ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

Similar documents
Versatile and Powerful

Versatile and Powerful

Minimum 27 in-lb torque

Minimum 27 in-lb Torque

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

NMB (X) 24-MFT. Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

LMCB24-SR LMCB24-SR-T. applications. Dimensions (All numbers in brackets are in millimeters.) 1/4 to 3/4 [6 to 20] 5/16 to 3/4 [8 to 26] 1.

LMX120-SR. Proportional Control, Non-Spring Return, Direct Coupled,100 to 240 VAC, for 2 to 10 VDC and 4 to 20 ma

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

LMB24-3 (-S)(-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

GMX On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 100 to 240 VAC

LF Series At A Glance

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

LMX24-3 (-T) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

Minimum 18 in-lb Torque. Applications. TF Series At A Glance. TF Series Spring Return Direct Coupled Actuator. For damper areas up to 4.

Minimum 18 in-lb Torque

AMB24-3(-S) On/Off-Floating Point Control, Non-Spring Return, Direct Coupled, 24 V

LF Series Spring Return Direct Coupled Actuator

G6 C(S)(LCS) 2-way Pressure Compensated Flanged Globe Valve

AF Series Spring Return Direct Coupled Actuator

ZG106 or ZG 107 bracket

AFXUP-S (p. 19) AFB24-MFT. AFXUP (p. 19) AFBUP-S

FSAF24(-S) US, FSAF120(-S) US

Mounting Installation Instructions LM, NM, AM, GM

AM Series Direct Coupled Actuator

G3 (D) 3-way Globe Valve, Bronze Trim

AF Series Spring Return Direct Coupled Actuator

Torque min. 35 in-lb, for control of air dampers

Product Cross Reference

G7 (S) 3-way Mixing Flanged Globe Valve, Bronze or Stainless Steel Trim

Belimo is the Worldwide Leader in Fire and Smoke Actuation

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

LF24-SR US TF24-SR US TFX24 US LF24 US. B3 B Three-way Characterized Control Valve, Chrome Plated Brass Ball and Brass Stem

BELIMO CONTROLS

LF Series Spring Return Direct Coupled Actuator

GM Series Direct Coupled Actuator

B2/B3 Series Characterized Control Valve, Non-Spring Return Actuator

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default) 3/4" Centered (Field Selectable)

G780, 3-Way, Mixing Flanged Globe Valve

Technical Documentation Ball Valves

B2 Series Characterized Control Valve, Non-Spring Return Actuator

Mounting Installation Instructions NKQ, GK

G7100S, 3-Way, Mixing Flanged Globe Valve

B278, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

F6200L, 8, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

AF24-MFT95 US Proportional Damper Actuator, Spring Return Fail-Safe, 24 V for Use with Honeywell Electronic Series 90, or a 0 to 135Ω input

B352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem

Commercial Actuator Selection Chart Non-Spring Return

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Accessories. Technical Data Extension Height 2" Material. Stainless Steel. Bearing TR LRB (X) ARB (X) TF LF AF. Extension Bracket CCV-EXT-Kit

F6 Series 2-Way, Victaulic Butterfly Valve

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

Non-Spring Return EconoDrive Floating Actuator

F6300L, 12, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

M9208-xxx-x Series Electric Spring-Return Actuators

M9203-xxx-2(Z) Series Electric Spring-Return Actuators

G7150D, 3-Way, Diverting Flanged Globe Valve

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Technical data. Safety notes

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

M9208-xxx-x Series Electric Spring Return Actuators

M9208-xxx-x Series Electric Spring Return Actuators

Power consumption In operation At rest For wire sizing

G765, 3-Way, Mixing Flanged Globe Valve

G765, 3-Way, Mixing Flanged Globe Valve

See «Overview of types»

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

M9208-xxx-x Series Electric Spring Return Actuators

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

M9220 Series Electric Spring-Return Actuators

M9220-xxx-3 Electric Spring Return Actuators

F6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Installation Instructions

LF24-ECON-R03(-R10) US Operation, Installation and Wiring

M9203-xxx-2(Z) Series Electric Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

F6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Installation Instructions

G6125C, 2-Way, Pressure Compensated Flanged Globe Valve

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Pressure Independent Characterized Control Valves (PICCV)

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

M9216 Series Electric Spring Return Actuators

Technical Documentation Pressure Independent Characterized Control Valves (PICCV) Patented Effective December 2007

Power consumption In operation At rest For wire sizing

RUS-L24-MOD Electric 24 Volt Modulating Control Damper Actuator

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

Strobic Air, a Met-Pro Product Recovery/Pollution Control Technologies Business, is pleased to submit the attached proposal for your consideration.

