DECLARATION OF PERFORMANCE

Similar documents
TRIMOTERM FIREPROOF PANELS

TRIMOTERM FIREPROOF PANELS

Roofs and Façades PRODUCT RANGE. FM 4880 for internal use. Cert. No. 650a to LPS 1208 Cert. No. 650b to LPS 1181:1 Cert. No. 650c to LPS 1181:2

Declaration of Performance DoP No. 008

TRIMOTERM FIREPROOF PANELS PRODUCT RANGE

Declaration of Performance

Declaration of Performance (DoP)

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE DoP N EN

DECLARATION OF PERFORMANCE. No EN

IND panels - Wall and ceiling

Keymark Conference. Demands of Mineral Wool Manufacturers

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

DECLARATION OF PERFORMANCE OF SMOKE AND HEAT CONTROL SYSTEMS. According to Construction Products Council Directive UE N 305/2011

DECLARATION OF PERFORMANCES N TOLE 01A EN

MATERIAL DATA SHEET* ALPANA d.o.o.

GenieMat RST10 Performance Data

CE conform applications according to EN External door with thermal break System Forster unico

Polymeric membrane for roof waterproofing. Uses Roof waterproofing membrane for exposed flat roofs: Loose laid and mechanically fastened

Heradesign fine Product Data & Certificates

RockLap H&V Pipe Sections

Certificate of constancy of performance

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

Spaceloft Insulation TECHNICAL GUIDE

Certificate of constancy of performance

U Thermo datasheets May Manufactured in Springs according to ISO 9001 : 2008 South Africa

Sarnafil TS E. Polymeric membrane for roof waterproofing. Product Description

European Technical Assessment ETA-09/0355 of

AS 1252: 2016 K0 8.8 HR Structural Assembly

TECHNICAL SPECIFICATION FTP-V, FTW-V, FTU-V WOODEN PIVOT ROOF WINDOWS

Heat recovery units type GTDHR

Rectangular fire damper TFER 30. pag. C-10

Ecophon Solo Circle. System range. Size, mm. Special Fixing Thickness (THK) Inst. Diagr. Bosch, Warsaw, Poland

Heradesign superfine Product Data & Certificates

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

CIMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Mechanical Testing Issue Date

Schüco product performance certificate Aluminium sliding systems Schüco ASS 70 FD

European Technical Assessment ETA-13/0900 of 10/04/2014

CRE60 XF9499. Røgevakueringsspjæld Ø100-Ø630. AiR Ξ FORCE CRE60 XF9499 FORCE:

Table of Contents COOLMANT. 2.0 Table of Contents

Steel Spline Joint Bulkheads Junction: B-0 Class FIPRO MS 16 mm steel spline No x3 mm Construction: free-standing Sound reduction: 29 db (estima

Rectangular smoke damper (remote controlled)

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

Tillers Motor hoes (combustion engine powered)

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Table of Contents 2.0 COOLFLEX CLX. 2.0 Table of Contents

K-FLEX NAME PRODUCT June 2016 K-FLEX. Rail Application. K-FLEX thermal and acoustic insulation solutions for rolling stock market

LINTELS WITH TG. Single Spans. Lintels Supporting Truncated Girder Truss INCLUDES TG Set Back 2.4m Maximum 40 kg/m 2 90 kg/m 2

Chain-saws (combustion engine powered)

Table of Contents. EIGERFLEX -Clima. 2.0 Table of Contents

Ride-on lawnmowers (combustion engine powered)

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation?

Geomembrane Test Methods

TAS. Fire Design Example Based on European Standard ENV (Eurocode 9) TALAT Lecture pages. Advanced Level

NEW Acoustic In-Line Fans (ACQ)

Evidence of Performance Airborne sound insulation of flat roofs

ARMASOUND INDUSTRIAL SYSTEMS THE FIRST SOUND CONTROL SYSTEMS TO MINIMISE THE RISK OF CORROSION UNDER INSULATION (CUI)

ROOF FAN ROOFMASTER STEC

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

M A D E L. FOK-EIS-180 Fire dampers CE

Product Data Sheet. KS1100QCK Longspan. Applications

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

DELO -PUR 9692 Multi-purpose 2c polyurethane, cures at room temperature, high-viscous, filled

DECLARATION OF PERFORMANCE No. DoP-997

VU120. Rectangular smoke evacuation damper. V22-EN-G 08/2017

EFFICIENCY IN SOLAR APPLICATIONS

ULTEM* 1010 Resin. SABIC Innovative Plastics - Polyether Imide. Actions. General Information. Product Description

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

PKIR3G, PKIS, PKIS3G and PKIS3GA

VELUX Modular Skylights

Hedge trimmers (combustion engine powered)

UNIGLAS Tender Specifications

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

BEIJING OPERA HOUSE - STEEL SHELL - GENERAL PRESENTATION GENERAL PAUL ANDREU ARCHITECT ADP / SETEC 06 / 01

Table of Contents 2.0 EIGERFLEX CPE. 2.0 Table of Contents

EUROPEAN UNION AGENCY FOR RAILWAYS Annex 1 006REC1025 V 1.0

WELMEC External Auxiliary Power Supply of Electrical Energy Meters

TW Electric hot-air automatic welding machine. Four wheel drive and belt system assures wrinkle free welding

