Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Similar documents
Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Overloadrelay,10-16A,1N/O+1N/C. Articleno

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Contactelement,1N/C,frontmount,6.contact,screwconnection. Product range RMQ-Titan (drilling dimensions 22.5 mm)

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Application Mini Contactors for Motors and Resistive Loads

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Application Mini Contactors for Motors and Resistive Loads

CA Z-EN Overload relays, CT-operated overload relays

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Product range RMQ-Titan (drilling dimensions 22.5 mm) Description Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/ Minden, Germany

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Electronic overload relay EF65, EF96 and EF146

AF40... AF96 3-pole contactors Technical data

Electronic overload relays EF205 and EF370

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF65 and TF96

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

ASL09..S 3-pole Contactors - Spring Terminals

Thermal Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

PKZ and PKE motor-protective circuit-breakers

Protection Equipment

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

SIRIUS 3RU2 Thermal Overload Relays

Flexible. Intelligent. Trendsetting.

MS General Information Extended Product Type: MS

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

IEC CONTACTORS AND OVERLOAD RELAYS

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Manual motor starter magnetic only MO325

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

3 - Protection components Motor circuit-breakers

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Thermal Overload Relays - WEG RW Series, 2 Pole

TAE pole Contactors

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

AF series contactors (9 2650)

CI-TI Contactors and motor starters Types CI 61 - CI 98

Thermal overload relays Type TA Class 10

Manual motor starter MS132

MS25, MST25, MS20, MST20

Technical Information

Manual Motor Starters. Meta-MEC

Manual motor starter MS132

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Industrial Contactors CTX 3 3P 185A - 800A

Technical data for manual motor starters Type MS325

ZS4-SF1 Screw Clamp Terminal Block

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AE 9... AE 40 Contactors NE... Contactor Relays

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

BETA Switching Switches and Light Indicators

AF series contactors (9 2650)

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

4 - Miniature controls

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Essential equipment for all your requirements

Solid State Relays, 3-phase

Manual motor starter MS132

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Special Purpose Fuses

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

ZE motor-protective relay Overload monitoring of EEx e motors

Short form catalogue. Motor protection & control

Protection Equipment. 5/2 Introduction

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Manual motor starter MS116

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Manual motor starter MS116

Transcription:

Deliveryprogramme Overloadrelay,24-40A,1N/O+1N/C Partno. ZB65-40 Articleno. 278458 CatalogNo. XTOB040DC1 Product range Overload relay ZB up to 150 A Frame size ZB65 Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102 Description Test/off button Reset pushbutton manual/auto Trip-free release Mounting type Direct mounting I r A 24-40 Contact sequence Auxiliarycontacts N/O = Normally open 1 N/O N/C = Normally closed 1 N/C For use with DILM40, DILM50, DILM65, DILM72, DILMF40, DILMF50, DILMF65, DIULM40, DIULM50, DIULM65, SDAINLM70, SDAINLM90, SDAINLM115 Short-circuitprotection Type 1 coordination gg/gl A 125 Type 2 coordination gg/gl A 63 Notes Overload release: tripping class 10 A Short-circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. Suitable for protection of Ex e-motors. II (2) GD PTB 10 ATEX 3010 Observe manual MN03407005Z-DE/EN. Notes Fitted directly to the contactor Separate mounting 12/09/2015 278458 - HPL-ED2015 V18.0 EN 1 / 7

1 Contactor 2 Bases Technicaldata General Standards IEC/EN 60947, VDE 0660, UL, CSA Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open C -25 - +55 Enclosed C - 25-40 Temperature compensation Continuous Weight kg 0.25 Operating range to IEC/EN 60947 PTB: -5 C - +55 C Mechanical shock resistance g 10 Sinusoidal Shock duration 10 ms Degree of Protection IP00 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Mainconductingpaths Rated impulse withstand voltage U imp V AC 6000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V 690 Rated operational voltage U e V AC 690 Safe isolation to EN 61140 Between auxiliary contacts and main contacts V AC 440 Between main circuits V AC 440 Temperatur compensation residual error > 40 ºC 0.25 %/K Current heat loss (3 conductors) Lower value of the setting range W 3 Maximum setting W 7.5 Terminal capacities mm 2 Solid 2 mm 2 x (1-16) for use with ZB65-XEZ base: max. 1 x (1-16) Flexible with ferrule mm 2 1 (1 25) 2 x (1 10) When using 2 conductors use identical cross-section Stranded mm 2 1 x (16 25) Solid or stranded AWG 14-2 Terminal screw M6 Tightening torque Nm 3.5 Tools Pozidriv screwdriver Size 2 12/09/2015 278458 - HPL-ED2015 V18.0 EN 2 / 7

