PRODUCT INFORMATION BULLETIN

Similar documents
MAXIGARD A2000 SPEED SWITCH. Introduction

Operations Manual. Zero Speed Switch Sensor Model ZS09P

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

AA4006 Speed Sensitive Trip Unit. User Manual

LTX RF LEVEL SENSOR. Instruction Manual

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Bulletin 871P Can Sensors

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

PRO REMOTE Series CAPACITANCE PROBE

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

Shaft Speed Switches. SCP Series Speed Switch. M Series Speed Switch M100T/M5000T. Our Most Popular Speed Switch!

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller.

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Model 550 Series Vibration Switches

ES52. Auto Start Engine Controller. Full Version. Installation and User Manual for the ES52 Auto Start Engine Controller.

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ENGINE GOVERNING SYSTEMS

PRO REMOTE 25 LV CAPACITANCE PROBE

Electric Actuator Instructions

ESC2301. Universal Electronic Governor Controller Operation Manual

CP (Vdc) CP (Milliamp) CP (Slidewire)

5001TCP SPEED CONTROLLER

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

EG3000. Generator Electronic Governor Controller Operation Manual

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

C3000 SIGNAL TRANSMITTER. Introduction

ESD5550 / 5570 Series Speed Control Units

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

EG1065X. Compatible with Barber Colman* Dyn1-1065X series * Use for reference purpose only and not a genuine Barber Colman product.

DC Variable Speed Drive Panel

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

RF Point Level Control with Sensor Monitor

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

5001TCP SPEED CONTROLLER

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Vibralert Mechanical Switch Model 5550

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

17429X.00 SERIES MODELS:

Fincor Series 2230 MKII/2240

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

R & D SPECIALTIES ROTROL I USER'S MANUAL

Electric Gage Shutdown Panels for DEUTZ 1011/2011, 912/913 and 914

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

EG1069X. Generator Electronic Governor Controller Operation Manual

Installation Instructions

Installation Instructions

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Motion sensors. Milltronics MFA 4p 6/17. Overview

Shock/Vibration Control Switches

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

Shock/Vibration Control Switches Installation Instructions Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 GENERAL INFORMATION LISTED*

CABINET REEL OPERATING INSTRUCTIONS

Process Protection Motion sensors

PRODUCT SERIES: DPG-2100

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

Application Engineering

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

SCR Power Controllers

5600 Series Power Operator Installation and Instruction Manual

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

Process Protection Motion sensors

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

POWERLINE 2000 Energy Management System TM

Adjustable Torque Controls

1.0 Features and Description

User Manual. 1. Introduction

Controlled Ferroresonant Ballast (CFB) Generation #3. Manual

MODEL 422 Submersible Pump Controller

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

MODEL SCA Installation and Operation Manual Important:

Barrel Size Metal Barrel Plastic Barrel. 5 Nm (3.7 ft-lb) 10 Nm (7.4 ft-lb) 15 Nm (11 ft-lb) 25 Nm (18 ft-lb) 90 Nm (66 ft-lb) 90 Nm (66 ft-lb)

********SERVICE MANUAL********* MODELS:

ITS-50R TRANSFER SWITCH OWNER S MANUAL

PROCAP Capacitance Level Sensors

Installation and Operating Manual

PITNEY BOWES FLEXIBLE INK JET TRANSPORT 36 FIT BASE: FIT-36. Parts Manual. (BOM: FIT36rev1.0) FIT-36parts_rev0 1

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

Process Protection Motion sensors

3.16. Inductive Proximity Sensors. Contents Description. E51 Limit Switch Style, Factory Sealed 6P+ Sensors

BAPI-Stat 3 Room Sensor

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

Ch 4 Motor Control Devices

8460SRC Replacement Chassis for Scully ST-6 and Biclops Monitors

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

Installation and Operations Manual

MAGNETIC MOTOR STARTERS

Transcription:

724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN DESCRIPTION The, Model 10-7100 is one in a series of critical speed switches that monitor speed and detect motion in all types of machinery and apparatus. The10-7100 monitors speed ranges of 60-800 RPMs. Models are available to meet any application requirement for underspeed, overspeed or zero speed detection. The utilizes a non-contacting proximity sensor that may be remotely located up to two miles from the control unit. Its rugged NEMA enclosure is well suited to meet the environmental challenges of any industry. Ideal for conveyors, crushers, fans, motors and other rotating apparatus. INSTALLATION CONTROLS AND INDICATORS DISCONNECT AC Power before proceeding with instructions. 1. Mount the control unit in a convenient location. 2. Make the following connections: A. Connect power cable to 120 VAC. B. Connect control cables to proper terminals in the motor control circuit. C. Connect EAGLE PROX SENSOR cable to the sensor connector on the control unit. 3. Install sensor at roller. See sensor installation sheet. SETUP AND TESTING Final calibration should be performed with the belt loaded and running at normal speed. 1. Turn SPEED ADJUST potentiometer (SPD1) CCW until it stops (approximately 7 o'clock). 2. Hold SW1 switch in SET* position to energize relay. 3. Turn SPEED ADJUST pot CW SLOWLY until CRITICAL SPEED LED stays on continuously. 4. Continue turning SPEED ADJUST pot CW until MARGIN LED begins to blink. ** 5. After RELAY LED is illuminated, return switch to RUN position. 6. There is a "safety delay" built into all EAGLE units. This delay leaves the control relay un-energized for 2.5 seconds after critical speed has been achieved to prevent false machinery actuation during maintenance or assembly. For the Eagle 3, channel 1 is adjustable from 0 10 seconds using TMR1. 7. Return switch to RUN position. 8. A momentary TEST* position is provided to simulate the loss of sensor signal which releases the control relay. * TEST position is up and SET position is down ** Using the above calibration, the control relay will drop out at a machinery slowdown of approximately 15%. For a 20% MARGIN, adjust the SPEED ADJUST control so that the MARGIN LED just comes on steady. For a 10% MARGIN, adjust the SPEED ADJUST control CCW so that the MARGIN LED has just gone out. SENSOR LEDs (CH1, CH2, CH3) CRITICAL LEDs MARGIN LEDs FIRST OUT LEDs RELAY LEDs (LED13, LED14, LED15) SPD1, SPD2, SPD3 Sensor LEDs blink when targets are seen by corresponding sensor Critical speed LEDs illuminate when target speed is => setpoint. These LEDs must be on continuously for control relay to energize Indicates percentage of slip (slow down) the channel is calibrated for (Off = 10%; Blinking = 15%; Solid = 20%) Indicates that the channel shut down due to speed going below set point. If the LED is off then something external caused the belt to shut off (OPTIMA mode ONLY) Illuminates when corresponding control relay is energized Speed adjust potentiometer for channels 1, 2 & 3 respectively TMR1 Channel 1 relay on-delay potentiometer Adjustable from 0 10 seconds (Eagle 3 only) Note Not all models will have the controls & indicators shown above

DIMENSIONS FIRST OUT OPERATION The EAGLE OPTIMA First Out capability enables the user to visually see (by an LED indicator) if the slip switch relay contacts were the first to open. Once the belt is running and the control relay in the OPTIMA unit has energized, the First-Out indication (if activated) will extinguish. If the belt begins to slip and the OPTIMA unit shuts the drive down, the First-Out LED will illuminate. This LED will stay lit until the belt is restarted and the control relay in the Optima has energized. If R1, R2, or R3 (See TYPICAL BELT STARTER) would open, this would shut the drive down and also the slip switch contacts would open. But, the First-Out LED would not be illuminated. This would allow the user to see that the slip switch relay contacts were not the first to open and cause the shutdown. DIP SWITCH SETTINGS Speed Setting SW1 SW2 SW3 60-800 RPM (default) OPEN OPEN 6-60 RPM (ALS6) * CLOSED OPEN 15-100 RPM (ALS15) * OPEN CLOSED 25-200 RPM (ALS25) * CLOSED CLOSED * Proximity Sensor Required for Proper Operation Reserved for future use Eagle/Optima Settings OPEN CLOSED SW4 Eagle Unit Optima Unit EAGLE/OPTIMA SETTINGS If switch 4 is open, then the unit is set to operate as a standard Eagle unit. The First Out LED will not operate in this mode. If switch 4 is closed, then the unit is set to operate as an Optima unit. In this mode the external control circuit should be wired through the set of contacts labelled First Out on the wiring chart. If the speed drops below the set point that was calibrated during setup, then the relay will turn off and the First Out LED will illuminate. If an external action caused the belt to shut down (i.e. pull cord, loose wire, external shutoff) then the First Out LED will be off when the relay opens. TERMINAL STRIP WIRING TER3 CHANNEL 1 CHANNEL 2 CHANNEL 3 1 N/C 7 Not Used 13 Not Used 2 C (FIRST OUT) 8 Not Used 14 Not Used 3 N/O (FIRST OUT) 9 Not Used 15 Not Used 4 N/O 10 Not Used 16 Not Used 5 C 11 Not Used 17 Not Used 6 N/C 12 Not Used 18 Not Used SPECIFICATIONS AC Input 120 VAC 15 W Fuse Protected 1 amp -40 o C - +60 o C (-40 o -+140 o F) Speed 60-800 RPM Relay Contacts DP/DT 8 amp @ 120 VAC First-Out AC Current 17mA 8 amps Safety Delay 2.5 Seconds Response Time 1 Second or Less Enclosure Hinged fiberglass with window / NEMA 4, IP66 REPLACEMENT AND OPTIONAL PARTS P.C. Board 10-7102 Proximity Sensor 10-7135 Relay 99-REL-0001 Strain Relief (Power Input) 99-CON-0011 Strain Relief (Control) 99-CON-0012 TER1 120VAC 1 120VAC Neutral 2 120VAC Hot

