DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Similar documents
DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

DV-5A Automatic Water Control Valve Remote-Resetting Deluge Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Worldwide Contacts.

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

Technical Data. UL Listing is based on the following criteria:

Preaction System with DV-5 Deluge Valve Double Interlock Electric/Electric Actuation. General Description. Page 1 of 14 DECEMBER 2014 TFP1465

DV-5 Deluge Valve Aluminium Bronze Diaphragm Style General Description

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

Instructions for Installation, Operation, Care and Maintenance

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

TECHNICAL DATA 1-1/2 (dn40)

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

TECHNICAL DATA. Q= C v P S

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

DELUGE VALVE DATA SHEET

TotalPac 3 Non interlock Preaction system Pneumatic release

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

Model RM-1 Riser Manifold Commercial and Residential General Description

with the specific application. Always read and understand the installation

TotalPac 3 Non interlock Preaction, Electric release Remote controlled system

Technical Data. Sizes 2 in. to 24 in. (DN50 to DN600) Approvals UL and ULC Listed FM Approved

MODEL RCW DELUGE SYSTEM ELECTRIC, WET PILOT, AND DRY PILOT ACTUATION

TotalPac 3 Deluge, Electric release Remote controlled system

TotalPac 3 Firecyle III Wet pipe Remote controlled system

TECHNICAL DATA. Trimpac 249a. September 16, 2013

TotalPac 3 Deluge system Pneumatic release

CJ=TN=- FRONT DELUGE VALVE, EXTERNAL RESETTING. MODEL F470 MULTIMATIW - 4 and 6 INCH (100 and 150 mm) a P il

Features 1. Differential Latch-type, lightweight, dependable

TECHNICAL DATA. Trimpac 244a. April 15, 2011

TotalPac 3 Double interlock Firecyle III Preaction Remote controlled system

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care, and Maintenance

AGCX Bulletin 519 C/Alfoz de Bricia nº4 P.l. Villalonquéjar Burgos (Spain) Tlfno: PAG 1 de 50

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

Wet pipe low flow foam/water manifold system

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

Series 758 FireLock Actuated System Valve

Model DDX Deluge Valve 8 (200mm) Features

Instructions for Installation, Operation, Care and Maintenance

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

Instructions for Installation, Operation Care and Maintenance

TECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.

Series 769 FireLock NXT Deluge Valve

Grooved Piping System for Fire Protection Services

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

Series 756 FireLock Dry System Check Valve

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

Q= C v P S. Flow control valve Model j-2 Halar coated

TECHNICAL DATA P S. Q= Cv MODEL E-2 DELUGE VALVE HALAR COATED ANGLE STYLE

Grooved Piping System for Fire Protection Services

TECHNICAL DATA 2-1/2-8 (dn65 - dn200)

Technical Data. Sizes 2 12 Inch (DN50 DN300)

FireFlex DUAL Single Interlock, Remote controlled system

Worldwide Contacts. Technical Data

TECHNICAL DATA OBSOLETE

Easy Riser swing check valve Models E-1 & F-1

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m

SHORTER. LIGHTER. MORE VERSATILE. 1 VALVE 10 TRIM CONFIGURATIONS 4" AND 6" MODEL RCW WATER CONTROL VALVE FOR DRY, PREACTION AND DELUGE APPLICATIONS

TECHNICAL DATA OBSOLETE. Inlet Type Outlet Type in mm. Thread Thread in. ANSI B Flanged Flanged in.

TECHNICAL DATA CAUTION

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL H-2 HALAR COATED 2 (DN50) - 6 (DN150)

TECHNICAL DATA. Q= C v P S. Table 1 - Valve Part Numbers and Specifications

Instructions for Installation, Operation, Care and Maintenance

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

FireLock NXT Actuated Valve with Preaction Trim. System No. Submitted By Spec Sect Para Location Date Approved Date

Section R Foam Systems

FIRE PROTECTION PRODUCTS

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Section R Foam Systems

GRINNELL Model B303 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Instructions for Installation, Operation, Care and Maintenance

Valves & Flow Control Components Valves & Flow Control Components

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

TECHNICAL DATA. Table Standard Materials

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

ALARM CHECK VALVE 3", 4" & 6" MODEL H-1 FLANGE/FLANGE 3" & 4" MODEL H-2 GROOVE/GROOVE 3", 4" & 6" MODEL H-3 FLANGE/GROOVE

MODEL UM UNIVERSAL MANIFOLD ASSEMBLY (With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6",165.1mm, 8"

Series 751 FireLock European Alarm Check Valve Stations

Instructions for Installation, Operation, Care and Maintenance 2 PSI (0,14 bar) Pneumatic Supervising Pressure with Electric Actuation

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division

In-Line Balanced Pressure Proportioner (ILBP) Proportioning Devices Model KBP

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Deep Well Pump Control Valve

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

Transcription:

Worldwide Contacts www.tyco-fire.com DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/ Inch to Inch (DN40 to DN00) General Description The TYCO DV-5a Automatic Water Control Valves are diaphragm type valves that can be used in single interlock preaction fire protection systems. When properly trimmed, the double seat design of the DV-5a Valve also provides actuation of fire alarms upon system operation. The diaphragm style design of the DV-5a Valve allows external resetting, providing for easy resetting of a deluge system without having to open a valve handhole cover to manually reposition a clapper and/or latch mechanism. Simply re-pressurizing the diaphragm chamber resets the valve. The DV-5a features internal and external coating of the valve to provide corrosion resistance. The external corrosion resistance of the epoxy coating permits the use of the DV-5a in corrosive atmospheres associated with many types of industrial processing plants and outdoor installations. The DV-5a Valves are offered with the DV-5a Valve and separately ordered semi-assembled trim shown in Figures 7,, and 9, or, for ease of installation, with the DV-5a Valve completely trimmed with or without a System Main Control Valve. The DV-5a Single Interlock Preaction System utilizes automatic sprinklers and a supplemental detection system. The supplemental detection system is comprised of wet pilot lines, dry pilot lines, or electric detection comprised of heat detectors, smoke detectors, manual pull stations, etc. Actuation of the detection system automatically operates (releases) the DV-5a Valve, allowing water to flow into the sprinkler piping system and to be discharged from any sprinklers that may subsequently open. IMPORTANT Refer to Technical Data Sheet TFP300 for warnings pertaining to regulatory and health information. End Connection Inlet Thread Groove Outlet Thread Groove Available End Connections and Weights lb (kg) 1-1/ (40) 6 (11,) 5 (11,3) (50) 5 (11,3) 5 (11,3) Flange Groove N/A N/A Flange Flange N/A N/A Typically, the system designer selects the detection components for a single interlock preaction system that will respond to a fire sooner than the automatic sprinklers. Consequently, the system will experience a minimal delay in water delivery over that for a wet pipe sprinkler system because the system will have essentially filled with water before a sprinkler operates. The DV-5a Valve with Single Interlock Preaction Trim automatically supervises the integrity of the overall system. Supervision is provided by monitoring a relatively low air pressure in the system via a low pressure alarm switch so as Nominal Valve Size ANSI Inches (DN) 3 (0) 4 (100) 6 (150) (00) N/A N/A N/A N/A 60 (7,) 66 (30,0) 7 (3,7) 95 (43,1) 106 (4,1) 116 (5,6) 177 (0,3) 190 (6,) 04 (9,5) 37 (14,3) 346 (157,0) 365 (165,6) to detect leaks in the system that otherwise would result in unwanted water discharge should the system operate in a fire condition. Supervised single interlock preaction systems are generally used to protect areas where there is danger of serious water damage that might result from damaged automatic sprinklers or piping. Typically, such areas include computer rooms, storage areas for valuable artifacts, libraries, and archives. Single interlock preaction systems are also effectively used to protect proper- Page 1 of 34 JANUARY 019 TFP145

