INSTALLATION MANUAL. Model: PLUS Vehicle Security

Similar documents
INSTALLATION MANUAL. Remote Mobile Security System. Model: PL50

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 INSTALL 1

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer.

6R / 5-BUTTON SERIES VEHICLE SECURITY SYSTEM

OCT/21/02 MEGA 670L DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

MM1 Installation Instructions

Model APS-101N Installation Manual

KE 680 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM DOOR LOCK RELAYS ON-BOARD. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

ALARM UPGRADE FOR FACTORY REMOTE KEYLESS ENTRY SYSTEM INSTALLATION PRECAUTIONS & WARNINGS

Security and Keyless Entry Installation Guide ca 1051

Remote Start with Keyless Entry Installation Guide ca5054

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

DLKEK3HN INSTALLATION INSTRUCTIONS

2 Way Security and Keyless Entry Installation Guide ca 1553

RF-425LCD PROFESSIONAL VEHICLE SECURITY SYSTEM INSTALLATION MANUAL (FOR AUTHORIZED DEALERS ONLY)

Manual - Inside Front Cover (Blank)

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

INSTALLATION GUIDE. FCC ID NOTICE

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide for models: ca5153 ca5153sst

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

Remote Start with Keyless Entry Installation Guide CA 5051

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer.

VS 315 DELUXE 4-CHANNEL MOTORCYCLE ALARM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 315 1

Vehicle Security System

FOR AUTOMATIC TRANSMISSION AND DIESEL ENGINE VEHICLES

CA-110 Installation Instructions

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

FM SECURITY AND REMOTE START SYSTEM

VS 655 DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 655 1

Security and Remote Start Installation Guide for models: ca6554

CP 634 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM

FEB.20, 2003 COMMANDO MODEL FM-870 REMOTE ENGINE STARTER WITH ALARM SYSTEM INSTALLATION MANUAL RST872 1

Diablo 2 /AMX 68/AT-58 Installation Manual 3/31/99

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

Vehicle Security System

Security and Remote Start Installation Guide for models: ca 6552 ca 6552 SST

FEB/20/2003 COMMANDO EZ-2500 REMOTE ENGINE STARTER WITH KEYLESS ENTRY SYSTEM INSTALLATION MANUAL 550A 1

Model AX-510 Owner s Manual

MEGA WAY LCD REMOTE ENGINE STARTER AND CAR ALARM SECURITY. Installation Manual MEGATRONIX CALIFORNIA, U.S.A. MEGA 2700 INSTALL 1

"WE'VE GOT THE EDGE ON SECURITY" INSTALLATION MANUAL AL-700 ATV / AL-900 ATV / AL-1000 ATV

CS-2001 REMOTE CONTROL ALARM SYSTEM INSTALLATION & OPERATING INSTRUCTIONS INTRODUCTION

Vehicle Alarm System With Channel 2 Auxiliary Output Installation Instructions

Security and Remote Start Installation Guide for models: ca6553 ca6553sst

REC-11+ REMOTE RECEIVER UNIT

AUTOMATIC TRANSMISSION ONLY! Technical Support: ext 1 Warning!!

IN VEHICLE SECURITY ULTIMATE FLEXIBILITY. Installation Supplement. ClassicOne & UltraOne

Automatic / Manual Transmission Remote Start with Keyless Entry Installation Guide. ca 5152

INSTALLATION MANUAL 601-S INFORMATION.) 8. REMOVE DOME LIGHT FUSE TO PRE- VENT BATTERY DRAIN.

12V PROGRAMMABLE POWER OUT

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1

Vehicle Security System

FS-22 and FS-32 KEYLESS ENTRY and ALARM SYSTEM INSTALLATION INSTRUCTIONS

CSI-300 Installation Instructions

K9-Mundial-2. ver. a color cover. Owner's Guide & Installation Instructions. MA_K9-Mundial-2/REV0 4/01 COPYRIGHT: OMEGA RESEARCH & DEVELOPMENT 2001

Remote Keyless Entry Installation Guide ca 2051

Table of Contents. Owner s Guide

6 RELAY SYSTEM 5-BUTTON SERIES VEHICLE SECURITY SYSTEM INSTALLATION MANUAL

RA2 Installation Manual Rev. B

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 OPERATE 1

Model PRO-9775T Owner's Manual 4 Button Remote Start Security System With Plug-In Shock Sensor & Starter Disable

Model CSI-300 Owner s Manual

VS CHANNEL REMOTE ENGINE STARTER WITH KEYLESS ENTRY. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 OPERATE 1

INSTALLATION MANUAL MODEL: K9-FIVE ATV L I M I T E D L I F E T I M E W A R R A N T Y

AS-4000 OPERATING INSTRUCTIONS (PS-5000)

REMOTE CONTROL ALARM SYSTEM INSTALLATION & OPERATING INSTRUCTIONS INTRODUCTION

Model PRO 9233N OWNER S MANUAL

VEHICLE SECURITY SYSTEM INSTALLATION MANUAL

INSTALLATION GUIDE OWNER S GUIDE

DLRM DLRM

Covers All 35xx Series Advanced 2-Way Remote Starters. Technical Support: ext 0

EXTENDED INSTALL GUIDE Revision /2015 FW 51+

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer.

