SPORTS: Football pitch for class III

Similar documents
SPORTS: Football pitch for class III

SPORTS: Football pitch for class II

SPORTS: Football pitch for class II

SATCOM. Project number : Customer : RAF Croughton Processed by : D.Kaye Date : please put your own address here- Page 1/36

assembly hall Project number : sample system Customer : Processed by : Siteco Light Consulting Date : 10/ 2013

Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties.

Tunnel. Project number : Int_0001 Customer : Processed by : Date : Project description: Sample Tunnel (CIE 88:2004)

BRUDA. Removable control gear plate. Computer aided design reflector. Single piece high-pressure diecast aluminium housing.

headliner. made-to-measure or ready-made profile solution with superior efficiency & light output results

Chapter 4 Luminaires for special applications

264 urban lighting VIGILA

DATASHEET V aron.

Appendix Q. Substation Lighting Specification Details

KATU- JA ALUEVALAISTUS PRO FLOW

Start Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K

Start Waterproof LED START WATERPROOF LED 1265MM TWIN 4000K PRODUCT OVERVIEW

Floodlight LED Series 6525

Floodlight LED Series 6125

Light is powerful Floodlight 20 maxi.

Report of Test LLIA

Nightscape High performance floodlights and spotlights for discharge lamps

Report of Test LLIA

TUNNEL LED LIGHTING. High power, low consumption public LED lighting

Report of Test LLIA

Smooth Wall effect and pole mounted. Design K.Begasse.

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA

OptiVision LED gen2 a new era in smart area and recreational sports lighting

Report of Test LLIA

Beam Type Lamp Type Gear Type. Rated Input Power

Report of Test LLIA

Report of Test LLIA

FLC131 LED + Linear spread lens IO

Report of Test LLIA

S BERGIN R BEATTIE Lighting Engineer. Checked Approved

OptiVision LED a new age in smart area and recreational sports lighting

Luminaire Property. Photometric Results. Page 1 of 18 Pages. Report No.: Test Time: :33:29

Luminaire Property. Photometric Results. Page 1 of 18 Pages. Report No.: Test Time: :18:08

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Product Description SON-T. Benefits. Features. Application. Versions. High Pressure Sodium lamp with clear tubular outer bulb

Thorn GLORIE X38W TC-DD LO AC WHI [STD] / Luminaire Data Sheet

Floodlight LED Series 6525

Report of Test LLIA A-R02*

RONDO-01 TECHNICAL SHEET. Outdoor architectural projector. About the product RONDO-01-80W, RONDO-01-35W, RONDO-01-20W, RONDO-01-70W

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01

Report of Test LLIA A

ToLEDo T8 ToLEDo T8 V4 5FT 27W 2700LM

LEDVANCE SPOTLIGHT XXL

Report of Test LLIA

Sistema Easy. Sistema Easy MH page 115. ø 212. Sistema Easy FL page 117. Sistema Easy FL page 117. ø 212. ø 250. design Maurizio Varratta

Innovation. New LED Lights for Smart Indian & Global Cities. Lights for Life. For Exploring LED Technology Benefits. 12m m

Report of Test LLIA A

Report of Test LLIA A

HIGH BAY HIGH LUMEN LED INDUSTRIAL LUMINAIRE

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Report of Test LLIA

Product Description SON-T. Benefits. Features. Application. High Pressure Sodium lamp with clear tubular outer bulb

LM-79 Test Report. CLS LED BV LM79-EMERALD-M7-3000K-80CRI. General Discription. Date and time :45:05

Report of Test LLIA A-R01*

Report of Test LLIA A

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

HSI-HX / HSI-THX SA HSI-THX 400W 4K E40 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

Chapter 8 Highbay luminaires

IVIOS LED III. LUM Technical Information

LED DOWNLIGHTS. Prime K L LED Downlights HIGH QUALITY COB TECHNOLOGY LED-DOWNLIGHTS

LED CANOPY with j-box

MECREE LED FLOOD LIGHT SERIES MECREE Photoelectric Technology Co., Ltd

MACH 3 D10,5 D10,5 D10,5. Light as star

ArenaVision LED gen2 enabling sports venues to offer a new. experiences. ArenaVision LED gen2. Benefits. Features