TFP145 Page of 34 Item Description Qty. Nominal Valve Size ANSI Inch (DN) 1-1/ (DN40) (DN50) 3 (DN0) 4 (DN100) 6 (DN150) (DN00) P/N P/N P/N P/N P/N P/N 1 Valve Body 1 N/R N/R N/R N/R N/R N/R Diaphragm 1 54500000 54500000 545000030 545000040 545000060 54500000 3 Diaphragm Cover 1 N/R N/R N/R N/R N/R N/R 4 Hex Bolt, Short a 545100001 545100001 54510000 545100003 545100004 545100003 5 Hex Bolt, Long 545100011 545100011 54510001 545100013 545100014 545100015 6 Lift Washer b N/A N/A 54510001 5451000 54510003 5451000 7 Hex Nut 545100031 545100031 54510003 545100033 545100034 545100033 Hoist Ring 545100041 545100041 545100041 545100041 545100041 545100041 9 Flat Washer N/A N/A 54510004 54510005 54510006 54510005 NOTES: a. Hex Bolt, Short, Qty. 6 in 6 and inch (DN150 and DN00) assemblies b. Lift Washer not used in 1-1/ and inch (DN40 and DN50) assemblies c. N/R = Not Replaceable d. Order replacements parts only via Part Numbers given, do not replace Hex Bolt, Hex Nut, Lift Washer or Hoist Ring with common hardware parts 1 5 9 3 1 6 7 5 1-1/ AND INCH VALVES ONLY 3 7 1 3 4 4 6 9 7 5 1 FIGURE 1 DV-5a VALVE ASSEMBLY AND REPLACEMENT PARTS 6 AND INCH VALVES ONLY Nominal Valve Size ANSI Inches (DN) 3 (0) 4 (100) 6 (150) (00) ANSI B16.1 a (Class 15) Flange Drilling Specification Nominal Dimensions in Inches and (mm) ISO 7005- JIS B 10 (PN16) b (10K) AS 19 (Table E) A B N A B N A B N A B N 6.00 (15,4) 7.50 (190,5) 9.50 (41,3) 11.75 (9,5) 0.75 (19,0) 0.75 (19,0) 0. (,) 0. (,) 4 6.30 (160,0) 7.09 (10,0) 9.45 (40,0) 11.61 (95,0) 0.75 (19,0) 0.75 (19,0) 0.91 (3,0) 0.91 (3,0) 5.90 (150,0) 6.9 (175,0) 9.45 (40,0) 1 11.4 (90,0) 0.59 (15,0) 0.60 (15,0) 0.75 (19,0) 0.75 (19,0) 5.75 (146,0) 7.00 17,0) 9.5 (35) 1 11.50 (9,0) 0.71 (1,0) 0.71 (1,0) 0.7 (,0) 0.7 (,0) TABLE A FLANGE DRILLING SPECIFICATIONS 4 Dim. A Bolt Circle Diameter Dim. B Bolt Hole Diameter Qty. N Number of Bolt Holes NOTES: a. Same drilling as for ANSI B16.5 (Class 150) and ANSI B16.4 (Class 150) b. Same drilling as for BS 4504 Section 3. (PN16) and DIN 53 (PN16)

TFP145 Page 3 of 34 Port Port Description 1-1/ (DN40) Port Sizes, NPT Inch per ANSI B1.0.1 3 4 6 (DN50) (DN0) (DN100) (DN150) (DN00) P1 Diaphragm Chamber Supply 1/ 1/ 1/ 1/ 1/ 1/ P Water Supply Pressure & Alarm Test 1/ 1/ 1/ 1/ 1/ 1/ P3 Alarm Actuation 3/4 3/4 3/4 3/4 3/4 3/4 P4 Automatic Drain Valve 1/ 1/ 1/ 1/ 1/ 1/ P5 System Drain 3/4 3/4 3/4 3/4 3/4 3/4 P6 Main Drain 3/4 3/4 1-1/4 P7 System Air Supply 1/ 1/ 1/ 1/ 1/ 1/ SYSTEM OPEN TO ATMOSPHERE WATERFLOW TO SYSTEM VALVE WATERWAY DIAPHRAGM SEAT DIAPHRAGM CHAMBER DIAPHRAGM CHAMBER SUPPLY FROM UPSTREAM SIDE OF SHUT-OFF VALVE WATER SUPPLY SYSTEM AIR SUPPLY AUTOMATIC VALVE OPEN TO ATMOSPHERE WATER SUPPLY PRESSURE & ALARM TEST VALVE WATERWAY DIAPHRAGM CHAMBER OPEN TO ATMOSPHERE DIAPHRAGM RETRACTS OPENING VALVE WATERWAY WATERFLOW FROM WATER SUPPLY ALARM PORT WATERFLOW TO ALARM AUTOMATIC VALVE CLOSED FIGURE A SET CONDITION FIGURE B OPERATED CONDITION FROM SYSTEM RESIDUAL FROM SYSTEM VALVE WATERWAY DIAPHRAGM SEAT VALVE WATERWAY DIAPHRAGM CHAMBER OPEN TO ATMOSPHERE SYSTEM OPEN DIAPHRAGM AUTOMATICALLY FLEXES TO ITS SEATED POSTION SYSTEM OPEN WATER SUPPLY SHUT OFF FIGURE C SYSTEM CONDITION MAIN OPEN DIAPHRAGM CHAMBER SUPPLY FROM UPSTREAM SIDE OF SHUT-OFF VALVE FIGURE DV-5a VALVE OPERATION, PREACTION SYSTEMS WATER SUPPLY SHUT OFF FIGURE D RESIDUAL CONDITION MAIN CLOSED

TFP145 Page 4 of 34 DIMENSIONS SHOWN ARE APPLICABLE TO ALL END CONNECTION CONFIGURATIONS AVAILABLE PER VALVE SIZE 10-3/16" (60 mm) 1-1/ Inch (DN40) 10-3/16" (60 mm) Inch (DN50) 13-3/4" (349 mm) 3 Inch (DN0) 16-3/4" (45 mm) 4 Inch (DN100) -3/" (569 mm) 6 Inch (DN150) 7-7/16" (697 mm) Inch (DN00) FIGURE 3 DV-5a VALVE TAKE-OUT DIMENSIONS ties where a pre-alarm of a possible fire condition may allow time for fire extinguishment by alternate suppression means, prior to a sprinkler discharge. In the event the fire cannot otherwise be extinguished, the preaction sprinkler system will then perform as the primary fire protection system. NOTICE The DV-5a Valves with Single Interlock Preaction Trim described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. Technical Data Approvals UL and C-UL Listed FM Approved Listing and Approvals are based on DV-5a Valve being trimmed as described in Figures 7,, and 9 (i.e., Wet Pilot, Dry Pilot, and Electric Actuation). DV-5A Valve Components for the 1-1/ Inch to Inch (DN40 to DN00) DV-5a Valves are shown in Figure 1. The DV-5a Valves are for vertical installations. They are rated for use at service pressures of 0 to 300 psi (1,4 to 0,7 bar). The take-out dimensions are shown in Figure 3, and flanged connections are available drilled per ANSI, ISO, AS, and JIS specifications (Ref. Table A). Threaded inlet and outlet connections are available in NPT or ISO 7/1. Threaded port connections are NPT threaded. NOTE: PN16 flanges are pressure rated to 16 bar. Valve Trim The maximum pressure rating is as follows: Single Interlock Preaction trim Wet Pilot Actuation is 300 psi (0,7 bar) Single Interlock Preaction trim Dry Pilot Actuation is 50 psi (17, bar) Single Interlock Preaction trim Electric Actuation is dependent on separately ordered solenoid valve per Technical Data Sheet TFP10 When the system pressure is greater than 175 psi (1,1 bar), provision is to be made to replace the standard order 300 psi (0,7 bar) Water Pressure Gauges with separately ordered 600 psi (41,4 bar) Water Pressure Gauges. If the addition of an Alarm Control Valve is desired or required by the local AHJ, the Alarm Control Valve noted as Item H in Figures 16, 17, and 1 is to be a separately ordered electronically supervised normally open valve. External trim connections are NPT threaded. EMEA trim is provided with NPT x ISO 7/1 thread adapters. Pressure Loss See Graph A Detection System See subsections Wet Pilot Actuation, Dry Pilot Actuation, or Electric Actuation, as necessary. System Air Pressure Requirements The supervisory air (nitrogen) pressure is to be 10 ± psi (0,69 plus or minus 0,07 bar). The use of a higher supervisory pressure is subject to approval by the authority having jurisdiction, and it should be understood that the use of a higher supervisory pressure may increase water delivery time. The use of a lower supervisory pressure may prevent clearing the alarm of the Supervisory Low Pressure Switch (Item T - Figures 16, 17, and 1), which is factory set to alarm at 5 ± 1 psi (0,34 ± 0,07 bar) on decreasing pressure. The supervisory air supply pressure of 10 ± psi (0,69 ± 0,07 bar) can be provided by any of the following methods. Refer to the applicable data sheet for laboratory approval information. Model G16AC1 (self contained) Automatic Supervisory Air Supply described in Technical Data Sheet TFP160. A maximum 00 psi (13, bar) plant air supply in combination with the Model AMD-1 Air Maintenance Device described in Technical Data Sheet TFP11. A maximum 3000 psi (06,9 bar) nitrogen cylinder in combination with the Model AMD-3 Nitrogen Maintenance Device described in Technical Data Sheet TFP141. NOTE: The dew point of the air or nitrogen supply for a system exposed to freezing conditions must be maintained below the lowest ambient temperature to which the system piping

