GRIDCON ACF ESS GREAT COMBINATION ACTIVE FILTER AND ENERGY STORAGE.

Similar documents
POWER QUALITY SOLUTIONS FOR INDUSTRIAL AND DISTRIBUTION GRIDS. W WW.R EINHAU S EN.COM

Power Quality innovative SolutionS for industrial and distribution grids.

POWER QUALITY SOLUTIONS FOR INDUSTRIAL AND DISTRIBUTION GRIDS. W WW.R EINHAU S EN.COM

Energy Storage System (ESS) Renewable energy supply with next generation technology

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

Renewable energy supply with next generation technology

ABB central inverters PVS to 1000 kw

Magellan Utility Scale Energy Storage

ABB central inverters PVS to 1000 kw

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

sun systemizer High-performance battery storage for a safe power supply

The modular energy storage system for a reliable power supply

Power conversion systems for energy storage. Engineering that stores

Three Phase UPS Systems Range: 10 to 500kVA

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

L kw Distributed Energy Storage System Unit (SU50)

Technical Data Sheets

VACUTAP RMV-II HIGHEST STANDARD IN ON-LOAD TAP-CHANGERS. IMPRESSIVE BY DESIGN. TRANSFORMER CONTROL

Industrial PFC UPS System

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

SolarMax P series The power package for residential solar plants

Technical Data Sheets

Application. Battery. Public Grid GS HYBRID INVERTER

Technical Data Sheets

MX1S Matrix Converter

SolarMax MT A series A reliable solution for commercial PV applications

INVEOR "Smart connections." on five levels

Energy Storage System for Home

RENEWABLE ENERGY SOLUTION

Energy Storage System for Home. High Efficiency - Peak efficiency 97.3% Bi-directional DC-DC converter

PQstorI One stop solution for energy storage and power quality

ENERGY STORAGE SYSTEM MERUS ESS

Power Conversion System The Best Technology for your photovoltaic and storage system

SOLON SOLiberty Energy Storage Solution. Greater Independence Through On-site Consumption.

Technical Data Sheets

APS-PV-Series 1000 V DC

Use your own grid. green energy. Storage systems for intelligent energy supply. GENERATE STORE UTILISE

ABB central inverters ULTRA-750/1100/ kW to 1560kW

Solar inverter AX-series

FINHRM FINHRM5 FINHRMA FINHRMAC

E l ower. Inverters for renewables RENEWABLE SOURCES. elettronica di otenza

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

Dynamic DC Emulator Efficient testing of charging technology and power electronics

Sungrow-Samsung SDI ESS Solutions. April 12, 2017

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

BYD Battery Energy Storage Solution. BYD Design Center

Magellan Stand Alone Power System (1P) Magellan Renewables Range

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

Technical Data Sheets

MGE TM Galaxy TM 7000 GFC

TECHNICAL DATA SHEET KVA UPS Systemss

High performance Vector Control. Ratings. System configuration

Technical Data Sheets

Versatile and Powerful. Liduro Wind Frequency Converter System

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

WG5Kxxx Modular DC-converter system

ABB Power Electronics - February 8, IEEE PES meeting in Chicago BESS Overview - Components, Drivers, Applications

photovoltaikforum.com

Technical Data Sheets

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

D Series: UPS UPTO - 300KVA - Three / Three Phase

MERU Solar Off-Grid Inverters

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

SolarMax MT series The all-rounder for trade and industry

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Power Conditioning of Microgrids and Co-Generation Systems

Development of the Single Phase PV Inverter SANUPS P61A

THE ENERGY STORAGE EXPERTS

Power Conversion System for ESS 100 kw to 30 MW Bi-directional Inverters

APS-ES-Series 1000 V DC

Standardized and modular scalable from 30 kw up to several MW. Plug-and-play integration of renewable energy in off-grid and ongrid applications