CA-210 Installation Instructions

CS-2000 Series III REMOTE CONTROL ALARM SYSTEM INSTALLATION & OPERATING INSTRUCTIONS

" MANUALLY OVERRIDING YOUR SYSTEM

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Model AS-9234E. Owners Guides

VS CHANNEL REMOTE ENGINE STARTER WITH KEYLESS ENTRY. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

INSTALLATION MANUAL. 745i 2 COPYRIGHT 1997: CRIME GUARD KEYLESS ENTRY & SECURITY

CS-2001FC Series II REMOTE CONTROL ALARM SYSTEM INSTALLATION & OPERATING INSTRUCTIONS INTRODUCTION

Model APS-510C Installation Manual Remote Control Vehicle Security System

CS-2002DC & CS-2002DC Series II

INTRODUCTION ALARM WIRING DESCRITION

CS-2000 Series III REMOTE CONTROL ALARM SYSTEM INSTALLATION & OPERATING INSTRUCTIONS INTRODUCTION

INSTALLATION GUIDE Table of Contents

INSTALLATION INSTRUCTIONS

CS-2002DPII With Data Port Technology

Remote Start Installation Guide ca 4552

Advanced Remote Vehicle Starting System

Model: APS-610a Owner s Manual 4 Button Remote Security System with Dual Stage Shock Sensor

PROFESSIONAL REMOTE ALARM SYSTEM INSTALLATION MANUAL

INSTALLATION MANUAL. 328i 2 COPYRIGHT1997:CRIMEGUARDKEYLESSENTRY &SECURITY

Press and release the valet switch 3 times 1 Chirp - LED 1 flash

CA-510a Installation Instructions

Model PRO 9649 Owner s Manual

Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED. Installation Precautions:

Transcription:

R Vehicle Security INSTALLATION MANUAL Model: PLUS-5000 Copyright 1999 Magnadyne Corporation For Technical Assistance (800) 638-3600 For Fax on Demand Technical Assistance (800) 994-9977 (Must be a Registered Dealer to Use Fax on Demand System)

Index Step 1: Component Installation................................................ 2-3 Step 2: 10-Pin Main Harness Installation......................................... 3-4 Step 3: 5-Pin Power Harness Installation........................................ 4-5 Step 4: DIP Switch Programming............................................... 5 Step 5: Optional Accessory Connections....................................... 6-11 Step 6: Transmitter Programming.......................................... 12-13 Step 7: Remote Feature Programming........................................ 14-15 Step 8: Multiple Car Programming............................................ 16 Step 9: General Testing.................................................... 16 Step 10: Speciality Feature and Optional Equipment Testing........................ 16-19 Specifications........................................................... 19 Wiring Diagram.......................................................... 20 Warning! Do not plug the 10-pin or 5-pin wire harness into the alarm control module before you begin installing the alarm. The wire harnesses must be plugged into the alarm control module after all connections are made. Failure to follow this procedure could cause some confusion with transmitter operation and or alarm function operation. The PLUS-5000 security system ia packaged 3 different ways for maximum flexibility. Even though the system is packaged 3 different ways they all contain the same module and installation harnesses. The following is how each model number is packaged: PLUS-5000: 5000 Alarm Module with no transmitters and no siren. PLUS-5000S: 5000 Alarm Module with (2) standard 2-button transmitters and a siren. PLUS-5000C: 5000 Alarm Module with (2) 4-button code-hopping transmitters and a siren. Step 1: Component Installation Mounting the Control Module: Find a suitable location to secure the alarm control module within the passengers compartment of the vehicle. Never mount the alarm control module in the engine compartment or in the trunk. In addition, never mount the alarm control module in the direct path of the heater. Secure the alarm control module by using wire ties or drill two 1/8 holes and secure the module to the frame of the vehicle with the screws provided. Mounting the Siren: (Option on PLUS-5000 Packaging) Find a suitable location in the engine compartment to secure the siren. Select a location that provides a direct sound path to the ground for maximum siren output. Use the self tapping screws provided and secure the siren. Connect the black wire coming from the siren to the frame of the vehicle. In many cases, you can ground the black wire to one of the screws used to secure the siren. Run the remaining brown wire through the fire wall to the location of the alarm control module. Installing Hood/ Trunk Pin Switches: Provided with the alarm kit is one pin switch and one mounting bracket. To install the switch either in the truck or under the hood, find a suitable location where the switch will make contact with the hood or trunk lid and will not get wet. Use the bracket provided or drill a 1/4 hole in the desired location. 2