TFP145 Page 5 of 34 FLOW RATE IN LITERS PER MINUTE (LPM) (1 GPM = 3,75 LPM) 00 400 600 1000 000 3000 5000 7000 10000 15000 9.0.0 7.0 0,600 0,500 NOMINAL PRESSURE DROP IN POUNDS PER SQUARE INCH (PSI) 6.0 5.0 4.0 3.0.0 1.0 0.9 0. 0.7 0.6 0.5 0.4 1-1/ INCH (DN40) INCH (DN50) 3 INCH (DN0) 4 INCH (DN100) 6 INCH (DN150) INCH (DN00) 0,400 0,300 0,00 0,100 0,090 0,00 0,070 0,060 0,050 0,040 0,030 NOMINAL PRESSURE DROP IN BAR (1 PSI = 0,0695 BAR) 0.3 50 100 will be exposed. Introduction of moisture into the system piping can create ice build-up that could prevent proper operation of the system. The Supervisory Low Pressure Switch (Item T - Figs. 16, 17, 1) is factory set at 5 ± 1 psi (0,34 ± 0,07 bar) on decreasing pressure. The Pressure Relief Valve (Item S- Figs. 16, 17, 1) is factory set to fully open at 5 ± psi (1,7 ± 0,14 bar) and it begins to crack open at a pressure of about 1 psi (1,4 bar). Materials of Construction Body Epoxy coated ductile iron per ASTM A536-77, Grade 65-45-1 Handhole Cover Epoxy coated ductile iron per ASTM A536-77, Grade 65-45-1 00 400 600 1000 000 3000 FLOW RATE IN GALLONS PER MINUTE (GPM) GRAPH A DV-5a VALVE NOMINAL PRESSURE LOSS VERSUS FLOW Diaphragm Polyester fabric reinforced, TEFLON coated, EPDM rubber per ASTM D000 Diaphragm Cover Fasteners Aluminum zinc coated steel Common Hardware Trim Common hardware pipe fittings are galvanized or black as required and are malleable per ASME B16.3. Common hardware pipe nipples are galvanized or black as required and are Schedule 40 per ASTM A53 or A135. Common hardware compression fittings are brass per ASTM B16. Common hardware tubing is Type L copper per ASTM B. 4000 Operation 0,0 The TYCO DV-5a Valve is a diaphragm style valve that depends upon water pressure in the Diaphragm Chamber (Ref. Figure A) to hold the Diaphragm closed against the water supply pressure. When the DV-5a Valve is set for service, the Diaphragm Chamber is pressurized through the trim connections from the inlet side of the system s main control valve. Opening an actuation device, for example the solenoid valve in the Electric Actuation Trim (Ref. Figure 6), trips the Model MRA-1 Manual Reset Actuator. Tripping the MRA-1 releases water from the DV-5a Diaphragm Chamber faster than it can be replenished through a 1/ in. (3, mm) restriction located in the Diaphragm Chamber Supply Connection. Release of water through the MRA-1 results in a rapid pressure drop in the DV-5a Diaphragm

TFP145 Page 6 of 34 SYSTEM PIPING WITH AUTOMATIC SPRINKLERS - NORMALLY DRY INSPECTOR'S TEST CONNECTION (AT MOST HYDRAULICALLY DEMANDING LOCATION OF WET PILOT LINE) WET PILOT SPRINKLER DETECTION SYSTEM (MINIMUM 1/" PIPE AND AUTOMATIC SPRINKLERS) REMOTE MANUAL CONTROL STATION (WHEN SPECIFIED) AUTOMATIC SUPERVISORY AIR/NITROGEN SUPPLY TO 1 PSI WATERFLOW PRESSURE ALARM SWITCH DIAPHRAGM CHAMBER PRESSURE GAUGE DV-5A VALVE SYSTEM VALVE (NORMALLY CLOSED) MAIN VALVE (NORMALLY CLOSED) SUPERVISORY LOW PRESSURE ALARM SWITCH SYSTEM AIR PRESSURE GAUGE DIAPHRAGM CHAMBER SUPPLY CONTROL VALVE (NORMALLY OPEN) RESTRICTION MANUAL RESET ACTUATOR DIAPHRAGM CHAMBER SUPPLY CONNECTION WATER SUPPLY PRESSURE GAUGE WATER SUPPLY LOCAL MANUAL CONTROL STATION MAIN CONTROL VALVE (NORMALLY OPEN) FIGURE 4 DV-5a VALVE - SINGLE INTERLOCK PREACTION WET PILOT ACTUATION SCHEMATIC DIAGRAM Chamber. The force differential applied through the Diaphragm to hold the Diaphragm in the set position is then reduced below the valve trip point. The water supply pressure then forces the Diaphragm open permitting water to flow into the system piping, as well as through the Alarm Port to actuate the system alarms (Ref. Figure B). Upon opening of the DV-5a Valve, the Model MRA-1 Manual Reset Actuator opens to constantly vent the DV-5a Diaphragm Chamber to hydraulically latch the DV-5a in the tripped position until manually reset. In standby mode, the integrity of the system piping is supervised by a low pressure alarm switch. See the following three sections for additional information regarding actuation options: Wet Pilot Actuation Dry Pilot Actuation Electric Actuation Wet Pilot Actuation The Wet Pilot Actuation Trim forms a part of the laboratory approval of the DV-5a Valves and is necessary for their proper operation. With reference to Figure 4, the Wet Pilot Actuation Trim provides for connection of a detection system consisting of wet pilot line sprinklers (heat detectors) and Manual Control Stations interconnected with minimum 1/ in. (DN15) steel pipe. The pilot line is connected to the Wet Pilot Line Connection. Dimensions are provided in Figure 13. Pilot sprinklers are to be minimum 5.6 K-factor (0 K-factor) orifice approved automatic sprinklers. Manual Control Stations are to be the Model MC-1 described in Technical Data Sheet TFP13. NOTE: For Single Interlock Preaction Systems with Wet Pilot Actuation, the system designer typically selects wet pilot sprinklers that will operate sooner than the automatic sprinklers chosen for use on the sprinkler piping. The maximum height of a wet pilot line above the DV-5a Valve must not exceed the limitations shown in Table B as a function of the minimum water supply pressure to the DV-5a Valve for an equivalent length (pipe plus fittings) of the pilot line up to 500 ft (150 meters) to the most remote pilot sprinkler. Provision must be made for installing a 5.6 K-factor (0 K-factor) orifice, Inspector s Test Connection at the most hydraulically demanding location of a wet pilot line (usually adjacent to the highest and most remote wet pilot sprinkler or Manual Control Station). NOTES: Wet Pilot Lines must be maintained at a minimum temperature of 40 F (4 C). At a minimum, it is recommended that internally galvanized pipe and fittings be used for wet pilot lines.

