- Application A Mixing Setpoint Control 153. Mechanical. Electrical 12/08

Similar documents
- Wiring Brochure Universal Reset Module 422

- Wiring Brochure Universal Reset Module 422e

- Wiring Brochure tekmarnet 4 Thermostat 545

- Wiring Brochure Mixing Expansion Module 440

- Data Brochure D 156. Difference Setpoint Control 156. Item 06/10

SetPoint 150 Controller Installation Manual

SetPoint 501 and 501s Controllers Installation and Operation Manual

- Wiring Brochure Zone Manager 335

- Wiring Brochure Zone Manager 336

- Wiring Brochure tn4 Gateway 483

Installation & Operation Manual

Installation & Operation Manual

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

BAPI-Stat 3 Room Sensor

3-Way Linked Globe Valve Assemblies with Linear Series Actuators

Selection Guide. Vx-7000 & Vx-9000 Series Mx4x-6xxx & Mx4x-7xxx Series. Globe Valve Assemblies. Actuator/Linkage Assemblies

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

Planning Low Voltage Layouts

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

YCCS Zone/Bypass Damper Assembly

YCCS Zone/Bypass Damper Assembly

V4043 and V4044 Motorized Valves

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

CALEFFI. Motorized ball valves with 3-wire control series ACCREDITED 01131/13 NA. Replaces 01131/07 NA

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

AV-8020 Series Floating Control Actuated Valve

CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)

M400A (VB), M800A (VB), M1500A (VB) General Instructions. Features. Schneider Electric Forta Globe Valve Actuators and Assemblies

9070T150D1 Industrial Control Transformer, 150VA

MS Application. Features. Proportional Valve Actuator General Instructions

Direct Coupled Damper Actuator Model MY6050A1001

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

VA-4233-AGx Series Electric Valve Actuators

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

ELECTRONIC THERMOSTAT: T901

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

Variable speed drives

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

ABB PSPG-E7 MODAKOND More efficient and dynamic unit control. ABB Group May 8, 2014 Slide 1 ABB

Load and Motor Switches, Load-Break Switches Series 8544

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

VA-4233-GGx Series Electric Valve Actuators

STEAM INJECTION HUMIDIFIER LIVESTEAM. Submittal Drawings

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SE8300 Series Installation Guide 24 Vac Low Voltage

MF-22xx3. Application. Features. Floating Valve Actuator General Instructions

SUPERSEDES: August 1, 2003 EFFECTIVE: August 15, 2005 Plant ID#

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

Photovoltaics. MPI Hybrid Series

SUPERSEDES: August 15, 2005 EFFECTIVE: June 1, 2009 Plant ID#

SUPERSEDES: August 15, 2005 EFFECTIVE: June 1, 2009 Plant ID#

Load and Motor Switches, Load-Break Switches Series 8549

as a voltage from 0 to 10 V or as a current from 4 to 20

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

SAV Electronic Valve Actuator

CAPCO BOILER TRIM ADD A DECIMAL BEFORE ENTERING THE PART# ON WOE

Accessories. UP timer. Timer control. Approvals. UP Series

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

825-P Modular Protection System for motors Specification Guide

Description. functions including single duct pressure dependent or pressure independent systems.

How to Select the RE Industrial Actuator Part Number

LF Series At A Glance

Extending A99 Sensor Cables

Load and Motor Switches, Load-Break Switches Series 8544

GE Measurement & Control

Minimum 27 in-lb Torque

Installation Instructions

Product features & Overview. KA Linear actuators

Laboratory Room Controller

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

LF Series Spring Return Direct Coupled Actuator

Technical data. Safety notes

R EGI S TERED. Function

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Zone Valves and Parts (Honeywell)

Power Switching Devices

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

EAS822 (Contrac) Power Electronic Unit

ESBE Series 60 Electronic Motor Actuator (Combined with ESBE 3&4-way rotary valves)

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

CALEFFI. Mixing valves and actuators series 01169/17 GB. replaces dp 01169/09. Function

