GENERAL INDEX TR60. 6 YELLOW LINE Continuous Conductors. Max 5 Poles. 8 BLUE LINE Pre-Mounted Conductors TR85H5P. YELLOW LINE Continuous Conductors

Similar documents
4 pole insulated conductor rails ULA 35A, 50A, 80A, 100A

4 pole insulated conductor rails UNILIFT-ULA 35A, 50A, 80A, 100A

4 pole insulated conductor rails ULA 35A, 50A, 80A, 100A

4-Ductor Insulated conductor bar

Energy Supply Systems

Energy Supply Systems

ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES

A COMPLETE LINE OF INNOVATIVE PRODUCTS

CENTRE FEED UNIT UP TO 4000A. Safety

Multipole Conductor Rail MultiLine Program 0831

UNCHAINED ENERGY ELECTRIFICATION OF TRAVELLING MACHINES

Pro-Ductor Insulated flat conductor bar for 4, 7 or 10 conductors

GIOVENZANA INTERNATIONAL

Conductor Rail System for Shuttles MultiLine Program 0835

UNCHAINED ENERGY ELECTRIFICATION OF TRAVELLING MACHINES

E-LINETBS-TBE IEC EAE has full right to make any revisions or changes on this catalogue without any prior notice.

GIOVENZANA INTERNATIONAL

4 Pole / 5 Pole Enclosed Conductor System

VAHLE MOTOR POWERED CABLE REELS

Pro-Ductor Insulated flat conductor bar for 4, 7 or 10 conductors

Insulated Conductor Rail SinglePowerLine Program 0813

Distribution Blocks & Bus-bar Solutions

Insulated Conductor Rail SinglePowerLine Program 0812

Multipole Conductor Rail MultiLine Program 0831

Heavy-Duty Conductor Rail CopperHead

INSULATED CONDUCTOR SYSTEMS U 20 U 30 U 40

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

1 Product Description Check of the supplied Parts Notes Intended Use Current Collector... 3

Insulated Conductor Rail SinglePowerLine Program 0812

CRITO Connection technology. Double and triple T and TCC section busbars

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Electric Chain Hoists. CLF & CLW Series. The New CLF Series: Reliable, safe, convenient, efficient and compact size

Conductor Rail System for Shuttles MultiLine Program 0835

Electronic Circuit Breaker ESS20-0..

Product Overview Conductor Rails

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

PROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

TX³ RCCBs 2P up to 100 A

DX³ RCCBs - ID 4P up to 100 A

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design

Motor Starter Reverse MSR22-FBP

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

POWERFLOW. Your Idea System! Series. Series BUSWAY BUSBAR TRUNKING SYSTEM 630A 6300A ELECTRIC COMPAC ELECTRIC COMPAC ELECTRIC MAN. CO., LTD.

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

IEC Low Voltage General Purpose Protection

POWERAIL ENCLOSED CONDUCTOR SYSTEM VKS 10

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Data sheet chainflex CF6

Series T is Ideal for:

Spring Cable Reels EXEL

Electromotive Systems ELECTROBAR ELITE Conductor Bar System

55 Series - Miniature General Purpose Relays 5-10 A

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

POWERAIL ENCLOSED CONDUCTOR SYSTEM VKS 10

Bussmann series NH catalogue. Leadership in circuit protection

Automation - Lift - Handling System - Atex

ype UP T Busplugs Low Voltage Switchboard Equipment

Technical data Demag DC-Com 1 to DC-Com 10 chain hoist

CATALOGUE

DX³ 4-pole RCBO 6000 A/10 ka

Pendant stations for small hoist application, in single / double row or direct power circuits switchings and tail lift controls.

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

MS General Information Extended Product Type: MS

Essential equipment for all your requirements

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Phase + Neutral, neutral on left side

Fuse switch disconnectors

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

COMPACT CONDUCTOR SYSTEMS VKS 10

DPX 1600 Electronic release

Data sheet chainflex CF5

Vistop TM isolating switches 63 to 160A

Breakers and Switches. Switches Change-over and transfer switches

Technical data. DKK compact conductor lines engb IS eps

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

INSTALLATION RULES for SCS/SENSOR Pt100

1 Product Description Check of the supplied Parts Notes Intended Use Current Collector... 3

Data sheet chainflex CF240

Fuse switch-disconnectors

RiLine mm system technology for the global market

Varius SUMMARY OF MODELS

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

DPX 630 Electronic release

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Data sheet. Etaline GN /1852 G10 Version no.: 1 Inline pump. Operating data. Design. Requested developed head m