TFP145 Page 7 of 34 SYSTEM PIPING WITH AUTOMATIC SPRINKLERS - NORMALLY DRY INSPECTOR'S TEST CONNECTION (AT MOST REMOTE LOCATION FROM DV-5A VALVE) LOW PRESSURE ALARM SWITCH DRY PILOT ACTUATOR DRY PILOT SPRINKLER DETECTION SYSTEM (MINIMUM 1/" PIPE AND AUTOMATIC SPRINKLERS) REMOTE MANUAL CONTROL STATION (WHEN SPECIFIED) AUTOMATIC AIR/NITROGEN MAINTENANCE DEVICE AUTOMATIC SUPERVISORY AIR/NITROGEN SUPPLY TO 1 PSI WATERFLOW PRESSURE ALARM SWITCH DIAPHRAGM CHAMBER PRESSURE GAUGE DV-5A VALVE SYSTEM VALVE (NORMALLY CLOSED) MAIN VALVE (NORMALLY CLOSED) SUPERVISORY LOW PRESSURE ALARM SWITCH SYSTEM AIR PRESSURE GAUGE DIAPHRAGM CHAMBER SUPPLY CONTROL VALVE (NORMALLY OPEN) RESTRICTION MANUAL RESET ACTUATOR DIAPHRAGM CHAMBER SUPPLY CONNECTION WATER SUPPLY PRESSURE GAUGE WATER SUPPLY LOCAL MANUAL CONTROL STATION MAIN CONTROL VALVE (NORMALLY OPEN) FIGURE 5 DV-5a VALVE - SINGLE INTERLOCK PREACTION DRY PILOT ACTUATION SCHEMATIC DIAGRAM Dry Pilot Actuation The Dry Pilot Actuation Trim forms a part of the laboratory approval of the DV-5a Valves and is necessary for their proper operation. With reference to Figure 5, the Dry Pilot Actuation Trim provides for installation of a detection system consisting of pilot sprinklers (heat detectors) and Manual Control Stations interconnected with a minimum length of 56 ft (17,1 m) of 1/ in. (DN15) steel pipe equivalent to 07 in. 3 (3400 cm 3 ). The dry pilot line, which is to be pressurized with air or nitrogen, is connected to the Dry Pilot Line Connection. Dimensions are provided in Figure 14. Pilot sprinklers are to be minimum 5.6 K-factor (0 K-factor) orifice approved automatic sprinklers. Manual Control Stations are to be the Model MC-1 described in Technical Data Sheet TFP13. NOTE: For Single Interlock Preaction Systems with Dry Pilot Actuation, the system designer typically selects dry pilot sprinklers that will operate sooner than the automatic sprinklers chosen for use on the sprinkler piping. Provision must be made for installing a 5.6 K-factor (0 K-factor) Inspector's Test Connection at the most remote location on the dry pilot line. The Dry Pilot Actuation Trim is provided with a Model DP-1 Dry Pilot Actuator, which is described in Technical Data Sheet TFP130. The Actuator is rated for use at a maximum pilot service pressure of 50 psi (3,4 bar) and a maximum water supply service pressure of 50 psi (17, bar). Graph B shows the minimum pilot line service pressure as a function of the water supply pressure. The pressure in the dry pilot actuation system must be automatically maintained using one of the following maintenance devices, as appropriate. Model AMD-1 Air Maintenance Device (pressure reducing type), refer to Technical Data Sheet TFP11 Model AMD- Air Maintenance Device (compressor control type), refer to Technical Data Sheet TFP131 Model AMD-3 Nitrogen Maintenance Device (high pressure reducing type), refer to Technical Data Sheet TFP141 Supervision of the pressure in the dry pilot actuation system and an alarm that separately indicates operation of the detection system is provided by a Low Pressure Alarm Switch set as follows: Low pressure alarm setting at approximately 6 psi (0,4 bar) below the minimum pilot line service pressure requirement shown in Graph B Fire alarm setting at approximately 15 psi (1,0 bar) below the minimum pilot line service pressure requirement shown in Graph B The Dry Pilot Air Pressure Relief Valve provided in the trim is factory set to relieve at a pressure of approximately 45 psi (3,1 bar); however, it may be field adjusted to a lower pressure, if required. The dry pilot line is to be provided with low point drains to enable draining of condensate. Note: At a minimum, it is recommended that internally galvanized pipe and cast iron fittings be used for dry pilot lines.

TFP145 Page of 34 SYSTEM PIPING WITH AUTOMATIC SPRINKLERS - NORMALLY DRY DELUGE VALVE RELEASING PANEL (AUTOMATIC CONTROL UNIT WITH BATTERY BACK-UP) POWER SUPPLY (TYPICALLY 10 VOLTS AC) ELECTRIC DETECTION SYSTEM (TYPICALLY 4 VOLTS DC) HEAT DETECTORS, SMOKE DETECTORS, MANUAL PULL STATIONS, ETC. AUTOMATIC SUPERVISORY AIR/NITROGEN SUPPLY TO 1 PSI WATERFLOW PRESSURE ALARM SWITCH DIAPHRAGM CHAMBER PRESSURE GAUGE DV-5A VALVE SOLENOID VALVE (TYPICALLY 4 VOLTS DC) SYSTEM VALVE (NORMALLY CLOSED) MAIN VALVE (NORMALLY CLOSED) SUPERVISORY LOW PRESSURE ALARM SWITCH SYSTEM AIR PRESSURE GAUGE DIAPHRAGM CHAMBER SUPPLY CONTROL VALVE (NORMALLY OPEN) RESTRICTION MANUAL RESET ACTUATOR DIAPHRAGM CHAMBER SUPPLY CONNECTION WATER SUPPLY PRESSURE GAUGE WATER SUPPLY LOCAL MANUAL CONTROL STATION MAIN CONTROL VALVE (NORMALLY OPEN) FIGURE 6 DV-5a VALVE - SINGLE INTERLOCK PREACTION ELECTRIC PILOT ACTUATION SCHEMATIC DIAGRAM Electric Actuation The Electric Actuation Trim forms a part of the laboratory approval of the DV-5a Valves and is necessary for their proper operation. The Electric Actuation Trim is required for electric operation of the DV-5a Valve by a detection system consisting of electrical devices such as heat sensitive thermostats, smoke detectors, and/or electric manual pull stations as shown in Figure 6. NOTE: For Single Interlock Preaction Systems with Electric Actuation, the system designer typically selects electric detection devices that will operate sooner than the automatic sprinklers chosen for use on the sprinkler piping. Dimensions are provided in Figure 15. NOTES: The normally closed, deenergized, Solenoid Valve is separately ordered and selected based on the required laboratory approval acceptable to the authority having jurisdiction. Refer to Technical Data Sheet TFP10 for specific laboratory approvals. Consult with the applicable standards of the Approval agency regarding installation criteria pertaining to electric actuation circuitry. Due to the functionality of the Model MRA-1 Manual Reset Actuator, the release circuit of the releasing panel need only provide the typical ten minutes of alarm condition intended to energize the Solenoid Valve to open. After the ten minute duration, at which point should the Solenoid Valve become de-energized and close (especially while operating under battery back-up), the MRA-1 will have already automatically opened, thereby preventing the DV-5a Diaphragm Chamber from becoming re-pressurized, and preventing an inadvertent closing of the DV-5a during a fire event.

TFP145 Page 9 of 34 AIR PRESSURE IN PSI 45 30 15 0 0 60 MINIMUM SYSTEM AIR PRESSURE RANGE OF ACTUATOR OPENING PRESSURE 100 140 10 00 50 WATER SUPPLY PRESSURE IN PSI NOTES: The dew point of the pilot line air pressure must be maintained below the lowest ambient temperature to which the dry pilot actuation system will be exposed. Accumulation of water in the pilot line connection to the Actuator will lower the air pressure at which the actuator will open and possibly prevent proper operation. Also, introduction of moisture into the pilot lines exposed to freezing temperatures can create an ice buildup that could prevent proper operation of the Actuator. An air dryer must be installed where the moisture content of the air supply is not properly controlled at less than the required value. It is recommended that an AMD-3 Nitrogen Maintenance Device be utilized in dry pilot actuation system applications where the dew point must be maintained below -0 F (-9 C). Refer to Technical Data Sheet TFP141. GRAPH B DV-5a VALVE SINGLE INTERLOCK PREACTION SYSTEM DRY PILOT LINE AIR PRESSURE REQUIREMENTS Supply Pressure psi (bar) 1 0 (1,4) 40 (,) 60 (4,1) 0 (5,5) 100 (6,9) 10 (,3) 140 (9,7) 160 (11,0) 175 (1,1) 00 (13,) 5 (15,5) 50 (17,) 75 (19,0) 300 (0,7) 1-1/ (DN40) 13 (4) 34 (10) 55 (17) 76 (3) 97 (30) 11 (36) 139 (4) 160 (49) 17 (5) 01 (61) 6 (69) 5 (77) 77 (4) 303 (9) (DN50) 13 (4) 34 (10) 55 (17) 76 (3) 97 (30) 11 (36) 139 (4) 160 (49) 17 (5) 01 (61) 6 (69) 5 (77) 77 (4) 303 (9) Maximum Pilot Height Feet (Meters) 3 (DN0) 4 (1) 9 (9) 54 (16) 79 (4) 103 (31) 1 (39) 153 (47) 17 (54) 1 (57) 03 (6) 19 (67) 35 (7) 47 (75) 66 (1) 4 (DN100) 9 (3) 33 (10) 57 (17) 1 (5) 105 (3) 19 (39) 153 (47) 177 (54) 195 (59) 4 (6) 54 (77) 4 (7) 30 (94) 347 (106) Notes: 1. If supply pressure is variable, assume minimum expected value.. Maximum pilot height for up to 500 ft (150 m) of equivalent length of pilot line (pipe plus fittings). 3. Interpolation between data points is permitted. 6 (DN150) TABLE B DV-5A VALVE SINGLE INTERLOCK PREACTION SYSTEM WET PILOT DESIGN CRITERIA FOR UP TO 500 FEET (150 METERS) OF EQUIVALENT LENGTH OF 1/ INCH (DN15) PILOT LINE (PIPE PLUS FITTINGS) 1 (4) 7 () 4 (13) 57 (17) 73 () (7) 103 (31) 11 (36) 131 (40) 15 (4) 173 (53) 195 (59) 1 (65) 37 (7) 0 (DN00) 15 (5) 3 (7) 31 (9) 39 (1) 46 (14) 54 (16) 6 (19) 70 (1) 75 (3) 4 (6) 9 () 100 (30) 107 (33) 14 (3)