Step 1: Component Installation (Continued) Mounting the LED/Valet Switch Holder: Their are two options for mounting this item. 1. The LED can be removed from the holder and mounted in a separate location. The holder would then be mounted with the valet switch socket facing the driver. 2. The holder can be mounted with the LED facing the driver and the valet switch socket will face the fire wall. Select a suitable location for the holder where it will not obstruct the normal operation of the vehicle. Use the holder as a template and drill two 1/8 holes. Secure the holder to it s mounting location with two screws. Installing the Alarm Status LED: (Only Applies if LED is Not Located in the LED/Valet Switch Holder) Find a suitable location for the LED and drill a 5/16 hole in the desired location. Feed the 2-pin plug through the hole and press the body of the LED into place. Run the LED wires to the location of the alarm control module. Step 2: 10-Pin Main Harness Installation The main wire harness contains 8 wires which all have a specific purpose. Follow the wiring recommendations enclosed for each wire. Wires not used should be released from the harness connector or taped off to prevent accidental shorting. Included with the 10-pin wire harness are two loose wires, an orange wire and a white wire with black stripe. See main harness and power harness wiring instructions for these two loose wires. Main Harness Vacant Sockets First Vacant Socket (Located in the 1st Position) Second Vacant Socket (Located in the 8th Position) First Vacant Socket: (For Use with ALA-RPT Relay Pack Only) See Optional Accessory Connection for proper wiring. (Page 10-11) Gray Wire: (Pulsed Ground for Car Horn) The gray wire is a pulsed ground output designed to activate the vehicle s existing car horn system in place of or in addition to a siren sounding device. Connect the gray wire to the negative trigger wire on the vehicle s horn relay. WARNING! Maximum output of this wire is 0mA. Horn systems requiring positive voltage or more than 0mA to trigger the horn relay will require an additional relay to increase current capabilities. Blue Wire with White Stripe: (Channel #3 Output) Connect the blue/white wire to the device that will be operated from channel #3 of the alarm system. The blue/white wire has a current capacity of 0mA maximum. This output is activated by pressing down button #3 and holding it. The blue/white wire will provide a grounded signal as long as button #3 on the transmitter is held down. 3

Step 2: 10-Pin Main Harness Installation (Continued) Brown Wire: (Siren + Output) Connect the brown wire to the positive wire from the siren. Ground the remaining wire from the siren for proper operation. Blue Wire: (Optional Grounding Sensor Input) The blue wire is an instant grounding trigger input for optional hood/trunk grounded pin switches or any electronic sensor. Green Wire: (Grounded Door Pin Switch Input) The green wire connects to the common wire of the vehicle that switches on the dome light. Normally this wire is located at one of the door jamb switches. For some vehicles it may be necessary to connect the green wire directly to the switched turn on wire at the dome light. The green wire connects to negative switched circuits only. Violet Wire: (Positive Door Pin Switch Input) The violet wire connects to the common wire of the vehicle that switches on the dome light. Normally this wire is located at one of the door jamb switches. For some vehicles it may be necessary to connect the violet wire directly to the switched turn on wire at the dome light. The violet wire connects to positive switched circuits only. Second Vacant Socket: The second vacant wire socket provides a 1 second pulsed ground (0mA) output when channel #2 is activated. (See Optional Accessory Connections) (Page 10-11) Red / White: (Pulsed Parking Light Relay Output) Connect the red/white wire to the parking light wire coming from the headlight switch. (Do not connect the red/white wire to the dashboard lighting dimmer switch. Damage to the dimmer will result) use a volt meter to test the connection point before connecting the red/white wire. While checking, rotate the dimmer switch to make sure you do not have the dimmer lead. The limitation of the red/white wire is 10 Amp max. Do not exceed this limit or damage to the alarm and parking light relay will result. Pink: (Parking Light Relay Input) The pink wire is the input to the flashing parking light relay. The connection of the pink wire will determine the output polarity of the flashing parking light relay. Connect the pink wire to (+) battery to have (+) output from the relay or connect the pink wire to frame ground to have ground output from the relay. Step 3: 5-Pin Power Harness Installation The power harness contains 3 wires and two vacant sockets. Follow the wiring recommendations enclosed for each wire. Power Harness 4 First Socket Second Socket

