Operating manual. High-voltage testing adapter VAS 6558A/30. Operating manual. Customer documentation Revision: 00 Version: 07/2018

Similar documents
Installation manual wall-mounted distributor

Installation manual portable distributors

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Operating instructions

Mod: KLD6-12/35XLAS-N

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

ON SAFEGUARD S ON SAFEGUARD M

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Exchange of rollers from the XTS-Mover

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

WK 120QMM-6M/Z EL 120QMM-6M/M12

SERVICE MANUAL

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

HST -LS Interlocking device (Translation of Original Manual)

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

PISTOL SHAPE SPOTLIGHT 500,000 CANDLE POWER ASSEMBLY & OPERATING INSTRUCTIONS Mission Oaks Blvd., Camarillo, CA 93011

Ulyser Component Maintenance Manual

SCOPELITE TIMING LIGHT OPERATING MANUAL

User s Manual Power Supply IM E. 5th Edition

HST-BL-2830MS & HST-BL-2830MS-USA

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

Operating Instructions

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

BMW i. Freude am Fahren. Wallbox PURE. Installation instruction

362 Clamp Meter. Users Manual

User Manual Hoof trimmingcrush:sa0010. Version: User manual. Hoof trimming crush SA0010

Turbocharger / TPS-H Original assembly instructions English

MANUAL. Single charger

COOLING SYSTEM PRESSURE TEST KIT

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

HQZ & RBM MODEL LIFT & TRANSFERS

SUPER PUMP OUT SYSTEM

Patron Call System. Scope s DataPage II Lite & NexCall Coaster. Operators/Installation Manual

BYD B-Box Limited Warranty Letter

Swing Arm Magnifying Lamp

Turbocharger / TPL-B Original assembly instructions English

BroadBand PowerShield. 20 AHr Battery. User Manual

Oil-free piston compressors KK and piston vacuum pumps KV

Energy-Saving Under-Cabinet Light. Assembly and safety advice Z30802A-BS Z30802B-BS

CENTAX-TEST Assembly and operating instructions 053C GB3. M EN Rev. 1

900 PEAK AMP PORTABLE JUMP STARTER

DRVRMDMOTL Motorized Linear Drive. DRVMDMOTLR Motorized Linear and Rotary Drive. Instruction Manual

CONTACTS EGR VALVE TESTER 66248

p.t.o. Slip clutch Read this material before using this product. Failure to do so can result in serious injury. Save this manual.

Turbocharger / A100-L Original assembly instructions English

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

4-VOLT LITHIUM-ION AUTO-LOAD SCREWDRIVER w/led WORKLIGHT

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

BioCompact 25/50. Gebrauchsanleitung und Garantie Operating instructions and Guarantee

VAS 5906A. Operating Manual Battery Charger. Theodor-Heuss-Straße 4 D Herzberg am Harz Germany. Phone Fax

MODEL 7400 STRUT SPRING COMPRESSOR

original operating manual Operating manual Translation of the Item-No.: ,

User Manual SPOTTING SCOPE X 60

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

MODEL 7600 STRUT SPRING COMPRESSOR

CP9125 OBDII PocketScan Code Reader

English. Instruction and operation manual S 212. Dew point sensor

Operating Instructions for PAC800 Battery Charger

I. Safety precautions

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

Owner s Manual & Safety Instructions

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

Installation and Connection: Installation and Operating Manual

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

SensoLyt 700 SensoLyt 700 SW

25 GALLON PORTABLE OIL LIFT

Cabling for power, control, and video must be run to the installation site before the mount is installed.