VA9208-xxx-xx Series Electric Spring Return Actuators

Transcription:

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators The ZG-JSL jackshaft linkage is designed to easily attach to any part of a jackshaft and allow easy installation of select elimo actuators. The unique open ended design and clamp insert allows the ZG-JSL to be used with any jackshaft from ½ to ¾ in diameter. Removal of the insert will allow the linkage to attach to a maximum shaft diameter of 1.05. Changing the antirotation plate will allow various actuators to be mounted. Default/Configuration The ZG-JSL linkage can also be configured by moving the anti-rotation plate 90 for space saving applications. See mounting configurations below. The ZG-JSLA will have a factory mounted actuator on the linkage in the vertical position only. The ¾ diameter built-in steel shaft allows direct coupling to the elimo series actuators in the chart below. There is a torque reduction when using the ZG-JSL linkage. Verify application requirements before use. Actuator* AF Series Torque Reduction 123 in-lbs Technical Data Fits shaft diameter Materials: Housing earings Shafts Max torque output Max actuator yield Mech. angle of rotation Ambient temperature Storage temperature ZG-JSL, ZG-JSLA ½ to ¾ with insert, 1.05 without insert galvanized steel GF Delrin steel 90% of rated actuator torque see chart on right 90 mountable -22 F to 122 F [-33 C to 50 C] -40 F to 176 F [148.9 C to 80 C] 3.25 lbs [1.47 kg] AFX Series NFX Series LF Series NMX Series AMX Series * GM/GK series pending approval. 166 in-lbs 87 in-lbs 33 in-lbs 87 in-lbs 166 in-lbs D314 M40045-07/10 - Subject to change. elimo Aircontrols (USA), Inc. Mounting Configurations 8.74 [222] 14.05 [357] 10.16 [258] 4.13 [105] 1.93 [49] 3.86 [98] 4.41 [112] 4.76 [121] 4.65 [118] 6.42 [163] 10.31 [262] 1

AM(X)24-3(-S)(-T) On/Off, Floating Point, Non-Spring Return, 24 V Torque min. 180 in-lb for control of damper surfaces up to 45 sq ft. Technical Data AM(X)24-3(-S)(-T) Power supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption 2.5 W (0.5 W) Transformer sizing 5.5 VA (Class 2 power source) Electrical connection 3 ft, 18 GA plenum rated cable 3 ft, 18 GA appliance rated cable (-S) 1/2 conduit connector protected NEMA 2 (IP54) Overload protection electronic throughout 0 to 95 rotation Control on/off, floating point Input impedance 600 Ω Angle of rotation max. 95, adjust. with mechanical stop Torque 180 in-lb [20 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button Auxiliary switch (-S models) 1 x SPDT, 3A (0.5A) @ 250 VAC adj. 0 to 100%, UL approved Running time 95 seconds, constant independent of load Humidity 5 to 95% RH non condensing (EN 60730-1) Ambient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA 2, IP54, UL enclosure type 2 Housing material UL94-5VA Agency listings culus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC Noise level <45d(A) Servicing maintenance free Quality standard ISO 9001 2.2 lbs [1000 Kg] AM24-3 2.4 lbs [1050 Kg] AM24-3-S AM(X)24-3-T Electrical connection screw terminal (for 26 to 14 GA wire) unprotected (NEMA 1/IP20) Rated Impulse Voltage 800V, Type of action 1, (1. for -S version), Control Pollution Degree 3. For on/off and floating point control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp, self-centered default. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The AM... series provides 95 of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. The AM...24-3 actuators use a sensorless brushless DC motor, which is controlled by an Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. The AM...24-3-S version is provided with 1 built-in auxiliary switch. This SPDT switch is provided for safety interfacing or signaling, for example, for fan start-up. The switching function is adjustable 0 to 95. The auxiliary switch is double insulated so an electrical ground connection is not necessary. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. 1/2 to 1.05 [12.7 to 26.67] 2/5 to 1.05 [10 to 26.67] 2.2 [56] 3.46 [88] 1.18 [30] 4.06 [103] 5.47 [139] 4.3 [109] To center of mounting slot. 2 [50.8] 2.49 [63.4] D122 213