Step 3: 5-Pin Power Harness Installation (Continued) First Vacant Socket: The first vacant wire socket is a low current (0mA) grounded output wire that can be used to activate the vehicle s interior lighting system when the security system is disarmed. An additional relay is required for proper installation. See Optional Accessory Connection for proper wiring. (Page 10-11) Second Vacant Socket: See Optional Accessory Connection for proper wiring. (Page10-11) Red Wire: (Main Power Input) Connect the red wire directly to the (+) battery post for best operation of the alarm system. For best current sensing capability from the alarm s current sensing circuit, connect the red wire to the constant power wire coming from the interior dome light. Black Wire: (Main Ground Input) Connect the black wire directly to the frame of the vehicle. Use a bolt and nut to secure the wire. Scrape away any grease or paint that might prevent a good connection. Yellow Wire: (Switched +12 Volts From the Ignition Switch) Connect the yellow wire to a +12 volt wire that is switched on and off by the ignition key. The correct wire will indicate +12 volts when the ignition key is in the on and start positions. Do not connect the yellow wire to the acc wire coming from the ignition switch. Step 4: DIP Switch Programming Switch #1: Power Door Lock Output Timing Set switch #1 to the on position for a.8 second duration output (Common setting for all Japanese and American vehicles) Set switch #1 to the off position for a 3.5 second duration output (European vacuum locking system only) Switch #2: Passive Arm Locking Control Set switch #2 to the on position to allow the door locks to lock when the alarm automatically arms. Set switch #2 to the off position to prevent the door locks from locking when the alarm automatically arms. Switch #3: Current Sensing ON/OFF Set switch #3 to the on position to activate the current sensing trigger circuit. Set switch #3 to the off position to eliminate the current sensing trigger circuit. Switch #4: Safety Illumination Sentinel System (SISS) On/Off Set switch #4 to the on position and the parking lights will remain on for 12 seconds after the alarm is armed by the remote control. The parking lights will also remain on for seconds after the alarm is disarmed by the remote control. Turning on the ignition key will turn off the lights before the seconds expires. Set switch #4 to the off position for this feature to be off. 5

Step 5: Optional Accessory Connections Power Door Lock / Unlock Activation 3 Wire Positive Trigger Door Lock System Lock Control Switch (+) Lock Out +12 Volts Input (+) Unlock Out Black Wire: Connect to Lock Orange Wire: No Connection Red Wire: Connect to Unlock 3 Pin Black Plug To Alarm To Door Lock Control Relays Note: Prewired Door Lock Interconnect T-Harness are Available for Most Vehicles 3 Wire Ground Trigger Door Lock System Black Wire: Connect to Unlock Lock Control Switch (-) Lock Out Ground Input (-) Unlock Out Orange Wire: No Connection Red Wire: Connect to Lock 3 Pin Black Plug To Alarm To Door Lock Control Relays Note: Prewired Door Lock Interconnect T-Harness are Available for Most Vehicles 5 Wire Ground at Rest Door Locking Systems Red Wire: Lock 3 Pin Black Plug Orange Wire: No Connection Black Wire: Unlock ALA-DL1 Relay Pack A A Violet Wire White Wire: Lock Brown Wire: Unlock Green Wire: Lock Blue Wire: Unlock To +12 Volts (Battery +) To Power Lock Switch To Power Lock Motors Note: Prewired Door Lock Interconnect T-Harness are Available for Most Vehicles 6

Step 5: Optional Accessory Connections (Continued) Mercedes Door Lock Activation Red Wire: Lock 3 Pin Black Plug Orange Wire: No Connection Black Wire: Unlock -- Lock A + + + A Unlock Cut Green Wire B+ Unlock Door Lock Switch Lock To +12 Volts (Battery +) Door Lock Compressor Newly Installed Power Door Lock Motors Red Wire: Lock Orange Wire: No Connection Black Wire: Unlock 3 Pin Black Plug ALA-DL1 Relay Pack A A Violet Wire White Wire Brown Wire Green Wire: Lock Blue Wire: Unlock To +12 Volts (Battery +) To Ground To Newly Installed Power Door Lock Motors One Wire Multiplexing Door Locking Systems Some vehicle s (Chrysler, Mazda and Ford Probe and others) use one wire to lock and unlock the doors. Example: When the door lock controller sees a signal thru a resistor it will unlock. If a signal is received without a resistor the doors will lock. Some use 2 resistors. One for lock and one for unlock. We have developed patented plug-in fuse resistors for this application. Simply remove the fuse from our door lock module and replace with correct resistor value fuses that matches the vehicles door lock switch. ALA-DL1 Wiring: 1. Connect both the green (lock) and the blue (unlock) wires to the vehicles one wire lock/unlock wire. 2. Connect our violet polarity input wire to +12v or to ground. To match vehicles door lock polarity 3. The white and the brown wires will not be used. 7

Step 5: Optional Accessory Connections (Continued) Unlock Driver's Door First for 3-Wire Negative Door Lock Systems Red Wire Lock All Doors Black Wire Unlock Drivers Door Must Add ALA984H Relay Drivers Door Switch Orange Wire Unlock Remaining Doors Lock A +12V Passenger Door Switch Driver's Door Unlock To +12V or Ground Unlock Wire Cut Lock Unlock Door Lock Relay Control Module To +12V or Ground Passenger's Door Rear Door Unlock Driver's Door First Wiring for 3-Wire Positive Door Lock System Red Wire Orange Wire Black Wire To +12 Volts (Battery +) A Driver's Door Motor + Unlock Cut A A Lock Unlock To Power Door Lock Switch Lock/Unlock Wires 8

