INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Similar documents
Rotor No.3, No.4, No.5 No.1, No.2, No.3 Cup A, B No.3 Cup Extension Rod - 1 PC Batteries 4pcs, IEC R6 4pcs, IEC R6

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Operation Manual For NDJ-9S Digital Rotary Viscometer

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

SCALIX MULTIPURPOSE SCALES SCALIX COMPACT SCALE FKS-600 FKS-6000 INSTRUCTION MANUAL

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Marin Control Digital

Lumitester PD-30. Instruction Manual. Table of Contents

CAUTION-ELECTRICALLY OPERATED PRODUCT:

Digital/Analog Megohmmeter Model 1026 USER MANUAL

OPERATION MANUAL. BALTECH VP-3450 device for bearing diagnostics using shock pulse method

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Digital/Analog Megohmmeter Model 1026

System 3 ZB1PS Device Chassis. Operator s Manual

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

SPG-DIGI. Operating Instruction. Please read carefully before use!

GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.

Non-Contact Phase Rotation Tester

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

OPERATING INSTRUCTION

BATTERY CHARGER RS-1000 Instruction Manual

User's Manual. MV100 Rechargeable Battery Model. Yokogawa Electric Corporation. IM MV100-41E 1st Edition

2-Color Display High-Precision Digital Pressure Switch

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

TABLE OF CONTENTS 10.0 LIMITED WARRANTY

SERVO-TOP II ELECTRONIC ACTUATOR

BATTERY CHARGER Instruction Manual

ETHOS Digital Sound Level Meter. Operating Manual

High-speed detection even a little liquid leak

BM kv Digital Insulation Tester USER MANUAL

1.Safe testing IMPORTANT:

SSP-Series Portable Balances Operation Manual

OPERATING INSTRUCTION

User's Manual. Earth Ground Resistance Tester. Model Introduction

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

Triple Output Power Supply

EMF TESTER OPERATION MANUAL. ELECTROMAGNETIC FIELD RADIATION TESTER Model : EMF-832

Laser Receiver Model MCR3. Operator's Manual

BATTERY CHARGER Instruction Manual

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

HS SERIES ELECTRONIC HANGING SCALE CONTENTS OPERATION MANUAL 1. OPERATING PRECAUTIONS 2. KEYBOARD LAYOUT AND DESCRIPTION 3. INSTRUCTIONS FOR USE

Megohmmeter Test Probe

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

Direct Coupled Damper Actuator Model MY6050A1001

1/16 DIN Temperature Controller E5CS

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

Bolt. Inspiration strikes. Inspiration strikes. Compact Battery Pack. User s Manual COMPACT BATTERY PACK. User s Manual

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

WPS bar, 60 MPa, 8700 psi Hydraulic Pressure Transducer. User s Guide

DT304. Digital Temperature Logger INSTRUCTION MANUAL

Operation Manual for the Drummond Pipet-Aid XP

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)


NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

A B 0 0 C D E 6 7 G F F H 8 9 K M O O L N I J 1

CAUTION CONTENTS 5.0 WARRANTY

Virtual Measurements & Control. VC210 Operators Manual

OPERATING INSTRUCTION

2-Color Display High-Precision Digital Pressure Switch

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Portable pressure calibrator, Wally Box III Model CPH7600

EX Series. Electric Actuators for Ball and Butterfly Valves

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

DIGITAL RCD(ELCB) TESTER

OWNER S MANUAL. 16 Stand Fan Model: SF-16T07

Chapter. Installation and. In this Chapter...

Parker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, Bielefeld Phone Fax

Non-Contact Phase Rotation Tester

Wall-Mount Thermohygrometers

Centrifuge Operator / Service Manual

True RMS Autoranging Multimeter

Model UT602/603: OPERATING MANUAL

Solar Power Light Meter

HS5E Miniature Interlock Switches with Solenoid

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

Battery compartment door. Belt clip (back of pump) Front view Top view. Figure 1. AirLite Sample Pump

INSTRUCTION MANUAL CAT Bio-Pump Plus

ROTARY VISCOMETER VP 1000 RM

Positive displacement batch controller

Thermistor Thermometer MODEL NO

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

ADN-W CASE. Transport & Charging Case. Instruction manual

CDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Operation Manual for the Drummond Pipet-Aid XL

Specification Approval Sheet

Transcription:

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.4.17

Organization of this manual This manual describes the features and operation principles of the Viscotester VT-05 (for low viscosity measurement) and VT-06 (for high viscosity measurement). The following pages contain important information on safety. Be sure to read this part. This manual contains the following sections. Outline Gives basic information on the features of the unit. Controls and functions Briefly identifies and explains all controls and other parts of the unit. Preparations Explains how to make power connections and how to mount the rotor and cup. i

Measurement Describes how to perform the measurement. Applied part Describes rotor extension for VT-06. Specifi cations Lists the technical specifications of the unit * All company names and product names mentioned in this manual are trademarks or registered trademarks of their respective owners. ii

FOR SAFETY In this manual, important safety instructions are specially marked as shown below. To prevent the risk of injury to persons and severe damage to the unit or peripheral equipment, make sure that all instructions are fully understood and observed. Caution Important Disregarding instructions printed here incurs the risk of injury to persons and/or damage to peripheral equipment. Disregarding instructions printed here incurs the risk of damage to the unit. Note Mentioned about the tips to use this unit properly. (This messages do not have to do with safety.) iii

Precautions VT-05 The unit is designed for making measurements using cup A containing about 460 ml of sample fluid. If another container is used, the viscosity resistance working on the rotor will be different, leading to deviations in the measurement result. The viscosity scale readings for the various rotor types overlap in part. For example, the following viscosity ranges can be measured with the following both rotors: 15 to 33 mpa s: No. 4 or No. 5 rotor 50 to 150 mpa s: No. 5 or No. 3 rotor However, depending on the properties of the sample fluid and on mechanical calibration results, the obtained measurement values may be different when changing rotors. To facilitate the correct evaluation of data, you should therefore note the rotor number along with the measurement results. iv

VT-06 The No. 1 rotor and No. 2 rotor are designed for making measurements using a JIS 300 ml beaker containing about 350 ml of sample fluid. If another container is used, the viscosity resistance working on the rotor will be different, leading to deviations in the measurement result. If a different container has to be used, make sure that it is considerably larger than the JIS 300 ml beaker. In this case, the obtained measurement values will be low. The No. 3 rotor must be combined with the No. 3 cup, otherwise large errors will occur in the reading. *The actual capacity of the JIS 300 ml beaker is about 420 ml. v

The viscosity scale readings for the various rotor types overlap in part. For example, the following viscosity ranges can be measured with the following both rotors: 3 to 13 dpa s: No. 3 or No. 1 rotor 100 to 150 dpa s: No. 2 or No. 1 rotor However, depending on the properties of the sample fluid and on mechanical calibration results, the obtained measurement values may be different when changing rotors. To facilitate the correct evaluation of data, you should therefore note the rotor number along with the measurement results. vi

Common precautions Keep the time for one measurement under 100 seconds. Ambient conditions for operation of the unit are as follows: temperature range 5 C to 35 C, relative humidity 10% to 90%RH. Because the drive section is not hermetically sealed, do not use the unit in environments with volatile gas or dust pollution. Otherwise the drive section may be damaged. When attaching or removing a rotor, put the viscotester in a horizontal position and carefully move the rotor in the vertical direction. To prevent the possibility of damage, take care not to exert strong force on the rotor mounting shaft in the vertical or horizontal direction. The rotor mounting shaft is screwed into the body of the unit. Take care not to inadvertently dislodge it when attaching or removing a rotor. vii

The rubber section of the rotor mounting shaft may drop out at the time of measurement. When you want to avoid the foreign material to a sample, remove the rubber section at the time of measurement. Remove the batteries from the unit when it is not being used, to prevent the possibility of damage by leaking battery fluid. Protect the unit from water, dust, extreme temperatures, humidity, and direct sunlight during storage. Also keep the unit away from air with high salt or sulphur content, gases, and stored chemicals during storage and use. Do not try to disassemble or alter the unit. Dispose of the unit and of batteries only according to national and local regulations at the place of use. Do not tap the LCD panel of the unit with a pointed object such as a pencil, screwdriver, etc. viii

Clean the unit only by wiping it with a soft, dry cloth or, when necessary, with a cloth lightly moistened with water. Do not use any solvents, cleaning alcohol or chemical cleaning agents. The optional stand (VA-04) is useful to stabilize the viscotester during long-term or continuous measurements. To ensure continued accuracy, have the unit checked and serviced at regular intervals. Contact the supplier. In case of malfunction, do not attempt any repairs. Note the condition of the unit clearly and contact the supplier. ix

Change in viscosity unit According to Japanese and international standard agreements, the viscosity unit is displayed in the Pascal-second (Pa s). The relation between the Pa s and Poise (P) is as follows. VT-05: VT-06: 1 mp s = 1 cp mpa s: Millipascal-seconds cp: Centipoise 1 dp s = 1 P dpa s: Decipascal-seconds P: Poise x

