EX-REPAIR AND MAINTENANCE RECEPTACLES

Similar documents
International approvals.

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

A good connection. International approvals.

Unused flameproof threads for cable glands have to be closed with certified plugs.

I Ex-safety switches I

A good connection. International approvals.

I Ex-Safety switches I

I Ex-safety switches I

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Internationally approved.

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

I Ex-control stations I

EX-D ENCLOSURES AND DISTRIBUTIONS

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

I Ex-e/Ex-i terminal box I

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

EX-RECESSED CEILING LIGHT FITTINGS

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

ELECTRICAL CONNECTIVITY

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Installation Accessories

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Plug and Socket Devices SolConeX 16 A Series 8570

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Safety Switches Series 8537

10 Load and Motor Switchgear

Dust - an Explosive Risk

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

7 Lighting Technology

LED Linear Luminaire Series EXLUX 6402

11 Control Panels, Distribution Panels and Components

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

The Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.

Leading the way in hazardous areas Features EATON

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

Emergency Light Fitting for Fluorescent Lamps Series 6009

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

PRE Series 63 Amp Plugs and Sockets Increased Safety

7 Lighting Technology

Sicherheit, auf die Sie sich verlassen können

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

Sheet-Steel Light Fittings Series 6014 / 6414

Emergency Luminaire with LED Series EXLUX 6409/1

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Linear Luminaire with LED Series EXLUX 6402/2

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

HTSB system System overview

PRE Series 125 Amp Plugs and Sockets Increased Safety

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Linear luminaire with LED Series EXLUX 6002

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

ellk/m 92 LED 400/800

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear fluorescent luminaire LED V-CG-S

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Linear Luminaire with LED Series EXLUX 6002

Sheet Steel Emergency Light Fitting Series 6018

9 Control Equipment. Control Unit System Series ConSig 8040

Terminal Boxes Series 8125

Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

ellk 92 LED Light Fittings

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

GHG43 Series Control Stations

EX-CEILING, PENDANT LIGHT FITTINGS AND FLOODLIGHTS

7 Lighting Technology

Control Device System NEC Series ConSig 8040

EX-FLUORESCENT LIGHT FITTINGS

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear fittings EVNL LED fitting - zones 2, & 22

Control Stations CP.../EFDCN

EX-CEILING PENDANT LIGHT FITTINGS AND FLOODLIGHTS

Operating Instructions

Ex UPS standard Series 8265

Linear fittings EVDL LED fitting - zones 21, & 22

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

SynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

IECEx Certificate of Conformity

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Transcription:

EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand grinders and such are needed but are not in accordance to the explosion-protection regulations. To be able to use these appliances in the Zone, Zone 2, Zone 2 or Zone 22 explosion-protected areas a hot work permit has to be issued. For the duration of the repair or maintenance work, the environment has to be free of all explosive hazardous atmospheres. The CEAG explosion-protected repair and maintenance receptacles are in accordance to regulations that in parts require a stationary installation. With the interlocking and lockable switch or the lockable cover the utilization of the repair and maintenance receptacles is selectively possible after a hot work permit has been issued. The CEAG repair and maintenance receptacles with and without an interlocking switch can be used with both industry and Ex-plugs. Interlocked repair and maintenance receptacles have an internal switch who prevents that a plug can be pulled out while power is on. The interlock is activated by turning the plug. Repair and maintenance sockets without an interlocking switch have a red signal lamp on the top side of the housing showing the actual state of power. International approvals Commercially available industrial apparatus can be used with a hot work permit Sockets with lamellar contacts for a secure connection Switch and/or socket cover are lockable High mechanical, chemical and thermal stability 2..88 EATON S CROUSE-HINDS BUSINESS

I Ex-Repair- and Maintenance Receptacles: A 3-pole and 5-pole up to 45 V I non-interlocked non-interlocked interlocked Technical data Ex-receptacles accd. to IEC 0309-/2 Marking accd. to 94/9/EC II 2 G Ex ed IIC T / II 2 D Ex td A2 IP T80 C/T95 C EC-Type Examination Certificate PTB 00 ATEX 032 X Permissible ambient temperature 20 C to +40 C ) Rated voltage up to 440 V (AC) Rated current A (AC) Frequency 50/0 Hz Rated making / Rated breaking capacity AC-3 accd. EN 0947-3 U e 45 V / I e A External back-up fuse, max. without therm. protection: A with therm. protection: 35 A gl (rated current A set to) Protection class I Degree of protection accd. to EN 0529 IP Cable entry x M25 Ø 8-7 mm, x M25 plastic Ex-screw plug or 2 x metal thread M20 with plastic Ex-screw plug Connecting terminals 2 x.0-4 mm 2 Enclosure material glass-fibre reinforced polyester ) extended temperature range on request EATON S CROUSE-HINDS BUSINESS 2..89