Step 5: Optional Accessory Connections (Continued) Unlock Driver's Door First Wiring for 5-Wire Ground at Rest Door Locking Systems Red Wire Orange Wire Black Wire To +12 Volts (Battery +) Driver's Door Motor + Unlock A Cut A A Lock Unlock Lock Unlock To Power Lock Switch To Power Lock Motors Starter Disable Wiring Using the wiring information and diagram below, connect the 2-pin white starter disable plug as follows: A. Cut the ignition switch (Starter Wire). B. Connect the ignition switch side of the cut "start only" wire to one of the black wire from the 2-pin plug. C. Connect the remaining "start only" wire to the other black wire from the 2-pin plug. To test the starter disable system refer to the starter disable testing procedures located in the testing section of this manual. (Page 16) 2-Pin Plug from Control Module "ACC" "OFF" "ON" "START" Cut Starter Interrupting Other Circuits Orange 2-Pin "ACC" "OFF" Red Wire Black Wire Interrupt One Circuit Use ALA-RPS "ON" Black Wire "START" a 86 85 CUT Black Wire White Wire a 86 85 CUT White Wire IInterrupt Two Circuits Use ALA-RPS2 Power Supply to Fuel Pump or Power Supply to Fuel Injectors Power Supply to ECM or Power Supply to Ignition Coil 9

Step 5: Optional Accessory Connections (Continued) Flashing Parking Lights Headlight Switch Red Wire with White Stripe Output from Alarm Piggyback Connection Parking Lights Only Alarm Status LED and LED/Valet Switch Holder LED Harness 2-Pin (White) Plug-In LED Valet Switch 2-Pin (Blue) LED/Valet Switch Holder Dual Zone Electronic Sensor Plug: (Applies to PLUS-4000 Only) Red Wire: +12 Volt Sensor Power Supply Black Wire: Sensor Ground Supply Blue Wire: Sensor Alarm Trigger Output Green Wire: Sensor Pre-Warning Output 4 Pin White Plug Optional Dome Light Illumination and Lighted Pathway Illumination Purple Wire Black Wire ALA-RPT2 Red Wire Relay Pack Orange Wire Output to Domelight (+ or - ) Input to Relay (+ or - ) White/Purple Wire White/Orange Wire Headlight Switch Input to Relay (+ or - ) Low Beam Headlights Warning! Piggyback connections to Lowbeam Headlights or Parking Lights (one or the other but not both) or Parking Lights 10

Step 5: Optional Accessory Connections (Continued) Dome Light Supervision Using Optional ALA-RPT Relay Pack: Insert Black Wire into the First Socket Insert Red Wire into the Second Socket Black Wire Red Wire ALA-RPT Relay Pack Orange Wire Output to Dome Light (+ or -) Purple Wire Input to Relay (+ or -) Dome Light Supervision Using Optional Amp Relay: Insert Orange Wire into the First Socket Orange Wire (SPST ALA984H Relay Not Supplied) 86 85 Output to Dome Light (+ or -) To Constant +12 Volts Input to Relay (+ or -) #2 Button Power Trunk Activation Using Optional ALA-RPT Relay Pack Insert Red Wire into the First Socket Insert Black Wire into the Eighth Socket Black Wire Red Wire ALA-RPT Relay Pack Orange Wire Output to Trunk Switch Purple Wire Input to Relay (+ or -) #2 Button Power Trunk Activation Using Optional Amp Relay Insert White Wire with Black Stripe into the Eighth Socket White Wire with Black Stripe Output to Power Trunk Switch To Constant +12 Volts (SPST ALA984H Relay Not Supplied) 86 85 Input to Relay (+ or -) 11

Step 6: Transmitter Programming Step 1 Step 2 Note shape of housing. Insert the Valet Switch and Make Sure the Valet/Override Switch is in the Off Position "Off" Positon "On" Positon Plug In the Power Harness The siren/horn will start sounding, the parking lights will flash and the LED will begin flashing Step 3 Step 4 Step 5 ON 2x 4x Turn On Ignition Push the Valet Switch 2 Times (Represent 1 Time On/Off) The siren/horn will stop sounding, the parking lights will stop flashing and the LED will be solid red. Push the Valet Switch 4 Times (Represent 2 Times On/Off) The siren/horn will chirp 1 time. You are now in the transmitter code programming mode. 12

R R R Step 6: Transmitter Programming (Continued) Step 6 Regular Arm/Dis #2 R Regular Arm/Dis #2 Regular Arm/Dis #2 Regular Arm/Dis #2 #3 Code Hopping LOCK PANIC UNLOCK AUX Push Arm/Disarm (Regular) or Lock Button (Code Hopping) The LED will begin flashing slowly and the horn/siren will emit 1 short chirp. The code has now been learned. Note 1: Regular transmitters supplied are Not coded alike so you need to code in the second transmitter now by pushing the Arm/Dis button on the second transmitter. Go to Step 7. Note 2: Code Hopping transmitters supplied are Not coded alike so you need to code in the second transmitter now by pushing the Lock button on the second transmitter. Note 3: If you are coding a Code Hopping transmitters, skip steps 7, 8, 9 and 10 and go to step 11. No further coding procedures are necessary. Code hopping transmitters learn all button functions when the Lock button is learned. Step 7 2x To Code #2 Button Push the Valet Switch 2 Times (Represent 1 Time On/Off) The LED will be solid red and the horn/siren will chirp 1 time. Step 8 Push the #2 Button The LED will begin flashing slowly and the horn/siren will chirp 2 times. Note 1: Regular transmitters supplied are Not coded alike so you need to code in the second transmitter now by pushing the #2 button on the second transmitter. Step 9 Step 10 Step 11 2x To Code #3 Button Push the Valet Switch 2 Times (Represent 1 Time On/Off) The LED will be solid red and the horn/siren will chirp 1 time. Push the #3 Button The LED will begin flashing slowly and the horn/siren will chirp 3 times. Note 1: Regular transmitters supplied are Not coded alike so you need to code in the second transmitter now by pushing the #3 button on the second transmitter. OFF Turn Off the Ignition The horn/siren will emit 1 short chirp and 1 long chirp. You are now out of the consumer transmitter code learning mode. The LED is off. 13

