Power+ CLASSIC. 20/30 kva, 3x208 Vac

Similar documents
POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

TECHNICAL DATA SHEET KVA UPS Systemss

EFFEKTA Power Supplies

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical Data Sheets

Technical Data Sheets

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Technical data sheets

Technical Data Sheets

Technical Data Sheets

D Series: UPS UPTO - 300KVA - Three / Three Phase

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical Data Sheets

POWER kva

POWER kva

Technical Data Sheets

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

Est FlexiPower Mini UPS FPX Mini kVA

MKN-DSP SERIES - THREE PHASE

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

PowerWave 33 Efficient power protection for today s IT and process-related work environments

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical data sheets

Liebert. FP 50Z kva

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Aurora Single Phase Emergency Lighting Inverters

Technical Data Sheets

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PowerValue 11/31 T kva

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

ConceptpowerTM Modular kVA

TRIMOD HE UPS. MODULAR THREE-PHASE UPS from 10 to 80 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

UPS5000-E (25-75 kva) Series

Illuminator Series CR NEMA 3R

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Onfiniti. 1 Phase UPS

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

TECHNICAL SPECIFICATIONS

Three Phase UPS Systems Range: 10 to 500kVA

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor MOD THREE-PHASE MODULAR UPS. up to 250 kw THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL INFRASTRUCTURES

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Phase Modular Finally the benefits of Modular ups are for all

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

G9000 UNINTERRUPTIBLE POWER SYSTEMS

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TLE Series UPS 400/500 kw With eboost Technology

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

EATON 9315 UPS 200 TO 300 KVA Specifications

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

1.1 GENERAL CHARACTERISTICS

TLE Series UPS 160/200/225/250 kw with eboost Technology

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

G9000 UNINTERRUPTIBLE POWER SYSTEMS

YOUR POWER IN SAFE HANDS. E Series UPS

TLE Series UPS 750/1000 kw With eboost Technology

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

PowerWAVE EL. (Single-phase 500 VA 30 kva. Three-phase kva)

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Technical Specification SENTINEL PRO

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

POWERTRONIX QUASAR 5-40 KVA

UPS. MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Uninterruptible Power Supplies

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Master Plus kva

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Distinctive Features: Bidirectional solar PCU Hybrid inverter (Solar/ Grid/BATT) Vector Modulated Inverter Control Multiple DSP control operation

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Transcription:

Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries

Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies in the field of power electronics and UPS technology worldwide. The Power+ CLASSIC is an electrically and mechanically modular UPS system, uniquely designed to scale up as power requirements grow. Easily upgradable on-site through addition of plug-and-play 10KVA modules, the Power+ CLASSIC offers an optimal combination of efficiency, economy, and usability and boasts the industry s lowest TCO (Total Cost of Ownership) and fastest ROI (Return on Investment). A Power+ UPS provides: Uninterruptible power for critical loads during failure of AC mains Protection of load against variation in mains power voltage and frequency Elimination of power line noise and voltage transients High power density with a space saving footprint User-friendly controller with easily accessible communication and control options Intelligent battery handling that helps prolong battery life Simple maintenance procedures Significant energy savings and lower cooling costs

Designed from the ground up with cost reduction in mind, the Power+ CLASSIC line of UPSs are completely modular, and can be custom built to meet specific needs. Each module is entirely self-contained and ready for hot-swapping without the need for storage of spare components, subsystems, or parts. The Power+ CLASSIC is comprised of 10KVA building modules. Built to grow as business expands, this modular UPS enables purchasing for the capacity of today, with the ability to expand for tomorrow. The UPS module is the core of the Power+ CLASSIC. The model featured here can be built to include either two or three identical UPS modules in parallel, depending on capacity requirements. Each UPS module includes a 3-phase charger with PFC (Power Factor Correction) and a 3-phase PWM (Pulse Width Modulation) inverter connected to batteries by a classic DC link. Each module is plug-in and weighs a mere 22 lbs. (10 kg). The Power+ CLASSIC can be configured with either two or three internal battery boxes, depending on the number of power modules. Each internal battery box holds 32 x 12 V batteries. The batteries are available in capacities of either 7 Ah or 9 Ah. Each internal battery cabinet provides sufficient backup power for one 10 kva / 8 kw module. The Power+ CLASSIC 20 kva and 30 kva models with internal batteries have a footprint of less than 4.6 sq. ft. (0.42 m2). The internal DC batteries add a clear space-saving advantage. A Power+ CLASSIC system with three 10 kva power modules and three sets of internal batteries.