Contents FOR SAFETY... iii Change in viscosity unit...x Outline...1 Controls and functions...2 Configuration (VT-05)...2 Configuration (VT-06)...3 Top view...4 Rear view...5 Bottom view...6 Display...7 Operation key panel...8 xi

Preparations...10 Power Supply...10 Attaching the Rotor and Cup (VT-05)...15 Attaching the Rotor (VT-06)...17 Preparing the Sample Fluid...18 Measurement...20 Applied part...24 Rotor extension (only for VT-06)...24 Specifications...25 xii

Outline The Viscotester VT-05/VT-06 is a compact, uni-cylinder rotational viscometer designed for easy use in the field. When a rotor put into the sample liquid is rotated by fixed speed, a viscous resistance is caused. Viscosity can be measured by detecting the viscous resistance (torque). Three different types of rotors are supplied, covering a wide range of applications. 1

Controls and functions Configuration (VT-05) Main unit No. 3 rotor No. 4 rotor No. 5 rotor AC adapter (option) IEC LR6 (size AA) batteries Cup A (no cutout) Cup B (with cutout) 2

Controls and functions Configuration (VT-06) Main unit No. 3 rotor No. 1 rotor No. 2 rotor IEC LR6 (size AA) batteries No. 3 cup AC adapter (option) Rotor extension 3

Controls and functions Top view Operation key panel (see page 8) Display (see page 7) Bottom cover Stand mounting screw 4

Controls and functions Rear view Cup mounting pin Rotor mounting shaft (with rubber cover) Battery compartment Note In order to protect the internal gears, the rotor mounting shaft is designed to be detachable. Like the rotor, the screw thread is left-handed, which may lead to loosening when removing the rotor. If this happens, lightly tighten the shaft again. 5

Controls and functions Bottom view DC IN jack MODE selector switch A: Normal operation B: The motor starts to turn at the same time the power key is set to ON. 6

Controls and functions Display VT-05 example VT-06 example 7

Controls and functions Operation key panel Rotor selector key Level gauge Power key Back light ON/OFF key START key (Measurement start/stop) 8

Controls and functions Power key Turns power to the unit on and off. The key must be held for at least 1 second to take effect. START key Press to start or stop the measurement. Back light ON/OFF key Turns the backlight on and off. The backlight is automatically turned off when there is no key activity for a certain period. Rotor selector key Press to select the rotor number. 9

Preparations Power Supply Using an AC Adapter (Option) To power the unit from an AC adapter, plug the output cable from the adapter into the DC IN jack on the viscotester and plug the AC adapter into an AC outlet rated for 100 V to 240 V AC. Caution To prevent the risk of electric shock, always connect the adapter output cable to the viscotester fi rst, and only then plug the AC adapter into the AC outlet. Use a genuine AC adapter (VA-05J) 10

Preparations DC IN jack AC adapter VA-05J Open the bottom cover To AC outlet, 100 V to 240 V AC, 50/60 Hz 11

Preparations Using Batteries When operating the unit on battery power, be sure to set the selector switch inside the battery compartment to the correct position for the type of batteries in use (alkaline batteries or nickel-metal hydride rechargeable batteries) Alkaline battery (ALKALINE)- Nickel-metal hydride rechargeable battery (NI-MH) selector switch 12

Preparations Checking the battery voltage During viscosity measurement, check the battery status on the display. The number of black segments will decrease as the batteries get used up (4 steps). When battery status indicator is down to 1 segment: Replace the batteries as early as possible with a fresh set. When battery status indicator shows no black segments: Measurement cannot be performed. Replace the batteries with a fresh set. 13

Preparations Inserting the batteries 1. Remove the battery compartment lid as shown below. 2. Insert four IEC LR6, size AA batteries, paying attention to the polarity as shown below. 3. Replace the cover. Battery compartment Push Push the latch in the arrow direction and then lift up to open the lid Caution Do not insert the battery conversely. 14

Preparations Attaching the Rotor and Cup (VT-05) Select a suitable rotor for the viscosity of the sample fluid (see page 25), and insert the rotor into the cup. Taking care that the rotor does not fall out, raise the cup, engage the oval hole in the handle on the cup mounting pin of the main unit, and rotate it to the right to lock. Turn the cup again to the right to verify that it is securely fastened. After that, screw the rotor into the rotor mounting shaft. 15