MOTIV- 8 FLEXIBLE CABLE SYSTEMS. www. James Crane.com.au PH:

Conveyors 12. slide strips roller Conveyors roller elements Conveyor rollers Chain Transfer

SWITCHGEAR. 4G cam switches

AF40... AF96 3-pole contactors Technical data

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Flexible energy and data transmission

Transcription:

2

Automation - Lift - Handling System GENERAL INDEX 2 DESCRIPTION 3 BUSBAR LINE VERSIONS LINE TYPE / AMPERAGE COVERAGE 5 TR60 40 A 50 A 60 A 70 A 100 A 140 A 160 A 200 A 320 A 6 YELLOW LINE Continuous Conductors Ma 5 Poles Ma 5 Conductors slot 8 BLUE LINE Pre-Mounted Conductors Ma 5 Poles 4 Poles 5 Poles 11 12 TR85H5P YELLOW LINE Continuous Conductors Ma 5 Poles Ma 5 Conductors slot 14 BLUE LINE Pre-Mounted Conductors Ma 5 Poles 4 Poles 5 Poles 17 TR85H7P 18 YELLOW LINE Continuous Conductors Ma 7 Poles Ma 7 Conductors slot Only 4 poles with parallel connections 20 BLUE LINE Pre-Mounted Conductors Only 4 poles with parallel connections Ma 7 Poles 7 Poles 23 ACCESSORIES 28 LINE CONSTRUCTION 30 SURVEY BUSBAR LINE 5-7 POLES - Rev. 01_2017 GIOVENZANA INTERNATIONAL B.V. reserves the right to modify, as specifications change,all technical and functional characteristics of the products shown in the catalogue without prior notice as this information is intended for general knowledge and is not legally binding. 32 33 TECHNICAL DATA NOTES www.giovenzana.com 1

DESCRIPTION BUSBAR LINE S VERSIONS BUSBAR LINE The trolley system series conductors rails is modern and safe system for energy transmission for various types of equipment, such as, cranes, bridge cranes, conveyour belts, chain conveyors, etc... The trolley system complies with the relevant international standards ensuring safety of the operator, easy installation and reliability. The new H honeycomb profile of the TR85H line guarantees etra endurance and lightness. TYPICAL LAYOUT BLUE LINE > PRE-MOUNTED CONDUCTORS The conductors are already inserted in the plastic casing With conductor joint 1 9 4 6 8 7 3 2 5 1 BUSBAR PVC Housing 2 CURRENT COLLECTOR Transmits the energy from the conductor to the machine 3 HEAD FEED BOX Connects power supply to the conductors 4 5 JOINT BOX END CAP Links two busbars Closes and protects the busbar end YELLOW LINE > CONTINUOUS CONDUCTORS The conductors are pulled from a coil without joints into the already installed casing. 6 7 IN-LINE FEED BOX HANGER Connects power supply from centre to avoid the voltage drop Connects the busbar to the brackets Without conductor joint 8 COPPER STRIP Transmits the energy from the power supply to the current collector 9 FIXED POINT Creates a fied point TYPICAL LINE UTILIZATION CRANE TECHNOLOGY ION AUTOMATION BMU PORT TECHNOLOGY PEOPLE MOVER SYSTEM STORAGE Cranes and Hoists Recycling plans Galvanized plants Electric systems Automated conveyors Building Maintenance Units Airport and terminal stations Skyscrapers Cleanroom technology RTG cranes STG cranes People movers Vertical elevators Inclined elevators High-bay warehouses Autometes storages 2 www.giovenzana.com 3

VERTICAL LINE Special application on request with customized parts. White RAL 1013 busbar customized for vertical installation. 4 www.giovenzana.com 5

BUSBAR SYSTEM TR60 YELLOW LINE BUSBAR SYSTEM TR60 YELLOW LINE 40A 60A YELLOW LINE - Continuous Conductors YELLOW LINE - Continuous Conductors 40A 60A 40A 60A BUSBAR 4 meters (*) TR6000 BRACKET TR6007 CONDUCTOR SIZE ETP Copper CS40 101-10mm 2 CS60 101,5-15mm 2 TR8510 JOINT BOX Plastic TR6001 FIXED POINT TR6014 HANGER Plastic TR6002 DOUBLE SUPPORT TR6013 Steel TR6020 FUNNELL TR6034 END CAP TR6006 SPRING LOADED For transfer guide FEED BOX TR6003 GASKET IP44 TR6012 IN-LINE FEED Clamps or screws + nuts not included TR6008 CONDUCTOR INSERTION TR6011 35A - 4 Conductors TR6004 DE-COIL UNIT TR8513 CURRENT COLLECTOR 35A - 5 Conductors TR6005 6 * Curved busbar available on request ONLY 4 conductors. www.giovenzana.com 7