RECHARGEABLE 24 LED WORK LIGHT

Installation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1

Operating Instruction. Junction Box 80 A/125 A. Part-Number BAL a-EN Original document page 1 of 20

Instant Wine Aerator USER MANUAL SAVE THIS MANUAL FOR FUTURE REFERENCE

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

DIAGNOSTIC TOOL BATTERY

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

TESTER SET SOCKET & VOLTAGE

CAMBELT TENSION GAUGE

Model C230 Pump Controller

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

BYD B-Box Limited Warranty Letter

Installation and Operating Instructions. Solar System Controller ISC3020

CONTACTS RELAY TESTER 66249

Owner s Manual & Safety Instructions

CENTAX-SEC Series B Assembly and operating instructions CX BFS1-LE/SE-**-B M EN Rev. 1

82V LITHIUM-ION BATTERY CHARGER GC 400

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

KeContact P20. User manual

Important instructions

Inhalt. Granule jet blasting device PG 5 8. Owner s Manual. Translation of the original instructions

Operating Instructions & Parts Manual. Fuel Tank Adapter

HEINE NT4 MED V

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

Assembly instructions

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

RECHARGEABLE POWER OUTAGE LED LIGHT INSTRUCTION MANUAL

Transcription:

CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 1 of 12

Imprint Title: of high-voltage testing adapter Manufacturer: Copyright: CAR-connect GmbH Am Egelingsberg 8 D-38542 Leiferde Phone:+49 (0) 5373 92197-10 Fax:+49 (0) 5373 92197-88 info@car-connect.cc www.car-connect.cc Copyright 2018 CAR-connect GmbH. All rights reserved. All text, images and graphics are subject to copyright and other laws for protection of intellectual property. Reproduction: Reproduction or reprint - even in part - always requires the written consent of the manufacturer. CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 2 of 12

Table of Contents 1 General... 4 1.1 Notes on the manual... 4 1.2 Legend of the icons in this operating manual... 5 1.3 Markings on the testing adapter... 6 2 Engineering... 7 2.1 Mode of operation... 7 2.2 Safety instructions... 7 2.3 Maintenance and repair... 8 3 Unpacking manual... 9 4 Technical drawing... 10 5 Warranty... 11 6 Storing the high-voltage testing adapter... 11 7 Technical data... 12 8 Cleaning and decontamination... 12 CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 3 of 12

1 General 1.1 Notes on the manual State of the art The testing adapter corresponds to the current state of the art. For safe operation of the equipment, you should operate it in a professional and safety-conscious way. Reading the operating manual Read the operating manual carefully and thoroughly before using the testing adapter. The operating manual is binding for every application case described. It explains the intended use of the testing adapter. Action All steps of action and application necessary for the correct operation of the device are described in this operating manual and in the referenced documents. Deviating work instructions must be approved expressly by the manufacturer. Use the testing adapter only as intended in order to avoid personal injury and property damage. General information Testing, installation and repair work may only be performed by staff trained by the manufacturer. If faults occur, only those faults may be remedied independently, for which the corresponding maintenance processes are marked in the manufacturer s training documents. CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 4 of 12

1.2 Legend of the icons in this operating manual Follow all instruction and safety rules in this operating manual. In this operating manual, some sections are marked with internationally known warning symbols, hazard warnings and general mandatory signs. The individual pictograms are explained below. Follow the operating manual High voltage! Caution: Risk of fatal injury! Follow general instructions Warning of dangerous electrical voltage Prohibition for people with pacemakers Please note the following! CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 5 of 12

1.3 Markings on the testing adapter CE-marking Protective insulation (protection class II) Do not dispose of in the household waste Read the operating manual before use High voltage Caution! Fatal hazard Type designation with markings Quality approval mark with serial number CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 6 of 12