TYPICAL BELT STARTER MCCB OL M Motor 480 VAC 120 VAC 24 VDC + - Sequence R1 Pull Cord R2 Fire R3 Sensor Eagle Optima 1 Sensor 1 Ry 1 120 VAC Manual Automatic MCR BST R1 R2 R3 OL TDO INST MCR BST M

724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN PROX SENSOR Inductive Proximity Type MODELS 10-7135, 10-7136, 10-7139 DESCRIPTION The Eagle Proximity Sensor is designed to measure signals from any rotating apparatus and transmit this information by low-voltage 2- conductor twisted pair cable back to an Eagle control unit located up to 2 miles away. This sensor s inductive proximity technology is further enhanced with additional circuitry to reduce or eliminate the adverse effects of electrical noise. This sensor can easily be identified by its bright orange end-cap(s). 10-7135 10-7136 10-7139 FIGURE 1 COMPATIBILTY Eagle Proximity sensors are compatible with all Eagle Speed Switches and Dust Suppression Systems with the exception of the Eagle 2, Model 11-7000, which lacks our pulse conditioning circuitry. THEORY OF OPERATION The Eagle Proximity type sensor senses a target as it approaches the internal oscillator coil encapsulated in the sensor head. When the target approaches the front of the coil, this causes a decrease in the amplitude of the internal oscillator. This damping effect can be sensed at any RPM, thus the sensor can be used to sense speeds below 1 RPM and as high as several thousand RPM s. Because this type of sensor is not sensitive to the speed of the targets, the sensing distance remains approximately 1/8 at any speed. This eliminates missed targets as monitored speed changes. **NOTE - Shielded cable is recommended for all above ground applications. The shield of the cable should be attached to earth ground within 2 feet of the sensor head. In severe noise environments, grounding the shield at the control module also, will eliminate any E.M.I. interference. 10-7135 SPECIFICATIONS INSTALLATION 1. Select the roller or shaft to be monitored. If a roller is to be monitored, be sure it is always contacting the belt. 2. Affix a target on the roller or shaft. The target should be a piece of key-stock, 1/4-20 Hex Nut, etc. (Figure 1) NOTE: The use of a notch or a dent is not an acceptable target for the prox sensor. This sensor must see the presence of a target, not an absence of a target as there would be with a notch or dent. 3. Mount sensor firmly with hose clamps or U-bolts to prevent if from moving or working loose. Tape is NOT recommended as a fastener. 4. Before tightening, check that the target passes through the center area of the sensor face. This will produce the greatest sensitivity and sensing distance. With the roller or shaft spinning, move the sensor toward the target. The LED on the sensor should blink in direct proportion to the speed of the shaft or roller. Effective distance between the sensor and target is approximately 1/8 inch. Sensor Power Requirement 4.12 in. x 1.32 in. O.D. PVC / General Mount Control Unshielded** Twisted Pair 16/2-50 Ft. with Connector

PROX SENSOR Inductive Proximity Type MODELS 10-7135, 10-7136, 10-7139 10-7136 SPECIFICATIONS Sensor Power Requirement 4.91 x 1.30 in. O.D. PVC / Conduit Mount Control Unshielded ** Twisted Pair 16/2-3 Ft. Pigtail 10-7139 SPECIFICATIONS Power Requirement 4.12 in. x 1.32 in. O.D. Threaded PVC / Conduit or Bracket Mounting Control Unit Unshielded ** Twisted Pair 16/2-3 Ft. Pigtail (10-7139-50 has 50 pigtail) DOCUMENT DATE: 3/26/18 / PRODUCT REV. 0 (724) 283-4681 Fax (724) 283-5939