T5 Watt-Miser Linear Fluorescent lamps

Similar documents
Biax D and D/E. Compact Fluorescent Lamps Non-Integrated 10W, 13W, 18W and 26W. GE Lighting DATA SHEET. Product information.

Biax D and D/E. GE Lighting DATA SHEE T. Compact Fluorescent Lamps Non-Integrated 10W, 13W, 18W and 26W

2D Watt-Miser. GE Lighting DATA SHEET. Applications areas. Features. Lamp technology. Application areas

Spiral T2 10,000 & 8,000 hours

2D and 2D Watt-Miser. GE Lighting DATA SHEET. Compact Fluorescent Lamps Non-Integrated 16, 21, 28, 38W 2D Watt-Miser and 55W 2D. Product information

Lucalox XO High Pressure Sodium Lamps with improved reliability Lucalox TM XO Tubular Clear 50W, 70W, 100W, 150W, 250W, 400W & 600W

ConstantColor CMH Supermini

Edition Subject to change without notice. Errors and omissions excepted. Always make sure to use the most recent release.

Shatterfree fluorescent lighting

GE Lighting DATA SHEET. Product information. Features. Applications

ConstantColor CMH Supermini

GE ConstantColor CMH TM CMH SuperMini 20W & 35W

Efficient fluorescent lighting with improved color rendering

ConstantColor CMH MR16

Lucalox Standard Tubular Clear Product Code * * 11678* LU150/100/ HO/T/E40 LU150 /100/40

LUMILUX T5 HO XT LONG LIFE, REDUCED MAINTENANCE COSTS & SYSTEM GUARANTEE LUMILUX T5 HO XT & QUICKTRONIC. osram.com TECHNICAL INFORMATION 01

ConstantColor CMH Supermini Ultra

Arcstream Double Ended

QTi DALI/DIM / QTi GII / QTP5

ConstantColor CMH MR16 Ultra

Lucalox Standard. GE Lighting. Product information. Applications areas

HO 54 W/830. Product datasheet. LUMILUX T5 HO Tubular fluorescent lamps 16 mm, high output, with G5 base

L 58 W/840. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

L 58 W/840. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

ConstantColor CMH MR16

L 30 W/840. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

L 36 W/830. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

L 58 W/865. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

HO CONSTANT 39 W/840. Product datasheet. LUMILUX T5 HO CONSTANT Tubular fluorescent lamps 16 mm, high output, Constant

Product Description. MASTER TL5 High Efficiency. Benefits. Features. Application. Low-pressure mercury discharge lamps with a tubular 16 mm envelope

L 36 W/840 XT. Product datasheet. LUMILUX XT T8 Tubular fluorescent lamps 26 mm, with G13 bases, long life

HO 24 W/840. Product datasheet. LUMILUX T5 HO Tubular fluorescent lamps 16 mm, high output

L 36 W/827. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

HE 14 W/865. Product datasheet. LUMILUX T5 HE Tubular fluorescent lamps 16 mm, high efficiency, with G5 base

Product datasheet L 18 W/840 XXT

Multi-Vapor Metal Halide Lamps

MASTER TL-D 90 Graphica

PRODUCT DATASHEET L 18 W/827

HO 80 W/840. Product datasheet. LUMILUX T5 HO Tubular fluorescent lamps 16 mm, high output

L 36 W/840. Product datasheet. LUMILUX T8 Tubular fluorescent lamps 26 mm, with G13 bases

Product datasheet L 18 W/840

HE 14 W/827. Product datasheet. LUMILUX T5 HE Tubular fluorescent lamps 16 mm, high efficiency, with G5 base

Linear Fluorescent Lamps

GE ConstantColor CMH StreetWise

Commercial product name Power Factor Lamp power Voltage Warm Up Time to 60% Light

Product Description. MASTER PL-S 2 Pin

Product Description. MASTER HPI-T Plus. Quartz metal halide lamps with clear outer bulb

