MR Modulo. Adjustable Constant Airflow Regulator

Similar documents
Constant Airflow Regulators & Registers

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

CH5000 Heat Recovery Ventilator

Product Information. Applications. Warranty. Lab Calibrated. Residential, Commercial, OEM. ABV Sizes Available Airflow Range THE USA PROUDLY MADE IN

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

Volume Flow Limiters Type VFL

Volumetric Flow Limiter VOLKOM

SINGLE DUCT TERMINAL UNITS

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

IrisControlDamper. For Adjustment and Measuring of Airflow.

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

For installation into ductwork

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Air Measuring Products AMD AMS IAQ

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

AMD-33 Air Measuring Station with VCD-33 Control Damper

FOR USE IN SOLUTION AIR HANDLING UNITS

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Introduction to Johnson Controls Dampers

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

3900 Dr. Greaves Rd. Kansas City, MO (816) FAX (816) ABD-SEA-E

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Model FSD-212. Combination FIRE SMOKE DAMPERS

2 - Air flow measuring sensors FloXact -Stick

CAV controllers Type RN

Motorized Fire Dampers

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Demand Based Static Pressure Reset Control for Laboratories

AD-1250 Airflow Measuring Station

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

RD-2000 Round Control Dampers

Laboratory Exhaust Systems

Installation, Operation and Maintenance Manual

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

series FSD-FLD Fire and smoke dampers UL Approval

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Ceiling swirl diffusers

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

HCD-230 Industrial Control Damper

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Installation, Operation and Maintenance Manual

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Model ND-2 Specification

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Model FSD-331 Combination Fire Smoke Dampers

Thermal Isolation. Break

Fixed Range Exhaust Flow Canopies for NU 540 (Series 1 ), NU 543 (Series 1 ) Class II, Type A2, Biological Safety Cabinets

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

AD-1251 Probe with Differential Pressure Transducer

LDV / LDVQ 5000 AIR VOLUME CONTROL VALVE INSTALLATION MANUAL. Date: 02 / 10 Reference # : F-36. w w w. p r i c e - h v a c. c o m

XeteX, Inc. All Rights Reserved.

MODEL FF50 CEILING FAN

RVP-R- VAV controller. In explosion-proof version

Explosion decoupling inside connected ductwork to protect separators

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Table of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5

Tube Axial Inline Fans

TRI-DEK FILTERS OVER 40 YEARS OF INNOVATION

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Variable Air Volume Distribution Units CII, September 1 st, Home

Fire, Smoke, and Combination Fire Smoke Dampers

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

STR Circular VAV Terminal Units

SQUARE INLINE CENTRIFUGAL FANS

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Technical Information

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC

COMPACT CAGE RACK VALVES

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Pressure control damper ERPA

Exhaust rail system 920 for stationary vehicles

Ballorex Venturi 3.1 Introduction

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

INSTALLATION INSTRUCTION

RM-1200 Slim Round Control Damper

VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565

AIR VOLUME TRANSMITTER / CONTROLLER IML

Safety & Installation Instructions

Design Considerations for Pressure Sensing Integration

LTG Air Distribution. Product Overview

MODEL 151B FIRE DAMPER

Transcription:

MR Modulo Adjustable Constant Airflow Regulator

2

MR Modulo balanced airflow with a twist Airflow balancing is the key to a properly commissioned HVAC system. A balanced system does not suffer from over-ventilation (noise, high temperatures, high energy consumption) or underventilation (poor air quality and uncomfortable temperatures). In tightly built structures, ventilation and air conditioning systems are specifically sized to guarantee that the proper amounts of air exit and enter the building. Actual operating airflows are often far from the original HVAC system design. Accurate balancing is nearly impossible with traditional balancing dampers. A system may start out balanced, but it is susceptible to pressure fluctuations. Maintaining system balance requires constant adjustments, which are costly and time consuming. Fluctuations are unavoidable, but Aldes has a dynamic solution that preserves system balance. The Aldes MR Modulo Adjustable Constant Airflow Regulator is a passive device that automatically compensates for changes in static pressure and adjusts to maintain the specified airflow value. The MR Modulo is an elegant, cost-effective solution. It is available in 5 diameters, and each device supports at least 7 airflow rates. Twist the rotating ring to change the airflow setpoint. Then simply insert the MR Modulo into duct or fittings. No tools, no balancing, no maintenance. Buildings large and small can benefit from the MR Modulo. Actual airflows = Design airflows Actual airflows = Design airflows Unbalanced HVAC system. Actual airflow is only at the specified rate in certain parts of the building. Balanced HVAC system. Actual airflow is at the specified rate throughout the entire building. 3