POWER kva

SINAMICS GM150 IGCT version

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification

P H O T O V O LTA I C

POWER kva

3 Phase Power Systems - Designed for Canada

PPT EN. Industrial Solutions

Mia Sylvester Technical Sales Advisor Fronius UK FRONIUS PV STORAGE SOLUTION TRAINING

Magellan Stand Alone Power System (3P) Magellan Renewables Range

500 / 630 / 720 / 760 / 800 / 850 / 900

Energy Storage Solution for microgrids. from 33 kva to multiple MVA

TripleLynx Inverter Range MAKING MODERN LIVING POSSIBLE. The benchmark solar inverter from Danfoss 3 phase Transformerless 8, 10, 12.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

ASC SWITCHBOARD DATA SHEET

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

New Central Grid-tied PV Inverters. 500kW/1MW 3-level T-type modular inverters 1MW/2MW PV power containers

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Transcription:

GRIDCON ACF ESS GREAT COMBINATION ACTIVE FILTER AND ENERGY STORAGE. WWW.REINHAUSEN.COM SAMSUNG ESS INSIDE 1

GRIDCON ACF ESS 2

ENERGY STORAGE SYSTEMS IMPROVE FLEXIBILITY. Energy storage systems are an attractive solution in all situations where energy supply and consumption need to be made synchronous or asynchronous. New technologies in the fields of inverters, storage cells, and capacitors are making ever more comprehensive and cost-effective forms of use possible. In principle, the storage of electrical energy is nothing new. For decades pump storage power plants have converted energy between electrical and potential energy, greatly boosting grid stability. They allow thermal power plants to generate constant electric power at a favorable operating point regardless of actual demand for energy. Instead of potential energy, new kinds of energy storage systems use chemical, kinetic or electric accumulators to influence the ratio of consumption to supply. They tap into the advances being made in material science and power electronics and, compared with pump storage power plants, their benefits include the ability to be scaled up to large sizes, the fact that they do not need a local water supply, and the dynamism with which they can take in and give out energy. Energy storage systems are used in public, industrial, and private grids. In public grids they are especially relevant when renewable sources of energy are integrated, because they are able to take in energy generated by the sun or wind if there is not sufficient load for this energy to be consumed directly at that time. They thereby allow solar power to be used at night and wind power to be used during periods of calm weather. If energy storage systems are installed locally in public grids, they also help to reduce the extent to which the grid has to be extended when renewable sources of energy are added. This is because they can locally balance excess supply or demand and energy does not therefore have to be transported over long distances. Depending on the power electronics used, energy storage systems can also help to improve or stabilize the power quality in public grids. In industrial grids, energy storage systems help to optimize energy costs. They reduce peak loads, level out energy consumption, and optimize the management of in-house generation systems, such as PV and CHP. What s more, they generate income, which can be offset against energy costs by flexibly offering excess energy to the frequency control market. Using special emergency power or UPS functions, they can also help to stabilize industrial processes and improve availability. Finally, for private island grids, energy storage systems are of central importance for providing a continuous supply of energy with a high power quality. This is especially the case if the main sources for private island grids are volatile renewable energies. 3

GRIDCON ACF ESS EFFICIENT INVERTER ARCHITECTURE. Networked, flexible, simple. GRIDCON ACF ESS is based on an inverter architecture which has proved itself in an industrial environment and has now had an energy storage added to it. I Combination of reactive power compensation, active filter, and energy storage in one system I Modular concept for individual, applicationspecific adaptation and retrofitting I Connection voltage of up to 480 V (+/-10%) I Output range of 400 kw in one system (more possible in integrated network) I Energy storage of up to 2.4 MWh in one system (more possible in integrated network) I Existing ACF systems can be retrofitted with an energy accumulator I Energy storages using different technologies and from different manufacturers can be linked to suit the application I High levels of safety and availability thanks to an extensive protective concept at inverter level and constant modularity www TCP/IP Touch panel CCU Control Computer Unit Flexible integration into industrial networks thanks to Anybus interface DSC** IPU* IGBT Power Unit DSC** Distributed Synchronous Control MIO*** Measurement / Input / Output BMS**** Battery Management System Modbus RTU Integration of the BMS*** 4