I Ex-Repair- and Maintenance Receptacles: A 3-pole and 5-pole up to 45 V I interlocked non-interlocked non-interlocked Ordering details Voltage h Type Cable entry Weight approx. Order No. Type CEE A 3-pole, interlocked 200-250 V Wall socket KU. kg GHG 5 430 R090 Wall socket ME.2 kg GHG 5 430 R390 Wall socket GM.2 kg GHG 5 430 R3902 Plug GHG 5 730 R000 Type CEE A 3-pole, non-interlocked 200-250 V Wall socket KU.2 kg GHG 5 430 R0903 Wall socket ME.3 kg GHG 5 430 R3905 Wall socket GM.3 kg GHG 5 430 R390 Plug GHG 5 730 R000 Type A 2-pole, non-interlocked PE-contact 230 V Wall socket ) KU.2 kg GHG 5 430 R0902 Wall socket ) ME.3 kg GHG 5 430 R3903 Wall socket ) GM.3 kg GHG 5 430 R3904 Schutzkontakt ) Voltage h Type Aux. contact Cable entry Weight approx. Order No. Type CEE A 5-pole, interlocked 380-45 V Wall socket KU. kg GHG 5 450 R090 Wall socket ME.7 kg GHG 5 450 R390 Wall socket yes KH. kg GHG 5 450 R0903 Plug GHG 5 750 R000 Type CEE A 5-pole, non-interlocked 380-45 V Wall socket KU.8 kg GHG 5 450 R0902 Wall socket ME.9 kg GHG 5 450 R3902 Wall socket yes KH.8 kg GHG 5 450 R0904 Plug GHG 5 750 R000 Other voltage ranges and versions available on request GM = 2 x metal thread M20 without cable gland/thread plug with protective earth KU = x plastic cable glands M25, x M25 plastic Ex-screw plug ME = 2 x metal thread M20 with plastic Ex-screw plug KH = 2 x plastic cable glands M25 Ø 8-7 mm, with, x NO ) Not compatible with GHG 5 730 R000 2..90 EATON S CROUSE-HINDS BUSINESS

I Ex-Repair- and Maintenance Receptacles: A 3-pole and 5-pole up to 45 V I non-interlocked non-interlocked interlocked Dimension drawing I Wiring diagram 90 X80 2 0 X00 47 7 7 Wall socket interlocked 3-pole Dimensions in mm 223 55 X5 23 75 X35 Wall socket interlocked 5-pole 20 X0 8 20 X0 8 33 33 22.5 22.5 0 273 205 X 70 0 273 205 X 70 Wall socket non-interlocked 3-pole Wall socket non-interlocked 5-pole 20 X0 33 22.5 8 0 243 205 X 70 7 Wall socket non-interlocked with earthing contact 3-pole X = fixing dimensions with earthing contact without L L2 L3 N PE with L L2 L3 3 N PE P + N + PE 4 3 P + N + PE 3 P + N + AUX + PE EATON S CROUSE-HINDS BUSINESS 2..9

I Ex-Repair- and Maintenance Receptacles: 32A 5-pole up to 45 V I interlocked non-interlocked Technical data Ex-receptacles accd. to IEC 0309-/2 Marking accd. to 94/9/EC II 2 G Ex ed IIC T / II 2 D Ex td A2 IP T80 C / T95 C EC-Type Examination Certificate PTB 00 ATEX 032 X Permissible ambient temperature 20 C to +40 C ) Rated voltage 440 V (AC) Rated current 32 A Frequency 50/0 Hz Rated making / Rated breaking capacity AC-3 accd. EN 0947-3 U e 90 V / I e 32 A External back-up fuse, max. without therm. protection: 35 A with therm. protection: 50 A gl (rated current 32 A set to) Protection class I Degree of protection accd. to EN 0529 IP Cable entry x M40 Ø 7-28 mm, x M40 plastic Ex-screw plug or 2 x metal thread M32 with plastic Ex-screw plug Connecting terminals 2 x 4-0 mm 2 Enclosure material glass-fibre reinforced polyester ) extended temperature range on request 2..92 EATON S CROUSE-HINDS BUSINESS

