Swimming Pool CSR2 Heat Recovery Equipment

Similar documents
R410A. Packaged Air Source Heat Pump AHU. A packaged solution developed with simplicity and energy efficiency in mind.

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Air Handling Units. Geniox. Accessories

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

SPECIFICATION SHEET. C5000 ( cfm)

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

CH5000 Heat Recovery Ventilator

Fan - Powered Terminal Unit Series Flow

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

ELTAFANTECH Air Handling Unit 700 up to 42,000 CFM

MODULAR AIR HANDLING UNITS GAH SERIES

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

Flash Point Process Analyzer

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

D M S 760 C01 A A 1 1

AIR HANDLING UNIT. MODEL: PM0809 to PM CFM to CFM

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Air Cooled Packaged Units

Accessories. Series REC

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

something new in the air Technical Bulletin

AIR HANDLING UNITS. Customisable modular air handling unit, designed and built to suit your project requirements

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

Indirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Air-Cooled Liquid Chiller with integrated hydraulic module

The World Leading Air-conditioning Company

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

TVFC Dry and adiabatic cooling

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

XeteX, Inc. All Rights Reserved.

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

SECTION AIR TERMINAL UNITS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PGK Rectangular duct coolers for cooled water

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

AIR-AIR ENERGY CONSERVATION MODULE

Features: Available in horizontal and vertical units

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

TECHNICAL DOCUMENTATION WOLF AIR HEATERS LH-EC / LH. 30m 3 /h

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

Air Master BCP. Pool air handling units. Optimized energy consumption Electronic control. Description. Principle schemes

AHN 064 to 304 EHN/CHN 064 to 304

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

MegaBox Product-specific information

AC Commercial Fans Edition. ErP ready

Powers TM Controls SW 141 Differential Static Airflow Switches

OTHER PRODUCTS FROM THE TURNBULL & SCOTT RANGE

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Centrifugal fan with highly efficient EC drive motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Technical Specification

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Midea Air Handling Unit

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Tubular Centrifugal Fans

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

The highest energy recovery available.

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

Halton Rex 600 RE6 - Adaptable active chilled beam

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Sentinel D-Box Single Fan

HIGH TEMPERATURE TWIN SQUIF FANS

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

Prepared By : Checked By : Approved By : Page 1 out of 6

FilterMax F. Modular dust collector with integrated pre-separator. Models

Part III : Technical Specification POS C)

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

Heat recovery units type GTDHR

FilterMax DF. Modular dust multi purpose collector. Models

2015 F-250, 350, 450, 550 Super Duty DESCRIPTION AND OPERATION Procedure revision date: 04/28/2016. Climate Control System

GigaBox centrifugal fans Product specific information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

D1M L1 T2 TB DATA SHEET A1-1130H-1400W. PANELS / FRAME Panels PART CODE Insulation

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

POWER for AIRCRAFT GSE

FilterMax DF. Modular dust multi purpose collector. Models

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

next dx next dx rcgroupairconditioning NEXT DX: Direct expansion close control air conditioners equipped with scroll compressors and Plug-fans.

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

OPERATING AND MAINTENANCE INSTRUCTIONS for the GOLD Air Handling Unit, Sizes Applicable to Program Version 1.20 and newer versions

DCV-LC DCV-LC. DCV-LC Lab climate control unit. Lab climate control SMART DAMPERS & MEASURING UNITS. Product description. Occupancy AIN AOUT DCV-LC

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Transcription:

Swimming Pool CSR2 Heat Recovery Equipment LIFETIME WARRANTY OVER 90% HEAT RECOVERY LOW CARBON British manufacturing at its best EcoAir Box is a trademark of IPT +44 (01527) 492770 www.ecoairbox.co.uk

Introduction The CSR2 Low Carbon Solution heat recovery unit is specifically designed for Swimming Pools and Leisure Centres. The unit provides high levels of internal air temperature and humidity control to establish a healthy environment for the bathers and to ensure interstitial condensation does not form within the structural envelope, which due to the nature of the chemicals involved can cause structural failure, at the same time as providing the highest level of internal environmental control. The CSR2 Low Carbon Solution heat recovery unit can recover over 90% of the energy required to heat the incoming fresh air, dependent upon specification, reducing the heating requirement on the incoming fresh air so enabling to reduce the size of the boiler. The energy recovery is achieved by an exceptionally efficient air to air heat recovery matrix which has a very low energy requirement due to an advanced aerodynamic design and together with a composite construction achieving a lifetime guarantee against corrosion. In addition to exceptionally high heat recovery performance the CSR2 has an advanced fan speed regulation which allows fan power to reduce by up to 80% as the de-humidification load reduces at times of low occupancy and overnight. Air Volume range up to 12m3/s Packaged solution Small footprint Monitors temperature Monitors humidity levels Protects the building from decay Energy efficient Integral intelligent controls system Low Maintenance Lifetime Warranty 90% heat recovery Reduces other plant sizes Low running cost Quiet operation.

