Quick selector reference guide. Motor Control Center Aftermarket Buckets

Similar documents
Lightning Fast Service!

Motor Control Centers

SIGNAL WORDS QUALIFIED PERSON

Section 17. Motor Control Centers. Table of Contents. Model 6 Motor Control Centers

For Options, Modifications and Accessories, see pages Discount Schedule A6

Multi-Pak Group Control

Enclosures. See Section Typical Description

RotoTract Remote Racking Operating Manual

3. Coils shall be of molded construction

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

(337) FAX

NEMA Vacuum Break Contactors and Starters

Plug and Play Kit Installation and Wiring (Non-Combo and Combo)

Ampgard The name motor applications rely on

Ampgard medium voltage motor control renewal parts

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

WARREN COUNTY, N.Y. M/E REFERENCE

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

Features, Benefits and Functions

SECTION MOTOR CONTROL

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Motor Control Centers (MCC) Identification Guide. Answers for industry.

Autodesk Inc. CB (Circuit Breakers): Following series contents are added/updated. CR (Control Relays) Following series contents are added.

Evolution * Series E9000 Motor Control Center

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

SECTION ENCLOSED CONTROLLERS

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Softstarters Type PSS. Softstarters. General information

Generator Fire Safety: Generator assemblies should be located outside the building.

SECTION MOTORS & MOTOR CONTROLLERS

CUTLER HAMMER 200 AMP TRANSFER SWITCH MANUAL

Model 6 Motor Control Centers Catalog 8998CT9701R07/ Class 8998

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

Enclosed Full-Voltage Starters

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

EBMC Combination Line Starters and Enclosures

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

TA Ta VA CTRL-XFRMR

and legacy Motor Control Center Aftermarket Renewal Parts Catalog

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Enclosed Full-Voltage Starters

SECTION PANELBOARDS

NEMA Contactors & Starters (Freedom)

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Motor Control Centres

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Reduced Voltage Motor Starters

Industrial Control Transformers

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Standard Materials Bodies and covers: copper-free aluminum.

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K

Cutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

Application Description

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

MANUAL STARTERS AND SWITCHES EBOOK

Freedom FlashGard Aftermarket Kit Installation Manual

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

Installation and Construction Notes for EVSE4

Design Standard. Purpose: Design Standard:

How to select the correct size DS7 soft start controller

For Options, Modifications and Accessories, see pages Discount Schedule A6

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

XT IEC Power Control Manual Motor Protectors

Quick selector reference guide. Pow-R-Stock panelboards, safety switches, and transformers

Industry s most comprehensive medium voltage circuit protection

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Medium Voltage Metal-Enclosed Switches

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

MAGNETIC MOTOR STARTERS

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

CWM_N NEMA Rated Contactors

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Industry Automation Control Components

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

Basics of Medium Voltage Motor Control Starter Power Components & Starter Types

Bolted contact switches. Pringle switches

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Starting of Induction Motors

Medium Voltage Metal-Enclosed Switches

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Mining service breakers with true rms sensing designed specifically for trailing cable applications

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Transcription:

Quick selector reference guide Motor Control Center Aftermarket Buckets

2 EATON WWW.EATON.COM/MCCAFTERMARKET

Table of contents Series 2100 MCC bucket Motor Control Center (MCC) Aftermarket Buckets Overview Product contact information... 4 Questions to ask... 5 MCC selection & sizes... 6-7 Catalog numbering (Aftermarket MCC Starter Buckets)... 8 Aftermarket MCC Starter types... 9 Catalog numbering (Aftermarket MCC Feeder Buckets/)...10 Common modifications...11 EatonT MCC designs FlashGardT...12 IT. MCC...13 Freedom 2100 (F2100)...14 Cutler-HammerT MCC designs Freedom UnitrolT...15 F10 Unitrol...16 9800 Unitrol...17 WestinghouseT MCC designs Advantage...18 Series 2100/5 Star...19 Type W...20 11-300...21 Other manufacturer MCC designs ITE/GouldT (5600 Series)...22 General ElectricT (7700/8000)...23 Allen-BradleyT (Centerline Series K and later)...24 SiemensT/FurnasT (Series 89)...25 Square DT (Model 4/ Model 5/ Model 6)...26 MoellerT (Series 90, 100, 170, 200, 3000 and Modan 3000)...27 FPET (5325/5320)...28 Support services MCC Aftermarket selling tips... 29 Product & service locations... 30 MCC terminology... 31 EATON WWW.EATON.COM/MCCAFTERMARKET 3

