DB-DNVGL-SE DE-DNVGL-SE TT-DNVGL-SE ME-DNVGL-SE

Similar documents
Hedeager Aarhus N Denmark

Hedeager Aarhus N Denmark

Hedeager Aarhus N Denmark. Vestas V110-2 MW 50 Hz VCS Mk 10

Hedeager Aarhus N Denmark. Vestas V MW / V MW

Hedeager Aarhus N Denmark S (IEC IB)*, :2005

Hedeager Aarhus N Denmark

Hedeager Aarhus N Denmark

Avda. Ciudad de la Innovación Sarriguren (Navarra) Spain

ENERCON GmbH Dreekamp Aurich Germany ENERCON E-82 E4 2.35MW ENERCON E-82 E4 3.0MW. IIA, IEC : Amd1:2010

Avda. Ciudad de la Innovación Sarriguren (Navarra) Spain

Avda. Ciudad de la Innovación Sarriguren (Navarra) Spain G MW IEC IIIA

Avda. Ciudad de la Innovación Sarriguren (Navarra) Spain

One Earth Opp. Magarpatta City Pune, India. Suzlon S120 DFIG 2.1MW (50 Hz)

TYPE CERTIFICATE Wind Turbine

Holsterfeld Salzbergen Germany

One Earth Opp. Magarpatta City Pune, India

Bijlage 32 Technische gegevens SWT

GENERAL SPECIFICATIONS

Holsterfeld Salzbergen Germany GE

New dimensions. Siemens Wind Turbine SWT Answers for energy.

NIAGARA REGION WIND FARM PROJECT DESCRIPTION REPORT. Appendix C. Turbine Specifications

Wind Turbine Generator System. General Specification for HQ2000

ENERCON GmbH ENERCON E-66. page 1 of 6. Design. Dreekamp 5 Tel.: / Aurich Fax: / Design

Statement of Compliance on the A-Design Assessment

GRAND RENEWABLE ENERGY PARK PROJECT DESCRIPTION REPORT. Attachment C. Turbine Specifications

LA10 (480 VAC, 3-phase, 60 Hz)

SWT Turning moderate wind into maximum results

T701 (240 VAC, 1-phase, 60 Hz)

G87-ingles 14/12/06 17:44 Página 2 GAMESA G MW

BENEFITS. Maximum output at minimum cost per kwh for low wind sites. - Class IIIA/WZII.

Technical specifications. Wind Turbine GS 21 S. Power 60 kwp

SWCC Summary Report. Eveready Diversified Products (Pty) Ltd T/A Kestrel Renewable Energy. Certification Number: SWCC (240 VAC, 1-phase, 60 Hz)

Test Summary Report for the Solid Wind Power SWP25-14TG20 Small Wind Turbine

BENEFITS. Maximum unit power with excellent performance for high winds. - Class IA/WZII/WZIII.

Standard Uncertainty in AEP (kwh)

BENEFITS. Maximum output at minimum cost per kwh for medium wind sites. - Class IIA.

Ingenuity for Life Wind Power Morten Pilgaard Rasmussen. Restricted Siemens AG 2016

V MW & 2.0 MW Built on experience

ned100 Wind Turbine Generator a step towards your energy independence

EP4-Platform: E-126 EP4 / E-141 EP4. Arno Hildebrand, Programm Manager EP4 ENERCON Research & Development

Siemens Cold Climate Strategy

aeromaster wind turbines Reliable, compact, flexible and economical

General Specification

Excel 10 (240 VAC, 1-phase, 60 Hz)

V MW The future for low wind sites

Type. Transpoft and Assembly. Material

MAJOR SYSTEM FUNCTIONS

Pioneer P750/49. The Premium 750 KW Wind Turbine. green. pioneer. go go with

German-American Chamber of Commerce Offshore wind conference Jersey City, NJ October 18, 2011

V MW An efficient way to more power

ACTIVE STATOR - A MORE EFFICIENT DRIVE TRAIN CONCEPT FOR A WIND TURBINE. Dr. Makhlouf Benatmane - Director Business Development

Bright outlook for improved profitability. Direct drive wind turbine SWT Answers for energy.

