Sliding Door WK120 Technicall Information January 2018
Project sgoal The macro requirements for the development of this project were: Slim Dimensions and weight Performance 1,000,000 life time EN61000, EN 60335 and EN 16005-2 Made in Italy Sliding Door WK120 2
Beam s Dimension 176 mm 80 mm 116 mm Sliding Door WK120 3
Technical Data Description WK-120 Aluminium Beam s dimension(mm) H 116 x 176 Power Supply 230 V~ / 50-60 Hz Maximum Power 100 watt Power Supply for Accessories 24 V=/0,5 A max Maximum Speed 1 sliding door 0,7 mt. / sec. Maximum Speed 2 sliding door 1,4 mt. / sec. Maximum Load 1 sliding door 120 kg MAX Maximum Load 2 sliding door 100 + 100 kg Type of use S3 = 100% Working Temperature -15 C / +55 C Protection Rating IP20 Opening Cycles Test 1.000.000 Cycles Certification Compliance EN61000, EN60335 compliance EN16005 Sliding Door WK120 4
The most important Strength are: WK120 s STRENGTHS Modularity Hanger guide separate with vibration-damping material. Electronic Device with Programming and function Hight Level. Double Safety Test for accessories. Compliance as EN 16005-2 Sliding Door WK120 5
The most important Strength are: WK120 s STRENGTHS Programming Display on board (removable) Simple and Intuitive Programming Different views available such as: alarm history, anomalies, door status. Don t need special tools to programming. Charge Battery Integrated PASSWORD with two different level (available only with Selector PRO) Sliding Door WK120 6
WK120 Configuration The WK120 It has been designed thinking of giving maximum modularity, therefore it is also possible to provide solutions in KIT. The groups that compose it are: Motor Gear Electronic Device Power Hanger for one door Pulley Electric Lock Battery Battery «life» Side Cover Belt (in coils) Rubber Profile (in coil) Beam and carter Power Motor Gear Electronic Device Battery Power supply connection Sliding Door WK120 7
Accessories Configuration Selector BASIC Selector PRO Reciver to 1 IN Electronic Wireless 433 Mhz Motor Gear Battery Light Power Selector BASIC Wireless 868 Mhz Electric Lock Sliding Door WK120 Charge Battery Clever 8
Layout Electronic Device CN 6 1 Start 2 Stop 3 Fotocellula 4 Radar Int. 5 Radar Ext. 6 Foto.Rall. 7 Comune 8 +VA 9 - VA CN 7 17 Int. O 18 Int. I 19 Comune CN 8 10 Test 2 11 Test 1 12 Close 13 Open 14 Comune 15 + VA 16 - VA CN 5 A B C D OPT L.D. RH 8R E B 485 F A 485 G H + VA - VA CN 1 24 AC 24 V 25 AC 24 V N M CN 4 CN 3 - Enc. A Enc. 23 Mot. Nero 22 Mot. Rosso 21 El.Blocco Sliding Door WK120 9 L I B Enc. + Enc. 20 El.Blocco
LED s Functions WK120 DL 1 Led Comunication RS 485 GREEN Normally Blink DL 8 Led IN START GREEN Normally OFF DL 12 Led IN STOP RED Normally ON DL 11 Led IN Foto switch 1 RED Normally ON DL 9 Led IN RESET HW YELLOW Normally ON DL 3 Led IN Master/ Slave GREEN Normally OFF DL 7 Led IN RADAR IN. GREEN Normally OFF DL 6 Led IN RADAR OUT GREEN Normalmente SPENTO DL 10 Led IN Foto switch 2 RED Normally ON DL15 Led Motor Power supply BLU Normally ON DL 5 Led IN CLOSE GREEN Normally OFF DL 4 Led IN OPEN GREEN Normally OFF 10
DISPLAY s Functions If power has been inserted the administration password (see special settings with a password), you can see more detail information in real time: POSE Door Position (in encoder counts) CORS Learning Stroke (in encoder counts) RALA Approach Learned open space (in encoder counts) RALC Approach Learned close space (in encoder counts) UBAT Battery power (volt) IMOT Instantaneous Power (1/100 ampere) if the door working. Maximum power last working if the door stay stop. UMOT Motor Tension ( volt) SOGO Obstacle current threshold ( 1/100 ampere) UERR Are automatically displayed in intervals of seconds. The codes of the last 16 errors that occurred, the most recent numbers from 1 to 16 the oldest. TEMP Temperature in degrees centigrade of electronic device power. VACC Voltage of the accessories. AUTS Displays this information each time you changed the parameters of the electronic device and the two successive cycles will be used to re-check all parameters. P1 ESC P2 OK After 60 seconds of inactivity, the display returns to the operating mode. pressing the + button you can temporarily display the weight class currently configured. Sliding Door WK120 11
Standard Function Normally the display shows, at intervals of 5 seconds or so, the operating mode currently set by the selector: bdir - Automatic two-way FrEE - Free rint - Exit rest - Entry (*) APAr - Partial Opening (*) bloc - Night Lock OPEn - Open FArM - Farmacy P1 ESC P2 OK Sliding Door WK120 12
