Technical Data Sheet , Rev HB October Rosemount 8800 Vortex Installation Effects

Similar documents
Technical Data Sheet , Rev HA October Rosemount 8800 Vortex Installation Effects

Rosemount 8800 Vortex Installation Effects

Model 8800C Vortex Installation Effects English Rev. CA

Coriolis Flowmeter with Model 1700 or Model 2700 Transmitter

Micro Motion F-Series Coriolis Flow and Density Sensors. Installation Manual , Rev CC December 2010

Installation Manual , Rev CG January Micro Motion F-Series Coriolis Flow and Density Sensors

Micro Motion F-Series Coriolis Flow and Density Sensors. Installation Manual , Rev CF January 2018

Micro Motion. CMF400 Sensor. Installation Instructions. Quick Reference Guide P/N , Rev. D May 2003

Installation Manual P/N , Rev. DA June Micro Motion ELITE Coriolis Flow and Density Sensors

Installation Manual , Rev DI March Micro Motion ELITE Coriolis Flow and Density Sensors

Installation Manual , Rev DD April Micro Motion ELITE Coriolis Flow and Density Sensors

Rosemount Orifice Series Differential Pressure Flow

Rosemount 285 Annubar Primary Element Series

Rosemount 405 Compact Primary Element. Quick Start Guide , Rev HA June 2016

Installation Manual , Rev DH October Micro Motion ELITE Coriolis Flow and Density Sensors

Micro Motion ELITE Mass Flow and Density Meters

Air Flow Measurement Technologies

KNOWLEDGE

REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY

VERIS FLOW MEASUREMENT GROUP

Fluid Flow Conditioning

Model 1000 Vortex Meter

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Technical Data Sheet PS , Rev C May Micro Motion R-Series Coriolis Flow and Density Meters

Rosemount 485 Annubar Pak-Lok Assembly

F-2500 SERIES VORTEX METER

flow measurement solutions RIM10 series rotor insertion flowmeters

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

REVOLUTIONIZE YOUR DENSITY AND CONCENTRATION MEASUREMENT TECHNOLOGY

White paper: Originally published in ISA InTech Magazine Page 1

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

Fundamental Training. Flow Con t

The products you need when you need them.

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

Installation Manual , Rev DL July Micro Motion ELITE Coriolis Flow and Density Sensors

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

F-2600 SERIES INLINE VORTEX FLOW METER

Rosemount 585 Annubar Flanged Flo-Tap Assembly

Rosemount 485 Annubar Flanged Assembly

Vortex Flow Meter Model DVH

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions

F-2700 SERIES INSERTION VORTEX FLOW METER

ORIMAS Mass Flowmeter

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment

F-2700 SERIES INSERTION VORTEX FLOW METER

VACOMASS. Technical information VACOMASS square diaphragm control valve

Rosemount 285 Annubar Pak-Lok Assembly

Rosemount 228. Toroidal Conductivity Sensor. Product Data Sheet July Series LIQ-PDS-228

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

STEEMCO-MAS Flowmeter for Steam

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Vortex Flowmeter Model DVE

1495 Orifice Plate 1496 Flange Union 1497 Meter Section Installation & Operation Manual

Armstrong In-Line and Insertion Vortex Flow Meters

STEEMCO Flowmeter for Steam

Multivariable Vortex Flow Meter

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Model 5000 Vortex Meter

Experiment (4): Flow measurement

PVP Field Calibration and Accuracy of Torque Wrenches. Proceedings of ASME PVP ASME Pressure Vessel and Piping Conference PVP2011-

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Flow Measurement SITRANS F S Clamp-on

F-2600 SERIES INLINE VORTEX FLOW METER

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

HydroPro UNIVERSAL STRAIGHT VALVE TESTER USV

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Micro Motion Technical Overview and Specification Summary

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

ONICON Insertion Turbine Flow Meters Single Turbine vs. Dual Turbine Selection Criteria

Multivariable Vortex Flow Meter

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

Quick Start Guide , Rev FB June Rosemount 485 Annubar Flanged Flo-Tap Assembly

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Now available with MVD Technology! ELITE Mass Flow and Density Meters

DIGIFLO ELECTRONIC FLOWMETER

Rosemount Pipe Clamp RTD Sensor

Hydro-Flow Model 3100

CBA-Series Pneumatic Dimension Data Metric

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Product Data Sheet PS February Model D and DT. Mass Flow and Density Sensors.