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

V4062A,B,D HI-LO-OFF Fluid Power Gas Valve Actuator

Product features & Overview. N1 - N4 A Rotary and part-turn actuators

M9203-xxx-2(Z) Series Electric Spring-Return Actuators

Transcription:

Mixing Setpoint ontrol - Application A -1 12/08 Mechanical 24 V (ac) SW2 SW1 V1 Additional zones Electrical M1 = Actuating Motor 741-24V (ac) Floating Action = Heating Load Pump = System Pump = Mix Supply sor = Boiler Return sor SW1 = Heating Pump ontrol Switch SW2 = Boiler ontrol Switch V1 = 3-way Mixing Valve 710-714 10A 10A 1 2 3 4 5 6 7 8 Power Pwr Opn ls om Sup Ret - R+ Mix Mix Mix SW2 T T Boiler 1 2 3 M1 24 V (ac) SW1 R L N Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added.

Technical Data A -1 Mixing Setpoint ontrol Floating Literature A 's, D, D 001, D 070 ontrol Microprocessor control; This is not a safety (limit) control. Packaged weight 0.66 lb. (300 g), Enclosure, PV plastic Dimensions 4-3/4 H x 2-7/8 W x 7/8 D (120 x 74 x 22 mm) Approvals SA US, SA 22.2 No 24 and UL 873, meets class B: IES & F Part 15 Ambient conditions Indoor use only, -20 to 120 F (-30 to 50 ), < 90% RH non-condensing. Power supply 24 V (ac) ±10%, 50/60 Hz, 3 VA or 24 V (dc) ± 10%, 0.03 A Relays 240 V (ac) 10 A, 1/3 hp sors NT thermistor, 10 kω @ 77 F (25 ±0.2 ) ß=3892 included: Universal sor optional: Universal sor Programmed settings Ten year memory backup ontrol accuracy ±0.5 F (±0.3 ) with up to 500 feet (150 m) of 18 AWG wire to sensors. Temperature display -85 to 302 F (-65 to 150 ) Supply (1) Setpoint -40 to 239 F (-40 to 115 ) Throttling Range 16 to 66 F (9 to 37 ) Boiler Return (2) -40 to 239 F (-40 to 115 ) Temperature display Fahrenheit / elsius Meets lass B: anadian IES F Part 15 Made in anada tektra 906-07 PRGM 1 2 Supply (1) O Throttling Return (2) Item Mixing Setpoint ontrol Floating Action Power 24 V (ac) ± 10% 50/60 Hz 3 VA 24 V (dc) ± 10% 0.03 A Relay 240 V (ac) 10 A 1/3 hp 1 2 3 4 5 Power ls R+ Pwr Mix Opn Signal wiring must be Mix rated at least 300 V Mix F 6 7 8 om Sup H1096F Date ode Ret System Operation & Specifications The Mixing Setpoint ontrol controls a 4-way mixing valve in order to maintain a preset mixed supply temperature. With the addition of the optional Universal sor () on the boiler return, the also provides Boiler Return Protection. Piping and Heat Source Details The system is piped in a primary - secondary arrangement using a 4-way mixing valve. The boiler and the boiler loop pump () are controlled by the boiler's control package. The system pump () operates continuously providing flow through the system. Mixing Operation The modulates the mixing valve using a Floating Action Output. The installer / operator is required to set the Supply temperature, Throttling range and Return temperature limits using the digital display in the control. With this information, the control modulates the mixing valve in order to maintain the desired setpoint. Boiler Protection As the boiler return temperature approaches the Return temperature setting, the begins closing the valve in order to limit the amount of cool water returning to the boiler. In this situation, the protection of the boiler takes priority over maintaining the supply temperature. Additional Functions Additional control functions are listed in the table in the Setpoint ontrols section of the Product atalog I 000. ontrol Systems tekmar ontrol Systems Ltd., anada tekmar ontrol Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road Vernon, B.. anada V1B 3K4 Tel. (250) 545-7749 Fax. (250) 545-0650 Product design, software and literature are opyright 2008 by: tekmar ontrol Systems Ltd. and tekmar ontrol Systems, Inc. All specifications are subject to change without notice. Printed in anada. A -1-12/08.