AM(X)24-3(-S)(-T) On/Off, Floating Point, Non-Spring Return, 24 V Accessories K-SA Reversible Clamp ZG-100 Universal Mounting racket ZG-101 Universal Mounting racket ZG-103 Universal Mounting racket ZG-104 Universal Mounting racket Z-SMA AM/SM to AM Retrofit Mounting racket ZG-NMA Crank arm Adaptor Kit AV8-25 Universal Shaft Extension ZG-JSA (-1, 2,3) Jackshaft Adaptors for Hollow Jackshafts ZS-T Terminal Cover for NEMA 2 ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing Tool-06 8 mm & 10 mm Wrench PS-100 Actuator Power Supply Simulator S1A, S2A Auxiliary Switch (es) P370 Shaft Mount Auxiliary Switch P A Feedback Potentiometers NOTE: When using AM...24-3 actuators, only use accessories listed on this page. Typical Specification Floating point, on/off control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05 diameter. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. If required, actuators shall be provided with one adjustable SPDT auxiliary switch. Actuators with auxiliary switches must be constructed to meet the requirements for double insulation so an electrical ground is not required to meet agency listings. If required, actuators will be provided with a screw terminal strip for electrical connections (AMX24-3-T). Run time shall be constant and independent of torque. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. Wiring Diagrams 1 Provide overload protection and disconnect as required. 3 Actuators may also be powered by 24 VDC. For end position indication, interlock control, fan startup, etc., AM24-3-S incorporates one built-in auxiliary switches: 1 x SPDT, 3A (0.5A) @250 VAC, UL Approved, adjustable 0 to 95. Meets culus or UL and CSA Standard requirements without the need of an electrical ground connection. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off control W259_08 Floating Point or On/Off control W260_08 W258_08 Auxiliary Switch 214

AMX120-3 On/Off, Floating Point, Non-Spring Return, 100 to 240 VAC Torque min. 180 in-lb for control of damper surfaces up to 45 sq ft. Technical Data AMX120-3 Power supply 100 to 240 VAC, 50/60 Hz (nominal) 85 to 265 VAC, 50/60 Hz (tolerance) Power consumption 3 W (0.6 W) Transformer sizing 7 VA (Class 2 power source) Electrical connection 18 GA appliance rated cable 1/2 conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload protection electronic throughout 0 to 95 rotation Control on/off, floating point Input impedance 600 Ω Angle of rotation max. 95, adjust. with mechanical stop Torque 180 in-lb [20 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button Running time 300 seconds 150 seconds 95 seconds constant independent of load Humidity 5 to 95% RH non condensing (EN 60730-1) Ambient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA 2/IP54 Housing material NEMA 2, IP54, UL enclosure type 2 Agency listings culus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC Noise level <45d(A) Servicing maintenance free Quality standard ISO 9001 2.2 lbs [1.0 Kg] Rated Impulse Voltage 4kV, Type of action 1, Control Pollution Degree 3 For on/off and floating point control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp, self-centered default. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The AMX series provides 95 of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. The AMX120-3 actuators use a sensorless brushless DC motor, which is controlled by an Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. 1/2 to 1.05 [12.7 to 26.67] 2/5 to 1.05 [10 to 26.67] 2.2 [56] 3.46 [88] 1.18 [30] 4.06 [103] 5.47 [139] 4.3 [109] To center of mounting slot. 2 [50.8] 2.49 [63.4] D122 217

AMX120-3 On/Off, Floating Point, Non-Spring Return, 100 to 240 VAC Accessories K-SA Reversible Clamp ZG-100 Universal Mounting racket ZG-101 Universal Mounting racket ZG-103 Universal Mounting racket ZG-104 Universal Mounting racket Z-SMA AM/SM to AM Retrofit Mounting racket ZG-NMA Crank arm Adaptor Kit AV8-25 Universal Shaft Extension ZG-JSA (-1, 2,3) Jackshaft Adaptors for Hollow Jackshafts ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing Tool-06 8 mm & 10 mm Wrench PS-100 Actuator Power Supply Simulator S1A, S2A Auxiliary Switch (es) P370 Shaft Mount Auxiliary Switch P A Feedback Potentiometers NOTE: When using AMX120-3 actuators, only use accessories listed on this page. Wiring Diagrams 1 Provide overload protection and disconnect as required. 2 CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Meets culus or UL and CSA Standard requirements without the need of an electrical ground connection. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Typical Specification Floating point, on/off control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05 diameter. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. On/Off control Floating Point or On/Off control 218