Construction The construction of the pool air handling unit shall be certified to EN1886 with the minimum classifications for an indoor unit: Mechanical security of housing class 1A Housing leakage class A Heat transfer classification T4 Warm bridge factor classification TB3 The framework shall be manufactured from fully insulated extruded aluminium section, anodised and powder coated finish. All panels shall be double skin composite construction with a bonded internal insulation together with an external powder coated aluminium skin. The unit base shall be plastic lined or resin treated in the recuperator and outside air sections to allow free drainage of water during operation and cleaning. Return air filter section shall also be resin treated with an inclusion of a drain. Separate drainage pipe work from the return air, recuperator and outside air sections including taps and fittings shall be incorporated in the unit. Each section of the unit shall be supported on all 4 sides by a stable 120mm galvanized steel base frame with access points to all drainage pipe work, traps and fittings. Fig. A The internal finish of the panels shall be composite and totally impervious to chemical used in a swimming pool environment or any condensation that may form. All removable panels shall have a continuous high efficiency seal to prevent the ingress of air. (See Fig. A ) Powder coated anodised aluminium All panels on the service access side of the unit shall incorporate warm bridge free quick release fasteners. Double glazed inspection windows with internal lighting shall be provided for monitoring all airways and components (ie fans, bypass dampers, recuperator drain tray).

Direct Driven Fans Fans shall be free running ventilator wheels directly coupled to capacity optimised motors with frequency controllers. High performance power optimised ventilator wheel with epoxy powder coated backward curved steel blades directly coupled to the motor shaft. Epoxy powder coated inlet cone with protection grid.fan guards on service access side of unit. Optimum efficiency motors with integral frequency controllers for power ratings from 1.5 to 7.5Kw mounting type B3, protection to IP54, isolation class F. From 11.0Kw capacity, optimum efficiency motor, mounting type B3, protection to IP54, isolation class F with separate frequency controller units. The fan, motor and inlet cone shall be installed on a purposed built single mounting frame with anti-vibration isolation from the unit. The fan and motor assembly shall be balanced together to DIN ISO 1940 part G 25 and a certificate shall be issued. Vibration sensors shall be installed for each fan as a security device for continuous monitoring of the fan/motor construction with a display of the actual vibration level in mm/s on the digital controller. The fan motor assembly shall be continuously monitored on the digital controller for vibration during the life of the unit. Increasing bearing wear or mechanical damage shall be displayed as a clear text message on the control panel. The unit shall automatically shut down in the event of a serious mechanical fan or motor fault. Creates a near linear airflow. No requirement for fan diffuser. Locate duct bends directly after unit. Space saving (reduces footprint). No belts. No Pulleys. Built in frequency controller. Variable speed. More efficient (No belt or pulley losses). Better SFP s. Low maintenance Low noise Composite impeller on EC motor driven fans (optional).

Plate Heat Exchanger Boasting 90% efficiency, this new groundbreaking double plate heat exchanger comes in 2 airflow scenarios (FIG A & B), 100% resistant to the swimming pools corrosive atmosphere and is extremely light weight. This means that when external temperatures are as low as 5 C, you are able to recover heat from the extract and supply air at 26.5 C without any other expense. (figures based upon return air at 30 C). The plate heat exchanger plates shall be vacuumed form thin section composite for maximum efficiency of heat transfer and not from the thicker fluted inefficient panel type. The plate heat exchanger shall be optimised for all operational conditions for maximum efficiency and have a pressure drop lower than and efficiency higher than the old fluted panel type of construction. Fig. A Fig. B The plate heat exchanger shall be a high efficiency composite construction guaranteed against corrosion from the chemicals in a swimming pool environment for life. The plate heat exchanger shall not be manufactured from fluted panels without the current inward and exhaust airways to reduce pressure drop. Double recovery. 90% Efficient. Reduces expensive additional heat input. Low pressure drop design. Composite construction. Lifetime Guaranteed against Corrosion. Extremely lightweight.

