AIR CONDITIONING Managing condensate

Similar documents
CONDENSATE REMOVAL PUMPS

The multi-feature powerhouse

Sentinel D-Box Twin Fan

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

NEW Slimpak EC Box Fan (SLPT EC)

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Sentinel D-Box Single Fan

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

CEILING CONCEALED SPLIT SYSTEM C SERIES

QOF-2/3/5/7.5. Parts Manual. Direct Drive Oil-free scroll compressors. Manual No November 2014 Edition

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

NEW. Wall controls. YFCN Fan Coil Units. Technical Guide - for internal distribution only

NCF fans 50 Hz. Protection class IP 55

Set 2 Mini Pust APB50B

NEW Acoustic In-Line Fans (ACQ)

NCF fans 60Hz. Protection class IP 55

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

TD-SILENT Series (160 to 1000 models)

A E R Z E N S C R E W C O M P R E S S O R S

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

CM25-1 A-R-G-E-AQQE C-A-A-N

Centrifugal fan with highly efficient EC drive motor

CM15-1 A-R-I-V-AQQV C-A-A-N

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

CENTRIFUGAL FAN COIL UNIT VCE

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

CLASSEQ LTD. Spares manual P500 AS

ACOUSTIC CABINET FANS CVAB / CVAT Series

CMB-SP 3-28 I-C-A-C-A-A

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

CM5-5 A-R-G-V-AQQV F-A-A-N

CM10-3 A-R-G-V-AQQV F-A-A-N

CM5-9 A-R-I-E-AQQE F-A-A-N

CME5-5 A-R-I-E-AQQE S-A-D-N

SILENT MV Ultra Quiet In-line Fans

TD-ECOWATT AND DECOR-ECOWATT Series

CM10-1 A-R-A-E-AQQE F-A-A-N

CM3-5 A-R-I-E-AQQE F-A-A-N

CM5-5 A-R-A-E-AVBE C-A-A-N

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Cert. n 0545 Carisma CRC Fan Coil Unit The Ultra Quiet Fan Coil TECHNICAL GUIDE

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CLASSEQ LTD. Spares manual P500

CM1-8 A-R-I-E-AQQE F-A-A-N

CM1-2 A-R-A-E-AQQE F-A-A-N

CM5-6 A-R-A-E-AQQE C-A-A-N

CM3-11 A-R-G-E-AQQE F-A-A-N

NCF 60 Hz. Protection class IP 55

CM5-11 A-R-G-E-AQQE F-A-A-N

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

Rheem Spare Parts Manual. Parts List 740 series PC (before 23/6/2010), PC (before 19/7/2010)

CMB-SP 5-28 I-C-A-C-B-A

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

CME1-4 A-R-I-E-AQQE S-A-D-N

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

CMB-SP 1-54 I-C-A-C-C-A

technical catalogue tetris KW Chiller and heat pumps air/water

Data sheet. Page: 1 / 7. ETL GG AV11D BKSBIE3M Inline pump. Operating data. Design

CLASSEQ LTD. Spares manual P500A

CM1-6 A-R-I-E-AQQE F-A-A-N

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

CM3-6 A-R-G-E-AQQE C-A-A-N

D M S 760 C01 A A 1 1

Technical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10

MOBILAIR M 27/M 31. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 1.90 to 3.15 m³/min (67 to 110 cfm)

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

AHN 064 to 304 EHN/CHN 064 to 304

NBE40-125/139 AS-F2-A-BAQE

CM10-3 A-R-A-E-AVBE F-A-A-N

CLASSEQ LTD. Spares manual P500 AS WS

Heat recovery units type GTDHR

CRE10-02 A-A-A-E-HQQE 1x HZ

NB /438 A-F1-A-GQQE

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

BASTONE (dual) fancoil Units

Carisma The Ultra Quiet Fan Coil

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

CM5-5 A-R-A-E-AVBE F-A-A-N

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

series RVV Variable flow rate controllers

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

GLOBAL STANDARD COOLER

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Transcription:

www.sauermann.co.uk AIR CONDITIONING Managing condensate

Pump selection chart Equipement Location Wall mounted Cassette Multi cassette Conditioning cabinet ALTEZZA DI MANDATA (m) Floor standing Ducted unit Suspended ceiling unit Inside the unit Inside ducting Wall mounted Floor mounted False ceiiling p.3 OMEGA PACK x x p.3 Si-20 x x x p.4 DELTA PACK x x p.4 Si-10 UNIVERS L x x x x x p.5 Si-30 Si-33 x x x x p.6 Si-60 x x x x x p.7 Si-82 x x x x x p.8 SI 1805 x x x x p.8 SI 1830 x x x x x x x p.9 SI 2052 x x x x p.10 PE5000 PE5100 PE5200 x x x Actual flow rates DISCHARGE HEAD (m) 18 16 14 12 10 8 6 4 2 Si-33 Si-30 / Si-60 /Si-10 UNIVERS'L Si-20 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 FLOW RATE (l/h) FLOW RATE (l/h) 500 450 400 350 300 250 200 150 100 50 0 SI 1805 Si-82 SI 1830 1 2 DISCHARGE HEAD 3 (m) 4 5 2

NEW OMEGA PACK The under the unit pack For mini-split air conditioning Ref : OP20CE01UN23 22 dba Easy installation Complete installation kit with premounted pieces. Reliability The Drain Safe Device included to prolong the life of the pump. Operation level Anti-vibration rubber dampers. Installation video Kit contents Si-20 piston pump with detection unit (0.63 m cable), 2 anti-vibration rubber dampers, clear pvc tubing int. Ø 6 mm fitted with a drain safe device - Power cable 1.5m (2 power wires, 2 safety wires)- Shell (2-part: backplate & cover) - Screws & plugs for affixing backplate 90 rubber elbow Ø int.15 mm x L 152 mm - Vent tube - 3 Double Wire Clamps - 3 Tie Wraps. Si-20 Piston pump Si-20 NEW For wall mounted and floor standing units Maximum flow-rate 20 l/h 10 m (flow rate= 4 l/h) Ref : SI20CE01UN23 Pump sound level @ 1 m 22 dba Detection levels (mm) ON : 16, OFF: 11, Safety : 19 Mains supply 230 V ~ 50 Hz 14 W Thermal protection 115 C (auto-reset) Easy installation Slim design. Rubber damper : allows the pump to be put directly inside the unit. Protection IP20 *To EN ISO 3744. LNE measurement, on pump running with water, out of application. Installation video 3

DELTA PACK Piston pump and trunking system For wall-mounted air-conditioning units Ref : 80X50 mm white RAL 9010 : DP10CE01UN23 80x60 mm cream RAL 9001 : DP10CE02UN23 80x60 mm white RAL 9003 : DP10CE04UN23 NEW 22 dba Complete system Pump and trunking kit for a quick and easy solution. Multiple choice 80x50mm or 80x60mm, white or cream. Can be mounted to either side of the air conditioning unit. Operation level High energy absorbing foam inside the elbow, anti-vibration insulation. Installation video Kit contents : Si-10 UNIVERS L pump 1 m long discharge pipe with foam insulation and Drain-Safe Device connector - Lockable, plug-in 1.5 m cable with NC safety contact wire 2-part elbow (base and cover) 750 mm duct with Elbow/Duct and Elbow/ Split joiners - Ceiling fitting - 0.5 m long flexible hose for connection to split - Vent pipe - 6 fixing plugs and screws - 2 hose clips. Si-10 UNIVERS L Replacement pump for trunking corner pieces For wall-mounted air-conditioning units Ref : SI10CE03UN23 Maximum flow-rate Si- 10 UNIVERS L 20 l/h 10 m (flow rate= 4 l/h) Pump sound level @ 1 m 22 dba Detection levels (mm) ON: 16, OFF: 11, Safety : 19 Mains supply 230 V ~ 50 Hz 14 W Thermal protection 115 C (auto-reset) Universal Replacement pump for the majority of pump in trunking systems. Protection IPX4 *at 1m according to EN ISO3744 4