Ecospot LED floodlights

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Report of Test LLIA A

LLIA A-R02*

APPLICATION. MisaL Oy Kiviaidankatu 2C, Helsinki, Finland tel: misal.fi

Light as emotion MACH 2

PRODUCT FAMILY DATASHEET LEDVANCE HIGH BAY LED

LM-79. CLS LED BV LM79-JADE-EXPO-4000K-CRI90-SPOT. Test Report. General Discription. Date and time :17:11

Reflex. Reflex. Chip on Board (C.o.B.) frame / minimal page 90/96/100. Wall Washer optic. Adjustable optic. Fixed optic. ø 242. ø 212. ø 153.

Report of Test LLIA A

Report of Test LLIA A

Example: L80B10 > h means that not more than 10% of the luminaires fall below 80% of the luminous flux after h.

Nano Liner Allegro AC XB

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

PHONE: (303) FAX: (970) WEBSITE:

CANILO SUSPENDED LUMINAIRES

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

CoreLine Recessed the clear choice for LED

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

ETC330-FS LED

LED Security Wallpack Installation Instruction

FLOODLIGHT SYSTEM.

Technical information MINI NICOLE, NICOLE & MAXI NICOLE LUMINAIRES

High Power LED Projectors STREETLIGHT 60W & 90W

Ecospot LED floodlights

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Transcription:

SPORTS: Football pitch for class III Customer : Processed by : Siteco Light Consulting Project description: Maintenance factor 0,8 Football field 105 x 68m 4-mast-layout Mast height 16m 2 floodlights per mast Inclination 10 The determination of the lighting results is performed on a sales support basis, with great thoroughness, using the documents at our disposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). A guarantee / warranty / liability for this free calculation is not provided by SITECO. In this respect, we refer to the services of the light planning and engineering office. The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur. Guarantee claims for luminaire data are excluded. Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties. Page 1/8

Table of contents First Page 1 Table of contents 2 1 Luminaire data 1.1 Siteco, SiCOMPACT A3 MAXI (5NA76901WS02) 1.1.1 Data sheet 3 2 Football pitch 75 lux 2.1 Description, Football pitch 75 lux 2.1.1 Floor plan 4 2.1.2 3D view, View 1 5 2.2 Summary, Football pitch 75 lux 2.2.1 Result overview, Football field 6 2.3 Calculation results, Football pitch 75 lux 2.3.1 Table, Football field (E) 7 2.3.2 3D luminance, View 1 8 Page 2/8

1 Luminaire data 1.1 Siteco, SiCOMPACT A3 MAXI (5NA76901WS02) 1.1.1 Data sheet Manufacturer: Siteco 5NA76901WS02 floodlight-pylon annexe SiCOMPACT A3 MAXI SiCOMPACT A3 MAXI, floodlight, primary light control with reflector, of aluminium, hammer dimple, primary optical cover: cover panel, of toughened safety glass, light emission: direct distribution, primary light characteristic: asymmetric, installation type: surface-mounted, for 1 x HIT-DE l=187 2000W, superimposed pulse ignitor, internal, control gear: without control gear, with terminal, 3-pole, max. 2.5mm², mains connection: 400V, AC, 50Hz, luminaire housing, of diecast aluminium, sandblasted, natural, mounting bracket, of steel, galvanised, protection rating (complete): IP65, insulation class (complete): insulation class I (protective earthing), certification: CE, impact resistance: IK08, standard: EN 50419, packaging unit: 1 piece, Luminaire data Luminaire efficiency : 74.3% Luminaire efficacy : 74.3 lm/w Classification : A20 100.0% 0.0% CIE Flux Codes : 26 65 98 100 74 UGR 4H 8H (20%, 50%, 70%) C0 / C90 : 45.9 / 32.7 Control gear : LLCG System power : 2100 W Length : 709 mm Width : 581 mm Height : 225 mm Equipped with Quantity : 1 Designation : HIT-DE-h15 2000W/959 (OSRAM) Power : 2000W Colour : Luminous flux : 210000 lm Page 3/8