Technical Documentation Wind Turbine Generator Systems /60 Hz

Guideline No.: E-04(201610) E-04 GENERATORS. Issued date: October 28,2016. China Classification Society

Siemens Gamesa AEP increase Solution

Reliable and Application specific. Slewing Drives for Wind Turbines

APPENDIX J V90 3.0MW Turbine Specifications

FD21-50 GHREPOWER. Version: 3.0

Smart Wind Turbine Solutions 2MW Platform

JOINT VENTURE: Wind Power Development Project United States of America. - Proposal Appendix -

LIFTRA COMPANY OVERVIEW LIFTRA SELF-HOISTING CRANE OVER 300 GEARBOX REPLACEMENTS WORLDWIDE

Siemens G2 platform 2.3-MW geared wind turbines. Exceptional performance, proven reliability. Answers for energy.

Renewable Energy Systems

Guideline No.: E-04(201510) E-04 GENERATORS. Issued date: October 20,2015. China Classification Society

GOLDWIND 2.5MW PERMANENT MAGNET DIRECT-DRIVE (PMDD) WIND TURBINE

Adelaide Wind Power Project Turbine T05 (AD117) IEC Edition 3.0 Measurement Report

Small Wind Energy - International Standards. Small Wind Energy International Standards. Overview

Datasheet. Pitch Motor PMSM SP260B8

Datasheet. Pitch Motor PMSM SP190C8

Datasheet. Pitch Motor PMSM SP190F8

Prepared for: Prepared by:

EXPERT REMANUFACTURED WIND TURBINE

STATE OF THE ART and NEW TECHNOLOGIES OF DIRECT DRIVE WIND TURBINES

SL2000 Series Wind Turbine

S70/1500 kw S77/1500 kw. The perfect technology for each location. Sophisticated solutions for high-efficiency wind turbines.

V MW Creating more from less

RW-30kW variable pitch wind turbine

K L E I N W I N D K R A F T kleinwind.at

Siemens G2 platform 2.3-MW geared wind turbines. Exceptional performance, proven reliability. Answers for energy.

Multi Rotor Solution for Large Scale Offshore Wind Power

Vestas Product Offering V MW at a Glance. Renato Loureiro Gonçalves Wind & Site Engineer

GE Renewable Energy. GE s 3 MW Platform POWERFUL AND EFFICIENT.

WE CANNOT SOLVE OUR PROBLEMS WITH THE SAME LEVEL OF THINKING THAT CREATED THEM.

SeaGen-S 2MW. Proven and commercially viable tidal energy generation

March Powerhouse Wind Ltd. Document Technical Summary for Thinair 102.

Bergey Excel 10 MCS Certification Summary

VENSYS. Vensys 62 The next Generation of Gearless Wind Turbines goes into Production

T u r b i n e P e r f o r m a n c e L i d a r

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Wind Generation and its Grid Conection

Product Presentation. September 09

Marine generators Proven generators for reliable power on board

Technical Specification for 12kV Powder Filled Current Limiting Fuse-Links for Use in Switchgear (In Oil)

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators

HY30-AD12.5 WIND TURBINE HY20-AD11.0 WIND TURBINE

V MW Making wind even more profitable

Siemens G4 platform 3.6-MW and 4.0-MW geared wind turbines. The offshore workhorse redefined. Answers for energy.

Cloud-connected solution for utility-scale renewable power

WE CANNOT SOLVE OUR PROBLEMS WITH THE SAME LEVEL OF THINKING THAT CREATED THEM.

Now even more silent! The first certified* small wind turbine in Germany. Produce your own electricity around the clock all year long.

Transcription:

