Test Sample Description Catalog Number: Description:

Similar documents
Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description:

Test Sample Description Catalog Number: Description:

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE:

S BERGIN R BEATTIE Lighting Engineer. Checked Approved

PHONE: (303) FAX: (970) WEBSITE:

PHONE: (303) FAX: (303) WEBSITE:

PHONE: (303) FAX: (970) WEBSITE:

LED Black Housing High Output Remote Capable

NVLAP LAB CODE:

NVLAP LAB CODE:

Number Eight Lighting Company 803/K2-HI-15-XX/DIM /FS-P-1-WH

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Calibration Due Date Chroma Programmable AC Source 61604

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

LEN Series 2x2 / 2x4 LED

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA

Report of Test LLIA

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Report of Test LLIA

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Maxlite Jersey Blvd Rancho Cucamonga, CA 91730

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MaxLite 12 York Ave. West Caldwell, NJ.

IES INDOOR REPORT PHOTOMETRIC FILENAME : LHB K-U80-UNI.IES. DESCRIPTION INFORMATION (From Photometric File)

PHOTOMETRIC TESTING & EVALUATION. Sample Tested Man-D-Tec UNILED-12-4K. Prepared for: Man-D-Tec 8175 E. Paradise Lane Scottsdale, AZ 85260

Report of Test LLIA

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

PHONE: (303) FAX: (970) WEBSITE:

Calibration Due Date Chroma Programmable AC Source 61604

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

IES INDOOR REPORT PHOTOMETRIC FILENAME : C6R UNVE5-35-LG.IES. DESCRIPTION INFORMATION (From Photometric File)

IES INDOOR REPORT PHOTOMETRIC FILENAME : 4A_ASD-LVP10M-4N3135-PRM_IES.IES. DESCRIPTION INFORMATION (From Photometric File)

Report of Test LLIA

Report of Test LLIA A

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

IES INDOOR REPORT PHOTOMETRIC FILENAME : VW4-LED48DMVSSF50.IES. DESCRIPTION INFORMATION (From Photometric File)

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

LIGHT EFFICIENT DESIGN

LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL LED Luminaires

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name:N/A) 188 S. Northwest HighwayCary, IL60013.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE Fixture is tested with no special conditions.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

LM Test Report. LIGHT EFFICIENT DESIGN (Brand Name:N/A) LED Luminaire

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

LIGHT EFFICIENT DESIGN, LLC

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York AveWest Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

Lighting Sciences

NVLAP LAB CODE LM Test Report. For REMPHOS TECHNOLOGIES LLC. (Brand Name: ) 90 Holten St, Danvers, MA 01923,USA.

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report For. Model Different: All construction and rating are the same, except CCT

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

Report of Test LLIA A-R01*

NVLAP LAB CODE LM Test Report. For SNC OPTO ELECTRONIC CO.,LTD. (Brand Name: SNC LED)

LIGHT LABORATORY, INC E Kaiser Blvd. Anaheim, CA 92808

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Report of Test LLIA A

Report of Test LLIA A

Report of Test LLIA A

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Photometric Test Report. MaxLite Inc 10 York Avenue, West Caldwell, NJ Ramesh Raghavan, x146,

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: N/A) 12 York Ave, West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite lnc. (Brand Name: MaxLED) 12 York Ave West Caldwell NJ 07006,USA

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

INDEPENDENT TEST LABORATORY REPORT No

INDEPENDENT TEST LABORATORY REPORT No

Report of Test LLIA

NVLAP LAB CODE LM Test Report. For. MLS CO., LTD (Brand Name: MLS) NO.1 MULINSEN RD XIAOLAN TOWNSHIP ZHONGSHAN, GUANGDONG CHINA

INDEPENDENT TEST LABORATORY REPORT No A

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LED Stairwell Fixture

Report of Test LLIA A

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDUCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

T8 4ft 5000K EazyLux EZ8450D7R07

Report of Test LLIA

Report of Test LLIA A-R02*

USTE, dba Vista Professional Outdoor Lighting Surveyor Ave., Simi Valley CA 93063

NVLAP LAB CODE LM Test Report. For IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA 92503

Catalog Number UPC Number Features. General Lumen Output: 2300 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Report of Test LLIA A

Photometric Test Report. Overdrive Electronics Pvt. Ltd C-121, Hosiery Complex, Phase2 Extn. Mohit K Mittal, ,

Catalog Number UPC Number Features. General Lumen Output: 800 Color Temperature: 5000K Cool White CRI: 70+ Housing Color: Black

Transcription:

Project Number Date 17.00221 1/24/2017 LAB 6 Test Sample Description Catalog Number: Description: P350055-00930 1-Lt. DCLED Flush Mount Test Method: Preburn Time: Time To Stabilize: Total Operating Time: Input Voltage (Volts) : Input Current (Amps) : Input Wattage (Watts) : Ambient Temp ( C) : IES LM-79-08 10 0:30 0:55 2:15 120.1 0.167 19.8 25.6 Hubbell Lighting, Inc. 701 Millennium Boulevard Checked: Approved: M.ELLMANN D. BLACK TESTING NVLAP LAB CODE: 201003-0 This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Page 1 of 8