BUSBAR SYSTEM TR60 BLUE LINE BUSBAR SYSTEM TR60 BLUE LINE 40A 60A BLUE LINE - Pre-Mounted Conductors BLUE LINE - Pre-Mounted Conductors 40A 60A 40A 60A BUSBAR 4 meters (*) 4 Conductors 5 Conductors Conductor type TR60404C TR60405C Included in busbar code 101-10mm 2 TR60604C TR60605C Included in busbar code 101,5-15mm 2 BRACKET TR6007 TR8510 JOINT BOX TR6001 FIXED POINT TR6014 HANGER Plastic TR6002 DOUBLE SUPPORT TR6013 Steel TR6020 LEFT - 4 Conductors TR6034A4 LEFT - 5 Conductors TR6034A5 END CAP TR6006 TRANSFER GUIDE RIGHT - 4 Conductors TR6035A4 4 Conductors TR6003A4 FEED BOX 5 Conductors TR6003A5 RIGHT - 5 Conductors TR6035A5 IN-LINE FEED 4 Conductors TR6008A4 SPRING LOADED For transfer guide 5 Conductors TR6008A5 35A - 4 Conductors TR6004 GASKET IP44 TR6012 CURRENT COLLECTOR 35A - 5 Conductors TR6005 8 * Curved busbar available on request ONLY 4 conductors. www.giovenzana.com 9

10 OBSERVATORY DOME www.giovenzana.com 11

BUSBAR SYSTEM TR85H5P YELLOW LINE BUSBAR SYSTEM TR85H5P YELLOW LINE 40A 70A 100A 140A YELLOW LINE - Continuous Conductors YELLOW LINE - Continuous Conductors 40A 70A 100A 140A 40A 70A 100A 140A BUSBAR 4 meters (*) TR85H5P BRACKET TR6007 CONDUCTOR SIZE ETP Copper RM40 15,50,6 9,3mm 2 RM70 15,51 15,5mm 2 RM100 15,51,5 23,25mm 2 RM140 15,52 31mm 2 TR8510 Plastic TR8501 FIXED POINT TR8527.1 JOINT BOX Steel TR8524 DOUBLE SUPPORT TR6013 Plastic TR8502 HANGER EXPANSION JOINT TR85H5P07 Steel TR8525 END CAP TR8506 INSPECTION JOINT TR85H5P28 FEED BOX TR8503 SECTION JOINT TR85H5P45 IN-LINE FEED Clamps or screws + nuts not included TR8547 FUNNELL TR85H5P34 35A - 4 Conductors TR8511 SPRING LOADED For transfer guide CURRENT COLLECTOR 35A - 5 Conductors 70A - 4 Conductors TR8512 TR8518 GASKET IP44 TR8505 CURRENT COLLECTOR FOR CURVES 70A - 5 Conductors 35A - 4 Conductors 70A - 4 Conductors TR8519 TR8516 TR8532 CONDUCTOR INSERTION DE-COIL UNIT TR8514 TR8513 12 * Curved busbar available on request ONLY 4 conductors. www.giovenzana.com 13

BUSBAR SYSTEM TR85H5P BLUE LINE BUSBAR SYSTEM TR85H5P BLUE LINE 40A 70A 100A 140A BLUE LINE - Pre-Mounted Conductors BLUE LINE - Pre-Mounted Conductors 40A 70A 100A 140A 40A 70A 100A 140A BUSBAR 4 meters (*) 4 Conductors TR85H5P404C TR85H5P704C TR85H5P1004C TR85H5P1404C 5 Conductors TR85H5P405C TR85H5P705C TR85H5P1005C TR85H5P1405C Conductor Type 15,50,6 15,51 9,3mm 2 15,5mm 2 Included in Busbar code 15,51,5 15,52 23,25mm 2 31mm 2 BRACKET TR6007 TR8510 JOINT BOX TR8535 FIXED POINT TR8527.1 HANGER Plastic TR8502 DOUBLE SUPPORT TR6013 Steel TR8525 END CAP TR8506 SECTION JOINT TR85H5P45B FEED BOX 4 Conductors 5 Conductors TR85H55P03A4 TR85H55P03A5 LEFT - 4 Conductors TR85H5P34A4 LEFT - 5 Conductors TR85H5P34A5 IN-LINE FEED TR8547 TRANSFER GUIDE RIGHT - 4 Conductors TR85H5P35A4 35A - 4 Conductors TR8511 CURRENT COLLECTOR 35A - 5 Conductors 70A - 4 Conductors 70A - 5 Conductors TR8512 TR8518 TR8519 SPRING LOADED RIGHT - 5 Conductors For transfer guide TR85H5P35A5 CURRENT COLLECTOR FOR CURVES 35A - 4 Conductors 70A - 4 Conductors TR8516 TR8532 GASKET IP44 TR8505 14 * Curved busbar available on request ONLY 4 conductors. www.giovenzana.com 15