Certificate No. COMPONENT CERTIFICATE Wind Turbine This certificate is issued to for the component wind turbine class (class, standard, year) Siemens Gamesa Renewable Energy A/S Borupvej 16 7330 Brande Denmark Offshore Direct Drive Turbine SWT-7.0-154 WT class S, IEC 61400-1:2005 + Amd1:2010 This certificate is transferred from IEC 61400-22 to IECRE and attests compliance with IEC 61400 Series as specified in subsequent pages. It is based on the following reference documents: Design basis evaluation conformity statement Dated Design evaluation conformity statement Dated Type test conformity statement Dated Manufacturing conformity statement Dated Final evaluation report Dated DB-DNVGL-SE-0074-00706-4 22.02.2017 DE-DNVGL-SE-0074-00703-7 27.06.2018 TT-DNVGL-SE-0074-00705-4 27.09.2017 ME-DNVGL-SE-0074-00704-7 27.06.2018 FER-TC-DNVGL-SE-0074-00707-8 28.06.2018 The conformity evaluation was carried out in accordance with the rules and procedures of the IECRE System www.iecre.org The component specification begins on page 2 of this certificate. Changes in the system design or the manufacturer s quality system are to be approved by the Certification Body. Without approval, the certificate loses its validity. This certificate is valid until: 21.07.2019 Approved for issue on behalf of the IECRE Certification Body: Mersudin Bajric / Bente Vestergaard Project Manager / Service Line Leader, Component Certification Hamburg 2019-03-27 DNVGL Renewables Certification Brooktorkai 18 20457 Hamburg, Germany 1/15

COMPONENT CERTIFICATE Wind Turbine Machine parameters: Power regulation: Rotor orientation: Number of rotor blades: 3 Rotor tilt: 6 Cone angle: 5 Rated power: Rated wind speed Vr: Rotor diameter: Hub height(s): Hub height operating wind speed range Vin Vout: Design life time: Software version: Pitch-controlled Upwind 7000 kw / Power Boost 7350 kw (see configuration matrix page 12 and 13) 12 m/s 154 m 120 m 3 25 m/s 25 years 137.0.0x Wind conditions: Characteristic turbulence intensity Iref at Vhub = 15 m/s: For IB: 0.14 Annual average wind speed at hub height Vave : 10 m/s Reference wind speed Vref : 50 m/s Mean flow inclination: 8 Hub height 50-year extreme wind speed Ve50: 70 m/s Electrical network conditions: Normal supply voltage and range: Low voltage side: 690 V +/- 10%V High voltage side: 33/34 kv Normal supply frequency and range: 50/60 Hz +/- 2% Voltage imbalance: Max 2% according to IEC 60146 Maximum duration of electrical power network outages: Number of electrical network outages No limits when requirements in manuals are followed Maximum 20 per year 2/15

Other environmental conditions (where taken into account): Design conditions in case of offshore WT (water depth, wave conditions, salinity, etc.): Normal and extreme temperature ranges: Relative humidity of the air: Outside: 100% Air density: 1.225 kg/m 3 Solar radiation: 1000 W/m 2 Lightning protection system (standard and protection class): Other environmental (climatic) conditions as outlined in IEC 61400-3, ed.1: 2009: Wind turbines Part 3: Design requirements for offshore wind turbines, Chapter 6.5 Other environmental conditions Normal: -10 C to +35 C Extreme: -20 C to +45 C Designed according to IEC 61400-24 Ed. 1.0, protection level 1 Corrosion class for the wind turbine acc. to ISO 12944 External structural surfaces: C5- M High Internal structural surfaces: C3 High and C4 High Interfaces The certification covers the rotor-nacelle assembly including yaw system and tower top flange including bolt connection between tower top flange and yaw ring. Interface to other components or systems and design loads See Final Evaluation Report FER-TC- DNVGL-SE-0074-00707-8 3/15

Major components: **If not otherwise stated, the certificate holder is the manufacturer. Blade: Type: B75-00 Material: Glass fibre reinforced epoxy and balsa Blade length: 75 m Number of blades: 3 Siemens Gamesa Renewable Energy A/S D1054429-186078 Blade bearing: Type: Alt. 1 Double row 4-point slewing ball bearing Rollix 13-3550-01, Rev. B Type: Alt. 2 Double row 4-point slewing ball bearing Rothe Erde 090.70.3547.004.49.1421, Rev.A Pitch System: Type: Hydraulic, 2 cylinders per blade Motor / Actuator Type: B4466/A9B10051807, Rev. 10 Pitch Controller Type: Hydraulic Siemens Gamesa Renewable Energy A/S Main bearing: Type: Alt. 1 Double row tapered roller bearing Rothe Erde GmbH 140.99.3480.000.62.1320, Rev. F Type: Alt. 2 Double row tapered roller bearing 4/15