TFP145 Page 10 of 34 Installation The TYCO DV-5a Valve is to be installed in accordance with this section. NOTICE Proper operation of the DV-5a Valves depends upon their trim being installed in accordance with the instructions given in this technical data sheet. Failure to follow the appropriate trim diagram may prevent the DV-5a Valve from functioning properly, as well as void approvals and the manufacturer s warranties. The DV-5a Valve must be installed in a readily visible and accessible location. The DV-5a Valve, associated trim, and wet pilot lines must be maintained at a minimum temperature of 40 F (4 C). Heat tracing of the DV-5a Valve or its associated trim is not permitted. Heat tracing can result in the formation of hardened mineral deposits that are capable of preventing proper operation. The DV-5a Valve is to be installed in accordance with the following criteria: Step 1. All nipples, fittings, and devices must be clean and free of scale and burrs before installation. Use pipe thread sealant sparingly on male pipe threads only. Step. The DV-5a Valve must be trimmed in accordance with one of the trim illustrations shown in Figures 7,, and 9, as applicable. Note: If the addition of an Alarm Control Valve is desired or required by the local AHJ, the Alarm Control Valve noted as Item H in Figures 16, 17, and 1 is to be a separately ordered electronically supervised normally open valve. Step 3. Care must be taken to ensure that check valves, strainers, globe valves, etc. are installed with the flow arrows in the proper direction. Step 4. Drain tubing to the Drip Funnel must be installed with smooth bends that will not restrict flow. Step 5. The Main Drain and Drip Funnel Drain may be interconnected provided a check valve is located at least 1 inches (300 mm) below the Drip Funnel. Step 6. Suitable provision must be made for disposal of drain water. Drainage water must be directed such that it will not cause accidental damage to property or danger to persons. Step 7. Connect the Diaphragm Supply Valve to the inlet side of the System Main Control Valve in order to facilitate setting of the DV-5a Valve (Ref. Figures 16, 17, and 1, as applicable). Step. An Inspector s Test Connection, as described in the Wet Pilot Actuation and Dry Pilot Actuation sections, must be provided for Wet or Dry Pilot Actuation systems. Step 9. An Air Maintenance Device, as described in the Dry Pilot Actuation section, must be provided for Dry Pilot Actuation. Step 10. A desiccant dryer, when specified for Dry Pilot Actuation, is to be installed between a drip leg and the Air Maintenance Device. Step 11. The Low Pressure Alarm Switch for Dry Pilot Actuation is to be adjusted as follows: Low pressure alarm setting at approximately 6 psi (0,4 bar) below the minimum pilot line service pressure requirement shown in Graph B Fire alarm setting at approximately 15 psi (1,0 bar) below the minimum pilot line service pressure requirement shown in Graph B Step 1. Unused Pressure Alarm Switch connections must be plugged. Step 13. The Dry Pilot Pressure Relief Valve (Item Y - Fig. 17) provided with the Dry Pilot Actuation Trim is factory set to relieve at a pressure of approximately 45 psi (3,1 bar), which can typically be used for a maximum dry pilot actuation system pressure of 40 psi (, bar). The Pressure Relief Valve may be reset; however, it must be reset to relieve at a pressure which is in accordance with the requirements of the authority having jurisdiction. To reset the Dry Pilot Pressure Relief Valve, first loosen the jam nut and then adjust the cap accordingly, clockwise for a higher pressure setting or counter clockwise for a lower pressure setting. After verifying the desired pressure setting, tighten the jam nut. Step 14. A suitable automatic supervisory air (nitrogen) supply, as described in the Technical Data section, is to be installed in accordance with the applicable technical data sheet and set for 10 ± psi (0,69 ± 0,14 bar). Step 15. A desiccant dryer, when required for the supervisory air supply, is to be installed between a drip leg and the Model AMD-1 Air Maintenance Device or between the Model G16AC1 Automatic Supervisory Air Supply and the Preaction Trim. Step 16. The Supervisory Low Pressure Switch is to be wired to the supervisory alarm initiating circuit of an alarm panel. Step 17. Conduit and electrical connections are to be made in accordance with the applicable standards of the approval agency. Step 1. Before a system hydrostatic test is performed, the DV-5a Diaphragm Chamber is to be depressurized, the Automatic Drain Valve is to be temporarily replaced with a plug, and the Diaphragm Cover Bolts must be uniformly and securely tightened using a cross-draw sequence. After tightening, double-check to make certain that all of the Diaphragm Cover Bolts are securely tightened. See Table C in the Care and Maintenance section for torque specifications. NOTE: When installing dry pilot actuation, the system will require two automatic air supplies as described in Steps 9 and 14.

TFP145 Page 11 of 34 A C6 L C D C4 A P7 P5 P4 A F E C J C5 H G P3 P P6 A1 P1 A4 C7 B C C3 A3 K A6 A4 A5 C1 1-1/" (DN40) AND " (DN50) VALVES ONLY Assemble in order from A to L A7 A Notes: 1. Port Connections P1 through P7 are described in Figure.. External Trim Connections C1 through C5 are described in Figure 16. 3. When ordering pre-assembled "DV-5A Valve with Galvanized Valve Trim" or pre-assembled "DV-5A Valve with Galvanized Valve Trim and Butterfly Valve", Items A1 through A are provided, as applicably related to valve size. 4. When ordering DV-5A Trim separately from the DV-5A Valve, Items A1 through A are separately ordered, as applicably related to valve size. Water Pressure Gauges for EMEA valve trim are also separately ordered. FIGURE 7 DV-5a VALVES WITH SINGLE INTERLOCK PREACTION WET PILOT ACTUATION TRIM SEMI-ASSEMBLED

TFP145 Page 1 of 34 A C7 L C D C5 C A J C6 H G P3 P P7 P4 P5 P6 A1 P1 A5 A C F B E C9 C7 M A3 C3 C4 A4 K A7 A5 A6 C1 1-1/" (DN40) AND " (DN50) VALVES ONLY Assemble in order from A to M A A9 Notes: 1. Port Connections P1 through P7 are described in Figure.. External Trim Connections C1 through C5 are described in Figure 17. 3. When ordering pre-assembled "DV-5A Valve with Galvanized Valve Trim" or pre-assembled "DV-5A Valve with Galvanized Valve Trim and Butterfly Valve", Items A1 through A9 are provided, as applicably related to valve size. 4. When ordering DV-5A Trim separately from the DV-5A Valve, Items A1 through A9 are separately ordered, as applicably related to valve size. Water Pressure Gauges for EMEA valve trim are also separately ordered. FIGURE DV-5a VALVES WITH SINGLE INTERLOCK PREACTION DRY PILOT ACTUATION TRIM SEMI-ASSEMBLED

TFP145 Page 13 of 34 A C5 L C D C3 A P7 P5 P4 A F E C J C4 H G P3 P P6 A1 P1 A4 C6 B C7 A6 A3 K A7 A4 A5 C1 1-1/" (DN40) AND " (DN50) VALVES ONLY Assemble in order from A to L A A9 Notes: 1. Port Connections P1 through P7 are described in Figure.. External Trim Connections C1 through C5 are described in Figure 1. 3. When ordering pre-assembled "DV-5A Valve with Galvanized Valve Trim" or pre-assembled "DV-5A Valve with Galvanized Valve Trim and Butterfly Valve", Items A1 through A9 are provided, as applicably related to valve size, and Item A6 is provided as P/N 5-7-1-14 described in Technical Data Sheet TFP10. 4. When ordering DV-5A Trim separately from the DV-5A Valve, Items A1 through A9 are separately ordered, as applicably related to valve size. Water Pressure Gauges for EMEA valve trim are also separately ordered. FIGURE 9 DV-5a VALVES WITH SINGLE INTERLOCK PREACTION ELECTRIC ACTUATION TRIM SEMI-ASSEMBLED