CRANE ROUND HOIST 16 www.giovenzana.com 17

BUSBAR SYSTEM TR85H7P YELLOW LINE BUSBAR SYSTEM TR85H7P YELLOW LINE 50A 100A 160A 200A 320A YELLOW LINE - Continuous Conductors YELLOW LINE - Continuous Conductors 50A 100A 200A* 160A 320A* 50A 100A 200A* 160A 320A* BUSBAR 4 meters TR85H7P Single TR8557 CONDUCTOR SIZE ETP Copper CSH750 12,50,8 10mm 2 CSH7100 12,51,8 22,5mm 2 CSH7160 12,52,5 31,25mm 2 Double Triple TR8558 TR8559 JOINT BOX Plastic Steel TR8501 TR8524 4 POLES CONNECTION Single (3ph 70A - PE 35A) Double - need 2 (3ph 140A - PE 70A) Plastic TR8502 Triple - need 3 (3ph 210A - PE 105A) HANGER EXPANSION JOINT TR85H7P07 Steel TR8525 END CAP TR8506 INSPECTION JOINT TR85H7P28 FEED BOX Only for 7 poles till 100A TR85H7P005 - SECTION JOINT TR85H7P45 IN-LINE FEED Clamps or screws + nuts not included TR85H7P03 FUNNELL TRANSITION BOX For parallel connections 200A or 320A - SPRING LOADED For transfer guide FIXED POINT TR8527.1 GASKET IP44 TR8505 35A - Single TR85H7P001 CONDUCTOR INSERTION TR85H7P14 CURRENT COLLECTOR FOR CURVES 70A - Double TR85H7P002 DE-COIL UNIT TR8513 105A - Triple TR85H7P010 18 * The 200A and the 320A are obtained by parallel configuration ONLY for 4 poles. * The 200A and the 320A are obtained by parallel configuration ONLY for 4 poles. www.giovenzana.com 19

BUSBAR SYSTEM TR85H7P BLUE LINE BUSBAR SYSTEM TR85H7P BLUE LINE 50A 100A 160A 200A 320A BLUE LINE - Pre-Mounted Conductors BLUE LINE - Pre-Mounted Conductors 50A 100A 160A 200A* 320A* 50A 100A 160A 200A* 320A* 4 Conductors * - - - TR85H7P1007C TR85H7P1607C Single TR8557 BUSBAR 4 meters 7 Conductors * Conductor Type TR85H7P507C 12,50,8 10mm 2 TR85H7P1007C TR85H7P1607C 12,51,8 22,5mm 2 Included in busbar code 12,52,5 31,25mm 2 - - 2X (12,51,8) 222,5mm 2 2X (12,52,5) 231,25mm 2 Double Triple TR8558 TR8559 JOINT BOX Plastic TR85H7P007 TR8502 4 POLES CONNECTION Single (3ph 70A - PE 35A) Double - need 2 (3ph 140A - PE 70A) HANGER Triple - need 3 (3ph 210A - PE 105A) Steel TR8525 SECTION JOINT TR85H7P45B END CAP TR8506 LEFT - 7 Conductors FEED BOX 7 Conductors TR85H7P005A7 - IN-LINE FEED 7 Conductors TR85H7P03A7 TRANSFER GUIDE RIGHT - 7 Conductors TRANSITION BOX For parallel connections 200A or 320A - FIXED POINT TR8527.1 SPRING LOADED For transfer guide 35A - Single TR85H7P001 GASKET IP44 TR8505 CURRENT COLLECTOR FOR CURVES 70A - Double TR85H7P002 105A - Triple TR85H7P010 20 * The 200A and the 320A are obtained by parallel configuration ONLY for 4 poles. * The 200A and the 320A are obtained by parallel configuration ONLY for 4 poles. www.giovenzana.com 21