Rothe Erde GmbH 140.99.3480.009.62.1320, Rev. B Type: Alt. 3 Double row tapered roller bearing Rothe Erde GmbH 140.99.3480.010.62.1320, Rev. A Yaw System: Drive Type: Active, 16 yaw drives Siemens Gamesa Renewable Energy Included in yaw gear Bearing Type: Plain bearing, yaw clamps Siemens Gamesa Renewable Energy D1168565-90070 Gear Type: PG 1904 PR, Ratio: 948/1 Comer Industries Alt. 1.1 N06483_3, Rev. 3 with 40 Nm motor brake Gear Type: 709 T4W, Ratio 960/1 Bongfiglioli italia S.P.A. A7090T016300 Brake Type: Friction and brake on motor Siemens Gamesa Renewable Energy Included in yaw gear motor Generator: Type Nominal Power: Rated Frequency: Synchronous, PMG, DD76 Siemens Gamesa Renewable Energy 7.4 MW (PB mode 7.7 MW) 12 Hz (PB mode 13 Hz) 5/15

Rated Speed: 10.3 rpm (PB mode 10.8 rpm) Rated Voltage: 750V Rated Current: 2 x 3.4 ka Insulation Class: F Degree of Protection: IP44 D1194372-182112 Converter: Type: Rated Voltage (grid side): Rated Current (grid side): Degree of Protection: Drawing / Data sheet / Part No: D7 type 2 SICS AA1001/1002 Siemens Generator side: 750 V Grid side: 690 V 2 x 4.0 ka IP23D SICS AA1001_1002 Ver_001 Transformer: Type: Alt.1 TDN-823A03W1K-99 Liquid-immersed Siemens AG Österreich, Transformers Weiz Rated Voltage: 34 kv / 0.69 kv Degree of Protection: n.a. Transformer rating plate 246931171, Rev.1 Type: Alt.2 Liquid-immersed TDN-823A03W1K-99 Rated Voltage: Degree of Protection: Siemens AG Österreich, Transformers Weiz 34 kv / 0.69 kv n.a. Transformer rating plate 246937021 Type: Alt.3 Liquid-immersed TDN-823A063W1K-99 Siemens Rated Voltage: 66 kv / 0.69 kv 6/15

Degree of Protection: n.a. Transformer rating plate 246931931, Rev. 1 Switchgear: Type: Alt.1 2 x NXPLUS C Wind Siemens AG Rated Voltage: 36 kv Rated current: 630 A IAC-Classification: IAC A FLR 25 ka 1 s Type: Alt.2 8VM1 Siemens Rated current: 1250 A Rated voltage: 72 kv IAC-Classification: AFLR 25 ka 1 s Drawing / Data sheet / Part no.: G81072-E0096-A Manuals: O&M manual ZOM 1036343 261095, rev. 8 User terminal for SICS on DD turbines, Operating manual, software version 129.0.0 SI 545781 218364, R16 Basic health and safety rules for access to and work in Siemens Wind Power turbines ZAI 1040332 259439 Turbine-specific safety instructions Service manual, SWT-6.0-154 ZSM 1048017 256418, R17 Service manual Service manual, SWT-7.0-154 ZSM1047720 261358 Maintenance manual SWT 7.0-154 Transport manual ZWI 1042411 137624 Preparing B75 for road transportation ZWI 1042412 234588 Rotating of B75 on Transport Equipment ZWI 1042413 234588 Mounting of B75 storage and transport equipment 7/15