HaloGLS, HaloCandle and HaloSpherical lamps

LUMILUX T5 HE. Product datasheet 14 W/840. Product benefits. Product features

Retrofit without Compromise

LUMILUX T8. Product datasheet 18 W/835. Product benefits. Product features

HCI-TT 250 W/830 SUPER 4Y

Fluorescent SPECTRUM

HCI-TT 250 W/830 SUPER 4Y

Compact Fluorescent Lamps Non-Integrated

Product Description. MASTER HPI Plus. Benefits. Features. Application. Quartz metal halide lamps with opalized outer bulb

Simply irresistable. Superior light quality from start to finish

Energy efficient low voltage dichroic mirror halogen reflector lamps

Lucalox PSL. GE Lighting DATASHEET. Lucalox PSL Tubular Clear 230V 250W, 400W, 600W and 750W Lucalox PSL Tubular Clear 400V 600W and 750W

The world's brightest fluorescent lighting

OSRAM DULUX L LUMILUX

LUMILUX XXT T8 Tubular fluorescent lamps 26 mm, with G13 bases

HCI-T 35 W/830 WDL PB

LED T8 BP. GE Lighting. Tubular lamps DATA SHEET. Specification Features. Product information. Applications. IEC standards

Basic fluorescent lighting

HCI-TS 150 W/830 WDL PB

LUMILUX SPLIT control T8 Tubular fluorescent lamps 26 mm, with G13 bases

Product Description. MASTER TL-D Super 80. Low-pressure mercury discharge lamps with a tubular 26 mm envelope

Basic fluorescent lighting

E-CORE LED TUBE GX16T-5 DATA SHEET 1 /5

HCI-T 150 W/830 WDL PB

Product Description HPL-N. Benefits. Features. Application. Versions. Standard High Pressure Mercury lamp. Good budget alternative

HSI-HX / HSI-THX SA HSI-THX 400W 4K E40 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

Commercial product name Lamp Current Power Factor Lamp power Voltage Warm Up Time to 60% Light

FLUORESCENT INDUCTION

Product Description. MASTER TL-D 90 De Luxe. Benefits. Features. Application. Low-pressure mercury discharge lamps with a tubular 26 mm envelope

Beautiful sparkle, reliable life

ConstantColor CMH PAR 20 & PAR 30 Ceramic Metal Halide Lamps 20W, 35W and 70W

Infusion Module NPM Series

SHP-S/SHP-TS Super SA SHP-TS 70W/CL E27 SLV PRODUCT OVERVIEW DATA TABLE. Optical data

A new age in outdoor city lighting

Replacement Lamps. Mercury Vapor Standard. Benefits. Features. Application

Powerful, ultra-slim lamps

GE Lighting. Biax TM. Plug-in Compact Fluorescent Lamps ENERGY SAVING LIGHTING

Infusion Module NPM Series

FC 22 W/840 2GX13. Product datasheet. LUMILUX T5 FC Circular fluorescent lamps 16 mm. Product benefits. Product features

Direct retrofit with immediate energy savings for quartz metal halide

Product Description SON-T. Benefits. Features. Application. High Pressure Sodium lamp with clear tubular outer bulb

Replacement Lamps. Mercury Vapor Standard. Benefits. Features. Application

Infusion Module Gen2 M1000, M1500, M2000 and M3000 Series

DULUX D/E 18 W/840. Product datasheet. OSRAM DULUX D/E CFLni, 2 tubes, with 4-pin base for ECG operation

LUMILUX T5 HE. Product family datasheet. Tubular fluorescent lamps 16 mm, high efficiency, with G5 base

Shatterfree fluorescent lighting

POWERBALL HCI-TT. Product datasheet 70 W/830 WDL E27. Product benefits. Benefits of POWERBALL technology

Product Description HPL-N. Benefits. Features. Application. Versions. Standard High Pressure Mercury lamp. Good budget alternative

