Schedules 1 to 4, Lot B: Extension of the Lessos Substation

Similar documents
NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal)

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

SWITCHGEAR DIVISION PRODUCT PROFILES

132/11 kv, 25 MVA MOBILE SUBSTATION

CPG.0 Single busbar gas-insulated cubicles

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Key features. DESIGNS: - Conservator type - Hermetically sealed

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

Figures obtained from schedules by line of business - see highlighted numbers on each schedule

MOBILE SUBSTATION GUIDE

Appendix 11 RETURN TO APPENDICES LIST. High Voltage Power Supply Upgrade (Welcon Technologies Pty Ltd)

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Unified requirements for systems with voltages above 1 kv up to 15 kv

B kv Gas-insulated Substations

Gas Insulated Metal-clad Switchgear, HMGS!

Medium-Voltage Switchgear and Switches

2 Unit Petrol Engine Spare parts kits for 4 WD Nissan Patrol

Modular integrated transportable substation (MITS)

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal)

Chapter 6 Generator-Voltage System

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

III. Substation Bus Configurations & Substation Design Recommendations

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

EDS SUBSTATION LVAC SUPPLIES

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Burns & McDonnell ISU Senior Design Project 2010/2011

Metal Clad Switchgears

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

C1000 Series Automatic Cap Bank

University of Houston Master Construction Specifications Insert Project Name

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Pretest Module 29 High Voltage Unit 1

33KV INDOOR SWITCHGEAR

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

B kv T&D GAS INSULATED SWITCHGEAR

Air-insulated switchgear UniGear type ZS1

Gas Insulated Switchgear

Generation Interconnection Facilities Study For

Ed rev.0 CATALOGUE SWITCHGEAR 2015

Customer Substation Manual

PRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)

OEB's Appendix 2-B: Fixed Asset Continuity Schedule

NP NLH NLH General Rate Application Page 1 of 1

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Page 1 of 5. Project : CATERPILLAR CM GENSETS PROJECT (RADIATOR COOLING) 2 x 16CM32, 6.3 kv, 50 Hz. TUS(S)PL Supply. Customer Supply DESCRIPTION

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Table of Contents 1. SCOPE Toronto Hydro Requirements Enclosed Switchgear Ontario Electrical Safety Code SI Units..

Publication No.: PSG

Metal Clad VCBs ~ Mk1

CP Automatic capacitor bank

EMPAC Metal enclosed capacitor bank for wind applications

SUBSTATION DESIGN TRAINING

Rex Healthcare Medium Voltage System Presentation APEC 2015 March 15-19, 2015

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

PRAGATI ENGINEERING COLLEGE

COMPACT SUBSTATION GUIDE

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

BGE STRATEGIC CUSTOMER ENGINEERING

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

SPEN, Rasmus Larsson, High Voltage Breakers Innovative breaker solutions Substation design

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Medium Voltage Metal-Enclosed Switches

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

E-12 Low-voltage Switchboard

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate

NXPLUS C Single busbar. Maintenance-free for lifetime

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Design Standard. Capacitor Bank. Detailed specifications follow. PART 1 - GENERAL

MASTERCLAD Metal-Clad Indoor Switchgear

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Switchgear Skid, C1192

UniGear. Technical Guide

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

AIR CORE REACTORS. Phoenix Electric Corporation

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

PIX-H Metal-clad switchgear up to 17.5kV

Medium Voltage Metal-Enclosed Switches

Product Specification

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV).

MAIN INCOMER -1 (500 KVA TRF.)

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

Transcription:

1.0 LIGHTNING ARRESTORS 1.1 ZNO lightning arrester, 192 kv rated voltage, 10 ka nominal discharge current 2.0 CAPACITIVE VOLTAGE TRANSFORMER ea. 45 2.1 220 kv capacitive voltage transformer 220/ 3 / 0.11/ 3 / 0.11/ 3 6 3.0 DISCONNECTOR 3.1 220 kv, 1250 A, center-break, 3-phase, disconnect switch, with drive mechanism for manual gang and motor operation 3.2 Line disconnector, outdoor, center break type, 3-pole, 220 kv, 50 Hz, 1250 A, with drive mechanism for manual gang and motor operation and with manually operated 3-phase earthing switch; 3.3 Shunt capacitor disconnector, outdoor, center break type, 3-pole, 220 kv, 50 Hz, 1250 A, with drive mechanism for manual gang and motor operation and with manually operated 3-phase earthing switch 3.4 Shunt reactor disconnector, outdoor, center break type, 3-pole, 220 kv, 50 Hz, 1250 A, with drive mechanism for manual gang and motor operation ea. 30 ea. 9 4.0 CURRENT TRANSFORMER 4.1 220 kv current transformers, outdoor, 400-800/1/1/1/1/1 A ea. 123 5.0 CIRCUIT BREAKER 5.1 220kV, outdoor SF6 circuit-breaker, 1250 A, 31,5 ka ea. 14 5.2 220kV, SF6 circuit-breaker, suitable for switching 25 MVAR, 220 kv shunt capacictor bank 6.0 POWER TRANSFORMER 6.1 220/132/11 kv, 90 MVA 3-phase power transformer; includes shunt reactor 15 kv / 15 MVAr 7.0 SHUNT CAPACITOR BANK 7.1 220 kv, 25 MVAr shunt capacitor bank, internally fused, 3-phase, earthed. It includes three damping reactors and three unbalance current transformers 8.0 SHUNT REACTOR 8.1 220 kv, 10 MVAr shunt reactor; it includes current transformers for each bushing: primary 75/1A and 300-600/1/1 A; and secondary 300-600/1/1 A. Also a neutral reactor will be provided 9.0 RIGID BUS SYSTEM AND INTERCONNECTION OF ELECTRICAL EQUIPMENT 9.1 220 kv strain insulator string ea. 132 9.2 220 kv suspension insulator string ea. 48 9.3 220 kv post insulator string ea. 69 9.4 Aluminium stranded conductor for Bus Bar 9.5 220 kv, 1000 A Bus work, disc insulators and hardware 9.6 220 kv, 800 A Bus work, disc insulators and hardware SUB TOTAL, PAGE 1, CARRIED TO SUMMARY Bidder's stamp and signature Page 1 of 5

10.0 COMMUNICATION SYSTEM 10.1 Fiber optical Transmitter and Receiver PDH / SDH with all required functions 10.2 Optical amplifier / booster 10.3 Fiber optic cable from Tororo 220kV line gantry to control room 10.4 Digital telephone exchange ea. 1 10.5 Digital distribution frame 10.6 All required Telephone and data interfacing equipment 10.7 Normal subscriber set, desk type, indoor 10.8 Normal subscriber set, wall type, outdoor weatherproof 10.9 Telephone cable with accessories 10.10 Low voltage cables and all required installation material 10.11 Connecting hardware, clamps and accessories lot 2 10.12 Required supporting steel structures 10.13 Equipment not included in above but considered essential for complete installation and all interfacings. Provide details in a separate sheet 11.0 TERMINAL CABINET 11.1 Cabinets complete with auxiliary devices and terminal blocks 4 12.0 CONTROL AND RELAYS PANELS Control Panels 12.1 Panel No. 1: 220/132 kv, Autotransformer-Circuit No. 1 ea. 1 12.2 Panel No. 2: Turkwell 220 kv Incoming Line Circuit ea. 1 12.3 Panel No. 3: 220/132 kv Autotransformer Circuit No. 2 ea. 1 12.4 Panel No. 4: Olkaria 220 kv Incoming Line No. 1 ea. 1 12.5 Panel No. 5: Olkaria 220 kv Incoming Line No. 2 ea. 1 12.6 Panel No. 6: Kisimu 220 kv Incoming Line ea. 1 12.7 Panel No. 7: Kisimu 220 kv Incoming Line ea. 1 12.8 Panel No. 8: Shunt Capacitor Circuit No. 1 ea. 1 12.9 Panel No. 9: Shunt Capacitor Circuit No. 2 ea. 1 12,10 Panel No. 10: Tororo 220 kv Incoming Line and Shunt Reactor Circuit No. ea. 1 1 12,11 Panel No. 11: Tororo 220 kv Incoming Line and Shunt Reactor Circuit No. ea. 1 2 12,12 Panel No. 12: 220/132 kv, Autotransformer-Circuit No. 3 ea. 1 12,13 Panel No. 13: 220/132 kv, Autotransformer-Circuit No. 4 ea. 1 12,14 Panel No. 14: Future ea. 1 12,15 Panel A: Eldoret 132 kv Outgoing Line Circuit ea. 1 12,16 Panel B: Kabarnet 132 kv Outgoing Line Circuit ea. 1 Relay Panels 12,15 Incoming Line Bay Circuit Relay Panels ea. 14 12,16 Line Shunt Reactor Bay Circuit Relay Panels ea. 4 12,17 Main Bus Bay Circuit Relay Panel ea. 4 12,18 Main Shunt Capacitor Bus Bay Circuit Relay Panel 12,19 Shunt Capacitor Bank Bay Circuit Relay Panel ea. 4 12,20 220/132 kv, Autotransformer Circuit Relay Panel ea. 8 12,20 132 kv Outgoing Line Circuit Relay Panel ea. 4 13.0 DIGITAL CONTROL AND MONITORING SYSTEM 13.1 Common Equipment 13.2 Furniture 14.0 MODIFICATION TO OUTDOOR SWITCHGEAR 14.1 Re-route 33 kv Feeders ( Fluospar-Kabarnet 1 and Eldoret No. 2) No. 1 15.0 ADDING TO 132 kv SECTION 15.1 ZNO lightning arrester, 120 kv rated voltage, 10 ka nominal discharge ea. 12 current 15.2 132 kv, 1250 A, center-break, 3-phase, disconnect switch, with drive ea. 8 15.9 mechanism for manual gang and motor operation 15.3 Line disconnector, outdoor, center break type, 3-pole, 132 kv, 50 Hz, 1250 ea. 4 A, with drive mechanism for manual gang and motor operation and with manually operated 3-phase earthing switch; 15.4 132 kv current transformers, outdoor, 300-600/1/1/1/1/1 A ea. 12 15.5 132kV, outdoor SF6 circuit-breaker, 1250 A, 31,5 ka ea. 4 15.6 132 kv, capacitive voltage transformer ea. 6 132 / 0,11 / 0,11 kv 3 3 3 Bidder's stamp and signature Page 2 of 5