Product contact information Call: 1-800-OLD-UNIT (1-800-653-8648) Notes: 4 EATON WWW.EATON.COM/MCCAFTERMARKET

Questions to ask Step 1 Step 2 Step 3 Q Q Q Q Q Q Q Q What type of MCC do you need? A Please reference photos on page 7 to select correct vintage What type of bucket do you require? A Starter unit (go to step 2) Feeder unit (go to step 3) What type of disconnect do you need? A HMCP/ What type of starter do you require? A FVNR (Full-voltage non-reversing) FVR (Full-voltage reversing) What is your starter size? A See chart on page 9 for selection What modifications do you need? A See chart on page 11 for common modifications What type of disconnect do you require? A Circuit breaker switch What amperage do you need? A See catalog numbering on page 10 for available sizes EATON WWW.EATON.COM/MCCAFTERMARKET 5

MCC selection & sizes Eaton Motor Control Centers Aftermarket products and services Table for identifying Motor Control Center types MCC Type Type of Handle Mechanism 11-300 Rotary 11-200 Life Line Type N 9800 Unitrol Rotary and Lever Type W Slider A200 or 11-200 F10 Unitrol Freedom Unitrol Series 2100/ 5 Star Slider and Lever Slider Starter Type Bucket Width (Inches) Door Width (Inches) 15-3/4 20 21 3 Star 16-1/8 19-3/8 17 11-3/4 13-3/8 20 Citation 14 14-3/4 with Wireway Freedom Series 19-1/2 without Wireway Page Number 16 13-7/8 15-1/2 15 Lever A200 13-3/4 15-5/8 19 Advantage Lever Advantage 13-3/4 15-5/8 18 Freedom 2100 Lever Freedom Series 13-3/4 15-5/8 14 IT. MCC Rotary IT.-EM 13-3/4 15-5/8 13 FlashGard Rotary Freedom Series Note: See photos on page 7 to identify the vintage. 13-3/4 15-5/8 12 In the event that the nameplate is missing, it is possible to identify the MCC design by the type of handle mechanism, starter type, bucket width and door width. Contact 1-800-OLD-UNIT (1-800-653-8648). 6 EATON WWW.EATON.COM/MCCAFTERMARKET

MCC type 11-300 9800 Unitrol Type W F10 Unitrol Freedom Unitrol Series 2100/5 Star Advantage Freedom 2100 FlashGard MCC Identification by original handle mechanism Freedom 2100, Advantage, Series 2100/5 Star Freedom Unitrol F10 Unitrol Slider F10 Unitrol Lever Type W 9800 Unitrol 11-300 IT. Handles EATON WWW.EATON.COM/MCCAFTERMARKET 7

Catalog numbering system Aftermarket MCC Starter Buckets FZ 206E E A S C12 P57 MCC Type Catalog Codes FZ = Freedom 2100 FK = Advantage FS = Series 2100/5 Star FD = Freedom Unitrol FR = F10 Unitrol FT = Type W FN = 9800 Unitrol FJ = 11-300 FM = IT. SZ = FlashGard GD = ITE 5600 GE = GE 7700/8000 AB = Allen-Bradley Centerline SQ = Square D Model 4, 5, 6 SS = Furnas 89 Starter Type See tables on Page 9 Service Voltage A = 120V B = 208V C = 240V D = 380V E = 480V F = 575V Control Voltage A = 120V B = 208V C = 240V D = 380V E = 480V F = 575V Space Option Code S = Standard height C = Compact X = Oversized CPT C10 = Separate Source Control Fuse C12 = 100VA for sz. 1 2 C13 = 150VA for sz. 3 4 Modification Codes See Page 11 8 EATON WWW.EATON.COM/MCCAFTERMARKET