DULUX D/E 26 W/840. Product datasheet. OSRAM DULUX D/E CFLni, 2 tubes, with 4-pin base for ECG operation

GE Lighting. Single Ended G8.5 Ceramic Metal Halide Lamps Product Information for Original Equipment Manufacturers

DULUX T/E PLUS 42 W/840

DULUX D/E 18 W/840. Product datasheet. OSRAM DULUX D/E CFLni, 2 tubes, with 4-pin base for ECG operation

Transcription:

GE Lighting T5 Watt-Miser Linear Fluorescent lamps DATA SHEET T5 Watt-Miser High Efficiency 14W, 21W, 28W, 35W T5 Watt-Miser High Output 24W, 39W, 49W, 54W, 80W Product information T5 Watt-Miser lamps are energy saving triphosphor fluorescent lamps with 16mm outer diameter for general T5 lighting applications. Features T5 Watt-Miser lamps with a long life of 25,000 hours consume 5% less energy compared with today s standardwattage T5 lamps on the market, without compromising lumen output as verified also by independent test-house. 5% energy saving is achieved based on test procedures using current controlled ballasts. When power controlled ballasts are used, these lamps will run at ballast rated wattage and lamps will give additional light no adverse effect would be experienced on lamp life. Full energy saving will be reached after lamps have been seasoned for 100 hours. Similarly to all other T5 lamps performance of the T5 Watt-Miser lamps are optimised for 35 C ambient temperature, offering up to 111 lm/w luminous efficacy. The elevated optimum temperature results in additional energy saving versus T8 lamps in typical indoor lighting applications. Standard T5 lamps can easily be replaced with the new T5 Watt-Miser lamps in the existing lighting applications, since new electronic control gears are not required. These new lamps from GE enable even less than 6 months payback time! GE is committed to fight against climate change. The T5 Watt-Miser lamps will contribute to the global effort to reduce CO 2 emission. One lamp can save 1.2-6.9kg carbon dioxide per year depending on the type. So in addition to the lower energy bill, millions of tons of CO 2 could potentially be saved with this new lamp technology in Europe. Application areas T5 Watt-Miser lamps are recommended for general T5 lighting applications, such as: Retail Offices Schools Commercial Industrial Product range T5 Watt-Miser lamps are available in 9 wattages; offering an energy saving version for all T5 lamps. For easy identification, the stamping colour is green, and the new product descriptions refer to the existing standard nominal wattages. E.g. a luminaire having the already known F14W LongLast T5 lamps inside, can be relamped with the new F14 Watt-Miser. The entire range consists of the following models: 2-ft F14, F24 3-ft F21, F39 4-ft F28, F54 5-ft F35, F49, F80 Available colour temperature: 3000K warm white 4000K cool white Compliance The T5 Watt-Miser linear fluorescent lamps comply with IEC/EN 60061 and IEC/EN 61195.