Technical Data Sheet. Hilti Firestop Collar CFS-C P. European Technical Approval ETA N o 10/0404. Issue 08 / Hilti Firestop Collar CFS-C P

EU Declaration of conformity

Plastocell Kunststoff GmbH Mühlweg Schifferstadt Phone +49 (0) 62 35/

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION

Bevent Rasch BSK6. - Fire /04/2017

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Heat Exchangers (Chapter 5)

Folding Sliding System SF55c

CU-LT. Optimised rectangular fire damper up to C3-EN-J-06/2018

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

SPEC No.: ZP REVISION: 1.1 ZP ELECTRON CO.,INC. Designer. Division. Approver

The Passive Fire Protection Handbook I Structural steel Corrugated steel Concrete

Powerful centrifugal fans for universal use: The product ranges TEM and REM

RAFTERS. Single and Continuous Spans

Manufacturer: Address: ZIP Code: City: Country: VAT #: Signatory, Name: Signatory, Title: Phone: Fax: WWW: Head of Engineering:

INDUSTRY PROCESS AND AUTOMATION SOLUTIONS. Technical Bulletin

C DECLARATION OF PERFORMANCE. 1. Unique identification code of the product-type The list of products can be found in the Appendix

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

Product Evaluation Report

(This Instruction Manual)

Installation Manual Sectional door with rear springs (LF 70) Conform TÜV / CE EN

Transcription:

DECLARATION OF PERFORMANCE No. DoP Trimoterm Power T, 26.04.2018_en 1. Unique identification code of the product-type: Trimoterm Power T, type FTV, FTV H, FTV HL, SNV 2. Intended use/es: Self-supporting double skin metal faced insulating sandwich panels. Roofs and roof cladding, External walls and wall cladding, Walls (including partitions) and ceilings within the building envelope. 3. Manufacturer: Trimo d.o.o., Prijateljeva cesta 12, 8210 Trebnje, Slovenia. 4. Authorised representative: Not applicable 5. System/s of AVCP: System 1 (reaction to fire) System 3 (other properties) 6a. Harmonised standard: :2013, Self-supporting double skin metal faced insulating panels Factory made products Specifications Certificate of constancy of performance issued by NB 1404-ZAG Ljubljana, No. 1404 - CPR - 2115. Notified body/ies: 1404 ZAG Ljubljana 1/5

7. Declared performances for Trimoterm Power T, type FTV, FTV H, FTV HL, SNV MASS TYPE FTV FTV H, FTV HL SNV 50 13,5 13,7-60 14,4 14,6 15,7 80 16,2 16,4 17,5 100 18,0 18,2 19,3 120 19,8 20,0 21,1 133 21,0 21,2-150 22,5 22,7 23,9 172 24,5 24,7 25,9 200 27,0 27,2 28,4 220 29,8 29,0-240 30,6 30,8-250 31,5 31,7 - WRINKLING EXTERNAL SIDE - IN THE SPAN 50 108 94-60 110 94 313 80 113 102 286 100 117 110 258 120 120 118 231 133 122 118-150 125 118 231 172 129 118 231 200 134 118 231 220 138 112-240 141 106-250 143 103 - kg/m 2 WRINKLING EXTERNAL SIDE - IN THE SPAN (ELEVATED TEMPERATURE) 50 100 87-60 102 87 313 80 105 95 286 100 109 102 258 120 112 110 231 133 113 110-150 116 110 231 172 120 110 231 200 125 110 231 220 128 104-240 131 99-250 133 96 - WRINKLING EXTERNAL SIDE - AT CENTRAL SUPPORT 50 86 75-60 87 74 313 80 87 79 286 100 88 83 258 120 88 86 231 133 87 84-150 86 81 231 172 86 79 231 200 86 76 231 220 86 69-240 85 64-250 84 61 - DoP Trimoterm Power T, 26.04.2018_en 2/5

WRINKLING EXTERNAL SIDE - AT CENTRAL SUPPORT (ELEVATED TEMPERATURE) 50 80 70-60 81 69 313 80 81 73 286 100 82 77 258 120 81 80 231 133 81 78-150 80 76 231 172 80 74 231 200 80 70 231 220 80 65-240 79 59-250 78 57 - WRINKLING INTERNAL SIDE - IN THE SPAN M M2 S, G, V, V2, V6 T 50-126 94-60 - 129 94-80 - 134 102-100 - 140 110-120 - 145 118-133 - 144 118-150 - 144 118-172 - 143 118-200 - 142 118-220 - 141 112-240 - 140 106-250 - 140 103 - WRINKLING INTERNAL SIDE - AT CENTRAL SUPPORT M M2 S, G, V, V2, V6 T 50-113 85-60 - 115 84-80 - 117 89-100 - 119 94-120 - 120 98-133 - 117 96-150 - 114 93-172 - 110 91-200 - 105 87-220 - 102 81-240 - 98 74-250 - 97 71 - MECHANICAL RESISTANCE REDUCED LONG TERM MODULUS (CORE) COMPRESSIVE (CORE) 50 0,06 0,03 3,70 0,07 60 0,05 0,03 3,70 0,07 80 0,05 0,03 3,70 0,07 100 0,05 0,03 3,70 0,07 120 0,05 0,03 2,70 0,07 133 0,05 0,03 2,70 0,07 150 0,05 0,03 2,70 0,07 172 0,05 0,03 2,70 0,07 200 0,04 0,02 2,70 0,06 220 0,04 0,02 2,70 0,06 240 0,04 0,02 2,70 0,06 250 0,04 0,02 2,70 0,06 TENSILE 0,12 DoP Trimoterm Power T, 26.04.2018_en 3/5