RTD and Thermocouple Assemblies Reference Manual

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT

Vortex Plate. Model VP General Specification. Product Features

HydroPro UNIVERSAL STRAIGHT VALVE TESTER USV

Instruction Manual Vortex Flow Meter DVH / DVE

VM2050S,2150,2150SV GLOBE VALVE GRINDING & LAPPING MACHINE

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems

Transcription:

Technical Data Sheet 00816-0100-3250, Rev HB October 2018 Rosemount 8800 Vortex Installation Effects

2

Technical Data Sheet Contents 00816-0100-3250 October 2018 Contents Chapter 1 Introduction... 5 1.1 Temperature effects on K-factor... 5 1.2 Pipe ID effects on K-factor... 5 1.3 Upstream and downstream piping configurations... 6 1.4 In plane versus out of plane... 6 Chapter 2 Correcting the output of the vortex meter... 9 2.1 Fieldbus and HART software revisions 5.2.8 or earlier... 9 2.2 HART software revisions 5.3.1 or 7.2.1 and later... 11 2.3 Correction factor examples... 13 Chapter 3 Calculating upstream and downstream pipe diameters... 21 Technical Data sheet 3

Contents Technical Data Sheet October 2018 00816-0100-3250 4 Rosemount 8800D Safety Manual

Technical Data Sheet Introduction 00816-0100-3250 October 2018 1 Introduction The Rosemount 8800 Vortex Flowmeter provides methods for maintaining accuracy in less than ideal installations. In designing the 8800, Emerson tested the meter for three separate types of installation effects: Process fluid temperature variation Process piping inside diameter Upstream and downstream disturbances As a result of this testing, compensation factors are included in the vortex meter software; this allows the output of the vortex meter to be adjusted for the actual process temperature and process piping being used. Data is presented in this paper to demonstrate the effectiveness of the design in limiting the errors resulting from piping disturbances. For upstream disturbances caused by pipe elbows, contractions, expansions, etc., Emerson has conducted extensive research in a flow lab to determine the effect that these have on the meter output. These tests are the basis for the recommended 35 upstream piping diameters. While this is optimal, it is not always possible in the real world of plant design and layout. Therefore, the data presented in this paper outlines the effects of different upstream and downstream piping conditions on the vortex flowmeter. 1.1 Temperature effects on K-factor The vortex flowmeter is fundamentally a velocity measuring device. As fluid flows past the shedder bar, vortices are shed in direct proportion to the fluid velocity. If the process temperature is different than the reference calibration temperature, the flowmeter bore diameter will change slightly. As a result, the velocity across the shedder bar will also change slightly. For example; an elevated process temperature will cause an increase in the bore diameter, which in turn will cause a decrease in the velocity across the shedder bar. Using the Reference K-factor and the value for Process Temperature input by the user, the Rosemount 8800 automatically calculates for the effect of temperature on the flowmeter by creating what is called the Compensated K-factor. The Compensated K-factor is then used as the basis for all flow calculations. 1.2 Pipe ID effects on K-factor All Rosemount 8800 Vortex Flowmeters are calibrated in schedule 40 pipe. From extensive testing done in piping with different inside diameters/schedules, Emerson has observed there is a small K-factor shift for changes in process pipe ID (inside diameter). This is due to the slight change in velocity at the inlet to the flowmeter. These changes have been programmed in to the 8800 electronics and will be corrected for automatically when the user supplied pipe ID is other than schedule 40. Technical Data sheet 5

Introduction Technical Data Sheet October 2018 00816-0100-3250 1.3 Upstream and downstream piping configurations The number of possible upstream and downstream piping configurations is infinite. Therefore, it is not possible to have software automatically calculate a correction factor for changes in upstream piping. Fortunately, in almost all cases, elbows, reducers, etc. cause less than a 0.5% shift in the flowmeter output. In many cases, this small effect is not a large enough shift to cause the reading to be outside of the accuracy specification of the flowmeter. The shifts caused by upstream piping configurations are basically due to the changes in the inlet velocity profile caused by upstream disturbances. For example, as a fluid flows around an elbow, a swirl component is added to the flow. Because the factory calibration is done in a fully-developed pipe flow, the swirl component caused by the elbow will cause a shift in the vortex flowmeter output. Given a long enough distance between an elbow and the flowmeter, the viscous forces in the fluid will overcome the inertia of the swirl and cause the velocity profile to become fully-developed. There rarely is sufficient length in actual process piping installations for this to occur. Even though the flow profile may not be fully-developed, testing indicates that the Rosemount vortex flowmeter can be located within 35 pipe diameters of the elbow with minimal effect on the accuracy or repeatability of the flowmeter. Although the upstream disturbance may cause a shift in the K-factor, the repeatability of the vortex flowmeter is normally not affected. For example, a flowmeter 20 pipe diameters downstream of a double elbow will be as repeatable as a flowmeter in a straight pipe. Testing also indicates that while the K-factor is affected by upstream piping, the linearity of the flowmeter remains within design specifications. In many applications, this means that no adjustment for piping configuration will be necessary even when the minimum recommended installation lengths of upstream and downstream piping cannot be used. On the following pages are drawings illustrating various installation configurations. Extensive testing has been performed in a flow lab with these specific configurations. The results of those tests are shown as a series of graphs indicating the shift in the mean K- factor for a vortex flowmeter placed downstream of a flow disturbance. 1.4 In plane versus out of plane In the graphics, the terms in plane and out-of-plane are used. A butterfly valve and a vortex flowmeter are considered to be in plane when the shaft of the valve and the shedder bar of the vortex flowmeter are aligned (e.g. both the shaft and the shedder bar are vertical.) A butterfly valve and a vortex flowmeter are considered to be in plane when the shaft of the valve and the shedder bar of the vortex flowmeter are aligned (e.g. both the shaft and the shedder bar are vertical). They are considered out of plane the shaft and shedder bar are offset by 90. 6 Rosemount 8800D Safety Manual