Step 7: Remote Feature Programming When the Carbine security system control module learns the transmitter operating code, a specific group of operating features are automatically programmed to a default setting. These default settings can be changed by following the enclosed procedure and using the consumer transmitter for programming. # Programmable Alarm Feature Default Setting 1 Chirp Status Indicator On 2 Last Door Closed Automatic Arming Automatic Arming of Alarm Off 3 Ignition Key Controlled Door Lock/ Unlock Off 4A #3 Button (Channel 3 or Panic Operation) Channel #3 (3-Button Regular Transmitter Only) 4B Panic Button (Panic or Channel 3 Operation) Panic (4-Button Code Hopping Transmitter Only) Step 1 Note shape of housing. Step 2 R Insert the Valet Switch and Make Sure the Valet/Override Switch is in the Off Position "Off" Positon "On" Positon Disarm the Security System The LED will be off and the horn/siren will emit 2 chirps The LED will remain off. Step 3 ON Turn On the Ignition Step 4 Push the Valet Switch 12 Times (Represent 6 Times On/Off) The LED will be on solid and the horn/siren will emit 1 long then 1 short chirp. You are now in the Remote Feature Programming mode. 12x 14

R R Step 7: Remote Feature Programming (Continued) Regular Arm/Dis #2 Regular Arm/Dis Step 5 #2 Regular Arm/Dis #2 Regular Arm/Dis #2 Code Hopping LOCK UNLOCK #3 PANIC AUX # Transmitter Button Function Confirmation = Change Function 1 ARM/DIS or LOCK Chirp Status Indication 1 Beep = Chirp Status Indication On * 2 Beeps = Chirp Status Indication Off 2 #2 or UNLOCK Last Door Closed 1 Beep = Automatic Arming On, Alarm will arm 10 seconds after Automatic Arming door is closed and rearm 10 seconds after remote disarm. 2 Beeps = Automatic Arming On, Alarm will arm 20 seconds after door is closed and rearm 20 seconds after remote disarm. 3 Beeps = Automatic Arming On, Alarm will arm seconds after door is closed and rearm 60 seconds after remote disarm. 4 Beeps = Automatic Arming Off * 3 ARM/DIS + #2 Ignition Key Controlled 1 Beep = Door will Lock 3 seconds after Ignition is Turned On. or Door Locks Door will not Unlock when Ignition is Turned Off. LOCK + UNLOCK 2 Beeps = Door will Lock 3 seconds after Ignition is Turned On Door will Unlock when Ignition is Turned Off. 3 Beeps = Door will not Lock 3 seconds after Ignition is Turned On. Door will not Unlock when Ignition is Turned Off *. 4A #3 Channel 3 Operation or 3 Beeps = Button #3 Operates as a Dedicated Panic Button 3-Button Regular Panic Operation from 4 Beeps = Button #3 Operates Channel 3 Output of Alarm * Transmitter Only # 3 Transmitter Button 4B Panic Panic Operation or 3 Beeps = Panic Button Operates Channel #3 Output of Alarm 4-Button Channel #3 Operation 4 Beeps = Panic Button Operates as a Dedicated Panic Button * Code Hopping from Panic Transmitter Transmitter Only Button * Indicates Default Settings Step 6 OFF Turn Off the Ignition The horn/siren will emit 1 short chirp and 1 long chirp. You are now out of the Remote Feature Programming mode. The LED is off. 15