Adjustable Parameters The WK120 electronic board performs self-learning the complete setting of the door, although, where appropriate, you can customize the following parameters: Parameters Modification Push ESC to 2 sec (earing beep): came in parameters modification. Push ESC to scroll all the parameters, with P1 and P2 you can modified. Push OK to 2 sec (earing beep) you memorize the current parameter. Push again ESC to 2 sec (earing beep): to came out to modification. P1 ESC P2 OK Sliding Door WK120 13
Adjustable Parameters N Def. Parameter Note 1 70 Open Speed mm/secondo 2 40 Close Speed mm/secondo 3 4 Open Slowdown Speed mm/secondo 4 3 Close Slowdown Speed mm/secondo 5 5 Opening Brake Numerical reference 6 4 Closing Brake numerical reference 7 50 Opening Approach Space numerical reference 8 38 Closing Approach Space numerical reference N Def. Parameter Note A 2 Rest Time Seconds B 75 % stroke partial open The Open Partial working with the RADAR and OPEN, don t working with START C 0 Kind of Electric Lock 0= One way 1= Double Way D 0 Traffic Adaptation 0= OFF 1= ON E 0 When manual Forced Doors 0= Resistance to forced 1= Open (Push and Go) 2= Free F 0 Without Power Supply 0= Continuous Working G 0 Battery Low 1= Open also in n Lock position 2= Close and Lock 3= Open only if not on Lock 4= Close but not Lock 9 12 Thrust Force on obstacle numerical reference Sliding Door WK120 14
Adjustable Parameters N Def. Parameter Note N Def. Parameter Note H 1 Motion Direction( ) (Watching the door inside) 0= Open sx 1= Open a dx R 0 Lock position if R.IN o R.OUT 0= Normally function 1= Door Close locked J 8 Wing Weith numerical reference L 0 Safety Test Photo Switch 0= No TESTING N 0 Safety Test Photo Switch 1= One accessory slowdown TESTING O 0 Safety Test STOP 2= Two accessories TESTING P 0 Battery 0= No installed 1= Installed T 0 FARMACY position 0= Partial Open (about 150 MM) U 0 Time open START 0= Step by Step From 1 to 9 in dozen of seconds V 0 Delay LOCK status 0= Immediately From 1 to 9 in dozen of seconds Y 0 Doors Interlock / Emergency Open 0= no working 1= working 2= Open in case of emergency Sliding Door WK120 15
Anomalies Reports Error Description E 101 Detected obstacle to closing. The door continuous operation. E 09 Load detected more than the maximum allowable. The electronic device try to restart working only after reset or power off. E 201 Detected obstacle to closing and stop encoder. The door continuous operation. E 10 Detected the motor current more than the maximum allowable. The electronic device try to restart working only after a new start. E 102 Detected obstacle to opening. The door continuous operation. E 11 Overload the power circuit. The electronic device try to restart working E 202 Detected obstacle to opening and stop encoder. The door continuous only after a new start. operation. E 12 Memory EEPROM error. The electronic device try to restart working only E 03 Encoder failure. The electronic device stop to function and try to after reset or power off. E 04 E 05 normally function only after reset or power off. Black out. The electronic device working based on how to set the parameter F. Battery low. The electronic device working until the battery have power. E 13 E 14 E 15 E 16 Safety test 1 failed photo Switch Safety test 2 failed photo Switch Safety test 1 failed photo Switch Slowdown Safety test 2 failed photo Switch Slowdown E 06 Learning stroke more than the maximum allowable. ( stroke max mm E 17 Safety test 1 failed STOP xxxx). The electronic device try to restart working anly after reset or E 18 Safety test 2 failed STOP power off. E 19 Over-temperature power electronics. The electronic device try to restart E 07 Battery without power. The electronic device no working. working only after reset or power off. E 08 Motor polarity or encoder channel inverted. The electronic device no function and try to restart working only after reset or power off. Sliding Door WK120 16
Electronic instructions NOW, with the instructions, we see what are the first steps for the start up of the WK120 and it s functions. Click HERE Or See the PDF in attach Sliding Door WK120 17
Electronic instructions Sliding Door WK120 18
Electronic instructions Sliding Door WK120 19
Electronic instructions Sliding Door WK120 20
Electronic instructions Sliding Door WK120 21
Electronic instructions Sliding Door WK120 22
Electronic instructions Sliding Door WK120 23
Electronic instructions Sliding Door WK120 24
Safety Device EN16005 Sliding Door WK120 25
Safety Device EN16005 Sliding Door WK120 26
Electronic instructions When you have finish the connections, the leds must be in this condition Sliding Door WK120 27
Selettore BASIC Selector BASIC s functions Click HERE Or See the PDF in attach Sliding Door WK120 28
Selettore PRO Selector PRO functions Click HERE Or See the PDF in attach Sliding Door WK120 29
Scheda 1 Ingresso 433 Mhz Electronic board 1 ENTRY functions Click HERE Or See the PDF in attach Sliding Door WK120 30
Thanks for your attention