OPERATING INSTRUCTIONS

SINGLE PHASE WIRING SPECIFICATIONS

THREE PHASE WIRING SPECIFICATIONS

Understanding Electrical Terms

Overcurrent Protection According to the 2011 NEC

Calculating AC Line Voltage Drop for M215 Microinverters with Engage Cables

Supply-Side PV Connections

Electrical ELECTRICAL

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

INSTALLATION & OPERATION MANUAL

FACT SHEET Standard: Electrical Safety

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

What is included in a circuit diagram?

MASTERsine Inverter PXA Series Installation Guide

A PHEV is a hybrid vehicle with batteries that can be recharged by connecting a plug to an external power source.

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

ATLAS Wheel Balancer Electrical Flow Chart

EVSE Load Balancing VS Load Shedding 1: Largest number of 30 Amps EVSEs that can be fed as per the code from the 600 volts feeder

Electric Vehicle Charging Station Article California Electrical code (CEC) General Requirements:

Electrical Safety. Introduction

EXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

Electric Vehicle Appendix Notes

Electrical Equipment and Terminology

Spring Test 7 due 05/03/2013

Overcurrent protection

Plan Ahead or Bust the Electric Budget

Electricity Electric Current current. ampere. Sources of Current

OPERATION AND INSTRUCTION MANUAL. EP Series. Battery Chargers and Power Supplies

OVERLOAD PROTECTION. All electrical circuits must have some means of protecting against overload.

(The actual state exam will be closer to 50 questions in 4 hours time) Master Electrician Practice Test

Electricity Notes 3. Objectives

CLIF NOTES SERIES (Competent Leveraging of Information and Facts) ELECTRICAL

ELECTRICAL. 60 Minutes

Choosing Household Wiring for Low EMF

30A SMART ENERGY MANAGEMENT SYSTEM TM

Assessing a Site for Installation of Consumption Monitoring

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Building Operator Certification Level I

Spring Test 10 due 05/11/2013

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

Overcurrent Protection (2014 NEC) (Homestudy)

3.1 Overview of ATCO Electric s URD System Design

8300 Series Installation Guidelines

Metering and Service Installation:

SIGNAL WORDS QUALIFIED PERSON

Electrical Maintenance and Repair: Introduction to Basic Electricity

OCEAN COUNTY ARES EMERGENCY GENERATOR USE By WX2NJ. The following was taken from September and October Ocean County ARES Newsletters in 2012:

Ten Deadly Conditions to Check for in Your Boat's Electrical System - Part 2

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.

ECET Distribution System Protection. Overcurrent Protection

Customer Requirements Downtown Secondary Network Service

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

Effective discrimination of protective devices

ELVORON HOME ELEVATOR

Electricity 1

Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

INSTALLATION INSTRUCTIONS

Electrical Circuits Discussion Questions:

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Standby Electric Generators for Alaskan Residences. Advice & Installation

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

Grounding Of Standby & Emergency Power Systems

Electrical Depth. Josh Kreutzberger Lighting/Electrical

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

EV Charging Station Submittal Requirements

Installation and Construction Notes for EVSE4

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

18.5. Electrical Circuits and Safety

Transcription:

Electric Drive Vehicle Infrastructure Training Instructor s Manual National Alternative Fuels Training Consortium

Part 4: : Service Panel to Receptacle Overview of Service Panel The role of the service panel is to distribute power throughout the home or building as well as disconnect the power from any incoming electrical feed. It is the only location inside of the home where all of the electrical power can be shut off all at once. The service panel, also called the electric panel, breaker box or fuse box, is both the entry and distribution points for all of the circuits. All branch circuits go to the home or building s outlets/receptacles, switches and appliances from this service panel. PPT 4-14? Review Question No. 6 There is typically only one service panel that feeds electricity to the entire home or building location. However, subpanels may be installed to serve a garage or other outside need. The service panel provides the ability to access all of the circuit breakers that are stacked within the panel. On the side of the service panel door is usually an outlined document or sticker identifying each circuit breaker to indicate the relative appliance or circuit it serves. It also will note any unused breaker space. Service Panel Amperage Sizes Typical service panel amperage sizes are: 100 amps 150 amps 200 amps 400 amps PPT 4-15 The service panel amperage sizes vary for different locations. For individual residences, amperage sizes would include 100amps, 150amps, 200amps, and 400amps for larger electric-powered homes. For apartment building and multi-unit dwellings, typical amperage sizes would be 60amps to 100amps for each individual apartment or dwelling. For business and commercial locations, amperage sizes vary greatly. The range in amperage sizes could be from 60amps to 800amps, as the electricity needed could be to support an individual office or a warehouse, heavy duty electrical equipment, or other commercial process requiring large amounts of power. The amperage size will depend on whatever is needed to supply the business loads. The business location may be on a single phase or multiple phase system depending upon the load needed to support the purposes of the business. 4-13