Aftermarket MCC Starter types Full-Voltage Non-reversing Combination Starter HMCP Disconnect NEMA Size Maximum Horsepower 208V 240V 380V 480V 600V HMCP Size Starter Class Code 1.50.33 1 1 1.50 3 Amp 206A 1 1 1 2 3 3 7 Amp 206B 1 3 3 5 7.50 7.50 15 Amp 206C 1 7.50 7.50 10 10 15 30 Amp 206D 2 10 15 25 25 30 50 Amp 206E 3 25 30 50 50 50 100 Amp 206H 4 40 50 75 100 100 150 Amp 206L Full-Voltage Reversing Combination Starter HMCP Disconnect NEMA Size Maximum Horsepower 208V 240V 380V 480V 600V HMCP Size Starter Class Code 1.50.33 1 1 1.50 3 Amp 216A 1 1 1 2 3 3 7 Amp 216B 1 3 3 5 7.50 7.50 15 Amp 216C 1 7.50 7.50 10 10 15 30 Amp 216D 2 10 15 25 25 30 50 Amp 216E 3 25 30 50 50 50 100 Amp 216H 4 40 50 75 100 100 150 Amp 216L Full-Voltage Non-reversing Combination Starter Disconnect NEMA Size Maximum Horsepower 208V 240V 380V 480V 600V Fuse Size Starter Class Code 1 7.50 7.50 10 10 15 30 Amp 204D 2 10 15 25 25 30 50 Amp 204E 3 25 30 50 50 50 100 Amp 204H 4 40 50 75 100 100 150 Amp 204L Full-Voltage Reversing Combination Starter Disconnect NEMA Size Maximum Horsepower 208V 240V 380V 480V 600V Fuse Size Starter Class Code 1 7.50 7.50 10 10 15 30 Amp 214D 2 10 15 25 25 30 50 Amp 214E 3 25 30 50 50 50 100 Amp 214H 4 40 50 75 100 100 150 Amp 214L EATON WWW.EATON.COM/MCCAFTERMARKET 9

Catalog numbering system Aftermarket MCC Feeder Buckets/ FZ F 1 D S 12 MCC Type Catalog Codes FZ = Freedom 2100 FK = Advantage FS = Series 2100/5 Star FD = Freedom Unitrol FR = F10 Unitrol FT = Type W FN = 9800 Unitrol FJ = 11-300 FM = IT. SZ = FlashGard GD = ITE 5600 GE = GE 7700/8000 AB = Allen-Bradley Centerline SQ = Square D Model 4, 5, 6 SS = Furnas 89 Device Type F = HFD J = HJD K = HKD L = HLD Z = Switch Unit Type 1 = Single Disconnect 2 = Dual Disconnect Trip or Clip Rating (Left Feeder) A = 15 B = 20 C = 25 D = 30A E = 40 F = 50 G = 60A H = 70 J = 80 K = 90 L = 100A Trip or Clip Rating (Right Feeder) Dual Unit Only M = 125 N = 150 P = 175 Q = 200A R = 225 S = 250 T = 300 W = 350 X = 400A Y = 500 Z = 600A Unit Size 12 = 12 14 = 14 18 = 18 or 18-2/3 24 = 24 28 = 28 30 = 30 36 = 36 48 = 48 A Disconnect Sizes 10 EATON WWW.EATON.COM/MCCAFTERMARKET

Common modifications Abbreviated list of common modification codes Note: Please contact your local Service Center for all available modifications and to learn which modifications will work for your aftermarket needs. Modification Codes B10 B11 B19 C10 C11 C12 C13 C18 M12 M16 O19 O20 P10 P11 P15 P16 P20 P32 P35 P36 P38 P41 P50 P53 P55 P56 P57 P58 P59 P60 P61 R24 S11 S22 T10 U10 U11 U14 U17 Option Description Shunt Trip 120V Auxiliary Switch 1NO/1NC Auxiliary Switch 2NO/2NC Control fuse wired for separate source in lieu of CPT Control fuse/disconnect for separate source in lieu of CPT CPT 100VA for size 1 and 2 starters, fused CPT 150VA for size 3 and 4 starters, fused Full capacity CPT for size 5 starters, fused Mini Elapsed Time Meter IQ-200 Meter with 3 CTs Overload Relay Heater/Heater Pack C440 Solid-State Overload Relay Red RUN Light Green STOPPED Light Red RUN Push-to-Test Light Green STOPPED Push-to-Test Light Special Function Light START/STOP Pushbutton ON/OFF Pushbutton FORWARD/REVERSE/STOP Pushbutton FAST/OFF/SLOW Pushbutton Special Function Pushbutton ON-OFF Selector Switch START-STOP Selector Switch FORWARD-REVERSE Selector Switch Special Function 2-Position Selector Switch HAND-OFF-AUTO Selector Switch LOCAL-OFF-REMOTE Selector Switch FAST-OFF-SLOW Selector Switch HIGH-OFF-LOW Selector Switch Special Function 3-Position Selector Switch D15 4-Pole Control Relay 1NO-1NC Starter Auxiliary Contacts 2NO-2NC Starter Auxiliary Contacts Pull-Apart Type Terminal Blocks (Standard on all Vintages except Type W and 11-300) Surge Suppressor on Coil Type SIS Control Wire Wiremarkers Sleeve Type on all Control Wire Wiring Diagram Inside Starter Unit Door EATON WWW.EATON.COM/MCCAFTERMARKET 11