Step 8: Multiple Car Programming About Multiple Car Programming: Note 1: Regular Carbine transmitters with 2 buttons can operate 2 Carbine alarm systems. (Alarm models do not have to be the same) Note 2: Regular Carbine transmitters with 3 buttons can operate 3 Carbine alarm systems. (Alarm models do not have to be the same) Note 3: Code Hopping Carbine transmitters will only operate 1 Carbine alarm system. To perform multi-car programming, all transmitters must first be marked car to indicate which car/alarm they are for. ie car #1, car #2 etc. Once this is done, follow the specific programming procedure for each model alarm you are programming and program the arm/disarm button, Channel #2, and Channel #3 buttons according which car they will operate. Step 9: General Testing To test the basic functions of the alarm system (all models) repeat the following procedures. 1. Turn off the ignition key and exit the vehicle closing all protected entrances. 2. Press the arm/disarm or lock button on the transmitter. You will hear a siren/horn chirp, the parking lights will flash one time and the LED status indicator will flash at normal speed. 3. Wait 5 seconds, then open a protected entrance. The siren/horn will begin to sound. Press the arm/disarm or unlock button once again and the siren/horn will stop sounding. (No Disarm Chirp Indicator) Note: If you disarm the alarm when the siren/horn is sounding, there are no disarming chirps. When you disarm the alarm when the siren is off, there will be disarming chirps. 4. Follow procedures 2 and 3 for all other protected entrances. Step 10: Speciality Feature and Optional Equipment Testing Each specialty feature listed operates in the same manner regardless of the alarm model. Test each feature by following the procedures enclosed to insure proper operation. Remote Panic: 1. Press and hold the arm/disarm (for regular transmitters) or panic button (for code hopping transmitters) down for approximately 3 seconds. 2. The alarm will begin to sound and the parking lights will begin to flash. 3. Press the arm/disarm or panic button once again and the siren/horn will stop sounding and the lights will stop flashing. Note 1: The remote panic feature has an automatic shut off circuit. When the siren/horn has sounded for 60 seconds, the panic circuit will turn itself off automatically. Note 2: The remote panic feature can be programmed to operate exclusively from #3 button on a 3- button transmitter. (See Remote Feature Programming). Note 3: The panic button on a 4-button code hopping transmitter can be programmed to operate as the channel 3 button and not a panic button. (See Remote Feature Programming) Pressing and holding down the lock button on a 4-button transmitter will always activate the panic feature. Starter Disable: (Also Applies if ALA-RPS2 was Installed to Interrupt Other Circuits) 1. Enter the vehicle and close all the entrances. 2. Arm the alarm using the transmitter. 3. Turn the ignition key to the start position. The engine will not crank over. 4. Turn the ignition key to the off position and disarm the alarm. 5. Turn the ignition key back to the start position and the engine will crank over and start. 16

Step 10: Speciality Feature and Optional Equipment Testing Override Operation: (Security System is Armed) 1. Enter the vehicle and the security systems will begin sounding at this point. Insert the valet switch into the holder and make sure that the valet/override switch is in the off position 2. Place the ignition key into the ignition switch and turn the ignition switch to the on position. 3. Within 5 seconds of turning the ignition key on, place the valet switch to the on position. 4. The horn/siren will stop sounding. 5. The LED indicator will be solid red. The security system is overridden and is now in the valet mode! Note 1: If the valet switch is already in the on position when you turn on the ignition key, the override function will be bypassed. Turn off the ignition key, place the valet switch in the off position and try again. Note 2: If you fail to place the valet switch to the on position within 5 seconds of turning on the ignition key, the override function will be locked out. Place the valet switch in the off position, turn off the ignition key and try again. Valet Operation: (The security system is already disarmed) 1. Insert the valet switch into the holder and make sure that the valet switch is in the off position. 2. Turn the ignition key to the on position 3. Place the valet switch to the on position. 4a. The LED will be on solid indicating that the security system is in the valet mode. (Ignition is on). 4b. The LED will flash one every 5 seconds to indicate valet mode when the ignition is off. How to Get Back to Security System Activation Mode: 1. Place the ignition key switch to the on position. 2. Place the valet switch to the off position. 3. Place the ignition key switch back to the off position. You will notice that the LED indicator will be off. This indicates that you have exited the valet mode and your security system will operate normally. 4. Remove the valet switch. Last Door Automatic Arming: (If Programmed On) Note: The automatic arming feature will not operate unless the alarm input triggers have been connected directly to the existing or newly installed door jamb pins. Current sensing alone will not activate the automatic arming circuit. 1. Disarm the alarm. 2. Set the ignition key to the on position, then turn it off. 3. Exit the vehicle. The siren/horn will chirp 1 time when the door is closed. 4. The LED will begin to flash fast. 5. After 10, 20 or seconds have passed (depending on remote feature programming), you will hear a single chirp. The alarm is now armed. 6. The LED will flash at a regular rate indicating an armed condition. Note: When the automatic arming feature is activated, so is the RF tamper re-arm circuit. Every time the alarm is disarmed by remote, the RF tamper re-arm circuit will count for sixty seconds (LED will be flashing fast) and the alarm will re-arm itself if no one has entered the vehicle. 17