I Ex-Repair- and Maintenance Receptacles: 32A 5-pole up to 45 V I non-interlocked interlocked Ordering details Voltage h Type Aux. contact Cable entry Weight approx. Order No. Type 32 A 5-pole, interlocked 380-45 V Wall socket KU 2.3 kg GHG 52 450 R090 Wall socket ME 2.4 kg GHG 52 450 R390 Wall socket yes KH 2.3 kg GHG 52 450 R0903 Type 32 A 5-pole, non-interlocked 380-45 V Wall socket KU.8 kg GHG 52 450 R0904 Wall socket ME.9 kg GHG 52 450 R3902 Wall socket yes KH.8 kg GHG 52 450 R0905 Other voltage ranges and versions available on request. KU = x plastic cable glands M40 Ø 7-28 mm, x M40 plastic Ex-screw plug ME = 2 x metal thread M32 with plastic Ex-screw plug KH = x plastic cable glands M40 Ø 7-28 mm, x plastic cable glands M25 Ø 8-7 mm Dimension drawing I Wiring diagram 20 8 X0 42 20 X0 7 2 7 3 7 293 205 X70 Wall socket interlocked 5-pole Dimensions in mm 0 X 247 27 7 Ø84 Wall socket non-interlocked 5-pole X = fixing dimensions without L L2 L3 N PE with L L2 L3 3 N PE 4 3 P + N + PE 3 P + N + AUX + PE EATON S CROUSE-HINDS BUSINESS 2..93

I Ex-Repair- and Maintenance Receptacles: 3A 5-pole up to 45 V I interlocked non-interlocked Technical data Ex-receptacles accd. to IEC 0309-/2 Marking accd. to 94/9/EC II 2 G Ex ed IIC T / II 2 D Ex td A2 IP T80 C/T95 C EC-Type Examination Certificate PTB 00 ATEX 032 X Permissible ambient temperature 20 C to +40 C ) Rated voltage 550 V (AC) Rated current 3 A (AC) Frequency 50/0 Hz Rated making / Rated breaking capacity AC-3 accd. EN 0947-3 U e 90 V / I e 3 A External back-up fuse, max. without therm. protection: 3 A with therm. protection: 80 A gl (rated current 3 A set to) Protection class I Degree of protection accd. to EN 0529 IP Cable entry x M50 Ø 22-35 mm, x M50 plastic Ex-screw plug 2 x metal thread M40 with plastic Ex-screw plug Connecting terminals 2 x 4-25 mm 2 Enclosure material glass-fibre reinforced polyester ) extended temperature range on request 2..94 EATON S CROUSE-HINDS BUSINESS

I Ex-Repair- and Maintenance Receptacles: 3A 5-pole up to 45 V I non-interlocked interlocked Ordering details Voltage h Type Aux. contact Cable entry Weight approx. Order No. Type 3 A 5-pole, interlocked 380-45 V Wall socket KU 8. kg GHG 54 450 R090 Wall socket ME 8.3 kg GHG 54 450 R390 Wall socket yes KH 8. kg GHG 54 450 R0903 Type 3 A 5-pole, non-interlocked 380-45 V Wall socket KU 8. kg GHG 54 450 R0904 Wall socket ME 8.3 kg GHG 54 450 R3902 Wall socket yes KH 8. kg GHG 54 450 R0905 25 A and other versions on request KU = x plastic cable glands M50 Ø 22-35 mm, x M50 plastic Ex-screw plug ME = 2 x metal thread M40 with plastic Ex-screw plug KH = x plastic cable glands M50 Ø 22-35 mm, x plastic cable glands M25 Ø 8-7 mm, with, x NO Dimension drawing I Wiring diagram 200 X84 0 22 200 X84 33 22 0 9 9 Wall socket interlocked 5-pole Dimensions in mm 475 370 X27 475 370 X 27 Wall socket non-interlocked 5-pole X = fixing dimensions without L L2 L3 N PE with L L2 L3 3 N PE 4 3 P + N + PE 3 P + N + AUX + PE EATON S CROUSE-HINDS BUSINESS 2..95