LaneLED INOX42. Installation instructions. LaneLED INOX42. VERSION MODIFICATIONS 1.0 First edition 1.1 Supplement in chapter 5.1. Created.

Similar documents
LaneLED INOX42 Handrail Lighting System

Operating instructions

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

YOUR WISH IS OUR COMMAND. Junction boxes. Catalogue-Junction boxes

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

LaneLED INOX48 Handrail Lighting System

3-5 Hours Professional installation recommended

2-3 Hours Professional installation recommended

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

Installation Instructions

2-3 Hours Professional installation recommended

LaneLED GFK Handrail Lighting System

YOUR WISH IS OUR COMMAND. AlphaLUXX Floodlight. Product information

2-3 Hours Professional installation recommended

Custom Dynamics Spyder Stingerz Installation Instructions

Aopec Dual Battery Kit Fitting Instructions

3-5 Hours Professional installation recommended

ACROBAT SWING STAND MODEL

Cable reels 02/2008. Power - wherever you need it. power. wherever. you need it. Custom made solutions

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

3M Cold Shrink QT-III Silicone Rubber Termination

I N S T A L L A T I O N G U I D E. Chevrolet Silverado / GMC Sierra - Ext Cab * A (Diesel Only)

channel damage the internal components and the weight may break the internal wiring or flexible strip.

Safety Sentry Electronic Breakaway Switch

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1).

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

User manual for. Exalto windshield wiper Type 223 BD 12/24 Volt

Assembly Instructions

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

Contents. Preparing the motor Winding the rotating secondary Winding the primary... 8

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Installation Manual Lock-Switch KIA Sorento V3 Installation Manual Lock-Switch V3 for KIA Sorento (02-06) and KIA Sorento (07-09)

ACROBAT SWING STAND MODEL

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

ET-PWR-END-KIT Installation Instructions (part #JSR00)

Product Information Overspeed governor GB 260

Solar Trike w i t h A C C U b a t t e r y d r i v e a n d LED lighting

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

3-5 Hours Professional installation recommended

DC Master 24/ A

= Experienced

Fitting Instructions

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

TECH TIPS. Ford LRG423. Service Call: Unit will not stay running on gas from Platform Controls but runs fine on propane.

3-Phase, Dual-Input, 12.5kW Power Supply System USER GUIDE

INSTALLATION INSTRUCTIONS: Viewline 52 mm

PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS: Viewline 52 mm

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

Amphenol. eries SJT. Series SJT. VG 96912, Series 1 PAN JN 1003

Ram 1500 Crew Cab A Ram 2500/3500 Crew Cab A

400 Watt WIND TURBINE

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Lightning Ball Tools Required: ø 2 ø 3,5 ø 4 Pencil. Drill. Ruler. Fretsaw. Handsaw with Metal Saw Blade. Hot Glue Gun.

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

INSTALLATION INSTRUCTIONS

w w w. h d o n l i n e s h o p. d e ROAD TECH QUEST GLOBAL POSITIONING SYSTEM (GPS) MOUNTING KIT GENERAL INSTALLATION -J03554 REV.

KWIKEE DOOR SWITCH STEP ACTIVATION INSTALLATION GUIDE ( )

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Doodad Tape Light & Halcyon Controller Single Colour Installation Instructions


SERVICE INSTRUCTIONS

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

Repair Instructions for Cogard 3000 Collector

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

MODEL ELC-12/60-D BATTERY CHARGER

I N S T A L L A T I O N G U I D E

CERTAIN TRANSIT VEHICLES EQUIPPED WITH A TRAILER MODULE TRAILER MODULE FUSE AND FOOTWELL DRAINAGE HOLE

240V UPS Typical Installation Guide

MULTI-P URPOSE S HELTER

April 11, 2013 Revision 0. Buffer Pass Unit - J1 Service Manual

ALWAYS follow all Webasto installation and repair instructions and observe all warnings.

INSTRUCTION MANUAL SINKER. By HAY

3-5 Hours Professional installation recommended

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM. Parts List and Installation Instructions CAUTION

3-5 Hours Professional installation recommended

Swiveling gripper finger GFS 16-40

NOTES: 1489 N THESTA FRESNO, CA PHONE (559) FAX (559)

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

Installation Manual. Spring Cable Reel (SCR) C BEF E-RLS-S. MAL b-EN translated document Page 1 of 17

Chapter 2. Battery Charger and Base Assembly

WEDICO. `çãéäéíé=háí= q~åâ=péãájqê~áäéêi=çî~ä= Art.-No. 67 polished. Measurements Length 745 mm Width 160 mm Height 250 mm Weight 3.

