Moulded Case Circuit Breakers

Similar documents
NEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A

About us. Switchgear Factory, Mumbai

Moulded Case Circuit Breakers

Motor Protection Circuit Breakers

Moulded case circuit breakers

L&T SWITCHGEAR S A F E & S U R E. Moulded Case Circuit Breakers


Moulded Case Circuit Breakers New DU Series 20 A to 250 A

About us. Switchgear Factory, Mumbai

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

MS General Information Extended Product Type: MS

cor Long Run Experience

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

MINIATURE CIRCUIT BREAKER

Fuse switch disconnectors

Miniature Circuit Breaker

01 Spectra Plus - Introduction

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

DPX earth leakage DPX 3 -I earth leakage

DPX Magnetic only

Protection components

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Fuse switch disconnectors

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

vertical fuse switch disconnectors

D509E. Manual Motor - Starters

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

3 - Protection components Motor circuit-breakers

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

Thermal Overcurrent Circuit Breaker 3120-F...

MOULDED CASE CIRCUIT BREAKERS BC160N

DPX 1600 Electronic release

Thermal Overcurrent Circuit Breaker 3120-F...

3VU13, 3VU16 Circuit-Breakers

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

Series KTU7 UL489 Molded Case Circuit Breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Manual Motor Starters. Meta-MEC

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.

Series KTU7 UL489 Molded Case Circuit Breakers

DPX moulded case circuit breakers

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

DPX Electronic + earth leakage

MS25, MST25, MS20, MST20

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Thermal magnetic and trip-free switches

DMX 3 -I 2500 switch disconnectors

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

15-I73E CAT REF.

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Low voltage moulded case circuit breaker EB2

Fuse switch-disconnectors

14-I73E CAT REF.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Thermal Overcurrent Circuit Breaker 3120-F...

TAE pole Contactors

Changeover & Bypass Sw it ches

Compact NR630. NR100F to NR630F

Perfection that Matters

Technical Data Accessories MCBs Ex9B.

NS Feeder pillar up to 3200A

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Motor Protection Circuit Breakers 3VU13 and 3VU16

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

3NP1 Fuse Switch Disconnectors up to 630 A

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

DPX 630 Electronic release

CIRCUIT BREAKERS MB CIRCUIT BREAKERS MB1 16 TO 125A CIRCUIT BREAKERS MB2 125 TO 250A MB1 AND MB2 ACCESSORIES CONNECTING COMPETENCE.

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Phone: Fax: Web: -

Thermal Overcurrent Circuit Breaker 3120-F...

Switch Disconnectors

Circuit Breakers Ex9M

Fuse switch-disconnectors

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Short form catalogue Motor protection and control Manual motor starters

Vistop TM isolating switches 63 to 160A

18-I73E CAT REF.

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

MPCB. We touch your electricity everyday! State of the art Manufacturing Facilities. Haridwar, Noida Ph-I & Noida Ph-II Plant

Transcription:

Moulded Case Circuit Breakers DU Series

About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction, Electrical & Automation, Machinery and Information Technology. L&T Switchgear, a part of the Electrical & Automation business, is India's largest manufacturer of low voltage switchgear, with the scale, sophistication and range to meet global benchmarks. With over five decades of experience in this field, the Company today enjoys a leadership position in the Indian market with a growing international presence. It offers a complete range of products including powergear, controlgear, industrial automation, building electricals & automation, reactive power management, energy meters, and protective relays. These products conform to Indian and International Standards. Switchgear Factory, Baroda Index Description Introduction Salient Features Technical Specifications IT Characteristics Curves Overall Dimensions Page o. 4