Basic data T5 Watt-Miser High Efficiency Lamp Type 14W 21W 28W 35W General Nominal Wattage [W] 14 21 28 35 Cap G5 G5 G5 G5 Operation high frequency high frequency high frequency high frequency Cathode preheated preheated preheated preheated Design Temperature [ C] 35 35 35 35 Recommended Burning Position horizontal horizontal horizontal horizontal Energy Efficiency Class A A A A Average Mercury Content [mg] 2.5 2.5 2.5 2.5 Ordering Information (30-way sleeve pack) 830 CCT 3000K Warm White 79418 - - 79417 840 CCT 4000K Cool White 61080 61079 61078 61077 Electrical and Photometric Characteristics at 25 C Rated Wattage [W] 13.3 19.6 26.5 33.7 Rated Lamp Voltage [V] 82 120 158 195 Rated Lamp Current [A] 0.165 0.165 0.170 0.175 Operating Frequency [Hz] > 20 > 20 > 20 > 20 Rated Luminous Flux [lm] 1230 1910 2640 3320 Nominal Luminous Flux [lm] 1230 1910 2640 3320 Rated Efficacy [lm/w] 92 97 100 99 Colour Rendering Index [Ra] 85 85 85 85 UV PET [h] >100 >100 >100 >100 Electrical and Photometric Characteristics at 35 C Rated Wattage [W] 13.0 19.7 26.4 33.0 Rated Lamp Voltage [V] 78 117 159 199 Rated Lamp Current [A] 0.170 0.170 0.170 0.170 Rated Luminous Flux [lm] 1350 2100 2900 3650 Nominal Luminous Flux [lm] 1350 2100 2900 3650 Rated Efficacy [lm/w] 104 107 110 111 Lifetime Performance Rated Median Life Preheat, 3 Hours Cycle [h] 25,000 25,000 25,000 25,000 Median Life Preheat, 12 Hours Cycle [h] 30,000 30,000 30,000 30,000 Operating Mode for LSF and LLMF Data Lamp Survival Factor LSF 2,000 Hours 99% 99% 99% 99% LSF 4,000 Hours 99% 99% 99% 99% LSF 6,000 Hours 99% 99% 99% 99% LSF 8,000 Hours 99% 99% 99% 99% LSF 12,000 Hours 97% 97% 97% 97% LSF 16,000 Hours 92% 92% 92% 92% LSF 20,000 Hours 79% 79% 79% 79% Lamp Lumen Maintenance LLMF 2,000 Hours 97% 97% 97% 97% LLMF 4,000 Hours 95% 95% 95% 95% LLMF 6,000 Hours 94% 94% 94% 94% LLMF 8,000 Hours 93% 93% 93% 93% LLMF 12,000 Hours 91% 91% 91% 91% LLMF 16,000 Hours 90% 90% 90% 90% LLMF 20,000 Hours 89% 89% 89% 89% Service Life Preheat, 3 Hours Cycle [h] 17,000 17,000 17,000 17,000 Service Life Preheat, 12 Hours Cycle [h] 20,000 20,000 20,000 20,000 Measuring conditions Frequency [Hz] 20-26 20-26 20-26 20-26 Calibration current [A] 0.170 0.170 0.170 0.170 Voltage of HF generator [V] 163 240 321 403 Reference resistor [ohms] 500 725 950 1200 2

