RESIDENTIAL & COMMERCIAL HEATING PRODUCTS

Similar documents
GeniSys 24V. Model Advanced 24 Vdc Burner Control. Description / Applications

Gas Conversion Kits and Instructions

MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces

ELECTRONIC FIREPLACE DAMPER

Applies to: Models F, B, FE, and BE with spark pilot

FADE Series Wall Axial Fans

Installation Manual. English. French

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

ROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)

Lyric Homeowner s Operation and Maintenance Manual. ORTAL Heating Systems Ltd.

Models: AFVK-SP-SPLIT AFVK-SP-H/L-SPLIT AFVK-SP-MH/L-SPLIT INSTALLATION AND OPERATING INSTRUCTION

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Air Curtain. Installation, Operating and Maintenance Instructions

HP190SL Series Slimline Radon Fans

OWNER S MANUAL: Model # JGSBSEAR Searing Burner Station

Lint Slide Grid Moist Air Applicator

WX-900 Oil (REV. 08/09)

SOARER TT BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

Installation, Operation and Maintenance Manual

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

StormPro BA Series Sump Pump

SYSTEM CONTROL KIT. Model: CK-41F. Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances.

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS FOR PCBM-36C CONVERSION KIT From Natural Gas to Propane/LP Gas

Terms and Conditions

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

PVI 60KW, PVI 82KW, PVI 95KW

Power. On Your Terms.

State of California AIR RESOURCES BOARD EXECUTIVE ORDER NVR-1-C. Relating to Certification of Non-Vapor Recovery Hoses

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

Kitchen Tech Series Air Curtain

Model 8144NC Fresh Air Ventilator

24Vdc Oil Burner Manual

Safety Pilot System For Vented Gas Logs

ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS

18660, 18661, & Stealth Fuel Cell INSTALLATION INSTRUCTIONS

10 Year Limited Warranty

11202 INSTALLATION INSTRUCTIONS

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

SAVE THESE INSTRUCTIONS DANGER

Natural Gas Conversion Instructions for

AEROMOTIVE Part # L 4V Fuel Rails INSTALLATION INSTRUCTIONS

Installation, Operation and Maintenance Manual

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

CHALLENGER Propane to Natural Gas Instructions

Grinnell Grooved Fire Protection Products Grooved Fittings

Installation Manual DIAPHRAGM WELL TANK

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

Pressurized oil drain for collection of used lubricants and anti-freeze.

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

SUBMERSIBLE SUMP PUMPS

MODELS GAS-FIRED. Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.

Installation Instructions

Full Length Bed Rail - Model G29

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

USER GUIDE 1 USER GUIDE

MIL-24/2600Q MIL-24/3200DQ

Load & Lock Cremators

SUPRA JZA80 TWIN TURBO BLOW-OFF VALVE ADAPTOR INSTRUCTIONS

COLD AIR INTAKE SYSTEM, CIVIC Si,

Tank Monitor. Instruction manual DTM01. Tank Monitor

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

AEROMOTIVE Part # Ford 5.4L Shelby GT500 Mustang INSTALLATION INSTRUCTIONS

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

AUTOMATIC SUBMERSIBLE UTILITY PUMP

HOW TO INSTALL YOUR BOV

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

Use/Installation Guide

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

SUBMERSIBLE SUMP PUMPS

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

SOLAR DASH CHARGING SYSTEM USER GUIDE

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

venting systems for high efficiency appliances series

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Limitation of warranties and other warranty terms and state law rights:

Submersible Waterfall Pump 1200 Gallons Per Hour

GENERAL WARRANTY TERMS & CONDITIONS FOR EICS PERMANENTLY SEALED CATALYSTS HAVING DIAMETERS OF 9.5 in, 11 in, & 13 in.