Figure 1: Internal battery box Key to Figure item description 1 Internal battery box. Houses 4 drawers. Each drawer holds eight batteries. 2 Removable front panel of the battery box. 3 One of four battery drawers 4 Top cover (lid) of a battery drawer 5 Drawer with 8 batteries. Available in capacity of 7 Ah or 9 Ah. All of the batteries in a battery box must have the same Ah rating.

Power+ CLASSIC UPS system, 3x208 V, 20/30 kva, with internal batteries Power + TECHNICAL DATA Topology Construction Operation Input Voltage (Vac) True on-line battery, double-conversion, VFI Modular, parallel hot-plugged modules Continuous Voltage range (%) +15 and 25 Current (A) Frequency (Hz) 47 ~ 63 Power walk-in (sec) Power factor 0.99 3 208 + N (4 wires + Ground) 28 per module no inrush current at startup 1 to 60 in 1 sec increments THDI (%) 5 Output Rated power (kva / kw) 20 / 16 or 30 / 24 Frequency tracking range (Hz) Slew rate (Hz/sec) 1 Voltage (V) Static regulation (%) ±1 Regulation for unbalanced load (%) Dynamic response to 100% load step (%) ±2 Overload Waveform THD (%) Inverter mode Bypass mode Load CF 4:1 Ac-ac efficiency, nominal (%) ±0.5, ±1, ±2, ±3, ±4 (selectable) 3 208 + N (4 wires + Ground) ±1 for 100 % unbalanced load 110 % for 10 minutes, 125 % for 60 sec 1000% for 1 cycle Sinusoidal Less than 2 for linear load Up to 94 at full load Dc-ac efficiency, nominal (%) Up to 97 at full load Batteries Dc-link voltage (Vdc) +/ 160 to +/ 216 Quantity and type 32 12 Vdc, 7 Ah or 9 Ah Type Sealed, lead acid, rechargeable General Maximum power dissipation (Po=8 kw) N*510 W (N*998 BTU), N = # power modules (2 or 3) Ambient temperature operation: storage: Relative humidity (%) Altitude (m) Enclosure Cooling system +14 to +104 F (-10 to +40 C) -4 to +140 F (-20 to +60 C) 95 max., non-condensing 1500 without derating IP20 Multi-fan with speed control (forced) Standards EMC emissions IEC 62040-2; FCC part 15/B Safety UL 1778 (2 nd Ed.); IEC 62040-1 Design IEC 62040-3 Low magnetic field radiation EMF as per ICNIRP Dimensions (U.S. measurements) UPS type 20 kva 30 kva Size (in) and weight (lbs) 52.2 (H) x 23.6 (W) x 27.2 (D); 258 66.1 (H) x 23.6 (W) x 27.9 (D); 291 Dimensions (metric measurements) Size (mm) and weight (kg) 1325 (H) x 60 (W) x 69 (D); 117 1678 (H) x 591 (W) x 707 (D); 132 Acoustic Noise Noise (dba)with half load 52 53 Noise (dba) with full load 54 55 All specifications are subject to change without advance notice.

PowerPlus CLASSIC, 3x208 V, 20/30 kva: controller specifications System Controller TECHNICAL DATA Microcontroller core Display 16 bit 4 40 characters LCD with backlight Other indicators Analog input channels Voltage-free user input channels (dry contacts) 8 8 LEDs, buzzer 3 for battery current measurement 1 for temperature measurement Real Time Clock (RTC) Power meter Voltage-free outputs (dry contacts) RS232 user port Optional communication Communications with system modules Events log System operation without controller On-screen parameters Alarms (floating output relay contacts, each rated for max. 48 Vdc 1 A) Power requirements Yes (operates for 2 weeks without power) kva, kw, PF 6 outputs, rated 50V/1A Yes, isolated TCP/IP, GPRS/SMS wireless communications (optional) Serial, isolated 255 events Unchanged Load-level bar-graph, 3-phase voltages, 3-phase currents, battery voltage, status of each UPS module, static-switch parameters and status, battery temperature sensor AC failure, DC failure, UPS module(s) failure, load on bypass, battery test failure, over/under temperature, overload 3 208 Vac / ±216 Vdc 15 W

We are available worldwide, with direct representation in the UK, China, South Africa, Brazil, India and partners throughout the world. Choose - our power, your confidence GAMATRONIC ELECTRONIC INDUSTRIES LTD. Headquarters and Factory 17 Hartom St. POB 45029, Jerusalem 9777517, Israel Tel: +972-2-5888222 Fax: +972-2-5828875 info@gamatronic.co.il www.gamatronic.com March 2016