SPORTS: Football pitch for class III Customer : Processed by : Siteco Light Consulting Project description: Maintenance factor 0,8 Football field 105 x 68m 4-mast-layout Mast height 16m 2 floodlights per mast Inclination 10 The determination of the lighting results is performed on a sales support basis, with great thoroughness, using the documents at our disposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). A guarantee / warranty / liability for this free calculation is not provided by SITECO. In this respect, we refer to the services of the light planning and engineering office. The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur. Guarantee claims for luminaire data are excluded. Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties. Page 1/8
Table of contents First Page 1 Table of contents 2 1 Luminaire data 1.1 Siteco, SiCOMPACT A3 MAXI (5NA76901WS02) 1.1.1 Data sheet 3 2 Football pitch 75 lux 2.1 Description, Football pitch 75 lux 2.1.1 Floor plan 4 2.1.2 3D view, View 1 5 2.2 Summary, Football pitch 75 lux 2.2.1 Result overview, Football field 6 2.3 Calculation results, Football pitch 75 lux 2.3.1 Table, Football field (E) 7 2.3.2 3D luminance, View 1 8 Page 2/8
1 Luminaire data 1.1 Siteco, SiCOMPACT A3 MAXI (5NA76901WS02) 1.1.1 Data sheet Manufacturer: Siteco 5NA76901WS02 floodlight-pylon annexe SiCOMPACT A3 MAXI SiCOMPACT A3 MAXI, floodlight, primary light control with reflector, of aluminium, hammer dimple, primary optical cover: cover panel, of toughened safety glass, light emission: direct distribution, primary light characteristic: asymmetric, installation type: surface-mounted, for 1 x HIT-DE l=187 2000W, superimposed pulse ignitor, internal, control gear: without control gear, with terminal, 3-pole, max. 2.5mm², mains connection: 400V, AC, 50Hz, luminaire housing, of diecast aluminium, sandblasted, natural, mounting bracket, of steel, galvanised, protection rating (complete): IP65, insulation class (complete): insulation class I (protective earthing), certification: CE, impact resistance: IK08, standard: EN 50419, packaging unit: 1 piece, Luminaire data Luminaire efficiency : 74.3% Luminaire efficacy : 74.3 lm/w Classification : A20 100.0% 0.0% CIE Flux Codes : 26 65 98 100 74 UGR 4H 8H (20%, 50%, 70%) C0 / C90 : 45.9 / 32.7 Control gear : LLCG System power : 2100 W Length : 709 mm Width : 581 mm Height : 225 mm Equipped with Quantity : 1 Designation : HIT-DE-h15 2000W/959 (OSRAM) Power : 2000W Colour : Luminous flux : 210000 lm Page 3/8
2 Football pitch 75 lux 2.1 Description, Football pitch 75 lux 2.1.1 Floor plan [m] 40 N 30 20 10 0-10 -20-30 -40-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 [m] 1 : 1000 Page 4/8
2.1 Description, Football pitch 75 lux 2.1.2 3D view, View 1 Page 5/8
2 Football pitch 75 lux 2.2 Summary, Football pitch 75 lux 2.2.1 Result overview, Football field [m] 40 N 30 20 10 0-10 -20-30 -40-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 [m] Illuminance [lx] 50 75 100 150 200 General Calculation algorithm used Direct component Height of evaluation surface 0.00 m Maintenance factor 0.80 Total luminous flux of all lamps Total power Total power per area (9600.00 m²) 1680000 lm 16800 W 1.75 W/m² Illuminance Average illuminance Eav 88 lx Minimum illuminance Emin 56 lx Maximum illuminance Emax 153 lx Uniformity Uo Emin/Em 1:1.59 (0.63) Diversity Ud Emin/Emax 1:2.74 (0.36) Type No.\Make Siteco 1 8 Order No. : 5NA76901WS02 Luminaire name : SiCOMPACT A3 MAXI Equipment : 1 x HIT-DE-h15 2000W/959 (OSRAM) 2000W / 210000 lm Page 6/8
2 Football pitch 75 lux 2.3 Calculation results, Football pitch 75 lux 2.3.1 Table, Football field (E) [m] 60 58 77 102 117 144 121 121 103 86 78 75 77 86 103 120 122 147 117 102 76 58 69 83 96 127 150 [153] 115 106 101 97 93 96 101 106 114 [153] 150 127 96 82 69 55 69 80 92 116 114 122 120 104 102 101 102 101 102 103 120 122 114 116 92 80 69 50 45 40 35 30 25 20 15 10 5 0 66 75 91 94 89 94 106 104 98 99 100 99 98 104 106 94 89 93 90 74 66 63 71 80 78 72 79 92 94 94 95 95 95 94 94 92 79 73 78 80 70 62 59 65 70 68 63 68 80 87 89 90 90 90 89 87 80 68 63 68 70 65 59 57 61 64 62 59 63 74 81 85 87 88 87 85 81 74 63 59 62 63 61 57 (56) 60 61 59 57 61 71 78 84 86 86 86 84 78 71 61 57 59 61 60 (56) 57 61 64 62 59 63 74 81 85 87 88 87 85 81 74 63 59 62 64 61 57 59 65 70 68 63 68 80 87 89 90 90 90 89 87 80 68 63 68 70 65 59 62 70 80 78 73 79 92 94 94 95 95 95 94 94 92 79 72 78 80 71 63 66 74 90 94 89 94 106 104 98 99 100 99 98 104 106 94 89 94 91 75 66 69 80 92 116 114 122 120 103 102 101 102 101 102 104 120 122 114 116 92 80 69 69 82 96 127 150 [153] 114 106 101 96 93 97 101 106 115 [153] 150 127 96 83 69 58 76 102 117 147 122 120 103 86 77 75 78 86 103 121 121 144 117 102 77 58 0 10 20 30 40 50 60 70 80 90 100 [m] Illuminance [lx] Height of the reference plane : 0.00 m Average illuminance Eav : 88 lx Minimum illuminance Emin : 56 lx Maximum illuminance Emax : 153 lx Uniformity Uo Emin/Eav : 1 : 1.59 (0.63) Diversity Ud Emin/Emax : 1 : 2.74 (0.36) Page 7/8
2.3 Calculation results, Football pitch 75 lux 2.3.2 3D luminance, View 1 Luminance in the scene Minimum: Maximum: : 0 cd/m² : 13.7 cd/m² Page 8/8