REPORT NUMBER: 17.00221 LUMINAIRE: 1-Lt. DCLED Flush Mount LAMP: 20- Nichia 3000K LEDs REFRACTOR: Etched White Linen MOUNTING: Ceiling NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED. PAGE: 2 OF 8

REPORT NUMBER: 17.00221 PAGE: 3 OF 8 DEG CANDELA LUMENS 0 231 5 230 22 15 222 63 25 208 96 35 187 117 45 160 124 55 131 117 65 100 99 75 71 76 85 48 52 90 38 95 30 34 105 27 29 115 32 31 125 33 30 135 31 24 145 26 17 155 21 10 165 15 4 175 12 1 180 12 ZONAL LUMEN SUMMARY ZONE LUMENS %FIXT 0-30 180 19.1 0-40 297 31.5 0-60 538 56.9 0-90 765 81.0 90-120 94 10.0 90-130 124 13.1 90-150 165 17.4 90-180 180 19.0 0-180 945 100.0 EFFICACY = 47.7 lm/w CIE TYPE - SEMI-DIRECT LUMINAIRE SPACING CRITERION = 1.28 80 160 240 90 75 60 45 0 15 30

REPORT NUMBER: 17.00221 PAGE: 4 OF 8 LUMINOUS DIAMETER: 12.000 HEIGHT OF SIDE : 3.000 LUMINANCE DATA IN CANDELA/SQ M ANGLE AVERAGE IN DEG 45 2352. 55 2152. 65 1927. 75 1718. 85 1627.

REPORT NUMBER: 17.00221 PAGE: 5 OF 8 CANDELA DISTRIBUTION 0.0 231 5.0 230 10.0 227 15.0 222 20.0 216 25.0 208 30.0 198 35.0 187 40.0 174 45.0 160 50.0 146 55.0 131 60.0 115 65.0 100 70.0 85 75.0 71 80.0 59 85.0 48 90.0 38 95.0 30 100.0 27 105.0 27 110.0 29 115.0 32 120.0 33 125.0 33 130.0 33 135.0 31 140.0 29 145.0 26 150.0 24 155.0 21 160.0 18 165.0 15 170.0 13 175.0 12 180.0 12

REPORT NUMBER: 17.00221 PAGE: 6 OF 8 5-DEGREE ZONAL LUMEN SUMMARY 0-5 6 5-10 16 10-15 27 15-20 36 20-25 44 25-30 51 30-35 57 35-40 60 40-45 62 45-50 62 50-55 60 55-60 57 60-65 52 65-70 47 70-75 41 75-80 35 80-85 29 85-90 24 90-95 19 95-100 15 100-105 14 105-110 15 110-115 16 115-120 16 120-125 15 125-130 14 130-135 13 135-140 11 140-145 9 145-150 7 150-155 6 155-160 4 160-165 3 165-170 2 170-175 1 175-180 0 10-DEGREE ZONAL LUMEN SUMMARY 0-10 22 10-20 63 20-30 96 30-40 117 40-50 124 50-60 117 60-70 99 70-80 76 80-90 52 90-100 34 100-110 29 110-120 31 120-130 30 130-140 24 140-150 17 150-160 10 160-170 4 170-180 1

REPORT NUMBER: 17.00221 PAGE: 7 OF 8 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 115115115115 110110110110 101101101 92 92 92 85 85 85 81 1 102 97 92 88 98 93 88 84 85 81 78 78 75 72 71 69 67 64 2 92 84 76 70 88 80 73 68 73 68 63 67 63 59 61 58 55 52 3 84 73 64 57 80 70 62 56 64 58 52 59 53 49 54 49 46 43 4 77 64 55 48 73 62 53 47 57 50 44 52 46 41 48 43 39 36 5 70 57 48 41 67 55 46 40 51 43 38 47 40 36 43 38 34 31 6 65 51 42 36 62 49 41 35 45 38 33 42 36 31 39 33 29 27 7 60 46 37 31 57 45 36 30 41 34 29 38 32 27 35 30 26 24 8 56 42 34 28 53 41 33 27 38 31 26 35 29 24 32 27 23 21 9 52 38 30 25 49 37 29 24 35 28 23 32 26 22 30 25 21 19 10 49 35 28 22 46 34 27 22 32 25 21 30 24 20 28 23 19 17 ALL CANDELA, LUMENS, LUMINANCE, AND VCP VALUES IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY. THE COEFFICIENT OF UTILIZATION VALUES ARE BASED ON THE TOTAL ABSOLUTE LUMEN OUTPUT OF THIS TEST SAMPLE.

Project Number Date 17.00221 1/24/2017 Goniophotometer Calibration Calibration Lamp : GE 1000W, 120V, T6, CL (FEL) Lamp Number: ITL78966-1000-38 Calibration Current: 8.300 Amps DC Total Luminous Flux: 25889.0 Lumens Calibration Date: 09/02/2016 Test Equipment Used Instrument Goniophotometer Power Analyzer Power Source Thermometer Manufacturer / Model ITL / HLI LAB 6 - Test Distance: 31.3' Yokogawa / WT 332 Voltage-Regulated House Power National Instruments / USB-TC01 S/N N/A C2QA27076V N/A 1912745 Calibration Due: N/A 11/2/2017 N/A 11/2/2017 Hubbell Lighting, Inc. 701 Millennium Boulevard This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Page 8 of 8