Installation Instructions

Crestron MMK-G1-CBF-T Mud Ring Mount Kit for Cameo Installation Guide

MINISTICK TM UV Germicidal Ultraviolet Light

OWNERS MANUAL JANUARY 2007 ISO

User Guide IGD Series

SPC-PANEL Simplex, Single Phase Pump Control Panel

c EDR /11. ShipShape OWNERS MANUAL. [ power foundations ]

OWNERS MANUAL JANUARY 2007 ISO

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-122 REV A 12/09

MOM FRIENDLY. DAD READY.

AEROMOTIVE Part # Subaru STI Fuel Rail Kit INSTALLATION INSTRUCTIONS

Transcription:

RESIDENTIAL & COMMERCIAL HEATI PRODUCTS CG4 Gas Guide Form No. 62069-001, Printed in the USA 10/17 www.beckettcorp.com

Before Calling a Manufacturer s Tech Service... Before contacting us about your burner, you must have a completed copy of the Contractor Start-Up Form (located inside last page). This information is crucial for troubleshooting and obtaining the correct replacement parts. Professional Service Failure to follow these recommended settings could lead to equipment malfunction and result in asphyxiation, explosion or fire. y Please read the CG4 manual before proceeding. Follow all instructions completely. y This equipment must be installed, adjusted and started by a qualified service agency that is licensed and experienced with all applicable codes and ordinances and responsible for the installation and commissioning of the equipment. y The installation must comply with all local codes and ordinances having jurisdiction and the latest edition of the National Fuel Gas Code ANSI Z223.1 (NFPA 54) and CAN1-B149.1 in Canada. Applicances have been tested or verified by but NOT tested or endorsed by the appliance manufacturer, unless noted. These settings are not intended to supersede the appliance manufacturer s published specifications. Always follow the appliance manufacturer s published instructions and recommendations. The recommended air settings are intended for use only as a starting point for burner adjustments. The settings cannot make provisions for all installation possibilities. It is important that the burner is adjusted to the installation requirements using properly calibrated flue gas analysis instruments. Always use calibrated test instruments to set combustion levels. Verify that test instruments are calibrated and in good working condition. If not already provided, drill test access holes in the flue pipe near the breach (or upstream of the boiler breach damper, if applicable) and in the front mounting plate area for firebox pressure. Be careful not to damage any water-backed surface. For technical assistance please call 1-800-645-2876 (8:00am - 5:00pm EST, Mon-Fri) 1

ANSI Z21.17a Gas Conversion Standard, requires specific warnings to be placed on the cover of all instruction manuals for gas conversion burners. Below are examples of these types of warnings which must be understood and followed. Fire or Explosion Hazard Can cause severe injury, death or property damage If the information in these instructions is not followed exactly, a fire or explosion may result causing personal injury, death or property damage. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS y Do not try to light any appliance y Do not touch any electrical switch; do not use any phone in your building. y Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. y If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Fire, Explosion or Carbon Monoxide Poisoning Hazard Can cause severe injury, death or property damage This conversion kit must be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authority having jurisdiction (in Canada, in accordance with the requirements of the CAN/CGA-B149 Installation Codes). If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit. 2