YOUR WISHES ARE OUR BENCHMARK. Transformers. Catalogue

STAND MODEL FOR MACH M2

Tip: and Orient Express LED Light Upgrade Date: Correction

Assembly instructions VOSS quick connect system 246 NX

FOSC-100 B/H FOSC-100 B2/H

I n s t a l l a t i o n I n s t r u c t i o n s

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

The pneumatic applicator complies with the following safety guidelines: CE

P Original Series Cargo Van Lift Mounting Instructions Fullsize Ford Van present. Preparing the Gate

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

COLD WEATHER START KIT Ceiling Mount 8000

Transcription:

Installation instructions VERSION MODIFICATIONS 1.0 First edition 1.1 Supplement in chapter 5.1 Page 1 / 22

Table of contents 1 General information... 3 1.1 Marking concept for hazards and hints... 3 1.2 Responsibilities of the operator... 3 2 Introduction... 4 2.1 Installation conditions LaneLED... 4 3 Required tools... 5 3.1 Consumables... 7 4 Montage... 8 4.1 In general... 8 4.2 Mounting... 8 5 Installation of LaneLED light bars... 9 5.1 Mounting the adapter to the LED carrier profile... 9 5.2 Fitting the system cable... 9 5.3 Supply line connection... 9 5.4 Assembly of LED light bar: variant 1... 11 5.4.1 Current collector connection... 11 5.4.2 LED light bar connection... 12 5.5 Assembly of LED light bar: variant 2... 12 5.5.1 Current collector connection... 12 5.5.2 LED light bar connection... 12 5.6 Diffusor mounting... 14 6 Detailed installation information... 15 6.1 Press current collector onto the system cable with special crimping pliers... 15 6.2 Finishing the system cable ends... 16 6.3 Connecting/repairing the system cable... 18 6.4 Isolation of system cables... 21 7 Service... 22 7.1 Service addresses... 22 7.2 Imprint... 22 Page 2 / 22

1 General information 1.1 Marking concept for hazards and hints Hazard Hazardous situation which will cause serious injury or even death if it is not prevented. Caution Hazardous situation which could cause slight to moderate injury if it is not prevented. Hint Indicates information which does not concern personal injury, e.g. hints in respect of material damage. Protective measures Increase safety by applying a protective measure. 1.2 Responsibilities of the operator Make sure that this document is always kept in a safe place in a legible form together with the product. Read these instructions carefully before first start-up of the product. This product has been developed and produced exclusively for the use indicated in these documents. Every other use, which is not mentioned explicitly, could affect the intactness of the product and/or could constitute a source of danger. The manufacturer rejects any liability for damage which has been caused by incorrect or non-intended use of the product. In countries, which do not belong to the European Community, the national legal reference regulations as well as the standards and regulations applicable in these countries have to be observed for warranty of a corresponding safety level. The installation has to be carried out according to the applicable regulations. The manufacturer assumes no liability for inexpert execution of installation as well as deformations which may occur during operation. The electric power supply has to be switched off before executing any action on the installation. Exclusively original parts of the manufacturer shall be used for maintenance. Maintenance work may be carried out by qualified staff only. All procedures which are not explicitly mentioned by the manufacturer in the instructions are not permitted. The packing material must not be stored within the reach of children as it could be a potential source of danger. Page 3 / 22

2 Introduction To ensure proper installation, the following steps and notes must be complied with under all circumstances. Only this way can it be ensured that the product will work to complete satisfaction. Hazard Read all instructions before starting installation. Our sales department will be happy to answer any questions you may have. 2.1 Installation conditions LaneLED To comply with the necessary operating voltage, the number of connected LaneLED light bars must be adjusted to the line length. The maximum line length for the number of LaneLED light bars required must be calculated for the specific installation. LaneLED light bars must be calculated specifically for the plant. Installation only in dry weather or with the installation site covered. For correct installation, the protective measures and For mounting of the GFK handrail, observe the provisions and instructions of the manufacturer and the local object provisions (specifications for dowels and threaded rods, supporting distance, SIA standards, etc ). Observe a standardcompliant and technically properly executed installation. Page 4 / 22

3 Required tools Crimping tool mechanical Item no. 860457, or electric Item no. 860456 Pliers to cut off cables Light barping pliers for system cables 2x2.5 mm2 Hot-air gun Circular saw Note Ensure the correct saw blade is used (V2A, V4A) Corrosion can result if the wrong blade is used. Power supply 24VDC (20-36VDC) Page 5 / 22

Large utility knife Page 6 / 22

Recommended: Device for unrolling cables Cable lug crimping pliers for press connector Screwdriver size 5 (to dismount LaneLED after wrong connection if necessary) Head lamp, measuring tape, material/tool cart, etc. 3.1 Consumables Heat shrink tube with glue (6 mm/2 mm): Item no. 010300 If appl. insulation tape 2 M Scotch no. 23, black Item no. 152743 If appl. crimp connector 1.5-2.5 hot-shrinking Raychem, blue Item no. 019875 Solder connector 1.5-2.5 heat-shrinkable NSPA, transparent Item no. 172745 Page 7 / 22

4 Montage 4.1 In general Note Examine the arrangement of the materials before assembly. Are all the parts required for assembly available? Do certain parts have to be adjusted on-site? 4.2 Mounting Mount hand rail as shown in the image. Carry out adjustments to the hand rail, such as cutting or welding, directly on-site. Page 8 / 22

