RK-03, RK-HS-03, RK-OC-03, and RK-IR-03 Flow Through Adapters

Similar documents
Model Combustible Gas Sample Draw Detector Head Operator s Manual

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Model Combustible Gas Sample Draw Detector Head Operator s Manual

A Methane Sample-Draw Detector Operator s Manual

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual

Model GD-K7D2 (115 VAC) Sample Draw Detector Operator s Manual

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual

RK Standby Battery Operator s Manual

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

RK Standby Battery Operator s Manual

Installation Notes for Caterpillar 3516 Gen Set Package (Up to 255 Gallon Sump Capacity)

Water Meter & Flow Sensor

Ph: (07) Fax: (07) Pump Manual

Agilent 210/218 - Isocratic Pump

Part No: Genuine Mira Accessories

EVP SERIES PROPORTIONAL CONTROL VALVES

Technical Manual MSI Dart Check Valve

SOUND GUARD SST-E INSTALLATION INSTRUCTIONS & PARTS LIST

Pro-Swirl Manifold Air Heater

TECHNICAL INSTRUCTIONS

Product Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve

OWNER S TECHNICAL MANUAL

The PMI Dilution Probe for In-Situ Sample Conditioning of Stack Gases

EVAP system, servicing

Airsweep Installation & Maintenance Manual. Airsweep Models VA-06 VA-12 VA-51 SECTION THREE SOLENOID VALVES

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

Installation Notes for Caterpillar 3306/3456/C15 Gen Set Package. Caterpillar 3306/3456/C15 Generator Set Package. Puradyn Part # Description Qty

Installation Notes for CAT C32_27_3412 / MTU 16V2000 Gen Set Package. Caterpillar C32_27_3412 / MTU 16V2000 Generator Set Package

Hot Injection Adapter Kit - Installation Guide

TECHNICAL INSTRUCTIONS

Installation Instructions

INSTRUCTION MANUAL. CR Series A/B

DIAGNOSIS AND TESTING

Foss Electric Milko-Scope II Meter Manual

Agilent 210/218 - Binary Pump

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

9MP-DJ Powder Feeder HVOF Spraying. Parts List PL EN 06

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Manual No: Revision: F. Mag Probe Assembly Manual

1 MECHANICAL FUEL METER

DELTA O-RING CARTRIDGE SEAL ASSEMBLY AND INSTALLATION INSTRUCTIONS INTRODUCTION:

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance

Appendix D Outline Dimensions

SAN JUAN ENGINEERING & MANUFACTURING CO. 766 Marine Drive Bellingham, WA USA PH: (360) FAX: (360)

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE MOUNTED LIQUID ELIMINATOR

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

INSTALLATION INSTRUCTIONS FOR THE PHOENIX FIBER OPTIC FLAME SCANNERS

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

Operation and Maintenance Instructions

INSTALLATION INSTRUCTIONS Auto Level Compressor Kit IMPORTANT NOTES

Operating and Maintenance Manual for Type S Flowmeters. M101 Rev. B Type S Flowmeters: 5 8, 3 4 and 1 with 157 & 600 Series Registers

TECHNICAL INSTRUCTIONS

Warnings and Cautions

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

COMPRESSORS 09/97 CB-5C-050. Suggested Spare Parts for LB601 and LB601A Compressors: Qty./ Unit

Technical Instructions

Document: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370

Replacing the Internal Oil Filter Elements for HS85 and OS 85 Screw Compressors

Accessories. Section Outline

SERVICE INSTRUCTIONS Air Motor

DIT VALVE ASSEMBLY PARTS CATALOG

LB601B PARTS LIST COMPRESSORS CB-5E /06. Bulletins Needed For Complete Parts List. Gasket Set, Repair Kits and Special Tools

6890 Installing ¼ Glass Columns

1 Ent WITHOUT PUMP. 3 Loc. ld for three seconds to power. 4 Press and ho. onitor the gas. 5 Mo. Gas Detection Kit. ter Airlock.

Material Specifications

WDV-2 2-way normally closed poppet with air pilot. When valve closes a spring biased internal piston draws back a small volume on outlet side (approx.

PolAIR High Pressure Fog Cooling System. Important Installation Notes Please read before starting installation

To ensure proper installation, digital pictures with contact information to before startup.

1350 Valves. 1 of 14. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

Quick-start Guide. 1 Enter Airlock Locate pull tab on the back of the instrument. Pull to remove it and activate the battery. Wait 15 seconds.

Lube Level Maintainer

TECHNICAL INSTRUCTIONS

LTV VALVE APPLICATION INSTRUCTIONS FOR

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL

Proper Servicing of the Fuel Screens on Enstrom F Series Piston Engine Helicopters

INSTALLATION INSTRUCTIONS FOR THE 45RM1, 45RM2, 45RM4, 45FS1, 45UVFS1 FIBER OPTIC FLAME SCANNERS

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts

FUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS. by John Michalak Romet International, Inc.