Preparations Note If you do not know the viscosity of the sample fluid, perform measurement using rotors in the following order: No. 3 rotor, No. 5 rotor, No. 4 rotor. Because this is a left-hand (reverse) screw thread, you must turn the rotor counterclockwise to screw it in. Check the blue rubber section of the rotor mounting shaft does not touch the case of the unit. Otherwise the correct measurement may be impossible. To detach the rotor, hold the blue rubber section of the rotor mounting shaft with your fingers and turn the rotor clockwise. To remove, detach the rotor first and then remove the cup. 16

Preparations Attaching the Rotor (VT-06) Select a suitable rotor for the viscosity of the sample fluid (see page 29), and screw the rotor into the rotor mounting shaft. Note If you do not know the viscosity of the sample fluid, perform measurement using rotors in the following order: No. 2 rotor, No. 1 rotor, No. 3 rotor. Because this is a left-hand (reverse) screw thread, you must turn the rotor counterclockwise to screw it in. Check the blue rubber section of the rotor mounting shaft does not touch the case of the unit. Otherwise the correct measurement may be impossible. To detach the rotor, hold the blue rubber section of the rotor mounting shaft with your fingers and turn the rotor clockwise. 17

Preparations Preparing the Sample Fluid VT-05 When using cup A (no cutout), fill the cup with sample fluid to the upper brim. When using cup B (with cutout), insert the cup into the sample fluid up to the upper brim. For both cups A and B, the indication of the sample amount is about 460 ml. VT-06 Choose the rotor according to the viscosity of the sample fluid. Depending on the rotor, the required cup size also changes. For No. 1 and No. 2 rotors, use a JIS 300 ml beaker* filled with about 350 ml of sample fluid. For the No. 3 rotor, use the No. 3 cup filled with about 150 ml of sample fluid. *The actual capacity of the JIS 300 ml beaker is about 420 ml. 18

Preparations Note Adjust the volume of the sample fluid so that it does not overflow when the rotor is inserted in the cup or beaker. When measuring fluid with a low viscosity, the fluid may spill when the rotor is activated. Adjust the fluid first to a suitable level. A JIS 300 ml beaker is not supplied. Please use a commercially available product. 19

Measurement 1. Hold the viscotester in one hand or mount it to the optional stand (VA-04). Use the level gauge on the unit to verify that the unit is approximately horizontal. Fluid mark 2. Place the rotor in the center of the cup or beaker and fill in sample fluid so that it comes to about the center of the fluid mark on the rotor. 3. Hold down the power key until the power is set to on (at least 1 second). 4. Use the rotor selector key to select the correct rotor number. 20

Measurement 5. Press the START key. The indication RUN appears on the display and the rotor starts to turn. Hold the unit steady until the viscosity indication has stabilized. When a stable value has been obtained, press the START key again. The rotor stops turning, and the measurement value remains on the display for easy reading. 6. When measurement is completed, hold down the power key until the power is set to off (at least 1 second). * About power swing When the rotor starts to turn, temporary overload may cause a socalled power swing condition where the rotor cannot turn properly. In such a case, the indication FAIL is shown on the display, the rotor is stopped, and then started up again. 21

Measurement Important If the measurement value is below the measurement range for the respective rotor, the indication UNDER will be shown in the left part of the display under the bar graph. If the measurement value exceeds the measurement range, the indication OVER will be shown. Select the correct rotor so that these indications do not appear. 22

Measurement Note Battery life will differ depending on the sample fluid being measured, but a rough estimate is shown below. Conditions: - IEC LR6 (size AA) alkaline batteries - Measurement time 100 seconds per measurement - Sample fluid viscosity near maximum of respective rotor measurement range Battery life: VT-05 approx. 600 measurements VT-06 approx. 300 measurements The unit cannot be shut the power off by the power key while the rotor is turning. 23

24 Applied part Rotor extension (only for VT-06) The supplied foldable rotor extension consists of three 30 cm rods joined by rings. The combined length is 90 cm. When wishing to use the extension at a length of 30 cm or 60 cm, open the connector rings with a pair of pliers, remove the desired number of elements, and rejoin the extension rods. Be sure to close the rings fully again, to prevent the extension from getting detached during use. Attach the end with the male thread to the viscotester and the end with the female thread to the rotor. Note that both are left-hand (reverse) screw threads, so you must turn the parts counterclockwise to screw them in. When measuring a fluid with high viscosity, the joint will look as shown in the illustration, but this does not affect the measurement. The rotor extension rods are made of stainless steel.