15.7 Aluminium alloy tube for 132kV busbar 15.8 132kV set of bus supports, couplers, conductors, clamps, connectors and fittings 15.9 Terminal cabinet for added 132 kv section complete with auxiliary devices ea. 4 and terminal 16.0 GALVANIZED STEEL STRUCTURES 16.1 Steel fabricated structure for 220 kv line termination intermediate gantries and switchyard bus support 16.2 Steel fabricated structure for shield wire tower and switchyard lightning support 16.3 Steel fabricated structure for 132 kv equipments support to transformer bays and outgoing line bays. SUB TOTAL, PAGE 2, CARRIED TO SUMMARY Bidder's stamp and signature Page 3 of 5

17.0 RTU / SCADA INTERFACE PANEL 17.1 RTU Panel with all required communication interfaces and all cabling and connecting for auxiliary services 17.2 Cross connection panels, including battery power supply, all cabling connection and all other works neccesary 17.3 All necessary arrangement to integrate the SCADA and telecommunication equipments to the existing systems, including necessary data engineering, software and hardware upgrading. supply set 1 set 1 18.0 SUBSTATION GROUNDING 18.1 Cable, rods, conductor, connectors and hardware 18.2 Portable maintenance earthing cables, 3 phase set set 2 19.0 SHIELD WIRE SYSTEM 19.2 Conductor (high tensile strength galvanized steel), Clamps and Hardware, etc 20.0 AC & DC AUXILIARY SERVICES 20.1 11 kv indoor Metal-Clad switchgear; include: capacitor bank, earthing transformer, and feeder to auxiliary services 20.2 Auxiliary transformer, 100 kva, 11 / 0,415-0,23 kv pad mount dry type transformer 20.3 Auxiliary transformer, 100 kva, 33 / 0,415-0,23 kv pole mounted type transformer 20.4 415 V distribution switchboard, include 3 main circuit breakers with mechanical and electrical interlocks to 3 auxiliary supplies 20.5 150 KVA 415/230 V emergency diesel generating set with 450 liters fuel tank 20.6 400 V emergency supply panel with automatic transfer switch 20.7 110 V cc, 220 A-hours NiCad batteries e.a. 2 20.8 48 V cc, 220 A-hours NiCad batteries 20.9 Dual 110 V NiCad battery charger e.a. 2 20.1 Dual 48 V NiCad battery charger 20,11 110 Vdc emergency lighting 21.0 MISCELLANEOUS 21.1 Switchyard lighting and power outlets 21.2 33 kv and 11 kv Power cables 21.3 Control and signaling cable 21.4 Low voltage cable 21.5 Steel or plastic conduit and cable tray 21.6 Supply of Embedded steel parts 21.7 Boxes for padlocks and keys 22.0 CIVIL WORKS 22.1 Site clearance, demolitions, levelling and ground stabilisation (including retaining walls, slope protection) and final surfacing and gravelling 22.2 Geotechnical Investigations 22.3 Control building to serve space for auxiliary transformer, diesel generator, communication functions, control functions, toilet, shower and storage 22.4 Fencing and gates 22.5 Switchyard equipment foundations and embedded parts 22.6 Cable ducts, cable trenches and duct covers 22.7 External access road 22.8 Storm water drainage system and spillage wastes disposal system 22.9 Drainage system 22.10 Draw out and earthing pits 22.11 Fresh water reticulation system for substation supply 22.12 Septic tank and disposal syastem 22.13 Relocation of the bore hole and the water tank 22.14 Parking and internal access roads 23.0 MODIFICATION TO 132 KV AREA SWITCHYARD 23.1 Installing of 11 kv Feeder of the pole mounted auxiliary transformer 24.0 LINE TRAP FOR EXISTING 220 kv TURKWEL LINE Bidder's stamp and signature Page 4 of 5

24.1 PLC (Power Line Carrier) Line trap consist of a main coil and turning device. Line trap should have same characteristics as the existing dismantled one. e.a. 2 SUB TOTAL, PAGE 3, CARRIED TO SUMMARY Bidder's stamp and signature Page 5 of 5