GRIDCON ACF DC Distribution Battery Rack Fuse Contactor EMC filter LCL filter 3-level inverter DC link EMC filter Disconnector Fuse Contactor Batteries L1 L2 L3 ~ ~ 3-level technology small losses and high dielectric strength The 3-level circuit of the GRIDCON ACF ESS is based on twelve IGBTs, whereas the conventional 2-level version only has six. The special circuitry halves the voltage loads on the power semiconductors. On the one hand, this produces fewer losses and, on the other hand, enables high rectification voltages for directly connecting batteries without additional converters. Another benefit of the 3-level technology is the lower ripple of the output current compared with a 2-level architecture. Up to four measuring units (MIO***) DSC** 4 x voltage measurement 4 x current measurement 4 x digital inputs- / outputs MIO***2 MIO***3 MIO***4 Up to four battery racks per IPU* IPU* 6 IPU* 5 IPU* 4 IPU* 3 IPU* 2 SAMSUNG ESS INSIDE Up to six IPU* 125 A, 3-wire 5

GRIDCON ACF ESS VARIOUS FIELDS OF USE. Industrial power consumption without GRIDCON ACF ESS Industrial power consumption with peak shaving by GRIDCON ACF ESS Demand charges Demand charges Possible savings Savings 0:00 6:00 12:00 18:00 24:00 0:00 6:00 12:00 18:00 24:00 Peak shaving reduces energy costs Energy providers and commercial customers reach contractual agreement on a price per kilowatt. The annual energy costs incurred are therefore mainly determined by maximum load. The higher a peak load, even if if only occurs once, the higher the total annual energy costs. The more an industrial facility can reduce its maximum load, the more energy costs it can save. Energy storage systems come into play here by taking in energy if the load is below a defined maximum level and supplying energy if the load threatens to exceed the limit. Other fields of use. Increase in in-house consumption Optimization of earnings from PV, CHP, wind turbines in own grid Power leveling Adaptation of grid supply to schedules with renewable energy generation Back-up power operation Back-up power supply should the grid fail Voltage stability Stabilization of voltage in distribution grids with a high share of renewable energies USV UPS operation Improvement in security of supply Island grid operation Integration of renewable energy generators in tiny grids to reduce operating costs Primary control Primary control Balancing power available within 30 s Minutes reserve Minutes reserve Balancing power available within 15 minutes Secondary control Secondary control Balancing power available within 5 min 6