Eaton MCC designs Compatible with 1981 Present Vintages of Freedom 2100, Series 2100/5 Star and Advantage only. Eaton FlashGard 2008 Present NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 CallA 1 5 CallA FVR 1 5 CallA 1 5 CallA IT. Soft Starters 10 200 hp CallA 10 200 hp CallA 2-Speed 1 Winding 1 4 CallA 1 4 CallA 2-Speed 2 Winding 1 4 CallA 1 4 CallA RVAT 2 4 CallA 2 4 CallA Part Winding 1 4 CallA 1 4 CallA Wye Delta 2 4 CallA 2 4 CallA Feeder : 15 400 Amps : 30 400 Amps supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. Complete upgrade kit 12 EATON WWW.EATON.COM/MCCAFTERMARKET

Eaton IT. MCC 2002 Present NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 CallA* 1 5 CallA* FVR 1 5 CallA 1 5 CallA 2-Speed 1 Winding 1 4 CallA 1 4 CallA 2-Speed 2 Winding 1 4 CallA 1 4 CallA IT. Soft Starters 10 200 hp CallA 10 200 hp CallA Feeder : 15 600 Amps : 30 400 Amps Note: 600 Amp units are fixed mounted. supplied with UL label Note: IT. components have reached end-oflife status. Please contact Eaton MCC Aftermarket for replacement options. Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. EATON WWW.EATON.COM/MCCAFTERMARKET 13

Eaton Freedom 2100 (F2100) 1994 Present NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 6 36 1 5 6 60 FVR 1 5 18 60 1 4 24 54 2-Speed 1 Winding 1 4 24 36 1 4 24 60 2-Speed 2 Winding 1 4 24 30 1 4 24 54 Autotransformer 2 4 36 48 2 4 36 72 Part Winding 1 4 24 36 1 4 24 54 Wye Delta Open 2 4 42 60 2 4 30 72 Wye Delta Closed 2 4 42 60 2 4 30 72 Non-reversing Vacuum 4 5 36 48 IT. Soft Starters 10 200 hp 12 36 Feeder : 15 600 Amps : 30 600 Amps Note: 600 Amp units are fixed mounted. supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. 14 EATON WWW.EATON.COM/MCCAFTERMARKET

Cutler-Hammer MCC designs Cutler-Hammer Freedom Unitrol 1988 1994 NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 6 48 1 5 6 72 FVR 1 5 18 72 1 4 18 48 2-Speed 1 Winding 1 5 24 72 1 4 24 60 2-Speed 2 Winding 1 5 24 72 1 4 24 60 Autotransformer 2 5 48 72 2 4 48 72 Part Winding 1 5 24 72 1 4 24 60 Wye Delta Open 2 5 30 72 2 5 30 72 Wye Delta Closed 2 5 36 72 2 4 30 72 IT. Soft Starters 10 200 hp 18 36 Feeder : 15 600 Amps : 30 600 Amps Note: 400 Amp units and above are cable in/out. No stabs are provided. supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. EATON WWW.EATON.COM/MCCAFTERMARKET 15

Cutler-Hammer F10 Unitrol 1972 1989 NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 12 48 1 4 12 36 FVR 1 4 18 36 1 4 18 42 2-Speed 1 Winding 1 4 24 42 1 4 24 48 2-Speed 2 Winding 1 4 18 36 1 4 18 42 Part Winding 1 3 18 30 1 3 18 42 Wye Delta Open 2 4 24 48 2 4 30 60 Wye Delta Closed 2 5 30 72 2 3 36 48 IT. Soft Starters 10 200 hp 18 48 Feeder : 15 400 Amps : 30 400 Amps Note: 400 Amp units and above are cable in/out. No stabs are provided. supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. 16 EATON WWW.EATON.COM/MCCAFTERMARKET

Cutler-Hammer 9800 Unitrol 1956 1974 NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 9 42 1 4 14 42 FVR 1 4 18-2/3 42 1 4 28 56 2-Speed 1 Winding 1 4 28 56 1 3 28 42 2-Speed 2 Winding 1 4 28 42 1 4 28 56 Part Winding 1 3 28 42 1 3 28 56 IT. Soft Starters 10 200 hp 18 42 Feeder : 15 400 Amps : 30 400 Amps Note: 400 Amp units and above are cable in/out. No stabs are provided. supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. EATON WWW.EATON.COM/MCCAFTERMARKET 17