AM(X)24-SR(-T) Proportional, Non-Spring Return, 24 V, for 2 to 10 VDC or 4 to 20 ma Torque min. 180 in-lb for control of damper surfaces up to 45 sq ft. Technical Data AM(X)24-SR(-T) Power supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption 2.5 W (0.4 W) Transformer sizing 5 VA (Class 2 power source) Electrical connection 18 GA plenum rated cable 1/2 conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload protection electronic throughout 0 to 95 rotation Operating range Y 2 to 10 VDC, 4 to 20 ma Input impedance 100 kω (0.1 ma), 500 Ω Feedback output U 2 to 10 VDC (max 0.5 ma) Angle of rotation max. 95, adjust. with mechanical stop Torque 180 in-lb [20 Nm] Direction of rotation reversible with switch actuator will move: =CCW with decreasing control signal (10 to 2V) =CW with decreasing control signal (10 to 2V) Position indication reflective visual indicator (snap-on) Manual override external push button Running time 300 seconds 150 seconds 95 seconds constant independent of load Humidity 5 to 95% RH non condensing (EN 60730-1) Ambient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA 2, IP54, UL enclosure type 2 Housing material UL94-5VA Agency listings culus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC Noise level <45d(A) Servicing maintenance free Quality standard ISO 9001 2.2 lbs [1000 Kg] AM(X)24-SR-T Electrical connection screw terminal (for 26 to 14 GA wire) unprotected (NEMA 1/IP20) Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp, 1/2 self-centered default. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The actuator operates in response to a 2 to 10 VDC, or with the addition of a 500 Ω resistor, a 4 to 20 ma control input from an electronic controller or positioner. A 2 to 10 VDC feedback signal is provided for position indication or master-slave applications. The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The AM(X) series provides 95 of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. The AM(X)24-SR actuators use a sensorless brushless DC motor, which is controlled by an Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. 1/2 to 1.05 [12.7 to 26.67] 2/5 to 1.05 [10 to 26.67] 2.2 [56] 3.46 [88] 1.18 [30] 4.06 [103] 5.47 [139] 4.3 [109] To center of mounting slot. 2 [50.8] 2.49 [63.4] D122 219

AM(X)24-SR(-T) Proportional, Non-Spring Return, 24 V, for 2 to 10 VDC or 4 to 20 ma Accessories K-SA Reversible Clamp ZG-100 Universal Mounting racket ZG-101 Universal Mounting racket ZG-103 Universal Mounting racket ZG-104 Universal Mounting racket Z-SMA AM/SM to AM Retrofit Mounting racket ZG-NMA Crank arm Adaptor Kit AV8-25 Universal Shaft Extension ZG-JSA (-1, 2, 3) Jackshaft Adaptors for Hollow Jackshafts ZS-T Terminal Cover NEMA 2 ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing Tool-06 8 mm & 10 mm Wrench S1A, S2A Auxiliary Switch (es) P370 Shaft Mount Auxiliary Switch P A Feedback Potentiometers SGA24 Min positioners in NEMA 4 housing SGF24 Min positioners for flush panel mounting PTA-250 Pulse Width Modulation Interface IRM-100 Input Rescaling Module ADS-100 Analog to Digital Switch ZG-R01 Resistor for 4 to 20 ma Conversion NSV24 US attery ack-up Module ZG-X40 Transformer NOTE: When using AM(X)24-SR actuators, only use accessories listed on this page. Wiring Diagrams 1 Provide overload protection and disconnect as required. 2 CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 5 Only connect common to neg. ( ) leg of control circuits. The ZG-R01 500 Ω resistor converts the 4 to 20 ma control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W257_08 Typical Specification Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05 diameter. Actuators must provide proportional damper control in response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 ma control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. If required, actuator will be provided with screw terminal strip for electrical connections (AMX24-SR-T). Run time shall be constant and independent of torque. A 2 to 10 VDC feedback signal shall be provided for position indication. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. 2 to 10 VDC control 4 to 20 ma control W257_08 220

AMX120-SR Proportional, Non-Spring Return, 100 to 240 VAC, for 2 to 10 VDC or 4 to 20 ma Torque min. 180 in-lb for control of damper surfaces up to 45 sq ft. Technical Data AMX120-SR Power supply 100 to 240 VAC, 50/60 Hz (nominal) 85 to 265 VAC, 50/60 Hz (tolerance) Power consumption 4 W (1 W) Transformer sizing 7.5 VA (Class 2 power source) Electrical connection 18 GA appliance rated cable 1/2 conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload protection electronic throughout 0 to 95 rotation Operating range Y 2 to 10 VDC, 4 to 20 ma Input impedance 100 kω (0.1 ma), 500 Ω Feedback output U 2 to 10 VDC (max 0.5 ma) Angle of rotation max. 95, adjust. with mechanical stop Torque 180 in-lb [20 Nm] Direction of rotation reversible with switch actuator will move: =CCW with decreasing control signal (10 to 2V) =CW with decreasing control signal (10 to 2V) Position indication reflective visual indicator (snap-on) Manual override external push button Running time 300 seconds 150 seconds 95 seconds constant independent of load Humidity 5 to 95% RH non condensing (EN 60730-1) Ambient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA 2, IP54, UL enclosure type 2 Housing material UL94-5VA Agency listings culus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC Noise level <45d(A) Servicing maintenance free Quality standard ISO 9001 2.2 lbs [1.0 Kg] Rated Impulse Voltage 4kV, Type of action 1, Control Pollution Degree 3. For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp, 1/2 self-centered default. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The actuator operates in response to a 2 to 10 VDC, or with the addition of a 500 Ω resistor, a 4 to 20 ma control input from an electronic controller or positioner. A 2 to 10 VDC feedback signal is provided for position indication or master-slave applications. The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The AMX series provides 95 of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. The AMX120-SR actuators use a sensorless brushless DC motor, which is controlled by an Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. D143_2 223