Specifications VT-05 Measurement range No. 4 rotor: 2 to 33 mpa s (resolution: 0.1) No. 5 rotor: 15 to 150 mpa s (resolution: 1) No. 3 rotor: 50 to 300 mpa s (resolution: 1) Sample fluid capacity Approx. 460 ml (With supplied accessories cup A or cup B) Measurement accuracy Within ±5% of each rotor s maximum measurement range * Calibrated according to JIS Z 8809:2011 standard liquids for calibrating viscometer Rotor speed 62.5 rpm 25

Specifications Max. continuous measurement time per measurement 100 s Display value hold function Value at end of measurement is retained Backlight function Switchable backlight Time until auto-off: 60 s (when rotor is not operating and unit is powered from batteries) Auto shutdown function (when an AC adapter is not used) If rotor is not turning and no controls are operated for 5 minutes, power is automatically shut off Resume function Last selected rotor number setting is retained during power-off Ambient conditions for use 5 C to 35 C, 10% to 90%RH (no condensation) 26

Specifications Power requirements Alkaline batteries LR6, Ni-MH rechargeable batteries, or AC adapter VA-05J (5 V to 7 V : rated voltage 6 V) Current consumption approx. 150 ma (at maximum torque) Battery voltage check Displaying battery status (4 steps) Dimensions 175 (H) 77 (W) 45 (D) mm (maximum) 175 (H) 77 (W) 40 (D) mm (without protruding parts) Weight Approx. 260 g (without batteries) 27

Specifications Supplied accessories No. 3 rotor (dia. 45 47 160 mm) SUS304 1 No. 4 rotor (dia. 78 46 159 mm) A1050 (alumite) 1 No. 5 rotor (dia. 61.2 36 149 mm) A1050 (alumite) 1 Cup A (no cutout) (dia. 92 76 mm) A1050 (alumite) 1 Cup B (with cutout) (dia. 92 76 mm) A1050 (alumite) 1 IEC LR6 (size AA) battery 4 Instruction manual 1 Viscosity measurement guide 1 Inspection certificate 1 Optional accessory AC adapter Stand VA-05J VA-04 28

Specifications VT-06 Measurement range (based on combination with the cup specified below Sample fluid capacity ) No. 3 rotor: 0.3 to 13 dpa s (resolution: 0.1) No. 1 rotor: 3 to 150 dpa s (resolution: 1) No. 2 rotor: 100 to 4000 dpa s (resolution: 10) Sample fluid capacity No. 1 and No. 2 rotor Approx. 350 ml (with JIS 300 ml beaker) No. 3 rotor Approx. 150 ml (with No. 3 cup) Clearance between rotor end and cup bottom: about 15 mm Measurement accuracy and reproducibility Measurement accuracy ±10% ±1 digit of indicated value 29

Specifications Reproducibility ±5% * Calibrated according to JIS Z 8809:2011 standard liquids for calibrating viscometer * The rounding error resulting from resolution occurs Rotor speed 62.5 rpm Max. continuous measurement time per measurement 100 s Display value hold function Value at end of measurement is retained Backlight function Switchable backlight Time until auto-off: 60 s (when rotor is not operating and unit is powered from batteries) 30

Specifications Auto shutdown function (when an AC adapter is not used) If rotor is not turning and no controls are operated for 5 minutes, power is automatically shut off Resume function Last selected rotor number setting is retained during power-off Ambient conditions for use 5 C to 35 C, 10% to 90%RH (no condensation) Power requirements Alkaline batteries LR6, Ni-MH rechargeable batteries, or AC adapter VA-05J (5 V to 7 V : rated voltage 6 V) Current consumption approx. 250 ma (at maximum torque) Battery voltage check Displaying battery status (4 steps) Dimensions 175 (H) 77 (W) 45 (D) mm (maximum) 175 (H) 77 (W) 40 (D) mm (without protruding parts) Weight Approx. 260 g (without batteries) 31

Specifications Supplied accessories No. 1 rotor (dia. 24 53 166 mm) SUS304 1 No. 2 rotor (dia. 15 1 113 mm) SUS304 1 No. 3 rotor (dia. 45 47 160 mm) SUS304 1 No. 3 Cup (dia. 52.6 75 mm) SUS304 1 Rotor extension (in a tube) (900 mm; 300 mm 3) SUS304 1 IEC LR6 (size AA) battery 4 Instruction manual 1 Viscosity measurement guide 1 Inspection certificate 1 Optional accessory AC adapter Stand VA-05J VA-04 32

Specifications 77 5 40 175 Dimensional Drawings Unit: mm 33