2 Football pitch 75 lux 2.1 Description, Football pitch 75 lux 2.1.1 Floor plan [m] 40 N 30 20 10 0-10 -20-30 -40-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 [m] 1 : 1000 Page 4/8

2.1 Description, Football pitch 75 lux 2.1.2 3D view, View 1 Page 5/8

2 Football pitch 75 lux 2.2 Summary, Football pitch 75 lux 2.2.1 Result overview, Football field [m] 40 N 30 20 10 0-10 -20-30 -40-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 [m] Illuminance [lx] 50 75 100 150 200 General Calculation algorithm used Direct component Height of evaluation surface 0.00 m Maintenance factor 0.80 Total luminous flux of all lamps Total power Total power per area (9600.00 m²) 1680000 lm 16800 W 1.75 W/m² Illuminance Average illuminance Eav 88 lx Minimum illuminance Emin 56 lx Maximum illuminance Emax 153 lx Uniformity Uo Emin/Em 1:1.59 (0.63) Diversity Ud Emin/Emax 1:2.74 (0.36) Type No.\Make Siteco 1 8 Order No. : 5NA76901WS02 Luminaire name : SiCOMPACT A3 MAXI Equipment : 1 x HIT-DE-h15 2000W/959 (OSRAM) 2000W / 210000 lm Page 6/8

2 Football pitch 75 lux 2.3 Calculation results, Football pitch 75 lux 2.3.1 Table, Football field (E) [m] 60 58 77 102 117 144 121 121 103 86 78 75 77 86 103 120 122 147 117 102 76 58 69 83 96 127 150 [153] 115 106 101 97 93 96 101 106 114 [153] 150 127 96 82 69 55 69 80 92 116 114 122 120 104 102 101 102 101 102 103 120 122 114 116 92 80 69 50 45 40 35 30 25 20 15 10 5 0 66 75 91 94 89 94 106 104 98 99 100 99 98 104 106 94 89 93 90 74 66 63 71 80 78 72 79 92 94 94 95 95 95 94 94 92 79 73 78 80 70 62 59 65 70 68 63 68 80 87 89 90 90 90 89 87 80 68 63 68 70 65 59 57 61 64 62 59 63 74 81 85 87 88 87 85 81 74 63 59 62 63 61 57 (56) 60 61 59 57 61 71 78 84 86 86 86 84 78 71 61 57 59 61 60 (56) 57 61 64 62 59 63 74 81 85 87 88 87 85 81 74 63 59 62 64 61 57 59 65 70 68 63 68 80 87 89 90 90 90 89 87 80 68 63 68 70 65 59 62 70 80 78 73 79 92 94 94 95 95 95 94 94 92 79 72 78 80 71 63 66 74 90 94 89 94 106 104 98 99 100 99 98 104 106 94 89 94 91 75 66 69 80 92 116 114 122 120 103 102 101 102 101 102 104 120 122 114 116 92 80 69 69 82 96 127 150 [153] 114 106 101 96 93 97 101 106 115 [153] 150 127 96 83 69 58 76 102 117 147 122 120 103 86 77 75 78 86 103 121 121 144 117 102 77 58 0 10 20 30 40 50 60 70 80 90 100 [m] Illuminance [lx] Height of the reference plane : 0.00 m Average illuminance Eav : 88 lx Minimum illuminance Emin : 56 lx Maximum illuminance Emax : 153 lx Uniformity Uo Emin/Eav : 1 : 1.59 (0.63) Diversity Ud Emin/Emax : 1 : 2.74 (0.36) Page 7/8

2.3 Calculation results, Football pitch 75 lux 2.3.2 3D luminance, View 1 Luminance in the scene Minimum: Maximum: : 0 cd/m² : 13.7 cd/m² Page 8/8