EPS-ECONOMY PUMP STARTER

Similar documents
EPS-ECONOMY PUMP STARTER

TDX - Taco Duplex Starter with

Submittal Data Information

Designed for ease of integration with automation systems

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

INDUSTRIAL STARTERS ADVANCED SOLUTIONS FOR INDUSTRIAL APPLICATIONS

SECTION MOTOR CONTROL

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

Large Drive. Variable Speed Control is Just the Beginning. Franklin FastApp Firmware. Variable Speed Control NEMA. Standard Features (Enclosed Drives)

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Softstarters. Softstarters Power electronic brakes Type PEB

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

Submittal Data Information

Overload Relay Heater Tables

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

GPH2 Combination Soft Starters

Power electronic brakes

Selection Guide Motor Control Device Solutions

Softstarters Type PSS. Softstarters. General information

HVW701 HVAC Drive with By-Pass

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Sensorless Vector Drives

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

Plug and Play Kit Installation and Wiring (Non-Combo and Combo)

SECTION ENCLOSED CONTROLLERS

RVS-DN Digital Reduced Voltage Motor Starter

HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars

GPH2. Soft Starters. Applications. Standard Features. Centrifugal Pumps Screw Compressors Centrifugal Fans Wood Chipper Veneer Lathe Saw Conveyor

BAC Custom Engineered Controls

MaxPak Plus Analog DC V S Drive

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

CONSTANT PRESSURE CONTROLLERS

Motor Protection. Presented By. Scott Peele PE

NEMA Contactors & Starters (Freedom)

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

Type E/F Simplex & Duplex Pump Controllers

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

CI-TI Contactors and motor starters Types CI 61 - CI 98

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

Aquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2

AF series contactors (9 2650)

Industry Automation Control Components

Application Description

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

3. Coils shall be of molded construction

825-P Modular Protection System for motors Specification Guide

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

RVS-DX Digital Reduced Voltage Motor Starter

ECET Industrial Motor Control. NEMA Ratings. National Electrical Manufacturers Association

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types

SIGNAL WORDS QUALIFIED PERSON

MAGNETIC MOTOR STARTERS

AF series contactors (9 2650)

ADJUSTABLE FREQUENCY CRANE CONTROLS

ALTIVAR FLEX58 Chassis Drive Controller Product Selection

Motors Automation Energy Coatings. CrusherDuty. g Roller Bearing. g Reinforced Cast Iron. g Durable. Motor TPH Starter.

15 Recommended Spare Parts

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

PATTERSON PUMP COMPANY

Self-protected Combination Starters System PKZ 2-SP

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

SDS Enclosed Star-Delta Starter User Guide

Operation and Protection of Motors up to 600Hp at 460Vac (800A)

Delta Products VFD CP2000 Bypass Control Packages.

Franklin Electric Submersible Motors SUBMERSIBLE MOTORS. Motors Accessories. Product Information and Service

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Variable Speed Product Line

LF Series Spring Return Direct Coupled Actuator

Product Guide. enclosed NEMA STARTERS

UMBW-UL489 and UL1077 Listed

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Part # Features & Applications Specifications Cross Reference

MODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1


M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Enclosures. See Section Typical Description

CWM_N NEMA Rated Contactors

CTi Automation - Phone: Fax: Web:

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

Transcription:

EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com

EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides a simple and dependable starting option with a wide electronic overload range that meets submersible standards for overload protection. Offered exclusively through water systems distributors for agricultural and industrial applications, the EPS accepts 200-600 VAC while covering submersible systems between five and 20 horsepower at 200V, five and 25 horsepower at 230V, and five and 50 horsepower at 480V in just three models. It is available with a NEMA 3R enclosure for indoor and outdoor use or a cost-effective NEMA 1 enclosure with a smaller footprint for better installation flexibility. Internally, the EPS features a circuit breaker with easy-to-replace components to eliminate the need to replace burnt fuses. It has a true plug-and-play design that is compatible with single- and three-phase products, is CSA and UL approved, and includes a dry contact auto-run input and fault relay output. FEATURES Integrated Electronic Overload Protection Class S electronic overload protection specifically designed for submersible motors Phase loss protection Multi-Voltage Operating Range with Automation I/O Accepts 200-600 VAC directly with no adjustments, true plug and play Control I/O includes a dry contact auto-run input and fault relay output Industrial Grade Construction High reliability Door mounted, heavy-duty HOA switch NEMA 1, 3R, 4, and 4X enclosure options; 3R enclosed EPS have a Service Entrance Rated circuit breaker disconnect option NEMA/IEC rated contactors that will survive up to 2.5 million electrical cycles Thoroughly tested and designed to run on multiple power sources power line, generators, phase converters Factory Installed Options Available Surge suppressors Control power transformer Fault and run pilot lights Keyed HOA switch Float switch control terminals 2