Mixing Setpoint ontrol - Application A -2 12/08 Mechanical 24 V (ac) Heat Pump Unit Zone 1 Heat Pump Unit Zone 2 Heat Pump Unit Zone 3 Max. 4 pipe diameters apart Supply sor () M Actuating Motor 4-Way Mixing Valve Boiler Return sor () Electrical = Boiler Pump = System Pump = Supply sor = Boiler Return sor 1 = Actuating Motor 10A 10A 1 2 3 4 5 6 7 8 Power omopn ls om Sup Ret - R+ Mix Mix Mix 1 2 3 om Opn ls 1 L N 24 V (ac) R Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added.

Technical Data A -2 Mixing Setpoint ontrol Floating Literature A 's, D, D 001, D 070 ontrol Microprocessor control; This is not a safety (limit) control. Packaged weight 0.66 lb. (300 g), Enclosure, PV plastic Dimensions 4-3/4 H x 2-7/8 W x 7/8 D (120 x 74 x 22 mm) Approvals SA US, SA 22.2 No 24 and UL 873, meets class B: IES & F Part 15 Ambient conditions Indoor use only, -20 to 120 F (-30 to 50 ), < 90% RH non-condensing. Power supply 24 V (ac) ±10%, 50/60 Hz, 3 VA or 24 V (dc) ± 10%, 0.03 A Relays 240 V (ac) 10 A, 1/3 hp sors NT thermistor, 10 kω @ 77 F (25 ±0.2 ) ß=3892 included: Universal sor optional: Universal sor Programmed settings Ten year memory backup ontrol accuracy ±0.5 F (±0.3 ) with up to 500 feet (150 m) of 18 AWG wire to sensors. Temperature display -85 to 302 F (-65 to 150 ) Supply (1) Setpoint -40 to 239 F (-40 to 115 ) Throttling Range 16 to 66 F (9 to 37 ) Boiler Return (2) -40 to 239 F (-40 to 115 ) Temperature display Fahrenheit / elsius Meets lass B: anadian IES F Part 15 Made in anada tektra 906-07 PRGM 1 2 Supply (1) O Throttling Return (2) Item Mixing Setpoint ontrol Floating Action Power 24 V (ac) ± 10% 50/60 Hz 3 VA 24 V (dc) ± 10% 0.03 A Relay 240 V (ac) 10 A 1/3 hp F H1096F 1 3 4 2 5 6 7 8 Signal wiring must be Power R+ Pwr Mix Opn Mix om Sup ls Ret rated at least 300 V Mix Date ode System Operation & Specifications The Mixing Setpoint ontrol controls a 4-way mixing valve in order to maintain a preset mixed supply temperature. With the addition of the optional Universal sor () on the boiler return, the also provides Boiler Return Protection. Piping and Heat Source Details The system is piped in a primary - secondary arrangement using a 4-way mixing valve. The boiler and the boiler loop pump () are controlled by the boiler's control package. The system pump () operates continuously providing flow through the system. Mixing Operation The modulates the mixing valve using a Floating Action Output. The installer / operator is required to set the Supply temperature, Throttling range and Return temperature limits using the digital display in the control. With this information, the control modulates the mixing valve in order to maintain the desired setpoint. Boiler Protection As the boiler return temperature approaches the Return temperature setting, the begins closing the valve in order to limit the amount of cool water returning to the boiler. In this situation, the protection of the boiler takes priority over maintaining the supply temperature. Additional Functions Additional control functions are listed in the table in the Setpoint ontrols section of the Product atalog I 000. ontrol Systems tekmar ontrol Systems Ltd., anada tekmar ontrol Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road Vernon, B.. anada V1B 3K4 Tel. (250) 545-7749 Fax. (250) 545-0650 Product design, software and literature are opyright 2008 by: tekmar ontrol Systems Ltd. and tekmar ontrol Systems, Inc. All specifications are subject to change without notice. Printed in anada. A -2-12/08.