TFP145 Page 14 of 34 C6 39 A 7 36 A C5 C 3 5 44 P3 3 3 P 47 19 49 3 55 31 35 5 7 1 1 37 7 19 A4 A5 A6 P7 A4 A3 C1 4 A7 P5 P6 P1 P4 A1 54 33 C7 A 1-1/" (DN40) AND " (DN50) VALVES ONLY 9 13 53 0 7 37 7 0 37 4 5 11 37 6 50 7 51 4 43 41 1 45 17 9 14 C C3 4 4 16 39 15 40 5 57 55 1 9 1 36 36 36 6 3 46 C4 56 1 34 30 10 31 Notes: 1. Port Connections P1 through P7 are described in Figure.. External Trim Connections C1 through C5 are described in Figure 16. 3. When ordering preassembled "DV-5A Valve with Galvanized Valve Trim" or pre-assembled "DV-5A Valve with Galvanized Valve Trim and Butterfly Valve", Items A1 through A are provided, as applicably related to valve size. 4. When ordering DV-5A Trim separately from the DV-5A Valve, Items A1 through A are separately ordered, as applicably related to valve size. Water Pressure Gauges for EMEA valve trim are also separately ordered. ITEM QTY. DESCRIPTION CH 1-1/ IN. (DN40) IN. (DN50) 3 IN. (DN0) 4 IN. (DN100) 6 IN. (DN150) IN. (DN00) 1 1/4" GAUGE TEST VALVE 460051003 460051003 460051003 460051003 460051003 460051003 1 MRA-1 MANUAL RESET ACTUATOR 545001000 545001000 545001000 545001000 545001000 545001000 3 1 MC- MANUAL CONTROL STATION 54500000 54500000 54500000 54500000 54500000 54500000 4 1 AD-3 AUTOMATIC VALVE 54793004 54793004 54793004 54793004 54793004 54793004 5 1 PRIMING SUPPLY RESTRICTION 545100051 545100051 545100051 545100051 545100051 545100051 6 1 1/4" PRESSURE RELIEF VALVE, 5 PSI 93431019 93431019 93431019 93431019 93431019 93431019 7 1/" BALL VALVE 460501004 460501004 460501004 460501004 460501004 460501004 1 1/" GLOBE VALVE 460471005 460471005 460471005 460471005 460471005 460471005 9 1 1/" SPRING LOADED CHECK VALVE 931003 931003 931003 931003 931003 931003 10 1 1/" SWING CHECK VALVE 460491007 460491007 460491007 460491007 460491007 460491007 11 1 1/" Y-STRAINER 53531006 53531006 53531006 53531006 53531006 53531006 1 1 3/4" ANGLE VALVE 46041010 46041010 46041010 46041010 46041010 46041010 13 1 ANGLE VALVE 46041010 46041010 46041011 4604101 4604101 4604101 14 1 DRIP FUNNEL BRACKET CONNECTOR 9111005 9111005 9111005 9111005 9111005 9111005 15 1 DRIP FUNNEL BRACKET 9111003 9111003 9111003 9111003 9111003 9111003 16 1 DRIP FUNNEL 93431007 93431007 93431007 93431007 93431007 93431007 17 1 COMP. FITTING 90 1/" MNPT x 1/" OD TUBE 100153-01 100153-01 100153-01 100153-01 100153-01 100153-01 1 1 COMP. FITTING 90 1/" FNPT x 1/" OD TUBE 100140-01 100140-01 100140-01 100140-01 100140-01 100140-01 19 FLARE FITTING 90 1/" NPT x 1/" TUBE 54510006 54510006 54510006 54510006 54510006 54510006 0 FLARE FITTING 3/4" NPT x 3/4" TUBE 545100063 545100063 545100063 545100063 545100063 545100063 1 PIPE PLUG 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 1 PIPE PLUG 1/" 1/" 1/" 1/" 1/" 1/" 3 1 PIPE PLUG 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" FIGURE 10 (1 OF ) DV-5a VALVES SINGLE INTERLOCK PREACTION WET PILOT ACTUATION TRIM EXPLODED VIEW

TFP145 Page 15 of 34 ITEM QTY. DESCRIPTION CH 1-1/ IN. (DN40) IN. (DN50) 3 IN. (DN0) 4 IN. (DN100) 6 IN. (DN150) IN. (DN00) 4 UNION 1/" 1/" 1/" 1/" 1/" 1/" 5 1 STREET ELBOW 1/4" x 90 1/4" x 90 1/4" x 90 1/4" x 90 1/4" x 90 1/4" x 90 6 1 ELBOW 1/" x 45 1/" x 45 1/" x 45 1/" x 45 1/" x 45 1/" x 45 7 4 ELBOW 1/" x 90 1/" x 90 1/" x 90 1/" x 90 1/" x 90 1/" x 90 1 CROSS 1/" 1/" 1/" 1/" 1/" 1/" 9 TEE 1/" 1/" 1/" 1/" 1/" 1/" 30 1 REDUCING TEE 1/" x 1/4" x 1/" 1/" x 1/4" x 1/" 1/" x 1/4" x 1/" 1/" x 1/4" x 1/" 1/" x 1/4" x 1/" 1/" x 1/4" x 1/" 31 REDUCING TEE 1/" x 1/" x 1/4" 1/" x 1/" x 1/4" 1/" x 1/" x 1/4" 1/" x 1/" x 1/4" 1/" x 1/" x 1/4" 1/" x 1/" x 1/4" 3 REDUCING TEE 3/4" x 1/" x 3/4" 3/4" x 1/" x 3/4" 3/4" x 1/" x 3/4" 3/4" x 1/" x 3/4" 3/4" x 1/" x 3/4" 3/4" x 1/" x 3/4" 33 1 REDUCING TEE 3/4" x 3/4" x 3/4" 3/4" x 3/4" x 3/4" 1-1/4" x 1-1/4" x 3/4" " x " x 3/4" " x " x 3/4" " x " x 3/4" 34 1 PIPE NIPPLE 1/4" x CLOSE 1/4" x CLOSE 1/4" x CLOSE 1/4" x CLOSE 1/4" x CLOSE 1/4" x CLOSE 35 1 PIPE NIPPLE 1/4" x 1-1/" 1/4" x 1-1/" 1/4" x 1-1/" 1/4" x 1-1/" 1/4" x 1-1/" 1/4" x 1-1/" 36 4 PIPE NIPPLE 1/" x CLOSE 1/" x CLOSE 1/" x CLOSE 1/" x CLOSE 1/" x CLOSE 1/" x CLOSE 37 4 PIPE NIPPLE 1/" x 1-1/" 1/" x 1-1/" 1/" x 1-1/" 1/" x 1-1/" 1/" x 1-1/" 1/" x 1-1/" 3 1 PIPE NIPPLE 1/" x " 1/" x " 1/" x " 1/" x " 1/" x " 1/" x " 39 PIPE NIPPLE 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 40 1 PIPE NIPPLE 1/" x 4-1/" 1/" x 4-1/" 1/" x 4-1/" 1/" x 4-1/" 1/" x 4-1/" 1/" x 4-1/" 41 1 PIPE NIPPLE 1/" x 5" 1/" x 5" 1/" x 5" 1/" x 5" 1/" x 5" 1/" x 5" 4 1 PIPE NIPPLE 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 43 1 PIPE NIPPLE 3/4" x 1-1/" 3/4" x 1-1/" 3/4" x 1-1/" 3/4" x 1-1/" 3/4" x 1-1/" 3/4" x 1-1/" 44 1 PIPE NIPPLE 3/4" x 4-1/" 3/4" x 4-1/" 3/4" x 4-1/" 3/4" x 4-1/" 3/4" x 4-1/" 3/4" x 4-1/" 45 1 TUBING, MRA-1 545100065 545100065 545100066 53500140 53500160 5350010 46 1 TUBING, MC- 5350000 5350000 53500030 53500040 53500060 5350000 47 1 TUBING ASSY, ALARM TEST INTERCONNECT 53500030 53500030 535000330 535000340 535000360 53500030 4 1 TUBING ASSY, SYSTEM 53500040 53500040 535000430 535000440 535000460 53500040 49 1 PIPE NIPPLE 1/" x 3-1/" 1/" x 3-1/" 1/" x 4-1/" 1/" x 5-1/" 1/" x 5-1/" 1/" x 6-3/4" 50 1 PIPE NIPPLE 1/" x 5" 1/" x 5" 1/" x 5-1/" 1/" x 5-1/" 1/" x 5-1/" 1/" x 6-1/" 51 1 PIPE NIPPLE 1/" x 5" 1/" x 5" 1/" x 4-1/" 1/" x 5" 1/" x 7-1/" 1/" x 9-1/" 5 1 PIPE NIPPLE 3/4" x 5" 3/4" x 5" 3/4" x 6" 3/4" x 7" 3/4" x 9" 3/4" x 11-1/" 53 1 PIPE NIPPLE 3/4" x 4-1/" 3/4" x 4-1/" 1-1/4" x 3-1/4" " x 3" " x 3" " x 3" 54 1 PIPE NIPPLE 3/4" x 6-1/" 3/4" x 6-1/" 1-1/4" x 5-1/" " x 5" " x 6" " x " 55 56 1 WATER PRESSURE GAUGE, 300 PSI / 000 kpa (AMER/APAC) WATER PRESSURE GAUGE, 0 bar / 000 kpa (EMEA) AIR PRESSURE GAUGE, 0 PSI / 550 kpa RETARDED TO 50PSI / 1750 kpa 93431005 93431005 93431005 93431005 93431005 93431005 05500013 05500013 05500013 05500013 05500013 05500013 9343101 9343101 9343101 9343101 9343101 9343101 57 1 LABEL 545003004 545003004 545003004 545003004 545003004 545003004 5 1 LABEL WIRE A1 1 DV-5A VALVE SEE TABLE F FOR DV-5A VALVE PART NUMBERS A A3 A4 WATERFLOW PRESSURE ALARM SWITCH, PS10- (AMER/APAC) WATERFLOW PRESSURE ALARM SWITCH, PS10-1 (EMEA) 5710 5710 5710 5710 5710 5710 060 060 060 060 060 060 1 BUTTERFLY VALVE, G x G 5104A 5101A 1 BFV-300 BUTTERFLY VALVE, G x G 59300G030WS 59300G040WS 59300G060WS 59300G00WS FIGURE 577 RIGID GROOVED COUPLING 57715ACP 5770ACP 1 FIGURE 577 RIGID GROOVED COUPLING 57730ACP 57740ACP 57760ACP 5770ACP A5 1 GROOVE x THREADED OUTLET WELDED TEE 545004000 545004001 A6 1 FLARE FITTING 90 54510006 54510006 545100054 54510006 54510006 54510006 A7 1 FLARE FITTING 90 1/" NPT x 1/" TUBE 54510006 54510006 54510006 54510006 54510006 54510006 A 1 TUBING ASSY, DIAPHRAGM CHAMBER SUPPLY 540000015 54000000 540000030 540000040 540000060 54000000 NOTE: CH - Common Hardware - See Materials of Construction section for specifications. FIGURE 10 ( OF ) DV-5a VALVES SINGLE INTERLOCK PREACTION WET PILOT ACTUATION TRIM EXPLODED VIEW