5 Installation of LaneLED light bars 5.1 Mounting the adapter to the LED carrier profile Mount the adapter in the groove as shown in the drawing Note In every case, an adapter should be installed at each end of a LaneLED light bar. The distance between two adapters on one light bar should be a maximum of 30 cm. For the installation of the adapter, an M5 threaded hole has to be drilled - Drill D=4.2 - Thread cutter M5 5.2 Fitting the system cable Loop the system cable through the handrail supports 5.3 Supply line connection Page 9 / 22

Connect the connection cable and system cable with the press or solder connector Page 10 / 22

5.4 Assembly of LED light bar: variant 1 Place the looped connection line into the plastic profile Loop the LED light bar through the handrail supports, introduce into the groove and click into the adapters 5.4.1 Current collector connection The connection can be placed behind or next to the LED light bar Note The current collector may not be mounted at the height of an LED click-in adapter or holding adapter. Page 11 / 22

5.4.2 LED light bar connection Insert current collector Carry out a functional check to make sure that the LED light bar illuminates Click light bar into adapter 5.5 Assembly of LED light bar: variant 2 5.5.1 Current collector connection The connection can be placed behind or next to the LED light bar 5.5.2 LED light bar connection Insert current collector Carry out a functional check to make sure that the LED light bar illuminates Page 12 / 22

Click light bar into adapter Page 13 / 22

5.6 Diffusor mounting Determine the length of the diffusor Cut the diffusor Clean the diffusor Mount the diffusor Page 14 / 22

6 Detailed installation information 6.1 Press current collector onto the system cable with special crimping pliers Note The current collector must be at a distance of approx. 20 cm from the end of the LaneLED light bars. Install the contact element on the connector side towards the middle of the LaneLED light bars. Observe the following steps: Insert metal bracket into lower plier jaw, with the contact element in the upper plier jaw. Insert the system cable into the metal bracket and turn it until it lies flat in the bracket. The negative pole (white marking) must be aligned toward the front of the pliers and correspond with the + and - imprints on the sides of the pliers. Operate the crimping pliers. Insert the LaneLED connection cable (with the white marking aligned upwards) into the current collector until it stops. If the system cable was previously connected to a 24 VDC supply, the LaneLED light bars must now illuminate. Page 15 / 22

6.2 Finishing the system cable ends The cable end must be isolated against moisture Hazard The cable end must be cut cleanly, no loose wires Do not use common adhesive tape Open up the strands of the system cable along a length of 5 cm. Note Use a large blade for this Cut on a hard, level surface Hazard Do not damage the strand isolation when cutting Page 16 / 22

Isolate every strand separately Cut 2x 5cm shrink tube to size Use water-tight heat shrink tube with inner adhesive Shrink tube (6 mm/2 mm): Item no. 010300 Page 17 / 22

Shrink with hot-air gun (shrink temperature110 C) Compress shrink tube ends in the hot condition Hazard Do not burn your fingers! 6.3 Connecting/repairing the system cable Connect strands of the same polarity to each other + - Page 18 / 22

Open up the strands of the two system cables along a length of 5 cm Note Use a large blade for this Cut on a hard, level surface Hazard Do not insure the strand isolation when cutting Strip strands Hazard No loose wires Page 19 / 22

Crimpare i capicorda a compressione Utilizzare capicorda a compressione impermeabili con colla interna Capicorda a compressione 2,5 mm 2 termoretrattili: N art. 019875 Press connector 2. Crimp side Page 20 / 22

Shrink with hot-air gun until the insulation sleeve shrinks (shrink temperture 110 C) 6.4 Isolation of system cables A current collector that is installed incorrectly or in the wrong location will leave 2 small holes in the system cable that must be isolated against moisture Isolation of the holes (current collector) Hazard Insulation tape: Item no. 152743 Manufacturer's designation: 3 M Scotch table no. 23, black, (19 mm/19.4 m) Page 21 / 22

7 Service 7.1 Service addresses GIFAS ELECTRIC GmbH GIFAS-ELECTRIC S.r.l GIFAS ELECTRIC GmbH GIFAS-ELECTRIC GmbH Borsigstrasse 9 Via dei Filaracci 45 Pebering-Straß 2 Dietrichstrasse 2 Piano del Quercione Postfach 275 D-41469 Neuss I-55054 Massarosa (LU) A-5301 Eugendorf CH-9424 Rheineck +49 2137 105-0 +39 58 497 82 11 +43 6225 7191-0 +41 71 886 44 44 +49 2137 105-230 +39 58 493 99 24 +43 6225 7191-561 +41 71 886 44 49 www.gifas.de www.gifas.it www.gifas.at www.gifas.ch verkauf@gifas.de info@gifas.it verkauf@gifas.at info@gifas.ch 7.2 Imprint GIFAS-ELECTRIC GmbH CH-9424 Rheineck www.gifas.ch Technical changes and errors reserved. These installation instructions are the property of GIFAS-ELECTRIC GmbH and may not be copied, translated, transferred, duplicated or passed on to third parties without the previous written consent of GIFAS-ELECTRIC. Page 22 / 22