Westinghouse MCC designs Westinghouse Advantage 1991 Present NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 6 36 1 5 6 54 FVR 1 5 18 60 1 4 24 48 2-Speed 1 Winding 1 4 24 36 1 4 24 54 2-Speed 2 Winding 1 5 24 72 1 4 24 48 Autotransformer 2 4 36 48 2 4 36 72 Part Winding 1 4 24 36 1 4 24 48 Wye Delta Open 2 4 30 42 2 4 36 60 Wye Delta Closed 2 4 48 60 2 4 54 72 IT. Soft Starters 10 200 hp 12 36 Feeder : 15 600 Amps : 30 600 Amps supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. Note: In addition to size and spacing, many Advantage components have reached end-of-life status. Please contact Eaton MCC Aftermarket for replacement options. 18 EATON WWW.EATON.COM/MCCAFTERMARKET

Westinghouse Series 2100/5 Star 1975 1994 NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 12 36 1 5 12 60 FVR 1 5 18 54 1 5 18 72 2-Speed 1 Winding 1 5 18 42 1 4 18 54 2-Speed 2 Winding 1 5 18 54 1 4 18 54 Autotransformer 2 5 36 72 2 4 36 72 Part Winding 1 5 18 72 2 4 24 54 Wye Delta Open 2 5 30 72 2 4 30 72 Wye Delta Closed 2 5 30 72 2 4 30 72 Non-Reversing Vacuum 4 5 36 72 IT. Soft Starters 10 200 hp 12 36 Feeder : 15 600 Amps : 30 600 Amps supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. EATON WWW.EATON.COM/MCCAFTERMARKET 19

Westinghouse Type W 1965 1975 NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 12 36 1 5 12 54 FVR 1 5 18 60 1 4 18 42 2-Speed 1 Winding 1 4 18 36 2-Speed 2 Winding 1 4 18 36 IT. Soft Starters 10 200 hp 18 36 Feeder : 15 400 Amps : 30 400 Amps supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. 20 EATON WWW.EATON.COM/MCCAFTERMARKET

Westinghouse 11-300 1950 1965 NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 9 37-1/3 1 5 14 56 FVR 1 5 18-2/3 56 2-Speed 1 Winding 1 4 28 37-1/3 2-Speed 2 Winding 1 5 18-2/3 56 IT. Soft Starters 10 200 hp 18-2/3 37 Feeder : 15 400 Amps : 30 400 Amps supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. EATON WWW.EATON.COM/MCCAFTERMARKET 21

Other manufacturer MCC designs ITE/Gould 5600 Series 1957 1976 NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 12 48 FVR 1 4 CallA IT. Soft Starters 10 75 hp 18 24 Feeder : 15 400 Amps Note: 400 Amp units and above are cable in/out. No stabs are provided. supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. Note: Midshelves are not supplied. 22 EATON WWW.EATON.COM/MCCAFTERMARKET

General Electric 7700/8000 1975 Present NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 4 12 24 FVR 1 4 18 36 Feeder : 15 225 Amps supplied with UL label Note: Midshelves are not supplied. Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. EATON WWW.EATON.COM/MCCAFTERMARKET 23

Allen-Bradley Centerline Series K and later 1971 Present NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 4 12 30 1 4 12 42 FVR 1 4 18 48 1 4 24 48 IT. Soft Starters 10 75 hp 12 18 Feeder : 15 225 Amps : 30 200 Amps supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. Note: Midshelves are not supplied. are compatible with Series K and later. 24 EATON WWW.EATON.COM/MCCAFTERMARKET

Siemens/ Furnas Series 89 1979 2001 NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 4 12 24 FVR 1 4 18 36 IT. Soft Starters 10 75 hp 12 18 Feeder : 15 225 Amps supplied with UL label Note: Midshelves are not supplied. Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. EATON WWW.EATON.COM/MCCAFTERMARKET 25

Square D Model 4, Model 5 and Model 6 1970 Present NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 4 12 30 FVR 1 4 18 36 IT. Soft Starters 10 75 hp 12 18 Feeder : 15 225 Amps supplied with UL label Note: Midshelves are not supplied. Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. 26 EATON WWW.EATON.COM/MCCAFTERMARKET