Mixing Setpoint ontrol - Application A -3 12/08 Mechanical 24 V (ac) Supply sor () M 1 V1 Boiler Return sor () Electrical 1 = Actuating Motor = Boiler Pump = System Pump = Supply sor = Boiler Return sor V1 = 4-Way Mixing Valve 10A 10A 1 2 3 4 5 6 7 8 Power Pwr Opn ls om Sup Ret - R+ Mix Mix Mix 1 2 3 om Opn ls 1 L N 24 V (ac) R Note: This is only a concept drawing. The designer must determine whether this application will work in his system and must ensure compliance with code requirements. Necessary auxiliary equipment, isolation relays (for loads greater than the specified tekmar internal relay ratings), and other safety and limit devices must be added.

Technical Data A -3 Mixing Setpoint ontrol Floating Literature A 's, D, D 001, D 070 ontrol Microprocessor control; This is not a safety (limit) control. Packaged weight 0.66 lb. (300 g), Enclosure, PV plastic Dimensions 4-3/4 H x 2-7/8 W x 7/8 D (120 x 74 x 22 mm) Approvals SA US, SA 22.2 No 24 and UL 873, meets class B: IES & F Part 15 Ambient conditions Indoor use only, -20 to 120 F (-30 to 50 ), < 90% RH non-condensing. Power supply 24 V (ac) ±10%, 50/60 Hz, 3 VA or 24 V (dc) ± 10%, 0.03 A Relays 240 V (ac) 10 A, 1/3 hp sors NT thermistor, 10 kω @ 77 F (25 ±0.2 ) ß=3892 included: Universal sor optional: Universal sor Programmed settings Ten year memory backup ontrol accuracy ±0.5 F (±0.3 ) with up to 500 feet (150 m) of 18 AWG wire to sensors. Temperature display -85 to 302 F (-65 to 150 ) Supply (1) Setpoint -40 to 239 F (-40 to 115 ) Throttling Range 16 to 66 F (9 to 37 ) Boiler Return (2) -40 to 239 F (-40 to 115 ) Temperature display Fahrenheit / elsius Meets lass B: anadian IES F Part 15 Made in anada tektra 906-07 PRGM 1 2 Supply (1) O Throttling Return (2) Item Mixing Setpoint ontrol Floating Action Power 24 V (ac) ± 10% 50/60 Hz 3 VA 24 V (dc) ± 10% 0.03 A Relay 240 V (ac) 10 A 1/3 hp F H1096F 1 3 4 2 5 6 7 8 Signal wiring must be Power R+ Pwr Mix Opn Mix om Sup ls Ret rated at least 300 V Mix Date ode System Operation & Specifications The Mixing Setpoint ontrol controls a 4-way mixing valve in order to maintain a preset mixed supply temperature. With the addition of the optional Universal sor () on the boiler return, the also provides Boiler Return Protection. Piping and Heat Source Details The system is piped in a primary - secondary arrangement using a 4-way mixing valve. The boiler and the boiler loop pump () are controlled by the boiler's control package. The system pump () operates continuously providing flow through the system. Mixing Operation The modulates the mixing valve using a Floating Action Output. The installer / operator is required to set the Supply temperature, Throttling range and Return temperature limits using the digital display in the control. With this information, the control modulates the mixing valve in order to maintain the desired setpoint. Boiler Protection As the boiler return temperature approaches the Return temperature setting, the begins closing the valve in order to limit the amount of cool water returning to the boiler. In this situation, the protection of the boiler takes priority over maintaining the supply temperature. Additional Functions Additional control functions are listed in the table in the Setpoint ontrols section of the Product atalog I 000. ontrol Systems tekmar ontrol Systems Ltd., anada tekmar ontrol Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road Vernon, B.. anada V1B 3K4 Tel. (250) 545-7749 Fax. (250) 545-0650 Product design, software and literature are opyright 2008 by: tekmar ontrol Systems Ltd. and tekmar ontrol Systems, Inc. All specifications are subject to change without notice. Printed in anada. A -3-12/08.