2 Engineering 2.1 Mode of operation The is a testing adapter for measurement of the absence of voltage on high-voltage system. It is used in electric vehicles in conjunction with the high-voltage measuring module VAS 6558A for checking the power measurements between the charger and the power electronics. The high-voltage test adapter can be used to check the absence of voltage directly via the high-voltage cables without exposing further high-voltage components on the high-voltage battery. Using the high-voltage testing adapter and the high-voltage measuring module, the following measurements can be conducted on the high-voltage system: 1. Measurement of the absence of voltage Measurement of the absence of voltage at the measurement sockets of the high-voltage testing adapter a. between HV+ and HVb. between HV+ and vehicle ground c. between HV- and vehicle ground 2. Insulation resistance measurement (high-voltage lines, charger) 3. Continuity measurement (high-voltage lines) 4. Equipotential bonding measurement 2.2 Safety instructions The high-voltage testing adapter described here is intended exclusively to determine measured values in conjunction with the high-voltage measuring module VAS 6558A. The diagnostic adapter may only be used for such purposes, but do not signify any danger to man or machine. Use the high-voltage testing adapter set only as described in the operating manual! Every change to the test adapters as well as any other application than described are in the scope of responsibility of the operator. Make sure that the testing adapter set (VAS 6558A und VAS 6558A/30) is in perfect condition and all functions are guaranteed for safe operation. Follow the accident prevention regulations applicable in the respective countries. Wear your personal protective equipment when working on the high-voltage battery. CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 7 of 12

2.3 Maintenance and repair Follow the following general instructions: Never throw or drop the high-voltage testing adapter VAS 6558A/30. Never use the high-voltage testing adapter for purposes other than the intended ones and do not let untrained staff use it! Make sure that the high-voltage testing adapter set VAS 6558A/30 is used in a work area which is free of heat sources (maximum 40 C / 77 F), corrosive fluids, oil, and fat. The high-voltage testing adapter must never be used in areas exposed to hazard of explosion. Make sure that the high voltage test adapter is placed on a non-slip surface and that the device cannot be damaged. Only use tools and accessories, which are not worn out and which have no damage. Tools or accessories with damage can result in serious injuries! The manufacturer shall not be liable for damages caused by improper repairs or use of non-original spare parts. Incorrect operations of the testing adapter that lead to damage to the device shall make any warranty void. If in doubt, always contact a professionally trained company or the CARconnect company. The corresponding contact address is in this manual. Replace components if the damage is visible. Damaged components may cause serious injuries! Check contacts and connections for damage. Only authorised personnel trained by CAR-connect are allowed to perform maintenance and repair work. For more information about the service work and training, please contact us at our service address: CAR-connect GmbH Am Egelingsberg 8 D-38542 Leiferde Germany CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 8 of 12

3 Unpacking manual C D B Packaging and scope of supply of Scope of supply no. Name Number VAS-no. Article no. B 1 ASE 405 470 00 000 C Storage and transport case (plastic) 1 D in 37 languages (memory stick) 1 CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 9 of 12

4 Technical drawing C B D CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 10 of 12

5 Warranty A warranty of 24 months is granted for diagnostic adapters of CAR-connect company against defects in material or workmanship. The warranty period begins on the date of delivery confirmed on the invoice or the delivery note. The warranty applies to the user/buyer if the diagnostic adapter is purchased from an authorised retail outlet and they are used as intended. The warranty is void if the diagnostic adapter has been used for other purposes contrary to its intended use. Likewise, the warranty shall expire if the diagnostic adapters are not used as described in this operating manual. In the case of defect or error, only faulty parts are repaired or replaced by CAR-connect at their discretion. Service address: CAR-connect GmbH Am Egelingsberg 8 D-38542 Leiferde Germany 6 Storing the high-voltage testing adapter Store the high-voltage testing adapter in its labelled storage case. CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 11 of 12

7 Technical data Connection of measurement sockets: CAT I CAT II CAT III 1,000 V DC max. 600 V DC max. 300 V DC max. Maximum rated current: 1 ma Indoor use. The high-voltage testing adapter can be used at temperature up to 50 C. The high-voltage testing adapter is specified for a relative humidity up to 85%. The high-voltage testing adapter is specified for storage at -20 to 60 C. 8 Cleaning and decontamination Cleaning and decontamination are permitted only with a dry cloth. CAR-connect GmbH info@car-connect.cc www.car-connect.cc Page 12 of 12