ZWI 1042484 234588 Transport on port sites with B75 blade mover V1 and V2 D3179310 002/165172 B75 - Lifting instruction - Truck load/unload D3179302 006/264161 B75 Lifting instruction, Load out D1028685 001/146674 Lift instr f B75 w truss D1019598 001/144118 Trans. Instruction B75 storage D1019481 003/232404 Transportation instruction - B75 - Truck ZWI 1042180 260709 Load out B75 ZWI 1044269 265105 Seafastening of blades 1037221 86740 B75 blade, instruction f. storage 1037222 86740 B75 blade, transport instr. road 1037223 86740 B75 blade, transport instr. offshore 1037224 86740 B75 blade, lift. Instr. F. transport 1037356 86740 Instr. For B75 rotor assembly w 2 cranes D3179449 001/206327 Lift. instr. - B75 Truck load/unload, V2 (Option-2) D3179339 001/143341 B75 - Lifting instruction - rotation, V1 (Option-1) D3179397 001/206327 B75 - Lifting inst. B75 - rotation, V2 (Option-2) D1423723 002/260336 Sea trans. instruction - B75 D1192332 003/256436 Lift. instr. D6/D7 Gen., frame, adapt. D3179188 004/256436 Lift. Instr. Gen w. Metis 6.0/7.0 MW D3179187 004/261154 Mount. instr. Metis 6.0/7.0 MW D3179133 003/261154 Trans Instr gen Sea Metis 6.0/7.0 MW D3179134 003/261154 Trans Instr gen Truck Metis 6.0/7.0 MW D1193194 002/220506 Trans. instr. truck 6.0/7.0 generator D1193218 002/220506 Trans. instr. vessel 6.0/7.0 generator ZWI 1039704 102710 Loading/unloading of generator onto/from vessel - storage ZWI 1039705 102711 Loading/unloading generator onto/from truck trailer D1392422 001/257721 Upending instr. f. Gen. D6/D7 1035646 003/257358 Lift instr. for hub to 6 deg SWT6.0/7.0 D1193265 003/261154 Transport instr. truck 6.0/7.0 hub ZWI 1039708 102716 Loading/unloading of hub onto/from truck trailer/vessel D1191202 004/261154 Lift. Instr. Hub and transp. Frame 6.0/7.0MW ZWI-1043495 164677 Loading/unloading of hub with adaptor onto/from truck/vessel ZWI 1030907 C01007727 General work instruction for internal use 8/15

in Siemens Wind Power D1193268 002/190892 Transport instr. vessel 6.0/7.0 hub D1300390 002/227445 Lift. inst. rotor SWT-7.0-154 PT1/PT2 1035288 002/190892 Lift. inst. f. rotor SWT-6.0/7.0-154 ZWI 1044273 260259 Seafastening of nacelle (with hub) 1038016 88667 Ass instr f lifting yoke 6MW 1037822 123405 Lift instr Nac w gen SWT6.0 0-series ZWI 1048177 257628 Nacelle with generator on Maia frame. Loading/unloading and Transport on Trailer or vessel ZWI 1048178 257628 Nacelle with generator and hub on Maia frame. Loading/unloading and Transport on Trailer or vessel D3179701 159686 Transport instruction, 6.0MW nacelle, full D1282604 003/253892 Trans. Instr. 6.0MW nacelle Maia D1282605 003/253892 Trans. Instr. 7.0MW nacelle Maia D1190579 002/106954 Transport instr. truck 6.0 nacelle D1190642 002/106954 Transport instr. vessel 6.0 nacelle D1282608 003/253892 Trans. Instr. Maia 6.0MW nacelle full D1282609 003/253892 Trans. Instr. Maia 7.0MW nacelle full D1030284 003/220506 Lift instr f SWT6.0/7.0 Turbine D1024706 003/220506 Lift Instr f SWT6.0/7.0 Turbine w SBTS D1029536 003/220506 Lift instr f SWT6.0/7.0 w SBTS and Hydraulic D1282606 003/253892 Trans. Instr. Maia 6.0MW nac. incl. Gen D1282607 003/253892 Trans. Instr. Maia 7.0MW nac. incl. Gen ZWI 1048176 257628 Nacelle rear end on Maia frame. Loading/unloading and Transport on Trailer or vessel D1282614 001/225372 Lift. Instr. Maia frame and 6.0MW nacelle D1282615 001/225372 Lift. Instr. Maia frame and 7.0MW nacelle ZWI 1042179 259841 Lifting full tower ZWI 1044271 262186 Seafastening of full towers ZWI-1038230 94422 Loading/unloading of tower sections onto truck trailer/vessel ZWI 1042295 134907 Odin transport system Mounting and demounting ZWI 1042296 134908 Odin transport system Transport off and on shore ZWI 1042297 134909 Odin transport system Lifting and upending 9/15