AMX120-SR Proportional, Non-Spring Return, 100 to 240 VAC, for 2 to 10 VDC or 4 to 20 ma Accessories K-SA Reversible Clamp ZG-100 Universal Mounting racket ZG-101 Universal Mounting racket ZG-103 Universal Mounting racket ZG-104 Universal Mounting racket Z-SMA AM/SM to AM Retrofit Mounting racket ZG-NMA Crank arm Adaptor Kit AV8-25 Universal Shaft Extension ZG-JSA (-1, 2, 3) Jackshaft Adaptors for Hollow Jackshafts ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing Tool-06 8 mm & 10 mm Wrench S1A, S2A Auxiliary Switch (es) P370 Shaft Mount Auxiliary Switch P A Feedback Potentiometers SGA24 Min positioners in NEMA 4 housing SGF24 Min positioners for flush panel mounting PTA-250 Pulse Width Modulation Interface IRM-100 Input Rescaling Module ADS-100 Analog to Digital Switch ZG-R01 Resistor for 4 to 20 ma Conversion NSV24 US attery ack-up Module ZG-X40 Transformer NOTE: When using AMX120-SR actuators, only use accessories listed on this page. Wiring Diagram 1 Provide overload protection and disconnect as required. 2 CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 5 Only connect common to neg. ( ) leg of control circuits. Meets culus or UL and CSA Standard requirements without the need of an electrical ground connection. The ZG-R01 500 Ω resistor converts the 4 to 20 ma control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. W374_08 Typical Specification Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05 diameter. Actuators must provide proportional damper control in response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 ma control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. A 2 to 10 VDC feedback signal shall be provided for position indication. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. 2 to 10 VDC or 4 to 20 ma control 224

AM(X)24-MFT Proportional, Non-Spring Return, 24 V, Multi-Function Technology Torque min. 180 in-lb for control of damper surfaces up to 45 sq ft. Technical Data AM(X)24-MFT Power supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption 3.5 W (1.3 W) Transformer sizing 6 VA (Class 2 power source) Electrical connection 18 GA plenum rated cable 1/2 conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload protection electronic throughout 0 to 95 rotation Operating range Y 2 to 10 VDC, 4 to 20 ma (default) variable (VDC, PWM, floating point, on/off) Input impedance 100 kω (0.1 ma), 500 Ω 1500 W (PWM, floating point, on/off) Feedback output U 2 to 10 VDC, 0.5 ma max VDC variable Angle of rotation max. 95, adjustable with mechanical stop electronically variable Torque 180 in-lb [20 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button Running time 150 seconds (default) variable (90 to 350 seconds) Humidity 5 to 95% RH non condensing (EN 60730-1) Ambient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA 2, IP54, UL enclosure type 2 Housing material UL94-5VA Agency listings culus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC Noise level <45d(A) Servicing maintenance free Quality standard ISO 9001 2.6 lbs [1.2 kg] Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp, 1/2 self-centered default. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The default parameters for 2 to 10 VDC applications of the MFT actuator are assigned during manufacturing. If necessary, custom versions of the actuators can be ordered. The parameters can be changed by two means: pre-set and custom configurations from elimo or on-site configurations using the elimo PC-Tool software. The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The AM(X) series provides 95 of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. The AM(X)24-MFT actuators use a brushless DC motor, which is controlled by an Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. 1/2 to 1.05 [12.7 to 26.67] 2/5 to 1.05 [10 to 26.67] 3.46" [88] 2.49" [63.4] 1.18" [30] 4.06" [103] 4.3" [109] 5.2" [131] 8.3" [211] 2" [50.8] D143 225