LPHW Coil Low temperature hot water heating coil with aluminium fins, copper tubes and Polyurethane lacquer finish to fins, tubes, header and casing. 3 way mixing valve with screwed connections, actuator and frost protection thermostat. Bypass around low temperature hot water coil for separate duct connection to spectator zone. Dampers Air control dampers shall be metal free composite construction complete with blade seals to ensure effective isolation of the air stream. All movement shall be achieved via composite drive gears fitted within the air stream to avoid contamination, damper linkages shall not be acceptable. The damper construction shall allow full opening of the air path for the lowest pressure loss and optimum air flow onto the components.. Every damper motor shall include a feedback Potentiometer and shall be individually adjusted or closed over the direct digital control system. Metal free Composite construction Composite drive gears Extremely lightweight Blade seals Minimum heat output required Small low duty coil Feedback potentiometer Low pressure loss Actuator Included. Coated fins to resist corrosion Coated header to resist corrosion Coated casework to resist corrosion Coated tubes to resist corrosion Packaged with valve & actuator Frost protection thermostat.

Washable Panel Filter Filters and filter housings to EN779 and EN1886. Aluminium washable filters class G4 shall be installed in the return air and Supply air. These filters are designed to remove any dead skin that has got into the return air stream from the pool area. Each filter shall have a filter pressure drop manometer with the actual pressure drop displayed on the control panel and low level alarm when filter dirty as a clear text message on the controller. Bag Filters Filters and filter housings to EN779 and EN1886. Bag filters class F7 shall be installed in the supply air. Filters shall not be installed in any mixed air stream. Fully incinerable filters with plastic frames. Filter housing to EN1886 with filter bypass leakage to class F8. Each filter shall have a filter pressure drop manometer with the actual pressure drop displayed on the control panel and low level alarm when filter dirty as a clear text message on the controller. Suitable for 100% RH Do not require frost protection Low pressure drop Plastic frame Corrosion free Can be incinerated Manometer Included Filter dirty alarm & text message. Low pressure drop Washable Manometer Included. Filter dirty alarm & text message Takes out the larger particles which would usually clog finer filters.

Trend Control System The unit shall be supplied with a control panel including a readily programmable direct digital controller. Cabling to all control, regulation and drive components shall be built into the unit and factory tested. The control panel shall include: Door interlocked isolator. Terminals for main power supply. Motor and control components. Component isolators. Safety circuits. All necessary components for motor control including fuses and overloads. Programs and time clocks shall remain secure in the event of power failure. The essential sensors for measuring outside air temperature, supply air temperature/humidity, return air temperature/humidity, all damper actuators and the hot water coil valve shall be connected to a single bus system. All sensors and actuators shall be individually readily programmable and individually addressable. Permanent communication shall be provided to monitor and detect failure of any sensor/actuator or any break down of communication with any component. Connection of all sensors/actuators shall be achieved by a M12 ply system with distribution junction boxes and tested shielded twisted paid cables for communication up to 100m over a free network structure. A terminal strip shall be provided for connections to external components and control signals. All potential free contacts suitable for 230V/2A. An operation and status panel with keypad for data entry and function control shall be provided with an LCD display for set points and actual values, damper positions, hours run and status messages text as well as Trend BEMs complete with LED s for operation and fault status. Remote Monitoring & Interface The control system shall have the facility for remote monitoring and adjustment by the supplier over an analogue or ISDN modem. The unit shall include an interface or gateway approved for use with the following BMS systems: Bacnet over IP The interface shall provide access to data points giving information on all temperature and humidity values, actuator positions, status of all motors, hours run, actual supply and return air flow in m3/h, filter pressure drop displayed in Pa.