Si-30 / Si-33 Mini pumps with float detection For air conditioning systems Ref : SI30 : SI30CE01UN23 / Si-33 : SI33CE01UN23 Manufactured for purpose Patented pump technology designed for discharging contaminated condensates produced by air-conditioning systems. 100% operating cycle. Reliable No risk of siphoning, due to the pre-installed Drain-Safe Device. Versatile installation Mounting bracket gives the installer flexibility when siting the pump and can be fixed to the wall, pipework or ceiling suspended Installation video Kit contents : Pump - Transparent PVC tube int. Ø 6 mm L 1 m, fitted with Drain-Safe Device connector - Anti-vibration mounting bracket - Lockable, plug-in 1.5 m cable with NC safety contact wire - 6 cable ties - For Si-30 / Si-33 : Detection block with floats - 90 connector int. Ø 15 mm L 60 mm, vent pipe, mounting rail, adhesive. For Si-30 Detect+ : mounting bracket - straight connector - 1,5 m extension cable - rubber elbow 90 Øint.15 x L 152mm - vent tube Ø int 6 x L 75 mm - 2 self drilling screws + 2 anchors Si-30 Detect+ Condensate removal pump with electronic detection unit For air conditioning systems Si-30 Si-33 Ref : SI30CE04UN23 NEW Electronic detection unit Maximum flow-rate 20 l/h 30 l/h Maximum suction height 3 m 4 m 10 m (flow rate = 4 l/h) > 13 m (flow rate = 8 l/h) Pump sound level @ 1 m 20 dba 34 dba Patented detection unit with probes : low maintenance and high reliability Easy installation Detection levels (mm) ON : 16, OFF: 11, Safety : 19 Mains supply 230 V ~ 50 Hz 14 W 230 V ~ 50 Hz 21 W Protection IP20 *To EN ISO 3744. LNE measurement, on pump running with water, out of application. Si-30 : can replace SI3080, SI3100, SI3200 Si-33 : can replace SI1730 5 5

Si-60 Piston pump with 0.5 L tank For ducted air conditioning systems Ref : SI60CE01UN23 Lockable cable Twist lock power cable for a secure connection Innovative detection Intergrated float detection system reliable in all types of environment. Multi Purpose Top and bottom inlet. Can be semisubmersed in a condensate drain pan. Kit contents Pump - Lockable, plug-in 1.5 m cable with NC safety contact wire - Installation kit: adapter int. Ø 15-20- 24-32-40 mm, rubber 90 connector int. Ø 15 mm L 60 mm, plastic 90 connector for 6 mm int. Ø flexible tube, 1 off 2.5 100 mm cable tie. Maximum flow-rate Si-60 20 l/h 10 m (flow rate = 4 l/h) Pump sound level @ 1 m < 38 dba Detection levels (mm) ON : 28, OFF : 24, Safety : 35 Mains supply 230 V ~ 50 Hz 14 W Protection IPX4 * To EN ISO 3744. LNE measurement, on pump running with water, out of application. 6

Si-82 Centrifugal pump with 2 l tank For cassette and fan coil air-conditioning systems. Ref : SI82CE01UN23 Plug in power cable Easy to maintain and replace. Versatile installation Provides installer flexibility when fitting the pump. Can be fixed to the wall, flat surface or ceiling suspended. Easy hydraulic connection 4 inlet holes Ø 30 mm. Reversible tank. Kit contents One-piece centrifugal pump - Tank (2 l) - Built-in 10 mm ext. Ø non-return valve - Plug-in cable: power (2 m, European IEC socket) and safety contact (1.5 m, bared wires) Straight connector ext. Ø 10 mm / ext. Ø 6 mm; 2 plugs + 2 screws. Maximum flow-rate Si-82 500 l/h 5 m (flow rate 50l/h) Pump sound level @ 1 m < 45 dba Detection levels (mm) ON : 53, OFF : 42, Safety: 64 Mains supply 230 V ~ 50/60 Hz - 70 W Protection IP20 * To EN ISO 3744. LNE measurement, on pump running with water, out of application. 7

SI 1805 / SI 1830 Centrifugal pumps with 0.5 l tank For cassette and fan coil air-conditioning systems Ref : SI 1805 : SI1805SIUN23 SI 1830 : SI1830SCUN23 High performance Capable of discharging highvolume of condensates evacuated per hour. Compact Compact design that can sited in confined spaces. Installation in any location SI 1805 : compact design SI 1830 : can be install without the tank. Kit contents SI 1805 : Pump - 2 screws - 2 plugs Power cable: 2 m, European IEC plug; safety contact cable: 1 m, 2 wires (NC contact). SI 1830 : Pump with 0.5 l tank Power cable: 1.5 m, European IEC plug; safety contact cable: 1 m, 2 wires (NC contact) - Installation kit: 2 screws + 2 plugs, 5 m of transparent PVC hose 10 mm int. Ø, flexible adapter 15-24-32-40 mm Ø. Dimensions SI 1805 : L 195 x W 130 x H 132 mm SI 1830 : L 190 x W 80 x H 100 mm SI 1805 SI 1830 Maximum flow-rate 500 l/h 400 l/h 5,4m 3,7 m Pump sound level @ 1 m 47 dba 43 dba Detection levels (mm) ON : 27, OFF: 21, Safety : 32 ON : 32, OFF : 25, Safety: 39 Mains supply 230 V~ 50/60 Hz -90 W 230 V~ 50/60 Hz -75 W Protection IP20 IPX4 * To EN ISO 3744. LNE measurement, on pump running with water, out of application. 8