Introduction The DU Series, a new generation of MCCBs, stands out due to its stateoftheart design, contemporary userfriendly features, ergonomics, aesthetics and compactness. H/DU0 Series complies with the latest standards like IEC 947, E 947 & IS/IEC 947. The products conform to international standards, carry marking and are & CB certified. The range is specially designed for tropical conditions, ensuring reliable performance at high ambient and humid environments. The range can satisfy the most demanding system requirements. The DU Series, has a wide range of accessories, ensuring operational safety, reliability and versatility. Salient Features Technology Specially designed arc suction effect & speedo quench contact system o load line bias: Either side of MCCB terminal can be used as load and line* Ergonomic design & user friendliness Knob designed for better grip Color indication of O/TRIP/OFF* Current rating on the knob Overload adjustment from front* Easy O/OFF/RESET operations Wide variety of snap fit accessories* Compact Compact size Common depth throughout the range Suitable for side by side mounting Suitable for use in Distribution Board Internal Accessories Auxiliary contacts Trip alarm contacts* Combined Auxiliary + Trip alarm contacts* Shunt release Under Voltage release* External Accessories Direct & Extended ROM Spreader links Padlock is available (with ROM) SS Enclosure** GF module for earth fault protection Easy to Install 4mm door cutout* Optional DI rail mounting available** Safe to Use Finger proof terminals Lockable shroud on thermal knob to prevent unauthorized operation* marked range* Double Insulation: The internal accessories are housed in insulated casings to ensure first level of insulation. When the front cover is opened for the fixing of internal accessories, the MCCB is totally insulated ensuring the double insulation* * For H & DU0 P & 4P MCCBs ** For & H

Technical Specifications DU Series Technical Parameters Specification Type Designation H DU0 o. of Poles //4 /4 Rated Current I n (A) 16,0,,,40,0,6,80,0 0,,,40,0,6,80,0 0,1,1,00,0 Impulse withstand voltage U imp (kv) 6 Rated operational voltage U e (V) 41 Rated insulation voltage U i (V) 690 Operational frequency (Hz) 0 / Utilisation Category A Reference Temperature 0 0 C 40 C Operating Temperature C to + C 40V a.c. 6 6 I cu (ka) 41V a.c. 0V d.c (P in series) L/R<1 msec 0 1 6 1 00V d.c. (P in series) L/R<1 msec Rated Service S. C. Breaking Capacity (I cs) 0% of lcu Mechanical Life o. of operations 0000 0000 000 Electrical Life o. of operations 00 4000 000 IP Protection (from front side) Pollution Degree Type of Release Thermal Magnetic Terminal Capacity (without ) Fixed IP40 III Thermal Magnetic Fixed (9I n) Variable (0.8 1.0I n ) Cables with Lug ( mm ) 0 Link (mm) Overall Dimensions <17 <6 Width (mm) 7 7/7/0 /140 Height (mm) 16 Mounting Depth (mm) Weight (//4 Pole) (kg) 0.68 0.6/0.7/1 1.4/1.8

IT Characteristics Curves /H 000 00 0 Time in Seconds 1 0.1 0.01 0.001 1 1 Current multiples DU0 000 00 0 Time in Seconds 1 0.1 0.01 0.001 1 1 Current multiples 4

Pole Overall Dimensions Pole with 7 1. Pole H Pole, 4Pole Pole with 4Pole with Pole, 4Pole 1. 6.9 9 0 (4 pole) 7 ( pole) 9 17 86.1 6 61 Terminal 4. 116.4 For Pole MCCB, refer Pole dimensions. Spreader links are available as spare. It is recommended to use spreader links for enhancing termination capacity. Pole, 4Pole Pole with DU0 4Pole with Pole, 4Pole 18 16 14 16 7 1 16 14 16 8 11 1 11 171 19 4 7. 7 Screw M6 Terminal 7.4 Ø9 8 9 6 79.6 4 194. 17. 116.4 s s 0. 11 17 0.1 (P) 140 (4P) Spreader links are available as spare. It is recommended to use spreader links for enhancing termination capacity. 4. 7 4. 7 4 4 4 197 (P) 140 (4P) 64. 4 18 9.7 All dimensions are in mm

Panel Cutout Dimension H DU0 For Fixing the MCCB Use Screw M4x4 os. MF.4 Mounting Panel 70. 70. 1 6 47 11 46 9 9. 76. 48. Cutout 1 OR Cutout 16 141 8 4.6 8.6 46 eutral Pole Door Cutout Dimensions M4Ø. For Four Pole 8.8 ROM Mounting Dimension Direct ROM L L4 Type L L L4 L 1 L H 96. 8 44 7 Panel L Panel Cutout Breaker Mounting Holes DU0 96. 7 6. = Mounting Depth L/L = Panel Cutout L4/L = Breaker Mounting Reference Extended ROM MCCB Mounting Holes As Viewed From the Front References as per MCCB Mounting L L 4 Ø1 Ø76 Ø4 Panel Cut Details 7 Cut The Shaft to the Required Length = L L Type H DU0 169 169 L 119 119 L 7. 4. L 69. 81.7 L = Length of Shaft required for Panel Depth (mm) = Min. Panel depth (mm) All dimensions are in mm 6