Technical Data GRIDCON ACF ESS optimized for energy Rated voltage 400 V (maximum 480 V) +/- 10% Rated frequency AC peak current AC cable connection Power loss converter Switching frequency Control System setup and display Reaction time Communication interfaces Current transformer Converter Colouring Dimensions ACF cabinet (approx. W x D x H) Cooling IP protection degree Environmental conditions 50 Hz / 60 Hz 2 x rated current 3-phase + PE, a neutral conductor is not necessary (grids: TN, TT, IT) < 2,5 % of power output in maximum, < 2,2 % at typ.operation, < 0,4 % at no load, < 100 W at standby 10 khz (low loss) Internal control-computer with two digital signal processors Via touchpanel with grafic display or internal webserver (TCP/IP) and PC no additional software necessary << 1 ms Ethernet (TCP/IP) several field-bus systems with optional Anybus plug-in modules (e.g. Profibus, Modbus) 4 x digital output (potential free, programmable) for status messages 4 x digital input (24 VDC, programmable) for external control an parameter change Either 2-phase or 3-phase current measurement, xx/5 A or xx/1 A (parameterized) Current transformers are not included, 15 VA, class 1 or better recommended 3-Level IGBT with voltage link (DC film capacitors) Standard: RAL 7035 light grey (other colors and designs on request) 800 x 600 x 2000 mm 800 x 600 x 2200 mm with optional base (needed for main air supply from front or back), without DC-coupling cabinet Standard: Air cooling with speed-controlled fans Optional: Liquid cooling with connection to external cooling system via heat exchanger unit Standard: IP20, optional: IP21.. IP54 Maximum ambient temperature without derating: 40 C Recommended ambient temperature for continuous operation: < 25 C Minimum operating temperature: 0 C, relative humidity: maximum 95% non condensing Transport / storage: -20 C.. 70 C EN 55011, class A1 (industrial environment) EMC class Standards EN 50178, EN 61439-1, EN 61439-2, EN 61000-6-2, EN 61000-6-4, EN 55011 AC voltage optimized for power with rated voltage 400 VAC optimized for energy with rated voltage 400 VAC Number of IPUs 1 2 3 4 1 2 3 4 Rated current AC 125 A 250 A 375 A 500 A 125 A 250 A 375 A 500 A Rated apparent power S 87 kva 173 kva 260 kva 346 kva 87 kva 173 kva 260 kva 346 kva Rated DC Current (continuos) 132 A 264 A 397 A 529 A 132 A 264 A 397 A 529 A Weight ca. 390 kg ca. 530 kg ca. 670 kg ca. 820 kg ca. 390 kg ca. 530 kg ca. 670 kg ca. 820 kg Technical data Example: Battery rack optimized for power Example: Battery rack optimized for energy DC voltage min. / max. 794 V / 1050 V 768 V / 964 V Rated energy E 64 kwh 152 kwh Active power P rated / max. 127 KW / 254 KW 79 KW / 108 KW C-rate / C-rate max. 2,0 / 4,0 0,5 / 0,7 Dimensions battery rack (W x D x H) 1066 x 690 x 1613 mm - with base 1069 x 687 x 2290 mm Weight 980 kg 1408 kg IP protection degree IPXO (with optional side plate and back plate) IPXO (with optional side plate and back plate) Environmental conditions Operating ambient temperature: 23±5 C; Temperature uniformity: less than 3 C recommended Operating Humidity: <85% non condensing Module Storage Temperature: -20~60 C, recommend: 25 C Technical data 1-4 battery racks per ACF ESS 1-16 battery racks per ACF ESS Rated energy E 64 kwh - 256 kwh 152 kwh - 2432 kwh Rated active power range P 87 kw - 346 kw 79 kw - 346 kw C-rate / C-rate max. Technical data Dimensions (W x D x H) 0,3 / 0,3-0,5 / 0,7 depending on combination of inverter and rack rating DC disconnector panel 400 x 800 x 2000 mm 400 x 800 x 2200 mm with optional base (needed for main air supply from front or back) Dimensions depend on individual configuration of protection devices and number of battery racks 7

LOW-VOLTAGE SOLUTIONS: Maschinenfabrik Reinhausen GmbH Power Quality Wiebestr. 46 10553 Berlin, Germany Phone: +49 30 330915-0 Fax: +49 30 330915-25 E-mail: support.pq@reinhausen.com MEDIUM-VOLTAGE SOLUTIONS: Maschinenfabrik Reinhausen GmbH Power Quality Alte Chaussee 73 99097 Erfurt, Germany Phone: +49 361 30103-0 Fax: +49 361 30103-20 E-mail: support.pq@reinhausen.com Maschinenfabrik Reinhausen GmbH Falkensteinstrasse 8 93059 Regensburg, Germany Phone: +49 941 4090-0 Fax: +49 941 4090-7001 E-mail: info@reinhausen.com www.reinhausen.com Please note: The data in our publications may differ from the data of the devices delivered. We reserve the right to make changes without notice. IN4847609/00 EN GRIDCON ACF ESS F0338500 04/16 uw Maschinenfabrik Reinhausen GmbH 2016 THE POWER BEHIND POWER.