TFP145 Page 16 of 34 A C6 C 34 56 47 P3 5 34 P 51 1 53 40 59 33 37 7 9 1 3 39 9 1 A5 A6 A7 P7 A5 A4 C1 C7 4 45 A P5 P6 P1 P4 A1 41 30 5 35 A 11 C A9 1-1/" (DN40) AND " (DN50) VALVES ONLY 15 57 9 39 9 39 6 6 13 39 9 3 54 9 55 5 46 44 14 4 19 31 16 C9 60 1 3 4 6 1 41 17 43 59 39 5 6 61 3 0 C7 A3 31 3 50 C3 3 36 31 3 31 3 4 49 0 3 C4 7 10 3 3 3 3 3 3 C5 Notes: 1. Port Connections P1 through P7 are described in Figure.. External Trim Connections C1 through C5 are described in Figure 17. 3. When ordering preassembled "DV-5A Valve with Galvanized Valve Trim" or pre-assembled "DV-5A Valve with Galvanized Valve Trim and Butterfly Valve", Items A1 through A9 are provided, as applicably related to valve size. 4. When ordering DV-5A Trim separately from the DV-5A Valve, Items A1 through A9 are separately ordered, as applicably related to valve size. Water Pressure Gauges for EMEA valve trim are also separately ordered. 60 1 36 3 1 10 33 ITEM QTY. DESCRIPTION CH 1-1/ IN. (DN40) IN. (DN50) 3 IN. (DN0) 4 IN. (DN100) 6 IN. (DN150) IN. (DN00) 1 3 1/4" GAUGE TEST VALVE 460051003 460051003 460051003 460051003 460051003 460051003 1 MRA-1 MANUAL RESET ACTUATOR 545001000 545001000 545001000 545001000 545001000 545001000 3 1 MC- MANUAL CONTROL STATION 54500000 54500000 54500000 54500000 54500000 54500000 4 1 AD-3 AUTOMATIC VALVE 54793004 54793004 54793004 54793004 54793004 54793004 5 1 DP-1 DRY PILOT ACTUATOR 501001 501001 501001 501001 501001 501001 6 1 PRIMING SUPPLY RESTRICTION 545100051 545100051 545100051 545100051 545100051 545100051 7 1 1/4" PRESSURE RELIEF VALVE 9343100 9343100 9343100 9343100 9343100 9343100 1 1/4" PRESSURE RELIEF VALVE, 5 PSI 93431019 93431019 93431019 93431019 93431019 93431019 9 1/" BALL VALVE 460501004 460501004 460501004 460501004 460501004 460501004 10 1/" GLOBE VALVE 460471005 460471005 460471005 460471005 460471005 460471005 11 1 1/" SPRING LOADED CHECK VALVE 931003 931003 931003 931003 931003 931003 1 1 1/" SWING CHECK VALVE 460491007 460491007 460491007 460491007 460491007 460491007 13 1 1/" Y-STRAINER 53531006 53531006 53531006 53531006 53531006 53531006 14 1 3/4" ANGLE VALVE 46041010 46041010 46041010 46041010 46041010 46041010 15 1 ANGLE VALVE 46041010 46041010 46041011 4604101 4604101 4604101 16 1 DRIP FUNNEL BRACKET CONNECTOR 9111005 9111005 9111005 9111005 9111005 9111005 17 1 DRIP FUNNEL BRACKET 9111003 9111003 9111003 9111003 9111003 9111003 1 1 DRIP FUNNEL 93431007 93431007 93431007 93431007 93431007 93431007 19 1 COMP. FITTING 90 1/" MNPT x 1/" OD TUBE 0 COMP. FITTING 90 1/" FNPT x 1/" OD TUBE 1 FLARE FITTING 90 1/" NPT x 1/" TUBE 54510006 54510006 54510006 54510006 54510006 54510006 FLARE FITTING 3/4" NPT x 3/4" TUBE 545100063 545100063 545100063 545100063 545100063 545100063 3 3 PIPE PLUG 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" 4 1 PIPE PLUG 1/" 1/" 1/" 1/" 1/" 1/" 5 1 PIPE PLUG 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" FIGURE 11 (1 OF ) DV-5a VALVES SINGLE INTERLOCK PREACTION DRY PILOT ACTUATION TRIM EXPLODED VIEW

