GETTING STARTED GUIDE NI DO, 6 V to 30 V, Sourcing, 100 μs

Similar documents
GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

GETTING STARTED GUIDE NI DO, 5 V to 30 V, Sourcing, 1 μs

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

GETTING STARTED GUIDE NI AO, ±10 V, 16 Bit, 25 ks/s/ch Simultaneous

GETTING STARTED GUIDE NI DI, ±5 V to 24 V, Differential/Single-Ended, 500 ns

NI 9251 with mini XLR

GETTING STARTED GUIDE NI AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate

GETTING STARTED GUIDE NI AI, 51.2 ks/s/ch Simultaneous, Universal Measurements

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

CALIBRATION PROCEDURE NI Channel, ±0.5 V, 24-Bit Simultaneous, Channel-to-Channel Isolated Analog Input Module

Bracket and Assembly Dimensions

NI Pin DSUB to Screw-Terminal Connector Block

CALIBRATION PROCEDURE NI Channel, ±10 V, 16-Bit Analog Voltage Output Module

Industrial Rack Mount Kit for CompactRIO and CompactDAQ

Contents. Software. CALIBRATION PROCEDURE NI PXIe Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module. ni.com/manuals

Shielded Connector Block for the NI PXI/PXIe-2532/2532B

INSTALLATION GUIDE NI WSN-3291 Outdoor IP Enclosure For NI WSN-32xx Series Devices

INSTALLATION GUIDE NI 9921/9922 Outdoor IP Enclosure For NI WLS-9000 Series Devices

NI TB Introduction INSTALLATION INSTRUCTIONS. Terminal Block for the NI PXI/PXIe-2527

NI PS-15/16/17 Side Mount Brackets

SCXI Power Supply/Float Charger Installation Guide

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

362 Clamp Meter. Users Manual

PF 3100 ION PILOT CARD PRO.FIRE

- Wiring Brochure Mixing Expansion Module 440

Solenoid Operator 0516 / 1216

Mini Multimeter with Non-Contact Voltage Detector (NCV)

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Phase Sequence Tester

707Ex. Users Manual. ma Calibrator

Solenoid coil for control in potentially explosive areas Type BZ

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

i3000s/i2000 Flex AC Current Probe

F5 Platforms: FIPS Kit Installation MAN

INTERNATIONAL METAL ENGINEERING

BroadBand PowerShield. 20 AHr Battery. User Manual

Megohmmeter Test Probe

Safety Standards. Model Number:

DALI 650mA LED Driver

1100 Series Piston Type Differential Pressure Gauges

POWERWARE User s Guide VA.

EStrong-series Emergency Stop

Solenoid Operator 0513 / 1213

365 Detachable Jaw True-rms Clamp Meter

650mA Phase Dimmable LED Driver

- Wiring Brochure Universal Reset Module 422

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Mini Multimeter with Non-Contact Voltage Detector (NCV)

BMRX Series ROTARY LEVEL CONTROL

373 Clamp Meter. Users Manual

1000 Series Piston Type Differential Pressure Gauges

2-Year Limited Warranty. See the Users Manual for the full warranty.

- Wiring Brochure Zone Manager 335

362 Clamp Meter. Users Manual

1000mA - 650mA Phase Dimmable LED Driver

Model Fixed Rack-Mount Kit

- Wiring Brochure Zone Manager 336

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

80 Series V Digital Multimeter Safety Information

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

A419ABG-3C Electronic Temperature Control

INSTALLATION INSTRUCTIONS

Installation Instructions

CPC DX (CPC Dual Transfer Skid) Redundant current to pressure converter assembly

M-100 Adjustable flow switch with right-angle flow

323/324/325 Clamp Meter

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Electrical Installation

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

VA-7450 Series. Electric Valve Actuators

Load and Motor Switches, Load-Break Switches Series 8544

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Installation and Operating Manual

High Frequency SineWave Guardian TM

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Switching DC Power Supply

Tina 4A Connection block

MINI MCR-SL-UI-UI(-SP)(-NC)

FMC-1/2 Tina Muting unit

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

i400s Calibration Information Introduction

Sense7-series Non-contact coded safety switch

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

Load and Motor Switches, Load-Break Switches Series 8549

Fisher i2p 100 Electro Pneumatic Transducer

WF3132 User s Manual. AC rev D

Users Manual. Phase Rotation Indicator

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Tina 11A Connection block

Smile 41 Push-button box with/without emergency stop

Leica GKL341 User Manual. Version 1.0 EN

Transcription:

GETTING STARTED GUIDE NI 9472 8 DO, 6 V to 30 V, Sourcing, 100 μs

This document explains how to connect to the NI 9472. In this document, the NI 9472 with screw terminal, NI 9472 with spring terminal, and NI 9472 with DSUB are referred to inclusively as the NI 9472. Note Before you begin, complete the software and hardware installation procedures in your chassis documentation. Note The guidelines in this document are specific to the NI 9472. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system. Safety Guidelines Operate the NI 9472 only as described in this document. Caution Do not operate the NI 9472 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any 2 ni.com NI 9472 Getting Started Guide

way. If the product is damaged, return it to NI for repair. Hazardous Voltage This icon denotes a warning advising you to take precautions to avoid electrical shock with the NI 9472 with screw terminal and the NI 9472 with spring terminal. NI 9472 with Screw Terminal and Spring Terminal Safety Voltages Connect only voltages that are within the following limits. Channel-to- Isolation Channel-to-channel Channel-to-earth ground Continuous Withstand 30 VDC maximum None 250 Vrms, Measurement Category II 2,300 Vrms, verified by a 5 s dielectric withstand test NI 9472 Getting Started Guide National Instruments 3

Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe. Caution Do not connect the NI 9472 to signals or use for measurements within Measurement Categories III or IV. NI 9472 with DSUB Safety Voltages Connect only voltages that are within the following limits. Channel-to- Isolation Channel-to-channel Channel-to-earth ground Continuous Withstand 30 VDC maximum None 60 VDC, Measurement Category I 1,000 Vrms, verified by a 5 s dielectric withstand test 4 ni.com NI 9472 Getting Started Guide

Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. Caution Do not connect the NI 9472 to signals or use for measurements within Measurement Categories II, III, or IV. Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV. Safety Guidelines for Hazardous Voltages You can connect hazardous voltages only to the NI 9472 with screw terminal and the NI 9472 with spring terminal. Do not connect hazardous voltages to the NI 9472 with DSUB. NI 9472 Getting Started Guide National Instruments 5

If hazardous voltages are connected to the device, take the following precautions. A hazardous voltage is a voltage greater than 42.4 Vpk voltage or 60 VDC to earth ground. Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards. Caution Do not mix hazardous voltage circuits and human-accessible circuits on the same module. Caution Ensure that devices and circuits connected to the module are properly insulated from human contact. Caution When module terminals are hazardous voltage LIVE (>42.4 Vpk/60 VDC), you must ensure that devices and circuits connected to the module are properly insulated from human contact. You must use the NI 9927 connector backshell kit with the NI 9472 with screw terminal and the NI 9981 connector backshell kit with the NI 9472 with spring terminal to ensure that the terminals are not accessible. 6 ni.com NI 9472 Getting Started Guide

Safety Guidelines for Hazardous Locations The NI 9472 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx na IIC T4 and Ex na IIC T4 hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI 9472 in a potentially explosive environment. Not following these guidelines may result in serious injury or death. Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous. Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous. Caution Substitution of components may impair suitability for Class I, Division 2. Caution For Division 2 and Zone 2 applications, install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15. NI 9472 Getting Started Guide National Instruments 7

Caution For Division 2 and Zone 2 applications, install a protection device between the and terminals on the NI 9472. The device must prevent the input -to- voltage from exceeding 42 V if there is a transient overvoltage condition. Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9472 has been evaluated as Ex na IIC T4 Gc equipment under DEMKO Certificate No. 03 ATEX 0324020X and is IECEx UL 14.0089X certified. Each NI 9472 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 C Ta 70 C. If you are using the NI 9472 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nc IIC T4, Ex IIC T4, Ex na IIC T4, or Ex nl IIC T4 equipment. Caution You must make sure that transient disturbances do not exceed 140% of the rated voltage. Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC 60664-1. 8 ni.com NI 9472 Getting Started Guide

Caution The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15. Caution The enclosure must have a door or cover accessible only by the use of a tool. Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment. This product is intended for use in industrial locations. However, harmful interference may occur in some installations, when the product is connected to a peripheral device or test object, or if the product is used in residential or commercial areas. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. NI 9472 Getting Started Guide National Instruments 9

Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Special Conditions for Marine Applications Some products are Lloyd s Register (LR) Type Approved for marine (shipboard) applications. To verify Lloyd s Register certification for a product, visit ni.com/certification and search for the LR certificate, or look for the Lloyd s Register mark on the product. Caution In order to meet the EMC requirements for marine applications, install the product in a shielded enclosure with shielded and/or filtered power and input/output ports. In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. 10 ni.com NI 9472 Getting Started Guide

Preparing the Environment Ensure that the environment in which you are using the NI 9472 meets the following specifications. Operating temperature -40 C to 70 C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity (IEC 60068-2-78) Pollution Degree 2 Maximum altitude Indoor use only. 10% RH to 90% RH, noncondensing 2,000 m Note Refer to the device datasheet on ni.com/manuals for complete specifications. NI 9472 Getting Started Guide National Instruments 11