22 www.giovenzana.com 23

BUSBAR SYSTEM ACCESSORIES BUSBAR SYSTEM ACCESSORIES CODE CODE ø920 SUPPORT BRACKET (RAIL Fiing) Mounting Eample 2 arm clips kit included. THK 10mm L 32 L=350mm L=500mm TR8550 TR8551 TR60 CONDUCTORS CONNECTION Brass material TR6015 6 ø9 20 L=700mm TR8552 TR85H5P CONDUCTORS CONNECTION Brass material TR8548 32 L=350mm TR8555 SUPPORT BRACKET (Wall Fiing) L ø13 Wall drilling plan 30 90 50 60 3 L=500mm TR8556 TR85H5P CONDUCTORS CONNECTION (for IN-LINE FEED) Brass material TR8537 END CAP 32 29 25 30607015 13 ø12,5 ø17,5 12,5 14 15 TR85H7P CONDUCTORS CONNECTION KIT Flanged screw M612 Flanged nut M6 11606075 11612013 CABLE CLIP 30607016 30 68 23 30 32,5 28 TR85H5P 70A BRUSH KIT REPLACEMENT 1 Brush 2 Springs Only for: TR8518 TR8519 TR8532 TR8520 24 www.giovenzana.com 25

26 www.giovenzana.com 27

BUSBAR SYSTEM 1. LINE CONSTRUCTION LINE CONSTRUCTION To decide the size of trolleys it is necessary to consider: Maimum current in service Devices (cage motors, slip rings motors, resistors, electronic starters) Starting current of the devices Maimum ambient temperature The distance between device to the nearest power feed Voltage and admissible voltage drop in continuous and in starting service Type of current Devices cycle operations (load factor) CALCULATION OF THE VOLTAGE DROP Voltage drop should not eceed 5% of rated voltage in normal operating service. Three phase alternate current: u = 3 I Lt Z u% = u 100 U POWER FEED: BUSBAR TRACK LENGHT Keys: u = Voltage drop [V] u% = Voltage drop [%] I = Current intensity [A] Lt = Length of section [m] Z = Impendence [Ω/m] U = Voltage [V] A proper disposal of power feed points minimize the voltage reduction. If L is the lenght of the line, Lt is the track maimum length to consider the voltage reduction. A B C D A Lt = L - with ending/starting power feed Lt = L/2 - with in-line power feed Lt = L/6 - with power feed at 1/6 from each end Lt = L/10 - with three power feed at L/2 and L/10 from each end B BUSBAR SYSTEM 1. LINE CONSTRUCTION CURRENT IN CONTINUOUS SERVICE Specify the number of the devices which work simultaneously to calculate the corresponding current: In = l 1 + l 2 + l 3 +... The current can be determined from the devices power [W] that for a three phase system is: In = Pu 3 U cos ŋ Keys: In = Current consumption [A] Pu = Power devices [W] ŋ = Devices performance U = Operating Voltage [V] cos = Power factor In the absence of information on the operation of simultaneous devices, consider the following table: N OF IN-LINE LIFTING DEVICE LIFTING EQUIPMENT IN USE 1 ST ENGINE 2 ND ENGINE 3 TH ENGINE 4 TH ENGINE ma power engine* 1 decreasing power engine* 2 3 4 5 N 2 lifting equipment operating simultaneously * About ŋ motors connected in parallel with rated current In, consider In = ŋ In. STARTING CURRENT Calculate the numbers of the devices started simultaneously and the device already in service, then calculate the corresponding current. If the starting current is unknown, proceed with the following approimation: For a single user Ia = K In K = Starting current (Ia) Nominal current (In) As a general rule, consider: K = 5 to 6 for cage motors K = 2 for winding motors K = 2 for inverters (frequency converters) In the absence of information on the operation of simultaneous devices, consider the following table: LIFTING EQUIPMENT IN USE C D N OF IN-LINE LIFTING DEVICE 1 ST ENGINE 2 ND ENGINE 3 TH ENGINE 4 TH ENGINE Ia In Ia In Ia In Ia In 1 2 3 4 5 N 2 lifting equipment operating simultaneously 28 www.giovenzana.com 29

