Beaver Rd Grow Adelanto, CA September 21, 2017 600kW Stand-Alone power system with cooling We are pleased to offer the following proposal for a C600S microturbine with Cooling. This system will provide reliable clean power and cooling for your Grow facility. The system will act as your facility s power utility, running independent from the SCE grid. Due to the large amount of power required at the site and limitation on SCE power availability, running isolated from the grid is required. While the microturbines provide clean and reliable power the included exhaust gas fired absorption chillers will provide about 188 RT of cooling for use in climate control. This high efficiency design and re-capture of exhaust energy provides an approx. net annual energy savings of $600,000 against the SCE s TOU-8 utility tariff. Capstone microturbines feature a patented low maintenance air bearing technology, the lowest emissions of any non-catalyzed gas combustion engine, and digital power conversion to stand as the optimal power generation solution. The stand-alone power plant consists of 3 200kW power modules, each capable of independent operation. This configuration ensures full power is available in any operating condition and provides redundancy for reliable power during unplanned equipment outages and during planned maintenance.
The C600S Signature Series Microturbine provides up to 600kW of reliable electrical power in one small, ultra-low emission, and highly efficient package. Ø Ultra-low emissions - eliminates maintenance and safety hazard of catalytic reduction system Ø Modular design provides inherent N+1 redundancy on a smaller scale Ø One moving part minimal maintenance and downtime Ø Patented air bearings no lubricating oil or coolant Ø Compact modular design allows for easy, low-cost installation Ø High electrical efficiency over a very wide operating range Ø High availability part load redundancy Ø Remote monitoring and diagnostic capabilities Ø Proven technology with tens of millions of operating hours Ø Various Factory Protection Plans available Electrical Performance Electrical Power Output Voltage Electrical Service 600 kw 400/480 VAC 3-Phase, 4 Wire Wye
Frequency 50/60 Hz Electrical Efficiency LHV 33% Fuel/Engine Characteristics Inlet Pressure Fuel Flow (HHV) Net Heat Rate (LHV) 75-80 psig 6,840,000 BTU/hr 10,300 BTU/kWh Exhaust Characteristics NOx Emissions @ 15% O2 <9 ppmvd Exhaust Mass Flow 8.8 lbm/s Exhaust Gas Temperature 535 F Dimensions & Weight Width x Depth x Height Weight 117 x 230 x 114 in 29,400 lbs Minimum Clearances Horizontal Clearance Left Right Front Rear 60 in 0 in 65 in 80 in Certifications Ø UL 2200 Listed Ø CE Certified Ø UL 1741 Ø California Rule 21 Compliant
Broad Exhaust Fired Absorption Chiller Two stage exhaust 188RT chilled water Fuel Used - Waste form of heat directly and indirectly from a Capstone CCHP Features: Ø Oxygen Free Copper Tubes in evap Long Unit Life Ø Stainless steel Tubes in all other bundles Long Unit Life Ø Highest Vacuum standard in the Industry Long Unit Life Ø Highest COP and NPLV Lowest Operating Cost Ø PLC controls with 24/7 Monitoring Simple and easy to operate Ø Zero Maintenance Pumps No maintenance required Ø Marine water boxes with hinges Lowers cost to clean tubes Ø PLC PID control with Diagnostics Lowers operating cost Ø Factory Acceptance Test (FAT) Ensures QC and performance
Project Economics Payback Calculation Total Installed Cost Fuel, O&M, and Other Costs Initial Year 1 Year 2 Year 3 Year 4 Year 5 Year 6 Year 7 Year 8 Year 9 Year 10 $1,602,900 $309,953 $315,031 $320,210 $325,492 $330,880 $280,294 $285,900 $291,618 $297,451 $303,400 Savings/Avoided Costs Include in Analysis? Electricity Production $528,628 $549,773 $571,764 $594,635 $618,420 $643,157 $668,883 $695,638 $723,464 $752,402 Heat Cogeneration $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 Cooling $0 $143,839 $149,593 $155,576 $161,799 $168,271 $175,002 $182,002 $189,282 $196,854 $204,728 Power Quality/ Reliability $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 Financing/ Inv. Tax Credits $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 Emissions or other Credits $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 Depreciation Tax Benefit $131,438 $210,300 $126,180 $75,708 $75,708 $37,854 $0 $0 $0 $0 Total $0 $803,905 $909,666 $853,521 $832,142 $862,400 $856,013 $850,885 $884,921 $920,318 $957,130 Net Cash Flow Cumulative Cash Flow Depreciation Method ($1,602,900) $493,952 $594,636 $533,311 $506,650 $531,519 $575,719 $564,985 $593,302 $622,867 $653,731 ($1,602,900) ($1,108,948) ($514,313) $18,998 $525,648 $1,057,167 $1,632,886 $2,197,871 $2,791,173 $3,414,040 $4,067,771 MACRS 5 YR (half-yr convetion) Annual Savings (Year 1) 10 yr IRR $493,952 Operating Hours/year 31.8% Microturbine Depreciation Timeline 5 years Discount Rate 8.0% 10 yr NPV $2,149,171 Heat 0 Tax Rate 41% Payback Period [Years] 2.96 Cooling 8,585 8,585 Operating Cost Comparison (Year 1) Cumulative Cash Flow $800,000 $700,000 $5,000,000 $600,000 $500,000 $400,000 $493,952 Net Other Cost/Benefit Gas Bill $4,000,000 $3,000,000 $300,000 $200,000 $100,000 Electricity Bill Net Annual Savings $2,000,000 $1,000,000 $0 Maintenance Fuel Costs $0 Initial Year 1 Year 2 Year 3 Year 4 Year 5 Year 6 Year 7 Year 8 Year 9 ($1,000,000) Year 10 ($2,000,000) 16552 to 16572 Beaver Rd 600kW CCHP SCE TOU-8 Sep 6 2017.xlsx 1 of 1 Copyright (c) 2017 Capstone Turbine Corp Assumptions; 4% electric and 2% gas escalator, plan B 5 yr FPP, 600kW production with 188RT cooling, $4.35 fuel
Pricing Product Quantity Price Total C600S 1 $942,900 $942,900 Broad 188RT 1 $360,000 $360,000 Chiller EST Installation 1 300,000 $300,000 Total $1,602,900
Cal Microturbine, Inc. 2537D Pacific Coast Highway #146 Torrance, CA 90505 (424) 256-8225 www.calmicroturbine.com QUOTE ADDRESS George Spizzirri 806 E. Avenida Pico Ste I-313 San Clemente, CA 92673 QUOTE # 1078 DATE 09/21/2017 CATALOG NUMBER PRODUCT DESCRIPTION QTY RATE AMOUNT 600S-HD4-BU00-AL00 C600S,HPNG,DM,UL,LE,C1KC 1 942,900.00 942,900.00 Braod BE 125 188 RT Absorption Chiller with manifold 1 360,000.00 360,000.00 All Price Quotes are valid for thirty (30) days from the date of the Price Quote. Prices quoted will only be honored when a written Price Quote is signed and returned to the Company within thirty (30) days from the date of the Price Quote. No verbal pricing will be honored. 20% deposit is required upon receipt of signed Price Quote from the Client. All shipping costs are the responsibility of the Client. This Price Quote and all orders associated herewith are subject to the Company s Standard Terms and Conditions of Sale as may be attached hereto or issued by the Company. Accepted By Accepted Date
Factory Protection Plan Capstone offers an industry leading maintenance program designed to give you financial peace of mind by fixing the cost of scheduled AND unscheduled maintenance. Ø Reduces total cost of ownership Ø Predictable maintenance costs over the life of the equipment Ø Protection against expensive unscheduled maintenance repairs Ø Minimizes downtime Ø Ensures the microturbine operates at peak performance Ø Available for all microturbine systems regardless of current run hours Ø Length of contract can be tailored based on your specific needs Ø Customizable payment plans Annual price per C600, assuming over 6 thousand hours per year runtime Ø Plan B Price 56,082 Ø Plan D Price 85,279
Warranty Products sold by Cal Microturbine include warranties from the equipment manufacturers only. Any warranties or representations concerning the goods are those of the manufacturer and not those of Cal Microturbine. The manufacturer provides all information regarding the product. Descriptions of products are for identification only and shall not constitute any representation or warranty by Cal Microturbine. Since Cal Microturbine is the agent between the purchaser and the manufacturer the following conditions apply to warranty claims: If Purchaser discovers that such item was not as warranted by manufacturer and promptly notifies Cal Microturbine thereof, Cal Microturbine shall remedy such nonconformance by repair or replacement of the item and any affected part of the product(s). Purchaser agrees to notify Cal Microturbine, of any apparent defects in design, materials, or workmanship, prior to performing any corrective action back chargeable to Cal Microturbine. Cal Microturbine does not warrant: (a) defects caused by failure to provide a suitable installation environment for the product, (b) damage caused by use of the product for purposes other than those for which it was designed, (c) damage caused by natural disasters, (d) damage caused by unauthorized attachments or modification, (e) any other abuse or misuse by the Purchaser, including improper installation, (f) damages or premature failure caused by poor or improper setup, installation or maintenance, based on the manufacturers recommended procedures, (g) normal wear and tear, (h) consumable or wear parts. Terms 20% due ARO 80% due within 30 days of invoice Delivery 8-12 weeks from date of order
We sincerely appreciate the opportunity to provide this quote. Please do not hesitate to contact us should you have any questions. Marc Rouse Vice President of Sales Cal Microturbine (713) 304-0656 (Mobile) mrouse@calmicroturbine.com