Technical Data Sheet Introduction 00816-0100-3250 October 2018 Figure 1-1: Butterfly valve A B A. In plane B. Out of plane An elbow is considered in plane when the shedder bar and elbow are aligned. The elbow is considered out of plane when the shedder bar and elbow are rotated 90. Figure 1-2: Single elbow A B A. In plane B. Out of plane Similarly, double elbows are in plane when the are both aligned with the shedder bar and out of plane when they are not aligned with the shedder bar. Technical Data sheet 7

Introduction Technical Data Sheet October 2018 00816-0100-3250 Figure 1-3: Double elbow same plane A B A. In plane B. Out of plane 8 Rosemount 8800D Safety Manual

Technical Data Sheet Correcting the output of the vortex meter 00816-0100-3250 October 2018 2 Correcting the output of the vortex meter Correction factors can entered into the vortex flowmeter transmitter using AMS Device Manager, ProLink III v3 or a 475, AMS Trex(TM), or similar HART Field Communicator. For all Fieldbus devices and devices with HART software revisions 5.2.8 and earlier, the K- factor can be adjusted using the Installation Effect command. This command will adjust the compensated K-factor to account for any correction needed. The correction will be entered as a percentage of the K-factor shift. The possible range of the shift is +1.5% to -1.5%. For devices with HART revision 5.3.1 or 7.2.1 and later, the correction factor will be entered using the Meter Factor command. This command works in a similar way to the Installation Effect command but has an inverse relationship to k-factor shift and an enterable range of 0.8 to 1.2. Entering a value of 0.8 represents a +20% shift in k-factor, a value of 1.0 represents a 0% shift in k-factor, and a value of 1.2 represents a -20% shift in k-factor. 2.1 Fieldbus and HART software revisions 5.2.8 or earlier Using AMS Device Manager Under the Sensor tab, enter the correction in the Install Effect field. Figure 2-1: Using AMS Device Manager Technical Data sheet 9

Correcting the output of the vortex meter Technical Data Sheet October 2018 00816-0100-3250 Using a 475 HART Field Communicator Go to Manual Setup > Sensor > Process > Installation Effect and then enter the correction number in the field. Figure 2-2: Using a 475 HART Field Communicator Using ProLink III To enter the Installation Effect, select Device Tools > Configuration > Device Setup > Installation Effect. 10 Rosemount 8800D Safety Manual

Technical Data Sheet Correcting the output of the vortex meter 00816-0100-3250 October 2018 Figure 2-3: Using ProLink III 2.2 HART software revisions 5.3.1 or 7.2.1 and later Using AMS Device Manager Under the Sensor tab, enter the correction in the Meter Factor field. See Figure 1-4. Technical Data sheet 11

Correcting the output of the vortex meter Technical Data Sheet October 2018 00816-0100-3250 Figure 2-4: Using AMS Device Manager Using a 475 HART Field Communicator Go to Manual Setup > Sensor > Process > Meter Factor and then enter the correction number in the field. Figure 2-5: Using a 475 HART Field Communicator Using ProLink III To enter the Installation Effect, select Device Tools > Configuration > Device Setup > Meter Factor. 12 Rosemount 8800D Safety Manual