Maintenance of the Electronic ( EPC ) Pressure Controllers on SRI GCs

SUPPLEMENTAL MANUAL FOR THE INSTALLATION, OPERATION AND MAINTENANCE OF THE XL234 FILTER VESSEL

HPS Two-Stage Vacuum Valve Instruction Manual Addendum - Bypass Valve Service

Installation Instructions

EP Series Electro-Pneumatic Preset Valve

Hydra-Cell T80 Series Pumps Design Advantages

Operation & Service Manual

Calibration and Switching Module. User s Manual. A Swagelok Pre-Engineered. Subsystem. Pre-engineered subsystems available in weeks, not months.

rings used in the TuckAway Electric Monitor (#3352)

LPM LP-Gas Flowmeter Product Bulletin L LISTED. Primary Features. Specifications 91U3

270A SERIES HIGH-SIDE FLOAT VALVES BULLETIN 270A-SB13-01 SERVICE BULLETIN

I-799/79V Coil Components

Item # Part # Description Item # Part # Description

Installation. Installation. 12. System Diagram... 10

TT /13b INSTALLATION INSTRUCTIONS. Introduction

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

Installation, Operation, and Maintenance Manual

SERVICE MANUAL 200 SERIES MOTORIZED 20352, 20452, 20551, 20552, AND MODELS

LABORATORY ZERO AIR GENERATOR MODEL N-GC1500 USER S MANUAL

BECSys CO 2 Feeder. BECSys CO 2 Feed System Data Sheet. Description. Features

Transcription:

30-0951RK-03, 30-0951RK-HS-03, 30-0951RK-OC-03, and 30-0951RK-IR-03 Flow Through Adapters Part Number: 71-0423 Revision: P1 Released: 4/6/17 www.rkiinstruments.com

Description The attached detector head operator s manual can be used in conjunction with this supplement for the 30-0951RK-03, 30-0951RK-HS-03, 30-0951RK-OC-03, or the 30-0951RK-IR-03 flow through adapter. The flow through adapter includes a flowmeter with an adjustment valve, a sensor adapter, and a sensor chamber with two compression fittings. A sensor adapter gasket seals to the 1/2 NPT combustible sensor when installed. A sensor adapter O-ring seals to all other types of detectors when installed. This O-ring is different for different types of detectors. A detector chamber O-ring seals the sensor chamber to the sensor adapter. This O-ring is the same for all versions. A flowmeter with an adjustment valve is installed in the inlet line. The flowmeter allows you to view and adjust the flow rate through the flow through adapter. Calibration instructions are the same as those outlined in the attached detector head manual with the exception that the calibration gas must be connected either to the inlet fitting tubing or to the pump inlet (if the flow through adapter is on the pressure side of the pump) as opposed to a calibration cup. Installation instructions are slightly different and are outlined below. 1

Installation Screw Onto Sensor Sensor Adapter O-Ring/Gasket Sensor Chamber O-Ring Sensor Adapter Quick Connect Fitting Sensor Chamber Thumbscrew, 3x 8.0 max 1/4 inch OD Tube Sample Exhaust Fitting 1/4 inch OD Tube Sample Inlet Fitting Flowmeter 5.3 max Figure 1: Outline and Mounting Dimensions/Component Location 1. The flow through adapter is normally shipped uninstalled from the detector and the flowmeter is separated from the sensor adapter. Insert the fitting at the top of the flowmeter into the quick connect fitting connected to the sensor adapter. Screw the flow through adapter onto the detector, tightening firmly by hand. CAUTION: Make sure the flow through adapter is installed tightly and after installation is complete, verify that the flow through adapter is still tightened firmly onto the detector to avoid possible leaks. 2. If necessary, re-orient the sensor chamber so the fitting from the sensor chamber to the flowmeter does not hit the mounting surface by unscrewing the three thumbscrews, 2

rotating the sensor chamber, and tightening the three thumbscrews. 3. Install and startup the detector head as described in the detector head operator s manual. Make sure there is sufficient room between the detector and the mounting surface for the flow through adapter. 4. The inlet and exhaust fittings accept 1/4 OD rigid metal tubing such as copper, aluminum, or stainless steel. The inlet fitting is located at the bottom of the flowmeter and the exhaust fitting is located on the bottom of the sensor chamber. Insert the desired length of tubing into each fitting and tighten the fittings so that the ferrules crimp onto the tubing. 5. Install appropriate device(s) (pump, aspirator, etc.) to draw sample to the detector. The ideal flow rate for the flow through adapter is 3.0 SCFH. If necessary, the valve on the flowmeter can be used to adjust the flow to 3.0 SCFH. NOTE: Be sure to use the inlet and exhaust ports as intended to ensure correct sensor response and to allow any accumulated liquid to drain out the bottom of the flow through adapter. 6. Calibrate the detector head as described in the attached manual and in the next section. NOTE: Calibrate the detector head with the flow through adapter installed to ensure an accurate reading. Calibration A demand flow regulator should be used for calibration. 1. Follow the calibration instructions outlined in the attached detector head manual. 2. When the instructions call for applying gas, connect the cylinder. If you are drawing sample through the system, connect the cylinder to the inlet fitting on the flowmeter. If you are pushing sample through the system, connect the cylinder to the pump inlet. 3. Perform a calibration as outlined in the attached detector head manual. 4. When the instructions call for removing the gas, disconnect the cylinder. 3

Parts List See the table below for spare parts not listed in the attached detector manual. Table 1: Parts List Part Number 07-0107RK 07-7123RK 07-7218RK 07-7225RK Description Gasket, 0.75 OD x 0.58 ID x 0.093 thick, for 1/2 NPT combustible sensor adapter O-ring, 1.174 ID x.103, buna, for O 2 /CO/CSA LEL sensor adapter O-ring, 0.734 x.139, buna, for IR and H 2 S sensor adapters O-ring, 1.243 ID x.139, buna, for sensor chamber 13-1070RK Captive panel screw, 10-32 x 1.75 81-1054RK 81-1055RK Regulator, demand flow, for 58- and 103-liter calibration cylinders Regulator, demand flow, for 17- and 34-liter calibration cylinders 4