ZWI-1044222 176140 Mounting of Vortex Strakes ZWI-1044224 176140 Removal of Vortex Strakes Installation manual ZWI 1040104 109037 Introduction to installation manual ZWI 1040107 109037 Pre-assembly of switchgear unit ZWI 1047521 264986 D7 Bolt tightening ZWI 517095 50278 Bolt tightening - torque and tension ZWI 1047627 257037 Mounting of generator ZWI 1047649 260259 Installation of hub ZWI 1042170 226418 Turner tool functionality test preassembly site ZWI 1042171 226418 Mounting Turner tool in nacelle (Preassembly site) ZWI 1042172 265142 Placing Turner tool container on nacelle ZWI 1042174 263218 Turner tool operation single blade installation ZWI 1042175 263218 Dismantling of Turner tool ZWI 1040115 261529 Preparing nacelle for hub installation ZWI 1040337 265037 Preparation for lifting nacelle with hub ZWI 1047690 258110 Installation of nacelle with hub ZWI 1049202 264681 Retightening of pressure fittings to brake caliper ZWI 1049246 264679 Pre-assembly retightening of fittings and pressure test on brake system ZWI 1048421 259651 Preparing nacelle and hub for single blade installation ZWI 1042181 234450 Single blade installation ZWI 1042176 132115 Blade Yoke User instruction ZWI 1047658 247222 Final tensioning of blade bolts ZWI 1040122 109037 Operating manual pitch handle with the turbines own hydraulic station ZWI 1048426 259666 Installation of helihoist ZWI 1040329 111259 Installation of lightning detectors ZWI 1047707 247222 Installation of coolers on nacelle roof ZWI 1044300 221999 Installation of wind sensors ZWI 1040330 111259 Installation of marine lantern and fog horn controller ZWI 1042374 261040 Re-assembly of nacelle after single blade installation ZWI 1048372 259346 Connecting small cable between tower and nacelle ZWI 1047866 253528 Inspection of main bearing sealings ring, 10/15

generator and hub side ZWI 1046402 209959 Pressure testing and filling of cooling system ZWI 1044919 187710 Guiding rubber collar at yaw ring into grease tray ZWI 1044285 175067 Connecting MV cable to transformer Commissioning manual ZWI1040117 109037 Connecting external generator ZWI 1040335 163460 Precommissioning tower ZWI 1048375 259374 Precommissioning nacelle with hub ZWI 1040348 259459 Final commissioning ZWI 1045401 226427 Final site test of MV system after commissioning of turbine 11/15

Configuration variant 1.1, SWT-7.0-154 (without PB) Variant Wind turbine class Rated power **Wind class IB with 25 years design lifetime and including ice loads Rotational speed Operating wind speed range 1.1 S** 7.0 MW 10.3 rpm 3 25 m/s 25 C Derating temperature Options: Variant HWRT HWRT operating wind speed range Power Boost Power boosted power Power Curve Upgrade Kit 1.1 Yes 25 31 m/s No N/A Yes, PCUK3 Yes Detect Loose Objects Further information: Variant Controller name (BHawC) Controller version (BHawC) Load set name Turbine control software version 1.1 STC-1Ctrl.dll 126.0.0.9 D770154LR301 137.0.0.x HWRT: High Wind Ride Through PB: Power Boost 12/15

Configuration variant 1.2, SWT-7.0-154 (with PB) Variant Wind turbine class Rated power **Wind class IB with 25 years design lifetime and including ice loads Rotational speed Operating wind speed range 1.2 S** 7.0 MW 10.8 rpm 3 25 m/s 25 C Derating temperature Options: Variant HWRT HWRT operating wind speed range Power Boost Power boosted power Power Curve Upgrade Kit 1.2 Yes 25 31 m/s Yes 7.35 MW Yes, PCUK3 Yes Detect Loose Objects Further information: Variant Controller name (BHawC) Controller version (BHawC) Load set name Turbine control software version 1.2 STC-1Ctrl.dll 128.0.0.10 D770154LR302 137.0.0.x HWRT: High Wind Ride Through PB: Power Boost 13/15

Scope of the present certificate In addition to the above, the standard tower internals structural assessment is included in the certification scope for this wind turbine. The tower and foundation is sufficiently documented to enable type testing and load calculations for the complete wind turbine. 14/15

Configuration matrix - Variants covered by this certificate Variant Wind Turbine Type Relevant Page 1.1 SWT-7.0-154 (without PB) page 12 1.2 SWT-7.0-154 (with PB) page 13 15/15