EPS-ECONOMY PUMP STARTER ORDERING INFORMATION 3-Phase, 50/60 Hz, 200~600 VAC, NEMA Type 3R Enclosed - Combination Starter. Includes Service Entrance Circuit Breaker Disconnect. 3-PHASE Max. SFA* Part No. 200 V - 460 V 600 V Contactor SFA Range* (A) SFA Range* (A) 200 V 230 V 460 V 600 V NEMA Size SFA SFA SFA SFA EPS3R-S0-R-G15 6~8 6~8 8 8 8 8 EPS3R-S0-R-G20 8~11 8~11 11 11 11 11 0 EPS3R-S0P-R-G30 12~17 12~17 17 17 17 17 EPS3R-S0P-R-G40 16~22 16~22 22 22 22 22 0+ EPS3R-S1P-R-G50 20~28 20~28 28 28 28 28 EPS3R-S1P-R-G60 24~32 24~32 32 32 32 32 1+ EPS3R-S2-R-G80 32~45 32~45 45 45 45 45 EPS3R-S2-R-G100 40~52 40~52 52 52 52 52 2 EPS3R-S3-R-G125 50~71 50~71 71 71 71 71 3 EPS3R-S3P-R-G150 60~80 60~77 80 80 80 77 3+ * Use SFA Range or Max. SFA when sizing for submersible motor applications; if an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range ORDERING INFORMATION 3-Phase, 50/60 Hz, 200~600 VAC, NEMA Type 3R Enclosed - Standard Starter. Disconnect Not Included. 3-PHASE Max. SFA* Part No. 200 V - 460 V 600 V Contactor SFA Range* (A) SFA Range* (A) 200 V 230 V 460 V 600 V NEMA Size SFA SFA SFA SFA EPS3R-S1P-R-32 1-32 1-32 32 32 32 32 1+ EPS3R-S2-R-52 22-52 22-52 52 52 52 52 2 EPS3R-S3P-R-80 50-80 50-77 80 80 80 77 3+ * Use SFA Range or Max. SFA when sizing for submersible motor applications; if an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range ORDERING INFORMATION 3-Phase, 50/60 Hz, 200~600 VAC, NEMA Type 1 Enclosed - Standard Starter. Disconnect Not Included. 3-PHASE Max. SFA* Part No. 200 V - 460 V 600 V Contactor SFA Range* (A) SFA Range* (A) 200 V 230 V 460 V 600 V NEMA Size SFA SFA SFA SFA EPS1-S1P-R-32 1-32 1-32 32 32 32 32 1+ EPS1-S2-R-52 22-52 22-52 52 52 52 52 2 EPS1-S3P-R-80 50-80 50-77 80 80 80 77 3+ * Use SFA Range or Max. SFA when sizing for submersible motor applications; if an amperage value for SFA is not published on the motor nameplate, consider SFA range to be FLA range FACTORY INSTALLABLE OPTIONS (3R ONLY) Part No. Description EPS-HOA-KEY Keyed HOA Switch EPS-RPL-120V Run Pilot Light EPS-FPL-120V Fault Pilot Light EPS-SRG Surge Suppressor, Corner Grounded Power (up to 480V) EPS-SRG-240V Surge Suppressor, 200/230V EPS-SRG-480V Surge Suppressor, 460V EPS-SRG-600V Surge Suppressor, 600V EPS-2FC Float Switch Control Terminals 3

EPS-ECONOMY PUMP STARTER DIMENSIONS: NEMA 3R ENCLOSURE W Combination Starter Dimensions (in) H W D EPS3R-S0-R-GXX EPS3R-S0P-R-GXX EPS3R-S1-R-GXX EPS3R-S1P-R-GXX EPS3R-S2-R-GXX EPS3R-S3-R-GXX EPS3R-S3P-R-GXX 22 32 15 15 10 10 Standard Starter H W D EPS3R-S1P-R-32 EPS3R-S1P-R-32 EPS3R-S1P-R-32 16 12 8 W H D H D DIMENSIONS: NEMA 1 ENCLOSURE W Combination Starter Dimensions (in) H W D EPS3R-S0-R-GXX 16 7.5 6 EPS3R-S0P-R-GXX EPS3R-S1-R-GXX 16 12 8 H D W H D 4

EPS-ECONOMY PUMP STARTER WIRING DIAGRAM NEMA 1 NEMA 3R 5

EPS-ECONOMY PUMP STARTER SPECIFICATIONS Starter Type Standard or combination (service entrance rated) NEMA Type 1 or 3R Enclosed User Interface Settings Adjustments Internal Hand.Off.Auto NEMA 3R - door mounted switch, NEMA 1 - Keypad Standard Control Operations Input Auto Run N.O. dry contact closure Output Fault Relay N.O. 12-240 V Overload Type Electronic, I2T thermal trip curve Operational Fault Reset Manual Power Fail Modes Selectable: return to off mode or return to last mode (Hand/Off/Auto) Environmental Ambient Operating Temp -5 F to 140 F (-20 C to 60 C) Ambient Storage Temp -5 F to 185 F (-20 C to 85 C) Relative Humidity 5% to 95% non-condensing Motor Protection Adjustment / Description Default Setting Overload Current Setting Range Differs per model Per SFA Overload Trip Class Class S (Submersible) Always on Current Phase Unbalance Trips within 3 sec. @ 80% current unbalance. Always On 6

NOTES 7