Basic data T5 Watt-Miser High Output Lamp type 24W 39W 49W 54W 80W General Nominal wattage [W] 24 39 49 54 80 Cap G5 G5 G5 G5 G5 Operation high frequency high frequency high frequency high frequency high frequency Cathode preheated preheated preheated preheated preheated Design Temperature [ C] 35 35 35 35 35 Recommended Burning Position horizontal horizontal horizontal horizontal horizontal Energy Efficiency Class A A A A A Average Mercury Content [mg] 2.5 2.5 2.5 2.5 2.5 Ordering Information (30-way sleeve pack) 840 CCT 4000K Cool White 61076 61075 61073 61074 61072 Electrical and Photometric Characteristics at 25 C Rated Wattage [W] 21.4 36.1 46.7 51.4 75.8 Rated Lamp Voltage [V] 73 112 185 114 144 Rated Lamp Current [A] 0.295 0.325 0.255 0.455 0.53 Operating Frequency [Hz] > 20 > 20 > 20 > 20 > 20 Rated Luminous Flux [lm] 1750 3200 4450 4460 6150 Nominal Luminous Flux [lm] 1750 3200 4450 4460 6150 Rated Efficacy [lm/w] 82 89 95 87 81 Colour Rendering Index [Ra] 85 85 85 85 85 UV PET [h] >100 >100 >100 >100 >100 Electrical and Photometric Characteristics at 35 C Rated Wattage [W] 21.4 36.1 46.8 51.1 76.0 Rated Lamp Voltage [V] 71 106 181 112 138 Rated Lamp Current [A] 0.300 0.340 0.260 0.460 0.555 Rated Luminous Flux [lm] 2000 3500 4900 5000 7000 Nominal Luminous Flux [lm] 2000 3500 4900 5000 7000 Rated Efficacy [lm/w] 93 97 105 98 92 Lifetime performance Rated median life - preheat, [h] 25,000 25,000 25,000 25,000 25,000 Median life - preheat, 12h cycle [h] 30,000 30,000 30,000 30,000 30,000 Operating mode for LSF and LLMF data Lamp survival factor LSF 2,000 Hours 99% 99% 99% 99% 99% LSF 4,000 Hours 99% 99% 99% 99% 99% LSF 6,000 Hours 99% 99% 99% 99% 99% LSF 8,000 Hours 99% 99% 99% 99% 99% LSF 12,000 Hours 97% 97% 97% 97% 97% LSF 16,000 Hours 92% 92% 92% 92% 92% LSF 20,000 Hours 79% 79% 79% 79% 79% Lamp lumen maintenance LLMF 2,000 Hours 97% 97% 97% 97% 97% LLMF 4,000 Hours 95% 95% 95% 95% 95% LLMF 6,000 Hours 94% 94% 94% 94% 94% LLMF 8,000 Hours 93% 93% 93% 93% 93% LLMF 12,000 Hours 91% 91% 91% 91% 91% LLMF 16,000 Hours 90% 90% 90% 90% 90% LLMF 20,000 Hours 89% 89% 89% 89% 89% Service life - preheat, [h] 17,000 17,000 17,000 17,000 17,000 Service life - preheat, 12h cycle [h] 20,000 20,000 20,000 20,000 20,000 Measuring conditions Frequency [Hz] 20-26 20-26 20-26 20-26 20-26 Calibration current [A] 0.300 0.340 0.255 0.460 0.550 Voltage of HF generator [V] 146 218 380 229 282 Reference resistor [ohms] 250 330 765 255 260 3

Dimensions Cap-G5 IEC 60061 Data sheets 7004-52-5 C B A D 4.75 Max. Ø 15.75 11.5 Max7.62 Max. Ø 2.67 Dimensions measured on finished lamps F14, F24 F21, F39 F28, F54 F35, F49, F80 A Max Base to Base [mm] 549 849 1149 1449 B Min Pin to Base [mm] 553,7 853,7 1153,7 1453,7 B Max Pin to Base [mm] 556,1 856,1 1156,1 1456,1 C Max Pin to pin [mm] 563,2 863,2 1163,2 1463,2 D Max Outer Diameter [mm] 17 17 17 17 Influence of ambient air temperature on light output T5 Watt-Miser lamps are designed to reach their maximum luminous flux at an ambient air temperature of 35 C under reference conditions. The light output and the electrical characteristics of a low-pressure mercury vapour lamp are determined by the saturated mercury vapour pressure inside the tube. As the cold spot is near the metal cap, the cap temperature is a good indication how close the Hg vapour pressure is to the optimum. A cap temperature of approximately 43-45 C corresponds to conditions resulting in maximum light output in a stabilized T5 lamp. The mercury vapour pressure is related to the temperature of the so called cold spot, the coldest part of the lamp where the excess liquid mercury is deposited. The cold spot is behind the electrode on the monogrammed side in a T5 lamp. The diagram below shows the typical relative luminous output of a long T5 lamp as function of ambient air temperature in horizontal burning position under reference conditions. Please note, burning position, air flow, radiating heat sources, characteristics of the control gear, etc also affect the thermal conditions. Test conditions: thermal chamber with ± 2 C accuracy draught-free air constant lamp current horizontal burning position Ambient Air Temperature [ C] Relative Luminous Flux [%] -10 9-5 14 0 22 5 32 10 45 15 60 20 76 25 91 30 98 35 100 40 97 45 92 50 86 55 81 60 76 Relative luminous flux [%] 100 80 60 40 20 0-10 0 10 20 30 40 50 60 Ambient air temperature [ C] 4