AM(X)24-MFT Proportional, Non-Spring Return, 24 V, Multi-Function Technology Accessories K-SA Reversible Clamp ZG-100 Universal Mounting racket ZG-101 Universal Mounting racket ZG-103 Universal Mounting racket ZG-104 Universal Mounting racket Z-SMA AM/SM to AM Retrofit Mounting racket ZG-AMA Crank arm Adaptor Kit AV8-25 Universal Shaft Extension ZG-JSA (-1, 2, 3) Jackshaft Adaptors for Hollow Jackshafts ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing Tool-06 8 mm & 10 mm Wrench S1A, S2A Auxiliary Switch (es) P370 Shaft Mount Auxiliary Switch P A Feedback Potentiometers SGA24 Min positioners in NEMA 4 housing SGF24 Min positioners for flush panel mounting ADS-100 Analog to Digital Switch ZG-R01 Resistor for 4 to 20 ma Conversion NSV24 US attery ack-up Module ZG-X40 Transformer NOTE: When using AM(X)24-MFT actuators, only use accessories listed on this page. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. VDC/4-20 ma W399_08 W399_08 Typical Specification Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05 diameter. Actuators must provide proportional damper control in response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 ma control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. Wiring Diagrams 1 Provide overload protection and disconnect as required. 2 CAUTION Equipment Damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 4 5 8 9 Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VAC line. Contact closures A & also can be triacs. A & should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. PWM On/Off control W399_08 W399_08 The ZG-R01 500 Ω resistor may be used. Floating Point control 226

AMCX24-MFT Proportional, Non-Spring Return, 24 V, Multi-Function Technology Torque min. 180 in-lb for control of damper surfaces up to 45 sq ft. Technical Data AMCX24-MFT Power supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption 4 W (1.25 W) Transformer sizing 6 VA (Class 2 power source) Electrical connection 18 GA plenum rated cable 1/2 conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload protection electronic throughout 0 to 95 rotation Operating range Y 2 to 10 VDC, 4 to 20 ma (default) variable (VDC, PWM, floating point, on/off) Input impedance 100 kω (0.1 ma), 500 Ω 1500 W (PWM, floating point, on/off) Feedback output U 2 to 10 VDC, 0.5 ma max VDC variable Angle of rotation max. 95, adjustable with mechanical stop electronically variable Torque 180 in-lb [20 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button Running time 35 seconds (default) variable (35 to 120 seconds) Humidity 5 to 95% RH non condensing (EN 60730-1) Ambient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA 2, IP54, UL enclosure type 2 Housing material UL94-5VA Agency listings culus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC Noise level <45d(A) Servicing maintenance free Quality standard ISO 9001 2.6 lbs [1.2 kg] For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp, 1/2 self-centered default. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The default parameters for 2 to 10 VDC applications of the MFT actuator are assigned during manufacturing. If necessary, custom versions of the actuators can be ordered. The parameters can be changed by two means: pre-set and custom configurations from elimo or on-site configurations using the elimo PC-Tool software. The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The AMX series provides 95 of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. The AMCX24-MFT actuators use a brushless DC motor, which is controlled by an Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions 1/2 to 1.05 [12.7 to 26.67] 2/5 to 1.05 [10 to 26.67] 3.46" [88] 2.49" [63.4] 1.18" [30] 4.06" [103] 4.3" [109] 5.2" [131] 8.3" [211] 2" [50.8] D143 229

AMCX24-MFT Proportional, Non-Spring Return, 24 V, Multi-Function Technology Accessories K-SA Reversible Clamp ZG-100 Universal Mounting racket ZG-101 Universal Mounting racket ZG-103 Universal Mounting racket ZG-104 Universal Mounting racket Z-SMA AM/SM to AM Retrofit Mounting racket ZG-AMA Crank arm Adaptor Kit AV8-25 Universal Shaft Extension ZG-JSA (-1, 2, 3) Jackshaft Adaptors for Hollow Jackshafts ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing Tool-06 8 mm & 10 mm Wrench S1A, S2A Auxiliary Switch(es) P370 Shaft Mount Auxiliary Switch P A Feedback Potentiometers SGA24 Min positioners in NEMA 4 housing SGF24 Min positioners for flush panel mounting ADS-100 Analog to Digital Switch ZG-R01 Resistor for 4 to 20 ma Conversion NSV24 US attery ack-up Module ZG-X40 Transformer Note: When using AMCX24-MFT actuators, only use accessories listed on this page. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. VDC/4-20 ma W399_08 W399_08 Typical Specification Proportional control damper actuators shall be electronic direct coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05 diameter. Actuators must provide proportional damper control in response to a 2 to 10 VDC or, with the addition of a 500 Ω resistor, a 4 to 20 ma control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. Wiring Diagrams 1 Provide overload protection and disconnect as required. 2 CAUTION Equipment Damage! A ctuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 4 5 8 9 Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VAC line. Contact closures A & also can be triacs. A & should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. PWM On/Off Off control W399_08 W399_08 The ZG-R01 500 Ω resistor may be used. Floating Point control 230