Moeller Series 90, 100, 170, 200, 3000 and Modan 3000 1967 Present FVNR 1 100 @ 480V FVR 1 100 @ 480V HP Spacing (in.) HP Spacing (in.) 9 24 1 100 @ 480V 12 36 1 100 @ 480V 9 24 12 36 Feeder : 15 250 Amps : 30 200 Amps supplied with Note: Midshelves are not supplied. Note: Size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. EATON WWW.EATON.COM/MCCAFTERMARKET 27

FPE 5325/5320 1966 1978 NEMA Spacing (in.) NEMA Spacing (in.) FVNR 1 5 12 42 FVR 1 4 18 24 IT. Soft Starters CallA Feeder : 15 400 Amps Note: 400 Amp units and above are cable in/out. No stabs are provided. supplied with UL label Note: NEMA size and spacing can vary depending on starter unit. Refer to the parts catalogs for each manufacturer or calla and request a quote for more information. Note: Midshelves are not supplied. 28 EATON WWW.EATON.COM/MCCAFTERMARKET

Support services MCC Aftermarket selling tips Call your Service Center! You have a local plant that is ready to help you quote all MCC Aftermarket. Use Bid Manager. MCC Aftermarket is under Take Offs Motor Control Centers. Know what Eaton can do to help you! We can get you nearly any aftermarket unit in one day! Eaton s Web site will help you too! Just go to www.eaton.com/mccaftermarket. Be sure when quoting MCC Aftermarket Starters that you ask your customer if they need standard wiring in the unit or if there is a custom wiring diagram. Be sure to find out how much space is available in the MCC structure where the customer wants to install a new bucket. Your customer may need to purchase a blank cover to fill in empty space. EATON WWW.EATON.COM/MCCAFTERMARKET 29

Product & service locations MCC Aftermarket Four regional manufacturing locations: Chicago, IL (630) 260-6304 Houston, TX (713) 939-9696 Fayetteville, NC 1-800-OLD-UNIT (1-800-653-8648) Portland,OR (503) 582-2745 Portland, OR Chicago, IL Fayetteville, NC Main Plant Houston, TX Visit our Internet Web page at: http://www.eaton.com/electrical 30 EATON WWW.EATON.COM/MCCAFTERMARKET

MCC terminology MCC A Motor Control Center (MCC) is a series of structures fed from a main device that is filled with motor starters, soft starters, and breaker and fusible disconnect switches. They may also have metering, TVSS and communications. Bucket A bucket is the assembly containing the motor starter or feeder breaker/fusible switch that gets plugged into the MCC vertical bus. The vertical power bus is then fed through the stab assembly to the breaker or fusible switch. That breaker/fusible switch is able to disconnect power to all components it feeds. The bucket generally contains the disconnect, a CPT (Control Power Transformer), motor starter, relays, and any cover controls used to control the motor starter. Unit A unit is another term for bucket (see above). Cover Controls Cover controls are the devices seen and operated on the cover and the outside of the bucket. The most common cover controls are selector switches, pushbuttons and pilot lights. When quoting a new bucket, it is very important to find out what cover controls the customer needs so the bucket is wired properly from the factory. X Space MCC structures are measured in X space. Each X equals 6 of height. An example of how this is used is a Size 1 motor starter is generally built in a 2X bucket, or 12. Where this becomes key is in determining how much space the customer has available to add new loads. Stab Assembly The stab assembly is on the rear of the bucket and is what plugs the bucket onto the vertical bus. This must mate cleanly with the vertical bus to provide complete power to the bucket and to not arc. Cover The cover is literally the cover over the bucket or a blank cover over empty space. Many times when customers are buying new buckets, they will need additional covers to fill blank space. EATON WWW.EATON.COM/MCCAFTERMARKET 31

* At Eaton, we believe that power is a fundamental part of just about everything people do. Technology, transportation, energy and infrastructure these are things the world relies on every day. That s why Eaton is dedicated to helping our customers find new ways to manage electrical, hydraulic and mechanical power more efficiently, safely and sustainably. To improve people s lives, the communities where we live and work, and the planet our future generations depend upon. Because that s what really matters. And we re here to make sure it works. See more at Eaton.com/whatmatters Eaton Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com 2018 Eaton Corporation All Rights Reserved Printed in USA Publication No. CA04304001E / Z22074 December 2018 Eaton is a registered trademark of Eaton. All other trademarks are property of their respective owners.