NI 9472 Pinout DO0 DO1 DO2 DO3 DO4 DO5 DO6 DO7 0 1 2 3 4 5 6 7 8 9 DO0 DO1 DO2 DO3 DO4 DO5 DO6 DO7 0 1 2 3 4 5 6 7 8 9 DO0 DO1 DO2 DO3 DO4 DO5 DO6 DO7 14 1 15 2 16 3 17 4 18 5 19 6 20 7 21 8 22 9 23 10 24 11 25 12 13 12 ni.com NI 9472 Getting Started Guide

Note You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9472 with screw terminal or NI 9472 with spring terminal. Table 1. NI 9472 Signal Descriptions Signal DO Description Common reference connection to isolated ground Digital output signal connection Voltage supply connection Table 2. LED Indicators LED Pattern Solid Off Indication The channel has been programmed to be in the ON state. The channel has been programmed to be in the OFF state. NI 9472 Getting Started Guide National Instruments 13

Connecting Digital Devices You can connect a variety of industrial devices, such as solenoids, motors, actuators, relays, and lamps to the NI 9472. You must connect an external power supply to the NI 9472. The power supply provides the current for the output channels. Figure 1. Connecting an Industrial Device to the NI 9472 V sup DO Device + External Power Supply NI 9472 Caution Do not install or remove C Series modules from your system if the external power supply connected to the and pins is powered on. 14 ni.com NI 9472 Getting Started Guide

Ensure that the devices you connect to the NI 9472 are compatible with the output specifications of the NI 9472. Refer to the device datasheet at ni.com/manuals for output specifications. Note When the industrial device is off, DO is not connected to. For large source impedances, you must use a pull-down resistor between DO and. Visit ni.com/info and enter the Info Code CSeriesDOPulseGen for more information. Increasing Current Drive Each channel of the NI 9472 has a continuous output current of 0.75 A. If you want to increase the output current to a device, you can connect any number of channels together in parallel. For example, if you want to drive 3 A of current, connect DO0 through DO3 in parallel, as shown in the following figure. You must turn all parallel channels on and off simultaneously so that the current on any single channel cannot exceed the 0.75 A rating. NI 9472 Getting Started Guide National Instruments 15

Figure 2. Increasing the Current to a Device Connected to the NI 9472 NI 9472 DO0 DO1 DO2 DO3 0.75 A 0.75 A 0.75 A 0.75 A Device 3 A + External Power Supply High-Vibration Application Connections If your application is subject to high vibration, NI recommends that you follow these guidelines to protect connections to the NI 9472: Use ferrules to terminate wires to the detachable connector. Use the NI 9927 backshell kit with the NI 9472 with screw terminal or the NI 9981 backshell kit with the NI 9472 with spring terminal. 16 ni.com NI 9472 Getting Started Guide

I/O Protection The NI 9472 provides short-circuit protection. Each channel has circuitry that protects it from current surges resulting from short circuits over 14 A. Note Refer to the device datasheet at ni.com/manuals for maximum continous output current, short-circuit behavior, and short-circuit trip time specifications and information about conditions that may damage the module. Note Refer to the IEC 61131-2 standard for more information about short-circuit-proof devices. Note Because the NI 9472 includes internal flyback diodes, you do not need to add external diodes when connecting to switching devices that store energy. NI 9472 Getting Started Guide National Instruments 17

Power Supplies and Overcurrent Conditions If a short circuit occurs, the current through DO can exceed the current rating for the power supply and the maximum continuous output current for the NI 9472. If the power supply you are using with the NI 9472 cannot supply more than 14 A, the module may be damaged if a short circuit condition occurs. Detecting an Overcurrent Condition If a device connected to the module is not working while the channel is on, the module channel may be in an overcurrent state. Neither the software nor the module LEDs indicate if an overcurrent condition occurs. A channel LED may be on even if the channel is off because of an overcurrent condition. To determine if the channel is in an overcurrent state, measure the voltage between DO and. If the voltage is equal to the voltage of the external power supply connected to the module, the channel is in an overcurrent state. 18 ni.com NI 9472 Getting Started Guide

Resetting Channels after an Overcurrent Condition After you have determined and fixed the cause of an overcurrent condition, reset the channel by turning it off. Alternatively, you can disconnect the external power supply from the chassis. However, doing so disconnects power from all the module channels. Normal operation can resume after you correct the overcurrent condition and reset the channel. NI 9472 Getting Started Guide National Instruments 19

Where to Go Next CompactRIO NI CompactDAQ NI 9472 Datasheet NI-RIO Help LabVIEW FPGA Help NI 9472 Datasheet NI-DAQmx Help LabVIEW Help RELATED INFORMATION C Series Documentation & Resources ni.com/info cseriesdoc Services ni.com/services Located at ni.com/manuals 20 ni.com NI 9472 Getting Started Guide Installs with the software

Worldwide Support and Services The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers. Visit ni.com/services for NI Factory Installation Services, repairs, extended warranty, and other services. Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI. A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. NI 9472 Getting Started Guide National Instruments 21

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/ export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2003 2016 National Instruments. All rights reserved. 373509H-01 Mar16