AMX24-MFT95 Proportional, Non-Spring Return, 24 V, 0 to 135 Ω Input Torque min. 180 in-lb for control of damper surfaces up to 45 sq ft. Technical Data AMX24-MFT95 Power supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption 3.5 W (1.3 W) Transformer sizing 6 VA (Class 2 power source) Electrical connection 18 GA plenum rated cable 1/2 conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload protection electronic throughout 0 to 95 rotation Operating range WR 135 Ω Honeywell Electronic Series 90, 0 to 135 Ω input Feedback output U 2 to 10 VDC, 0.5 ma max Angle of rotation max. 95, adjustable with mechanical stop electronically variable Torque 180 in-lb [20 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button Running time 150 seconds (default) variable (90 to 350 seconds) Humidity 5 to 95% RH non condensing (EN 60730-1) Ambient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA 2, IP54, UL enclosure type 2 Housing material UL94-5VA Agency listings culus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC Noise level <45d(A) Servicing maintenance free Quality standard ISO 9001 2.6 lbs [1.2 kg] Rated Impulse Voltage 800V, Type of action 1.AA, Control Pollution Degree 3. For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp, 1/2 self-centered default. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The default parameters for 0 to 135 Ω input applications of the MFT95 actuator are assigned during manufacturing. If necessary, custom versions of the actuators can be ordered. The parameters can be changed by two means: pre-set and custom configurations from elimo or on-site configurations using the elimo PC-Tool software. The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The AMX series provides 95 of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. The AMX24-MFT95 actuators use a brushless DC motor, which is controlled by an Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. 1/2 to 1.05 [12.7 to 26.67] 2/5 to 1.05 [10 to 26.67] 3.46" [88] 2.49" [63.4] 1.18" [30] 4.06" [103] 4.3" [109] 5.2" [131] 8.3" [211] 2" [50.8] D143 231

AMX24-MFT95 Proportional, Non-Spring Return, 24 V, 0 to 135 Ω Input Accessories K-SA Reversible Clamp ZG-100 Universal Mounting racket ZG-101 Universal Mounting racket ZG-103 Universal Mounting racket ZG-104 Universal Mounting racket Z-SMA AM/SM to AM Retrofit Mounting racket ZG-AMA Crank arm Adaptor Kit AV8-25 Universal Shaft Extension ZG-JSA (-1, 2, 3) Jackshaft Adaptors for Hollow Jackshafts ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing Tool-06 8 mm & 10 mm Wrench S1A, S2A Auxiliary Switch (es) P370 Shaft Mount Auxiliary Switch P A Feedback Potentiometers NSV24 US attery ack-up Module ZG-X40 Transformer NOTE: When using AMX24-MFT95 actuators, only use accessories listed on this page. Typical Specification Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05 diameter. Actuators must provide proportional damper control in response to 0 to 135 Ω control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. Wire Colors 1 = lack 2 = Red Override 21 Line Volts 21 Line Volts Line Volts 22 3 = White 4 = Pink 24 VAC Transformer 135 Ω A 24 VAC Transformer W R Controller A 5 = Gray 6 = Orange 5 lk (1) Common Red (2) + Hot 23 Pnk (4) W 24 Wht (3) R Gry (5) Org (6) U5 Output 2 to 10 VDC -MFT95 lk (1) Common Red (2) + Hot 23 Pnk (4) W 24 Wht (3) R Gry (5) Org (6) U5 Output 2 to 10 VDC -MFT95 Wnew60408_6 Wiring Diagrams 5 Actuators with plenum rated cable do not have numbers on wires; use color codes instead. Actuators with appliance cables are numbered. 21 Provide overload protection and disconnect as required. 22 Actuators and controller must have separate transformers. 23 Consult controller instruction data for more detailed information. Resistor value depends on the type of controller and the number of 24 actuators. No resistor is used for one actuator. Honeywell resistor kits may also be used. 25 To reverse control rotation, use the reversing switch. Line Volts Series 90 Controller 24 21 Shunting Resistor 21 Line Volts 22 24 VAC Transformer R W R W R 22 23 W H205 Changeover Controller Occupied Contact To other actuators S963A Minimum Position Potentiometer Wiring multiple actuators to a Series 90 controller using a minimum position potentiometer. Low Limit Control High Limit Control 21 Line Volts 24 VAC Transformer 22 Series 90 Controller 21 Line Volts W R W R Series 90 low limit control 135 Ω for 0 to 50% control 280 Ω for 0 to 100% control 24 VAC Transformer 22 Series 90 Controller W R W Series 90 high limit control - 280 Ω R 5 lk (1) Common Red (2) + Hot 25 Pnk (4) W Wht (3) R Gry (5) Org (6) U5 Output 2 to 10 VDC -MFT95 lk (1) Common Red (2) + Hot 23 Pnk (4) W 25 Wht (3) R Gry (5) Org (6) U5 Output 2 to 10 VDC -MFT95 5 lk (1) Common Red (2) + Hot 23 Pnk (4) W 24 Wht (3) R Gry (5) Org (6) U5 Output 2 to 10 VDC -MFT95 5 lk (1) Common Red (2) + Hot 23 Pnk (4) W 24 Wht (3) R Gry (5) Org (6) U5 Output 2 to 10 VDC -MFT95 Wnew60408_6 W016 Wnew60408_6 W017 Wnew60408_6 232