Direct Digital Control The function control software and all aspects of control and regulation devices shall be tested and documented under a certified EN ISO 9001: 2000 quality system. Control and regulation functions shall include: Mode of operation selection:- Pool in use, pool not in use and automatic operation shall be selected on the user interface. Automatic operation for pool in use operation over the programmable time clock channel or from an external signal (eg movement sensor, light switch or BMS input). Enable outside air:- Enable mixing of outside air to replace pool hall air on a timed basis. This shall also be enabled by an external contact. Pool hall temperature regulation: return air temperature control with supply air minimum and maximum values. Return air temperature set point shall be adjustable on the controller within a preset range. Variable air volume:- In recirculation operation the air volume shall be automatically adjusted according to the heating requirement in order to reduce energy consumption. Humidity control:- The humidity set point for the pool in use period shall be adjusted on the controller. When the pool is not in use the humidity set point shall vary according to the outdoor temperature. Sensor monitoring:- Short circuits, cable breakdowns etc shall activate general fault indication with a clear text Fault indication:- Scheduled as high and low level alarms and shown on LED s and in clear text on the display. For remote indication of fault signals, potential free signals shall also be available on the terminal strip. Operating mode simulations shall be provided for testing, commissioning, maintenance or in the event of an emergency. Air Volume Regulation Air volumes shall be automatically adjusted to ensure that the pool hall remains under a constant negative pressure during the occupied period. The supply and return air volumes shall be individually programmable in m3/h. The supply and return air flow shall be continuously displayed in m3/h with an accuracy of ± 3.0% through temperature compensation. The fan motor speeds shall be automatically adjusted in order to maintain the programmed air volumes during different modes of operation or when the filters become progressively dirtier. The pool hall unit shall be factory assembled. Testing and test documentation of the pool hall unit shall be carried out under a certified EN ISO 9001 : 2000 quality system.

Unit Sizing Chart Model Air Volume Overall Dimensions Coil Duty Heat Exchanger Air Off Reference (m3/s) (L x W x H) inc base (Kw) Efficiency (%) Temperature C CSR2 2000 SS 2 3000 x 1300 x 1950 60.20 72.5 20.4 CSR2 2500 SS 2.5 3200 x 1300 x 2150 69.39 77.5 22.1 CSR2 3000 SS 3 3500 x 1300 x 2350 81.41 78.7 22.6 CSR2 4000 SS 4 3800 x 1300 x 2650 114.97 75.4 21.4 SINGLE PLATE CSR2 4000 SD 4 3000 x 2500 x 1950 120.39 72.5 20.4 CSR2 5000 SS 5 4400 x 1300 x 3350 145.56 74.8 21.2 CSR2 5000 SD 5 3200 x 2500 x 2150 138.77 77.4 22.1 CSR2 6000 SS 6 5000 x 1300 x 3600 173.19 75.2 21.3 CSR2 6000 SD 6 3500 x 2500 x 2350 162.83 78.6 22.5 CSR2 8000 SD 8 3800 x 2500 x 2650 230.92 75.3 21.3 CSR2 10000 SD 10 4000 x 2500 x 2850 291.12 74.6 21.1 CSR2 12000 SD 12 5000 x 2500 x 3600 349.34 75.1 21.3 Model Air Volume Overall Dimensions Coil Duty Heat Exchanger Air Off Reference (m3/s) (L x W x H) inc base (Kw) Efficiency (%) Temperature C CSR2 1800 DS 1.8 2950 x 1300 x 1900 40.19 87.8 25.7 CSR2 2200 DS 2.2 3450 x 1300 x 2100 44.78 91.3 27 CSR2 2800 DS 2.8 4200 x 1300 x 2250 55.95 91.8 27.1 CSR2 3300 DS 3.3 4400 x 1300 x 2650 69.2 90.3 26.6 DOUBLE PLATE CSR2 3600 DD 3.6 2950 x 2500 x 1900 80.82 87.6 25.7 CSR2 4000 DS 4 4600 x 1300 x 2950 84.37 90 26.5 CSR2 4400 DD 4.4 3450 x 2500 x 2100 88.47 91.2 26.9 CSR2 5000 DS 5 6000 x 1300 x 3350 105.47 90 26.5 CSR2 5600 DD 5.6 4200 x 2500 x 2250 112.6 91.8 27.1 CSR2 6600 DD 6.6 4400 x 2500 x 2650 138.4 90.2 26.6 CSR2 80000 DD 8 4600 x 2500 x 2950 168.75 89.9 26.5 CSR2 10000DD 10 6000 x 2500 x 3350 210.94 90 26.5 Outside Ambient = -5 C @ 100% RH Return Air = 30 C @ 65% RH Coil Flow & Return = 82/71 C Off Coil temp = 45 C

Single Plate Layout Double Plate Layout

Psychometric Chart SI (metric units) Barometric Pressure 101.325 kpa (sea level) EcoAir Box Cooper House Corbett Business Park Shaw Lane Bromsgrove B60 4EA t +44 (0)1527 492770 w www.ecoairbox.co.uk