Standard screwdriver mm 1 x 6 Auxiliaryandcontrolcircuits Rated impulse withstand voltage U imp V 4000 Overvoltage category/pollution degree III/3 Terminal capacities mm 2 Solid mm 2 2 x (0.75 4) Flexible with ferrule 2 mm 2 x (0.75-2.5) Solid or stranded AWG 2 x (18-14) Terminal screw M3.5 Tightening torque Nm 0.8-1.2 Tools Pozidriv screwdriver Size 2 Standard screwdriver mm 1 x 6 Rated insulation voltage U i V AC 500 Rated operational voltage U e V AC 500 Safe isolation to EN 61140 between the auxiliary contacts V AC 240 Conventional thermal current I th A 6 Rated operational current I e A AC-15 Make contact 120 V I e A 1.5 220 V 230 V 240 V I e A 1.5 380 V 400 V 415 V I e A 0.5 500 V I e A 0.5 Break contact 120 V I e A 1.5 220 V 230 V 240 V I e A 1.5 380 V 400 V 415 V I e A 0.9 500 V I e A 0.8 DC-13 L/R - 15 ms 24 V I e A 0.9 60 V I e A 0.75 110 V I e A 0.4 220 V I e A 0.2 Short-circuit rating without welding Notes max. fuse A gg/gl 6 NotesAmbient temperature: Operating range to IEC/EN 60947, PTB: -5 C to +55 C Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated Main contacts terminal capacity solid and stranded conductors with ferrules: When using 2 conductors use identical cross-section See overlay Fuses for short-circuit rating time/current characteristic (please enquire) 6 mm flexible with ferrules to DIN 46228 Rated operational current DC-13, 60 V: N/O auxiliary contact 0.6 A at ZB65-XEZ max 1 x (1 16) DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 40 Heat dissipation per pole, current-dependent P vid W 3.1 Equipment heat dissipation, current-dependent P vid W 9.3 Static heat dissipation, non-current-dependent P vs W 0 Heat dissipation capacity P diss W 0 Operating ambient temperature min. C -25 Operating ambient temperature max. C 55 IEC/EN 61439 design verification 12/09/2015 278458 - HPL-ED2015 V18.0 EN 3 / 7

10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM6.0 Low-voltage industrial components (EG000017) / Thermal overload relay (EC000106) Electric engineering, automation, process control engineering / Low-voltage switch technology / Overload protection device / Thermal overload relay (ecl@ss8.1-27-37-15-01 [AKF075011]) Adjustable current range A 24-40 Max. rated operation voltage Ue V 690 Mounting method Direct attachment Type of electrical connection of main circuit Screw connection Number of auxiliary contacts as normally closed contact 1 Number of auxiliary contacts as normally open contact 1 Number of auxiliary contacts as change-over contact 0 Release class CLASS 10 Approvals Product Standards UL 508; CSA-C22.2 No. 14; IEC/EN 60947-4-1; IEC/EN 60947-5-1; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 12528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Specially designed for North America No Suitable for Branch circuits Max. Voltage Rating 600 V AC Degree of Protection IEC: IP00, UL/CSA Type: - 12/09/2015 278458 - HPL-ED2015 V18.0 EN 4 / 7

Characteristics These tripping characteristics are mean values of the spread at 20 C ambient temperature in a cold state. Tripping time depends on response current. On devices at operating temperature the tripping time of the overload relay drops to approx. 25 % of the read value. Specific characteristics for each individual setting range can be found in the manual. 12/09/2015 278458 - HPL-ED2015 V18.0 EN 5 / 7

Dimensions OFF Reset/ON With base ZB65-XEZ 12/09/2015 278458 - HPL-ED2015 V18.0 EN 6 / 7

Additionalproductinformation(links) IL03407008Z(AWA2300-2113)Overloadrelay IL03407008Z (AWA2300-2113) Overload relay ftp://ftp.moeller.net/documentation/awa_instructions/il03407008z2014_09.pdf 12/09/2015 Eaton Industries GmbH http://www.eaton.eu 12/2015 by Eaton Industries GmbH 278458 - HPL-ED2015 V18.0 EN 7 / 7