AMX24-PC Proportional, Non-Spring Return, 24 V, 0 to 20V Phasecut Torque min. 180 in-lb for control of damper surfaces up to 45 sq ft. Technical Data AMX24-PC Power supply 24 VAC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption 3.5 W (1.3 W) Transformer sizing 5.5 VA (Class 2 power source) Electrical connection 18 GA plenum rated cable 1/2 conduit connector protected NEMA 2 (IP54) 3 ft [1m] 10 ft [3m] 16 ft [5m] Overload protection electronic throughout 0 to 95 rotation Operating range Y 0 to 20 V phasecut Control is only for the postiive part of the sine wave (max of 10 volts) Input impedance 8 kω (50 mw) Feedback output U 2 to 10 VDC, 0.5 ma max VDC variable Angle of rotation max. 95, adjustable with mechanical stop electronically variable Torque 180 in-lb [20 Nm] Direction of rotation reversible with switch Position indication reflective visual indicator (snap-on) Manual override external push button Running time 150 seconds (default) Humidity 5 to 95% RH non condensing (EN 60730-1) Ambient temperature -22 F to 122 F [-30 C to 50 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing NEMA 2, IP54, UL enclosure type 2 Housing material UL94-5VA Agency listings culus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EEC and 2006/95/EC Noise level <45d(A) Servicing maintenance free Quality standard ISO 9001 2.6 lbs [1.2 kg] Rated Impulse Voltage 800V, Type of action 1, Control Pollution Degree 3. For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.05 in diameter by means of its universal clamp, 1/2 self-centered default. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled (only the positive part of the sine wave) to the damper shaft. The actuator operates in response to 0 to 20V phasecut control input only on the positive part of the sine wave from an electronic controller or positioner. A 2 to 10 VDC feedback signal is provided for position indication. The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The AMX series provides 95 of rotation and a visual indicator indicates position of the actuator. When reaching the damper or actuator end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. The AMX24-PC actuators use a brushless DC motor, which is controlled by an Specific Integrated Circuit (ASIC). The ASIC monitors and controls the actuator s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. 1/2 to 1.05 [12.7 to 26.67] 2/5 to 1.05 [10 to 26.67] 3.46" [88] 2.49" [63.4] 1.18" [30] 4.06" [103] 4.3" [109] 5.2" [131] 8.3" [211] 2" [50.8] D143 233

AMX24-PC Proportional, Non-Spring Return, 24 V, 0 to 20V Phasecut Accessories K-SA Reversible Clamp ZG-100 Universal Mounting racket ZG-101 Universal Mounting racket ZG-103 Universal Mounting racket ZG-104 Universal Mounting racket Z-SMA AM/SM to AM Retrofit Mounting racket ZG-AMA Crank arm Adaptor Kit AV8-25 Universal Shaft Extension ZG-JSA (-1, 2, 3) Jackshaft Adaptors for Hollow Jackshafts ZS-100 Weather Shield - Steel ZS-150 Weather Shield - Polycarbonate ZS-260 Explosion Proof Housing ZS-300 (-1) (-5) NEMA 4X Housing Tool-06 8 mm & 10 mm Wrench S1A, S2A Auxiliary Switch (es) P370 Shaft Mount Auxiliary Switch P A Feedback Potentiometers NSV24 US attery ack-up Module ZG-X40 Transformer NOTE: When using AMX24-PC actuators, only use accessories listed on this page. Typical Specification Proportional control damper actuators shall be electronic direct-coupled type, which require no crank arm and linkage and be capable of direct mounting to a shaft up to 1.05 diameter. Actuators must provide proportional damper control in response to 0 to 20V phasecut control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be culus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. Wiring Diagram 1 Provide overload protection and disconnect as required. 2 CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 1 Line Volts 24 VAC Transformer Control Signal ( ) 0 to 20 V Phasecut (+) Proportional Control lk (1) Common Red (2) Hot + 3 Pnk (6) Y Input, 0 to 20V phasecut Org (5) U Output, 2 to 10V PC 2 W185 234