Step 10: Speciality Feature and Optional Equipment Testing LED Status Indicator Operation: LED is off = Alarm is disarmed. LED is flashing = Alarm is armed. LED is flashing in a 2 flash hold sequence = Tamper warning, alarm was triggered by the hood/ trunk or electronic sensor. LED flashing in a 3 flash hold sequence = Tamper warning, alarm was triggered by an open door. LED is on steady = Alarm is in the valet mode. (Ignition key is on ) LED flashes once every 5 seconds = Alarm is in the valet mode. (Ignition key is off ) LED is flashing fast = Automatic arming timer is counting down or RF tamper rearming timer is counting down. Parking Light Flash Alarm Status Indication: One light flash = Alarm is armed. Two light flash = Alarm is disarmed. Three light flash = Tamper indicator, alarm is disarmed. Siren/Horn Chirp Alarm Status Indication: Note: This feature can be programmed off, see Remote Feature Programming for details. One chirp = Alarm is armed and all input trigger wires are clear. Two chirps = Alarm is disarmed and has not been tampered with. Chirps once, pauses then chirps again = Alarm is armed but sensor is by-passed. Four chirps = Tamper indicator, alarm is disarmed. Power Door Lock/Unlock: (If Installed) 1. Arm the alarm with the transmitter, the locks will become locked. 2. Disarm the alarm with the transmitter, the locks will become unlocked. RF Tamper Re-Arm: Note: This feature is activated automatically when the alarm is programmed for automatic arming. See Remote Feature Programming for details. (Page 14-15) 1. Alarm must be programmed for automatic arming. 2. Close all protected entrances and arm the alarm with the remote transmitter. The LED will be flashing at a normal rate. 3. Wait 5 seconds and disarm the alarm using the remote transmitter. The LED will begin to flash fast. (Automatic arming indicator) 4. Wait 60 seconds and the alarm will become rearmed. 5. Repeat steps 1 through 4. When the LED starts flashing fast, open one of the protected entrances (door) the LED will be off and remain off. 60 Second Re-Arm Timer and Re-Lock Function: Once the alarm is triggered, the siren will sound for 60 seconds and then stop. The alarm will remain in an armed condition. If the door locks have been installed into the system, they will re-lock when the alarm resets after 60 seconds. 18

Step 10: Speciality Feature and Optional Equipment Testing Ignition Controlled Door Locking: (Door lock activation must be installed) When programmed on in Remote Feature Programming, ignition controlled locking is active 3 seconds after the ignition key is set the on position, the door locks will automatically become locked. When the ignition key is turned to the off position, the door locks will unlock. Note: If a protected entrance (Door) is open when the ignition key is set to the on position, the door locks will not lock. This is a non-deletable protective measure. Channel #2 Output: (If Installed) Press and hold the channel #2 activation button for 3 seconds. The designated channel 2 output wire from the alarm will become grounded for as long as button #2 is pressed. Channel #3 Output: (If Installed) Press and hold the channel #3 activation button for approximately 3 seconds. After 3 seconds the alarm will emit a ground signal from the channel #3 wire to operate the device connected to the channel #3 output wire of the alarm for as long as channel #3 button is pressed. Dual Zone Sensor Pre-Warning Indicator: (If Installed) 1. Close all protected entrances and place the alarm in an armed condition. 2. Rap the vehicles body panels to activate the pre-warning zone of any dual zone type sensor. 3. When the pre-warning indicator is triggered, the horn/siren will beep 1 time. Specifications Power Requirements... 12.5 Volts Negative Ground Trigger Inputs... Grounded Pin Switch, Positive Pin Switch, Electronic Sensor Ground, 0.6 Volt Current Drop Current Requirements... Less Than 15mA Armed or Disarmed Timers... Programmable Automatic Arming Timer Programmable Re-Arming Timer 60 Second RF Tamper Re-Arming Timer 5 Second Zone By-Pass Re-Activation Timer Grounded Output Wire Capacity (White Wire).. 500mA Siren Output Wire Capacity... 2 amps Channel 2 Pulsed Output... 0mA By-Pass Zones... 2 Zones Transmitter Frequency... 2mHz Digital Code Combinations... 500,000 Available Code Method... Digital Trinary Transmitter Channels... 2 Channels Receiver Channels... No More Than 3 19

ON Wiring Diagram PLUS-5000 Auxilliary Interrupt Socket (Orange) (See Optional Accessory Connection) Black Wire Antenna (Do Not Ground) Back View of Housing Auxilliary Interrupt Socket (Orange) Dip Switches 1 2 3 4 Dip Switches PLUS-5000 Controller Shock Sensor Socket (White) Power Harness Main Harness Channel #2 Output Pulsed Ground (See Optional Accessory Connection) Gray Wire Pulsed Ground for Car Horn (Ground) Starter Disable Plug-In LED (White) Domelight Supervision (See Optional Accessory Connection) Valet/Override Socket (Blue) Power Door Lock Harness Socket (Black) Blue/White Wire Channel #3 Output (Ground) Brown Wire Siren Output (+) Blue Wire Negative AUX Trigger Input Green Wire Negative Door Pin Trigger Input Violet Wire Positive Door Pin Trigger Input Red/White Wire Parking Lights Relay Output Pink Wire Parking Lights Relay Input Black Wire Ground to Vehicle Frame Yellow Wire To Ignition Switched +12V Red Wire To Battery +12V 11-18-99 rev. B PLUS50IM