Technical Data Sheet Correcting the output of the vortex meter 00816-0100-3250 October 2018 Figure 2-6: Using ProLink III 2.3 Correction factor examples Example 1 The 8800 Vortex flowmeter is installed 15 pipe diameters downstream from a single 90 elbow, with the shedder bar in plane. Looking at Single Elbow Graph and following the IN PLANE line, the K-factor shift would be +0.3% at 15 pipe inside diameter. To adjust the K-factor to correct for this shift, enter +0.3% into the Installation Effect field or 0.997 for devices utilizing Meter Factor. Example 2 The 8800 Vortex flowmeter is installed 10 pipe diameters downstream from a butterfly valve, with the shedder bar out of plane. Looking at Butterfly Graph and following the OUT OF PLANE line, the K-factor shift would be -0.1% at 10 pipe inside diameter. To adjust the K-factor to correct for this shift, enter -0.1% into the Installation Effect field or 1.001 for devices utilizing Meter Factor. Technical Data sheet 13

Correcting the output of the vortex meter Technical Data Sheet October 2018 00816-0100-3250 Figure 2-7: Single elbow A B 1.5 % K-factor shift 1.0 0.5 0.0 0.5 In plane Out of plane 0 5 10 15 20 25 30 35 40 0.10 1.5 Upstream pipe diameters A. In plane B. Out of plane 14 Rosemount 8800D Safety Manual

Technical Data Sheet Correcting the output of the vortex meter 00816-0100-3250 October 2018 Figure 2-8: Pipe expansion 1.5 % K-factor shift 1.0 0.5 0.0 0.5 In/out of plane 0 5 10 15 20 25 30 35 40 0.10 1.5 Upstream pipe diameters K-Factor shift based on data collected with concentric pipe expander. Technical Data sheet 15

Correcting the output of the vortex meter Technical Data Sheet October 2018 00816-0100-3250 Figure 2-9: Double elbow same plane A B 1.5 % K-factor shift 1.0 0.5 0.0 0.5 In plane Out of plane 0 5 10 15 20 25 30 35 40 0.10 1.5 Upstream pipe diameters A. In plane B. Out of plane 16 Rosemount 8800D Safety Manual

Technical Data Sheet Correcting the output of the vortex meter 00816-0100-3250 October 2018 Figure 2-10: Double elbow different plane A B 1.5 % K-factor shift 1.0 0.5 0.0 0.5 In plane Out of plane 0 5 10 15 20 25 30 35 40 0.10 1.5 Upstream pipe diameters A. In plane B. Out of plane Technical Data sheet 17

Correcting the output of the vortex meter Technical Data Sheet October 2018 00816-0100-3250 Figure 2-11: Reducer 1.5 1.0 % K-factor shift 0.5 0.0 0.5 In/out of plane 0 5 10 15 20 25 30 35 40 0.10 1.5 Upstream pipe diameters K-Factor shift based on data collected with concentric pipe expander. 18 Rosemount 8800D Safety Manual

Technical Data Sheet Correcting the output of the vortex meter 00816-0100-3250 October 2018 Figure 2-12: Butterfly valve A B 1.5 % K-factor shift 1.0 0.5 0.0 0.5 In plane Out of plane 0 5 10 15 20 25 30 35 40 0.10 1.5 Upstream pipe diameters A. In plane B. Out of plane Technical Data sheet 19

Correcting the output of the vortex meter Technical Data Sheet October 2018 00816-0100-3250 20 Rosemount 8800D Safety Manual

Technical Data Sheet Calculating upstream and downstream pipe diameters 00816-0100-3250 October 2018 3 Calculating upstream and downstream pipe diameters A A. Pipe inside diameters calculated face to face Note When using a reducer-style flow meter, pipe inside diameters are calculated using the process pipe inside diameter not the meter body inside diameter. Technical Data sheet 21

*00816-0100-3250* 00816-0100-3250 Rev. HB 2018 Emerson Automation Solutions USA 7070 Winchester Circle Boulder, Colorado USA 80301 T +1 303-527-5200 T +1 800-522-6277 F +1 303-530-8459 www.emerson.com Emerson Automation Solutions Europe Neonstraat 1 6718 WX Ede The Netherlands T +31 (0) 70 413 6666 F +31 (0) 318 495 556 www.micromotion.nl Emerson Automation Solutions Asia 1 Pandan Crescent Singapore 128461 Republic of Singapore T +65 6363-7766 F +65 6770-8003 Emerson Automation Solutions United Kingdom Emerson Process Management Limited Horsfield Way Bredbury Industrial Estate Stockport SK6 2SU U.K. T +44 0870 240 1978 F +44 0800 966 181 2018 Rosemount, Inc. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount, 8600, 8700, 8800 marks are marks of one of the Emerson Automation Solutions family of companies. All other marks are property of their respective owners.