CREEP COEFFICIENT (ALL ES) CREEP COEFFICIENT Creep coefficient 2 000 h 0,5 Creep coefficient 100 000 h 0,8 THERMAL TRANSMITTANCE FTV, FTV H, FTV HL SNV 50 0,69-60 0,58 0,58 80 0,45 0,44 100 0,36 0,36 120 0,30 0,30 133 0,28-150 0,25 0,24 W/m 2 K 172 0,21 0,21 200 0,19 0,18 220 0,18-240 0,16-250 0,15 - FIRE RESISTANCE* WALL* CEILING** ROOF*** FTV FTV H, FTV HL FTV SNV SNV 50 NPD NPD NPD - - 60 NPD EI20 NPD REI30 REI30 80 EI60 EI60 NPD REI30 REI30 100 EI120 EI120 EI120 REI120 REI120 120 EI120 EI120 EI120 REI120 REI120 133 EI120 EI120 EI120 - - 150 EI180 EI180 EI120 REI120 REI120 172 EI180 EI240 EI120 REI120 REI120 200 EI180 EI240 EI120 REI120 REI120 220 EI180 EI240 EI120 - - 240 EI180 EI240 EI120 - - 250 EI180 EI240 EI120 - - *Fire resistance for wall use type defined on base of EN 1364-1 testing on 3 x 3 m furnace, Classified on base of EN 13501-2 norm with additional consideration of - Annex C.2.4. and EN 15254-5 - Ch.5 - T2. **Fire resistance for ceiling use type defined on base of EN 1364-2 testing on 3 x 4 m furnace, Classified on base of EN 13501-2 norm with additional consideration of - Annex C.2.4. ***Fire resistance for roof use type defined on base of EN 1365-1 testing on 3 x 4 m furnace, Classified on base of EN 13501-2 norm. AIRBORNE SOUND INSULATION Rw (C;Ctr) FTV, FTV H, FTV HL SNV 50 NPD - 60 NPD NPD 80 NPD NPD 100 NPD NPD 120 30 (-1;-3) NPD 133 30 (-1;-3) - 150 30 (-1;-3) NPD db 172 30 (-1;-3) NPD 200 30 (-1;-3) NPD 220 30 (-1;-3) - 240 30 (-1;-3) - 250 30 (-1;-3) - WATER PERMEABILITY WALL ROOF FTV, FTV H, FTV HL SNV All Class A (1200 Pa) Class B (900 Pa) AIR PERMEABILITY WALL ROOF FTV FTV H, FTV HL SNV All n = 3,0: C= 0,0000000011 n = 0,8055: C= 0,008996 n= 1,00: C= 0,00019 DoP Trimoterm Power T, 26.04.2018_en 4/5

OTHER CHARACTERISTICS - ALL ES CHARACTERISTICS PROPERTIES CORE TYPE, DENSITY Stone wool, 90 kg/m 3 THERMAL CONDUCTIVITY 0,038 W/mK EXTERNAL AND INTERNAL STEEL GRADE S320GD EXTERNAL SHEET 0,5-0,8 mm EN 10346 INTERNAL SHEET 0,4-0,8 mm EXTERNAL COATING SP, HDP, PUR, PUR-PA, PVDF, PVC(P) EN 10169 INTERNAL COATING SP, HDP, PUR, PUR-PA, PVDF, PVC(P), PVC(F), PET(F) EN 10169 EXTERNAL FIRE PERFORMANCE (ROOF) BROOF (t1,t2,t3) EN 13501-5 REACTION OF FIRE A2-s1, d0 EN 13501-1 SOUND ABSORPTION NPD db DURABILITY ALL COLORS Pass RESISTANCE TO POINT LOAD 1,5 kn / 5 m REPEATED ACCESS LOAD NPD WATER VAPOUR PERMEABILITY Impermeable Hazards identification: according to GHS/CLP EC N 1272/2008 the product is not classified. 8. The performance of the product identified above is in conformity with the set of declared performance/s. This declaration of performance is issued, in accordance with Regulation (EU) No 305/2011, under the sole responsibility of the manufacturer identified above. Signed for and on behalf of the manufacturer by: Silvo Štih Quality Assurance & HSE Trebnje, 26.04.2018 DoP Trimoterm Power T, 26.04.2018_en 5/5