TFP145 Page 17 of 34 ITEM QTY. DESCRIPTION CH 1-1/ IN. (DN40) IN. (DN50) 3 IN. (DN0) 4 IN. (DN100) 6 IN. (DN150) IN. (DN00) 6 UNION 1/" 1/" 1/" 1/" 1/" 1/" 7 1 STREET ELBOW 1/4" x 90 1/4" x 90 1/4" x 90 1/4" x 90 1/4" x 90 1/4" x 90 1 ELBOW 1/" x 45 1/" x 45 1/" x 45 1/" x 45 1/" x 45 1/" x 45 9 4 ELBOW 1/" x 90 1/" x 90 1/" x 90 1/" x 90 1/" x 90 1/" x 90 30 1 CROSS 1/" 1/" 1/" 1/" 1/" 1/" 31 4 TEE 1/" 1/" 1/" 1/" 1/" 1/" 3 3 REDUCING TEE 1/" x 1/4" x 1/" 1/" x 1/4" x 1/" 1/" x 1/4" x 1/" 1/" x 1/4" x 1/" 1/" x 1/4" x 1/" 1/" x 1/4" x 1/" 33 REDUCING TEE 1/" x 1/" x 1/4" 1/" x 1/" x 1/4" 1/" x 1/" x 1/4" 1/" x 1/" x 1/4" 1/" x 1/" x 1/4" 1/" x 1/" x 1/4" 34 REDUCING TEE 3/4" x 1/" x 3/4" 3/4" x 1/" x 3/4" 3/4" x 1/" x 3/4" 3/4" x 1/" x 3/4" 3/4" x 1/" x 3/4" 3/4" x 1/" x 3/4" 35 1 REDUCING TEE 3/4" x 3/4" x 3/4" 3/4" x 3/4" x 3/4" 1-1/4" x 1-1/4" x 3/4" " x " x 3/4" " x " x 3/4" " x " x 3/4" 36 PIPE NIPPLE 1/4" x CLOSE 1/4" x CLOSE 1/4" x CLOSE 1/4" x CLOSE 1/4" x CLOSE 1/4" x CLOSE 37 1 PIPE NIPPLE 1/4" x 1-1/" 1/4" x 1-1/" 1/4" x 1-1/" 1/4" x 1-1/" 1/4" x 1-1/" 1/4" x 1-1/" 3 9 PIPE NIPPLE 1/" x CLOSE 1/" x CLOSE 1/" x CLOSE 1/" x CLOSE 1/" x CLOSE 1/" x CLOSE 39 5 PIPE NIPPLE 1/" x 1-1/" 1/" x 1-1/" 1/" x 1-1/" 1/" x 1-1/" 1/" x 1-1/" 1/" x 1-1/" 40 1 PIPE NIPPLE 1/" x " 1/" x " 1/" x " 1/" x " 1/" x " 1/" x " 41 PIPE NIPPLE 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 4 1 PIPE NIPPLE 1/" x 3" 1/" x 3" 1/" x 3" 1/" x 3" 1/" x 3" 1/" x 3" 43 1 PIPE NIPPLE 1/" x 4-1/" 1/" x 4-1/" 1/" x 4-1/" 1/" x 4-1/" 1/" x 4-1/" 1/" x 4-1/" 44 1 PIPE NIPPLE 1/" x 5" 1/" x 5" 1/" x 5" 1/" x 5" 1/" x 5" 1/" x 5" 45 1 PIPE NIPPLE 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 1/" x -1/" 46 1 PIPE NIPPLE 3/4" x 1-1/" 3/4" x 1-1/" 3/4" x 1-1/" 3/4" x 1-1/" 3/4" x 1-1/" 3/4" x 1-1/" 47 1 PIPE NIPPLE 3/4" x 4-1/" 3/4" x 4-1/" 3/4" x 4-1/" 3/4" x 4-1/" 3/4" x 4-1/" 3/4" x 4-1/" 4 1 TUBING, MRA-1 545100065 545100065 545100066 53500140 53500160 5350010 49 1 TUBING, MC- 5350000 5350000 53500030 53500040 53500060 5350000 50 1 TUBING, DP-1 53500050 53500050 535000530 535000540 535000560 53500050 51 1 TUBING ASSY, ALARM TEST INTERCONNECT 53500030 53500030 535000330 535000340 535000360 53500030 5 1 TUBING ASSY, SYSTEM 53500040 53500040 535000430 535000440 535000460 53500040 53 1 PIPE NIPPLE 1/" x 3-1/" 1/" x 3-1/" 1/" x 4-1/" 1/" x 5-1/" 1/" x 5-1/" 1/" x 6-3/4" 54 1 PIPE NIPPLE 1/" x 5" 1/" x 5" 1/" x 5-1/" 1/" x 5-1/" 1/" x 5-1/" 1/" x 6-1/" 55 1 PIPE NIPPLE 1/" x 5" 1/" x 5" 1/" x 4-1/" 1/" x 5" 1/" x 7-1/" 1/" x 9-1/" 56 1 PIPE NIPPLE 3/4" x 5" 3/4" x 5" 3/4" x 6" 3/4" x 7" 3/4" x 9" 3/4" x 11-1/" 57 1 PIPE NIPPLE 3/4" x 4-1/" 3/4" x 4-1/" 1-1/4" x 3-1/4" " x 3" " x 3" " x 3" 5 1 PIPE NIPPLE 3/4" x 6-1/" 3/4" x 6-1/" 1-1/4" x 5-1/" " x 5" " x 6" " x " 59 WATER PRESSURE GAUGE, 300 PSI / 000 kpa (AMER/APAC) 93431005 93431005 93431005 93431005 93431005 93431005 WATER PRESSURE GAUGE, 0 bar / 000 kpa (EMEA) 05500013 05500013 05500013 05500013 05500013 05500013 60 AIR PRESSURE GAUGE, 0 PSI / 550 kpa RETARDED TO 50PSI / 1750 kpa 9343101 9343101 9343101 9343101 9343101 9343101 61 1 LABEL 545003004 545003004 545003004 545003004 545003004 545003004 6 1 LABEL WIRE A1 1 DV-5A VALVE SEE TABLE F FOR DV-5A VALVE PART NUMBERS A A3 A4 A5 1 1 WATERFLOW PRESSURE ALARM SWITCH, PS10- (AMER/APAC) WATERFLOW PRESSURE ALARM SWITCH, PS10-1 (EMEA) LOW AIR PRESSURE ALARM SWITCH, PS40- (AMER/APAC) LOW AIR PRESSURE ALARM SWITCH, PS40-1 (EMEA) 5710 5710 5710 5710 5710 5710 060 060 060 060 060 060 5730 5730 5730 5730 5730 5730 06 06 06 06 06 06 1 BUTTERFLY VALVE, G x G 5104A 5101A 1 BFV-300 BUTTERFLY VALVE, G x G 59300G030WS 59300G040WS 59300G060WS 59300G00WS FIGURE 577 RIGID GROOVED COUPLING 57715ACP 5770ACP 1 FIGURE 577 RIGID GROOVED COUPLING 57730ACP 57740ACP 57760ACP 5770ACP A6 1 GROOVE x THREADED OUTLET WELDED TEE 545004000 545004001 A7 1 FLARE FITTING 90 54510006 54510006 545100054 54510006 54510006 54510006 A 1 FLARE FITTING 90 1/" NPT x 1/" TUBE 54510006 54510006 54510006 54510006 54510006 54510006 A9 1 TUBING ASSY, DIAPHRAGM CHAMBER SUPPLY 540000015 54000000 540000030 540000040 540000060 54000000 NOTE: CH - Common Hardware - See Materials of Construction section for specifications. FIGURE 11 ( OF ) DV-5a VALVES SINGLE INTERLOCK PREACTION DRY PILOT ACTUATION TRIM EXPLODED VIEW

TFP145 Page 1 of 34 C5 39 A 7 36 A C4 C 3 53 44 P3 3 3 P 4 19 50 3 56 31 35 5 7 1 1 37 7 19 A4 A5 A7 P7 A4 A3 C1 4 A P5 P6 P1 P4 A1 55 33 C6 A9 1-1/" (DN40) AND " (DN50) VALVES ONLY 9 13 54 0 7 37 7 0 37 4 5 11 37 6 51 7 5 49 43 41 1 45 17 9 14 C7 4 A6 4 16 39 15 40 56 36 59 5 1 17 47 9 3 46 1 36 36 36 6 C3 57 1 34 30 10 31 Notes: 1. Port Connections P1 through P7 are described in Figure.. External Trim Connections C1 through C5 are described in Figure 1. 3. When ordering pre-assembled "DV-5A Valve with Galvanized Valve Trim" or pre-assembled "DV-5A Valve with Galvanized Valve Trim and Butterfly Valve", Items A1 through A9 are provided, as applicably related to valve size, and Item A7 is provided as P/N 5-7- 1-14 described in Technical Data Sheet TFP10. 4. When ordering DV-5A Trim separately from the DV-5A Valve, Items A1 through A9 are separately ordered, as applicably related to valve size. Water Pressure Gauges for EMEA valve trim are also separately ordered. ITEM QTY DESCRIPTION CH 1-1/ IN. (DN40) IN. (DN50) 3 IN. (DN0) 4 IN. (DN100) 6 IN. (DN150) IN. (DN00) 1 1/4 GAUGE TEST VALVE 460051003 460051003 460051003 460051003 460051003 460051003 1 MRA-1 MANUAL RESET ACTUATOR 545001000 545001000 545001000 545001000 545001000 545001000 3 1 MC- MANUAL CONTROL STATION 54500000 54500000 54500000 54500000 54500000 54500000 4 1 AD-3 AUTOMATIC VALVE 54793004 54793004 54793004 54793004 54793004 54793004 5 1 PRIMING SUPPLY RESTRICTION 545100051 545100051 545100051 545100051 545100051 545100051 6 1 1/4 PRESSURE RELIEF VALVE, 5 PSI 93431019 93431019 93431019 93431019 93431019 93431019 7 1/ BALL VALVE 460501004 460501004 460501004 460501004 460501004 460501004 1 1/ GLOBE VALVE 460471005 460471005 460471005 460471005 460471005 460471005 9 1 1/ SPRING LOADED CHECK VALVE 931003 931003 931003 931003 931003 931003 10 1 1/ SWING CHECK VALVE 460491007 460491007 460491007 460491007 460491007 460491007 11 1 1/ Y-STRAINER 53531006 53531006 53531006 53531006 53531006 53531006 1 1 3/4 ANGLE VALVE 46041010 46041010 46041010 46041010 46041010 46041010 13 1 ANGLE VALVE 46041010 46041010 46041011 4604101 4604101 4604101 14 1 DRIP FUNNEL BRACKET CONNECTOR 9111005 9111005 9111005 9111005 9111005 9111005 15 1 DRIP FUNNEL BRACKET 9111003 9111003 9111003 9111003 9111003 9111003 16 1 DRIP FUNNEL 93431007 93431007 93431007 93431007 93431007 93431007 17 COMP. FITTING 90 1/ MNPT x 1/ OD TUBE 1 1 COMP. FITTING 90 1/ FNPT x 1/ OD TUBE 19 FLARE FITTING 90 1/ NPT x 1/ TUBE 54510006 54510006 54510006 54510006 54510006 54510006 0 FLARE FITTING 3/4 NPT x 3/4 TUBE 545100063 545100063 545100063 545100063 545100063 545100063 1 PIPE PLUG 1/4 1/4 1/4 1/4 1/4 1/4 1 PIPE PLUG 1/ 1/ 1/ 1/ 1/ 1/ FIGURE 1 (1 OF ) DV-5a VALVES SINGLE INTERLOCK PREACTION ELECTRIC ACTUATION TRIM EXPLODED VIEW