BUSBAR SYSTEM 2. SURVEY BUSBAR SYSTEM 2. SURVEY COMPANY NAME: COUNTRY: PHONE: DATE: CITY: CONTACT: MAIL: REFERENCE: 1.5 LAYOUT DRAWING 1 GENERAL DATA 1.1 TYPE OF INDUSTRY Crane BMU Storage Other 1.2 N MACHINE FOR TRACK 1.3 N OF TRACKS 1.4 TRACK LENGHT mt 1.5 TRACK LAYOUT mt straight - mt curved (Please include Layout Drawing on the net page) 2 ELECTRICAL DATA 2.1 2.2 2.3 POWER / CURRENT PER MACHINE MAX SIMULTANEOUS CURRENT PER TRACK POWER SUPPLY VOLTAGE 2.4 CONTROL SIGNALS Specify number Kw - Inom A - Istart A A V 50/60 Hz - n phases PE N - Voltage 2.5 3 SWITCH FREQUENCY AND DUTY CYCLE OF THE MACHINERY SYSTEM CONFIGURATION per - duty cycle 50% 60% 70% 80% 90% 100% 3.1 3.2 FEED POINT(S) CENTRE DISTANCE HANGERS At beginning - At mt from beginning - At mt from each end mt 4 3.1 MACHINE PARAMETERS TRAVEL SPEED mt/min 3.2 BUILD DIMENSIONS Please list if there are any build dimensions to take in consideration (include drawing) 5 1.1 1.2 1.3 6 ENVIRONMENTAL DATA INDOOR OR OUTDOOR MIN & MAX AMBIENT TEMP. ENVIRONMENTAL DETAILS OPTIONS Indoor outdoor C min C ma Normal Dusty Humid Corrosive Other 6.1 6.2 6.3 TRANSFER GUIDES SECTION JOINT IP44 RUBBER GASKET 6.3 OTHER Yes No Quantity Yes No Specify the position in the line Yes No 30 www.giovenzana.com 31

BUSBAR SYSTEM 3. TECHNICAL DATA NOTES GENERAL CHARACTERISTICS LINE / SIZE Operating current 23 C Comply with standards Markings Rated operating voltage [Ue] Frequency Conditional rated short circuit withstand current Fuse rating gg Protection class CEI EN 60529 Flammability resistance: UL94 Cei EN 60695-2-1 Ambient Temperature operating storage Ma admissible trolley speed ETP Copper strip section [mm 2 ] Resistance [Ω/m 10-4 ] Impendence [Ω/m 10-4 ] TR60 TR85H5P 40 60 40 70 100 140 50 40A 60A 40A 70A 100A 140A 50A 100A 160A CEI EN 60439-1, CEI EN 60439-2, CEI EN 60695-2-1, CEI EN 60570 600Vac 50Hz 10 ka 40A 60A 40A 70A 100A 140A 50A 100A 160A IP13 (IP44 with gasket accessories) 10 101 15 101,5 9,3 15,50,6 15,5 15,51 V0 960 C -30 C +55 C -30 C +70 C 200 m/min -1 23,25 15,51,5 31 15,52 10 12,50,8 TR85H7P 100 200* 22,5 12,51,8 160 320* 31,25 12,52,5 17 11,33 18,27 10,96 7,83 5,48 17 8,38 5,29 17,09 11,38 18,36 11,01 7,87 5,55 17,09 8,42 5,36 * The 200A and the 320A are obtained by parallel configuration, so only for 4 poles. The values indicated are referred to the single conductor. CONDUCTORS BARS WEIGHT TABLE LINE / SIZE Weight [kg/m] +/- 50g 4 poles 5 poles 7 poles TR60 TR85H5P TR85H7P 40 60 40 70 100 140 50 100 160 1,05 1,25 1,40 1,65 1,95 2,25 - - - 1,15 1,35 1,50 1,80 2,15 2,55 - - - - - - - - - 1,70 2,30 3,05 PVC BUSBAR CHARACTERISTICS MATERIAL CERTIFICATIONS RIGID PVC Self-etinguish Ultimate tensile strenght Yield point Modulus of elasticity Impact resistance Dielectric strenght Softening temperature - Vicat UL94 DIN 4102 D.M. 6/7/83 ISO R527 23 C ISO R527 23 C ISO R178 23 C DIN 53453 ASTM 149 ISO R306 49N V0 B2 CI 430 kg/cm 3 460 kg/cm 3 30.000 kg/cm 3 Unbroken 25 kv/mm 82 C 32 www.giovenzana.com 33