Features of the MR Modulo Guaranteed quality 100% test Every unit is run-tested. 5-year warranty. Easy to install 360 Compact No manual balancing. Tool-free airflow setting. Self-powered, no wiring or electricity required. Can be inserted into duct and fittings. Multi-position mounting. 4

MR Modulo Adjustable Constant Airflow Regulators balance airflows in ventilation or air conditioning ductworks. They fit easily into round ductwork to maintain constant and reliable airflow within a wide range of differential pressure (0.2-1.0 in. w.g./50-250 Pa). The MR Modulo s flexible membrane inflates and deflates according to the difference in pressure between the upstream and downstream flow, thus modifying the airflow. This principle of operation guarantees constant airflow regardless of pressure variations in the ductwork. Precise Airflow Regulation Regulating silicone membrane resists clogging and requires no maintenance. Silent operation: no mechanical clatter or other noise interference due to variations in pressure. Available in 5 diameters, each one with multiple airflow setpoints. Smart design Double-lip seal for secure, air-tight fit. Rotating ring for on-site airflow setting (patent pending). Made of recyclable, chlorine-free plastic that meets UL 2043 standards for flame and smoke generation. Stainless steel regulation spring. 5

Technical Details Airflow Range Ø 4 10-50 CFM (15-90 m 3 /h) Ø 5 10-50 CFM, 60-115 CFM (15-85 m 3 /h, 100-190 m 3 /h) Ø 6 60-140 CFM (100-240 m 3 /h) Ø 8 130-235 CFM (225-400 m 3 /h) Ø 10 175-385 CFM (300-650 m 3 /h) 0 60 120 175 235 296 355 415 470 (100) (200) (300) (400) (500) (600) (700) (800) CFM (m 3 /h) Airflow Accuracy: +/- 3 CFM (5 m 3 /h) for nominal flow 30 CFM (50 m 3 /h) +/- 10% for nominal flow > 30 CFM (50 m 3 h) Operating Pressure Range: 0.2-1.0 in. w.g. (50-250 Pa) Operating Temperature Range: 14 to 140 F (-10 to 60 C) Dimensions & Weight Ø Duct ØN ØB A Weight 4 (100 mm) 3.62 (92 mm) 4.13 (105 mm) 2.76 (70 mm) 0.26 lbs (0.12 kg) 5 * (125 mm) 4.57 (116 mm) 5.20 (132 mm) 2.76 (70 mm) 0.33 lbs (0.15 kg) 5 ** (125 mm) 4.57 (116 mm) 5.20 (132 mm) 4.33 (110 mm) 0.37 lbs (0.17 kg) Ø B 6 (150 mm) 5.79 (147 mm) 6.02 (153 mm) 4.65 (118 mm) 0.82 lbs (0.37 kg) 8 (200 mm) 7.48 (190 mm) 8.27 (210 mm) 5.67 (144 mm) 1.31 lbs (0.59 kg) 10 (250 mm) 9.37 (238 mm) 10.32 (262 mm) 7.05 (179 mm) 2.25 lbs (1.02 kg) Ø N * 10-50 CFM (15-85 m 3 /h) ** 60-115 CFM (100-190 m 3 /h) A 6

Installation Small diameters 360 Large diameters 1. Adjust the airflow setting. Twist the rotating adjustment ring until the desired airflow is reached (correlation table printed on the device). No tools are required. 2. Position the MR Modulo. Introduce the MR in the duct according to the arrow that shows the airflow direction. There is no recommendation regarding the membrane positioning. 3. Product localization. MR Modulo is delivered with a sticker that will need to be filled out on-site (diameter and airflow setting) and placed directly onto the duct to indicate where MR Modulo has been mounted. Product Information The following information is indicated on the product: Airflow direction Diameter in mm and inches Airflow settings correlation table Differential pressure operating range Part number Date of manufacture K 20 12,5 I 25 15 H 30 17,5 K 35 20 I 40 22,5 G 45 25 F 50 30 B 60 35 Warranty & Maintenance MR Modulo performance is not altered by clogging, therefore it requires practically no special maintenance. If the intended application includes air heavily loaded with grease or dust, a fitting with an access panel or door, such as that used for flame dampers, should be used. Five (5) year warranty 7

www.aldes.us Distributed By: American ALDES Ventilation Corporation 4521 19th Street Court East, Suite 104 - Bradenton, FL 34203 USA Tel: 941.351.3441 - Fax: 941.351.3442 - Toll-Free: 1.800.255.7749 2015 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice. 1015