It is important to adhere to safety regulations required for the space and clearance around service panels. In an emergency, a service panel must always be readily accessible in order to be able to shut off the electricity to the home or business. The service panel cannot be obstructed by another object in front of it or on the side of it that can restrict the opening of the service panel door. The required clearance and space around the service panel is 3 foot deep, by 2.5 feet wide, by 6.5 feet in height. PPT 4-16 Older and Outdated Service Panels More than half of homes today were constructed before 1970 and were built decades before some of the more modern electrical conveniences. In some of these homes, they will have no more than 60amp electrical service. Unless the older home s electrical service has been upgraded, it is most likely being electrically overburdened and cannot safely handle the electric demands of today s electrical devices. Some examples of older and outdated service panels include fuse boxes, Federal Pacific Electric panels, and Zinsco panels. Fuse boxes used to be the most common type of circuit protection before World War II. Fuse boxes still exist in many older homes even though they are quite old. Two of the most common types of fuses for the fuse box are plug/glass fuses and cartridge fuses. The Federal Pacific Electric Panels have problems in failing to provide proper safety and protection for homes. Some of the problems included breakers failing to trip forcing an overcurrent, and short circuits overheating and causing fires. Whenever this type of panel is found within a house, it is recommended that a new service panel be installed. There are also difficulties with the Zinsco panels as well, as they also have historically failed to operate properly. The Zinsco panels have show to overheat and melt in certain scenarios when an increase in electrical demand was placed on it. It is important to note that whenever these types of older and outdated service panels are identified, they should have a new service panel installed by a certified electrician as well as their electrical service upgraded by their utility company. The content in this manual will be focused on up to date service panels utilizing circuit breakers. 4-14 Benefit of New Service Panels As the electricity from the electric meter must enter the home or location, it is beneficial to have the service panel mounted back to back with the electric meter. This design saves on the installation expense on running cable, as well as installing a second cutoff panel near the electric meter base, which is required by most electrical codes.

Circuit Size Needed 125% Continuous Load Appropriate AWG Size Circuit Breaker Size 15 amps (18.75) 20amps 12 AWG 20 amps 25 amps 10 AWG 25 amps (31.25) 30-40amps 10 or 8 AWG 30 amps (37.4) 40amps 8 AWG 35 amps (43.75) 50 amps 8 AWG 40 amps 50 amps 8 AWG 45 amps (56.25) 60 amps 6 AWG 50 amps (62.5) 65 amps 6 AWG 60 amps 75 amps 4 AWG 70 amps (87.5) 90 amps 3 AWG 80 amps 100 amps 3 AWG 90 amps (112.5) 115 amps 2 AWG 100 amps 125 amps 1 AWG 110 amps (137.5) 140 amps 1/0 AWG 125 amps (156.25) 160 amps 2/0 AWG 150 amps (187.5) 190 amps 3/0 AWG 175 amps (218.75) 220 amps 4/0 AWG 200 amps 250 amps 250 AWG 225 amps (281.25) 285 amps 300 AWG 250 amps (312.5) 320 amps 400 AWG Circuit Review PPT 4-31 The following will provide an overview of the journey of the circuit. Circuits originate at the service panel that houses electricity provided by the two thick hot wires. The black hot wires are attached to the two hot bus bars, and one neutral wire is attached to the neutral bus bar. These three wires originate from the electric meter (it is important to remember that there is also the ground bus bar as well in the service panel). Depending upon the amount of electricity a circuit needs to deliver, the circuit may attach to one hot bus bar and the neutral bus bar to supply 120 volts of electricity, or to both hot bus bars for 240 volts of electricity. The means of attachment for a circuit to the hot bus bars, neutral bus bar and ground bus bar are through the circuit breaker. As we have discussed, the circuit breaker protects the circuit from surges in the current. Neutral conductors are connected to the ground bus bar or to a grounding wire which renders the neutral wires to be grounded. Unlike the hot bus bars, the neutral bus bar does not have an overcurrent protection device; i.e. circuit breaker. The neutral wire can maintain 0 volts at all times. A circuit s journey begins and ends all at the same place. A loop is a useful analogy when understanding the circuit s path. The current begins at a power source. It then powers the appliance or device along the circuit (remember the loop analogy) and then returns to the power source. 4-24

A review of the pathway and flow of electricity through the home can described with the following description. Electricity passes through the utility transformer outside the home, and leaves the transformer through three wires ( two hot and one neutral). The three wires constitute a service drop, which is a voltage stepped down by the utility transformer to the amount of voltage needed for the home. The service drop travels to the home, either above or below ground. The wires go to the house and down the service entrance conduit to the electric utility meter (which records and keeps track of the electrical activity). The wires from the electric meter continue to the service panel, where the two hot wires are fed to the 2 hot bus bars and the grounded neutral wire is fed to the neutral bus bar. The service panel contains circuit breakers which are connected to the two hot bus bars and wired to the neutral bus bar. The circuit breakers distribute current through circuit wiring within the home and then the current is returned to the panel through the neutral white wire. From here, the electricity that has been returned to the service panel then travels back through the electric utility meter which it is measured and back to the utility transformer. Electricity can never actually be consumed, you only borrow it. You transform much of its energy though and that is what you pay for to the utility company. Branch Circuits Each of the circuit breakers in the service panel controls electricity on a branch circuit. It is a loop of wire that runs from the service panel, out to the receptacles where the appliances are plugged in and then back to the panel. Dedicated Branch Circuits A dedicated branch circuit means that the circuit is dedicated to one particular device. The circuit has its own circuit breaker and it is intended for a single use and will power only one specific outlet or device. This type of circuit is designed to ensure that the circuit is used to power the specific appliance will not be overloaded, the power supply will be uninterrupted, and the operating conditions will remain safe. The dedicated circuit is mostly used for large appliances such as a range, water heater, air conditioner, and clothes dryer. This type of circuit can be either 120 volts or 240 volts. PPT 4-32? Review Question No. 11 Hardwired Hardwired refers to appliances and devices that are wired directly to the circuit wires. They are not connected through a receptacle, but rather the circuit supplies electricity to the appliance directly through its direct connection with the appliance. Receptacles Receptacles are commonly referred to as outlets that are used to provide an individual appliance or device a place to plug in for power distribution. Residential housing frequently uses 120 volts, 15amp and 20amp receptacles (outlets) for household equipment. Also included in residential housing are receptacles providing appliances with 240 volt and 30amp service. 4-25 PPT 4-33