Si-2052 Centrifugal lift pump For cassette air conditioning systems Ref : SI2052SIUN23 Replacement Can be used as a replacement pump for most cassette systems. Kit contents Centrifugal pump 250 mm overmoulded cable 850 mm cable with hard-wired connector - Detector (DET01550, 900 mm cable) + stainless-steel fixing screw. Maximum flow-rate SI 2052 100 l/h at 200mm 0.9 m (24l/h) Pump sound level @ 1 m 30 dba Detection levels (mm) Safety : 18 Mains supply 230 V ~ 50/60 Hz - 14 W * To EN ISO 3744. LNE measurement, on pump running with water, out of application. 9

PE 5000 / PE 5100 PE 5200 Peristaltic pumps PE 5000 For air conditioning applications up to 8 kw Ref : PE5000 : PE5000SIUN23 PE5100 : PE5100SIUN23 PE5200 : PE5200SIUN23 PE 5100 PE 5200 Easy maintenance Quick fit replacement head and tubes. 3 detection systems PE 5000 : compressor signal PE 5100 : temperature differential sensors PE 5200 : float detection unit Kit contents Pump - Cable: 1.7 m, including 2 wires for power supply (P &N), 1 wire for compressor signal - Easy «1 screw» sliding plastic bracket - Ø 15 mm to Ø 6 mm adaptor + pale yellow rubber Ø 15 x 35mm (PE5003) Additional kit for PE 5100 : 2 thermal probes with 3.5m cable: Red cap for ambient air.blue cap for fresh air. Maximum flow-rate Pump sound level @ 1 m PE 5000 / PE 5100 / PE 5200 6 l/h 2 m 30 dba Additional kit for PE 5200 : detection unit (SI2958, 1.5m cable) - Detection unit installation kit : Pale yellow rubber (Ø 15 x 35mm). Vent tube Øint 4 x L 75 mm. Mounting rail. Adhesive. Detection levels (mm) ON : 16, OFF: 11, Safety: 19 Mains supply 230 V~ 50/60 Hz -75 W Protection IPX4 * To EN ISO 3744. LNE measurement, on pump running with water, out of application. 10 10

ACCESSORIES ACC00205 ACC00204 ACC00105 Pump Discharge Hoses Pump Discharge Hose Ø 6 mm ACC00105 : 5 m - ACC00150 : 50 m - ACC00151 : reinforced, 50 m Clear PVC tubing for connecting the pump to the discharge outlet i.d. 6 mm (1/4 ) Pump Discharge Hose Ø 10 mm ACC00125 : 25 m - ACC00126 : reinforced, 25 m Clear PVC tubing for connecting the pump to the discharge outlet i.d. 10 mm (3/8 ) Connectors Straight and elbow connectors ACC00204 : for Ø 6 mm hose - ACC00213 : for Ø 10 mm hose Straight and elbow connectors for connecting hoses together. 5 straight, and 5 elbow connector pieces per package. 10 pieces (ACC00204, 5 x elbow, 5 x straight connectors ) - 5 pieces (ACC00213, straight) «T» Connector ACC00211 : Ø 6 mm To make the connection between 3 tubes. For tubes Ø 6 mm int. (¼ ) 5 pieces Self Sealing Fittings ACC00205 : for use with Ø 6 mm tubing. - ACC00215 : for use with Ø 10 mm tubing. Self sealing fittings for condensate discharge tubing. 6 pieces (ACC00205) - 3 pieces (ACC00215) Spare Parts Detection unit SI2958-003 For replacing the detection unit when necessary Inlet : Ø 15mm int. Outlet : Ø 6 mm int. (1/4 ). For pumps with detection unit. Non-return valve ACC00801 For replacing the non-return valve when necessary in Si-82, SI 1805, SI 1830. Replacement tube PE5002 Replacement tube of the peristaltic pumps. 11

DOCEN000 For any further information: www.sauermann.co.uk Sauermann UK Ltd. Trident Business Park 7-9 Amy Johnson Way, Blackpool : England / FY4 2RP Tel : (+44)1253 340170 Fax : (+44) 1253 340179 E. info.uk@sauermanngroup.com