Lamp life and lumen maintenance Cathodes of a fluorescent lamp lose their electron-emissivity during life due to various degradation processes like evaporation and sputtering. When the deterioration reaches a certain level, the cathode fails. Typical lifetime characteristics given below are based on GE Lighting s data. The declared lamp life is the median life defined by the time when 50% of the lamps from a large sample batch would have failed. Real lifetime figures may depend on the actual application. For instance improper cathode preheat, too high operating current, or too low operating current without additional cathode heating might reduce the expected life. The lumen maintenance graph below shows the luminous output throughout life. The main causes of the light depreciation are deterioration of phosphor coating and lamp blackening due to the deposition of evaporated emission mixture on the glass tube. These effects are unavoidable. Service life is reached when the light level in an installation drops down to 80% of the initial value. The service life curve is drawn as the product of the survival and the lumen maintenance curves. 110% Life expectancy and lumen maintenance T5 Watt-Miser 3 hours cycles 110% Life expectancy and lumen maintenance T5 Watt-Miser 12 hours cycles 100% 100% 90% 90% 80% 80% 70% 60% Survival rate Lumen maintenance Service life 70% 60% Survival rate Lumen maintenance Service life 50% 0 5,000 10,000 15,000 20,000 25,000 30,000 Operating hours 50% 0 5,000 10,000 15,000 20,000 25,000 30,000 Operating hours Recommendations for measuring T5 Watt-Miser lamps For initial readings, the lamps shall be aged for 100 hours. Before measurement, conditioning is also required. Conditioning is completed when the excess mercury has been collected at the cold spot. Such conditioning may take up to 20 hours which can be part of the 100 hour aging. Avoid touching the hot glass surface, rotating or shaking the lamp. During handling and transportation keep the cold chamber (monogrammed side) at the lowest point. If the lamps are switched off for more than 12 hours, they shall be burnt for at least 4 additional hours with cold chamber down. Place the lamp into the test system in horizontal position. Before measuring the luminous flux, the lamp shall be continuously burnt for one hour. Stability shall be checked by monitoring the luminous flux. The measured luminous flux can be considered stable if the relative change is less than 0.5% over a 5 minute period. Dimming Dimming is done by the control of the discharge current. In dimming mode, the optimum cathode temperature shall be maintained by additional cathode heating current. All GE T5 lamps are given a seasoning burn-in at the end of the assembly line. This is sufficient cathode preparation for dimming, no additional burn-in at full power is required before using the lamp for the first time. Please note that after transportation and installation, the mercury is scattered in the tube. For stabilized operation, the excess mercury should be migrated to the cold spot. This may take up to 20 hours of full-power operation. The stabilization time becomes even longer if the lamps are dimmed. Emergency operation In emergency operation, lamps are typically underdriven running at low power. To save battery life, emergency inverters may not apply additional cathode heating which would be necessary to maintain the proper cathode temperature. Such unfavourable conditions result in accelerated blackening and shorter life over a longer period in emergency mode. In a typical application, the emergency lighting system is tested for a short period on a regular basis. The cummulative impact on lamp life can generally be considered low. Ballast compatibility Ballasts produced by reputable control gear manufacturers meeting the relevant IEC standards would be considered as suitable. List of recommended ballasts available on request. 5

Spectral power distribution Spectral power distribution 3000K Spectral power distribution 4000K 250 250 200 200 µw/nm/1lm 150 100 µw/nm/1lm 150 100 50 50 0 380 0 430 480 530 580 630 680 730 380 Wavelength [nm] 430 480 530 580 630 680 730 Wavelength [nm] Colour specification according to CIE 1931 Nominal CCT [K] Rated X Y CRI [Ra] 3000 2940 0.440 0.403 85 4000 4040 0.380 0.380 85 www.gelighting.com/eu and General Electric are both registered trademarks of the General Electric Company GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specifications from time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted. T5 Watt-Miser Data Sheet March 2011