CG4 Gas Approvals The CG4 Gas has been evaluated by UL and certified to meet the standards for Domestic Gas Conversion s for the US and for Canada. The applicable standards met are ANSI Z21.17a-1998 and CSA 2.7-M98 (AMERICAN NATIONAL STANDARD/CSA STANDARD FOR DOMESTIC GAS CONVERSION BURNERS) and they address the burner requirements for the conversion of oil-fired appliances to gas. The CG4 carries the culus listing mark and is listed under UL file MH60758 for both Domestic Gas Conversion and Domestic Gas Conversion Certified for Canada. The nature of residential oil appliance fuel conversions makes it impractical to retest and certify the oil appliance for power gas burners. ANSI Z21.17a was developed to provide the requirements for a gas burner that can be used to convert an oil-fired appliance to a gas-fired appliance. ANSI Z21.17a is referenced for oil to gas burner conversions by recognized national codes, such as NFPA 54 and the International Mechanical Code. has designed and tested the CG4 to meet ANSI Z21.17a when the burner is installed to our requirements, which are found in the Installation and Operation (I&O) Manual for our respective burner. The I&O Manual is written to the referenced installation standards of ANSI Z21.8 (AMERICAN NATIONAL STANDARD INSTALLATION OF DOMESTIC GAS CONVERSION BURNERS). Local inspectors shall require the contractor to meet local codes and/or ANSI Z21.8, whichever is most restrictive and any additional manufacturer s requirements as identified in the I&O Manual. These steps will satisfy building and occupant safety with respect to the installation of our conversion burner. Heat exchanger warranties are at the sole discretion of the appliance manufacturer. Most maintain the warranty when converted to gas. has a growing list of appliances which have successfully been evaluated or verified for conversion to a CG4 gas burner in our application lab. The manual clearly states: This equipment must be installed, adjusted and started by a qualified service agency that is licensed and experienced with all applicable codes and ordinances and responsible for the installation and commissioning of the equipment. Use test instruments to set combustion and follow the recommended procedure to attain combustion readings to which the CG4 should be set. Included with each burner is a tag to be completed by the contractor once the installation is finished. It is imperative that the tag be completed in its entirety by the installer, detailing the appliance and burner information, as well as combustion readings and chimney information. This tag should be referred to during all inspections as well as any time the burner is serviced. The application testing process verifies the following burner performance criteria as tested on each approved appliance: Standard firing rate within the appliance manufacturer s input rating Low air setting performance High air setting performance and ignition at high air Performance at recommended air setting Positive chimney draft (+0.1 w.c.) performance at standard air setting Negative chimney draft (-0.1 w.c.) performance at standard air setting Acceptable stack temperature above 325 F at 90% reduced input rate Cold air operation at standard air setting 3

Safety Check-off List Recommendations Follow installation manual instructions. Verify incoming gas pressure. Verify the BTU rating of gas meter. Verify that the pipe size meets the input BTU rating of the appliance Verify combustion air supply meets code requirements (consult local authorities for prevailing codes). Verify that area around appliance is free of lint or pet hair. Verify condition and size of chimney and venting. Venting must comply with code, including construction, size and liner requirements. Verify condition and routing of flue pipe. Total length should be as short as possible (note the quantity of elbows, tees, and location of draft regulators). Verify type of draft regulator. Verify clearances to combustibles, including chimney connector, burner, and appliance. NOTICE: A manometer and combustion analyzer are required tools for proper installation and adjustment. When Converting from Oil to Gas Thoroughly clean heat exchanger of appliance. Replace chamber kit. Install double action draft regulator. Seal up boiler sections, clean out plates and boiler mounting plate. Install thermal safety switch (ex. Field Controls GSK-3 or similar). Adjust burner to operate at no less than 90% of input of the appliance rating plate (GPH x 140,000 x.9 = lowest BTU firing rate). Verify stack temperature is at a minimum of 325 F or appliance manufacturer s recommended setting. Be aware that failure to maintain proper stack temperature could result in condensed flue gas and cause chimney damage which could result in CO leakage into dwelling. How To order a Complete from the chart below : 1). Select the Part. 2). Part. 3). Assemble following the manual supplied with the burner chassis. 4

Tested or Verified List NOTICE s have been tested WARNI Professional Service or verified by but NOT tested or endorsed by Failure to follow these recommended settings could lead to the appliance manufacturer, unless noted. These equipment malfunction and result in asphyxiation, explosion or fire. settings are not intended to supersede the appliance. Please read the CG4 manual and follow all instructions completely. manufacturer's published specifications. Always follow. The installation must comply with all local codes and ordinances the appliance manufacturer's published instructions having jurisdiction and the latest edition of National Fuel Gas Code and recommendations. ANSI Z223.1 (NFPA 54) and CAN1-B149.1 in Canada. NOTICE The recommended air settings are intended for use only as a starting point for burner adjustments. The settings cannot make provisions for all installation possibilities. It is important that the burner is adjusted to the installation requirements using properly calibrated flue gas analysis instruments. Buderus Head Insertion G115-3 96,000 90,000 CG4001 CG4BUF3 F3G 5.25" 0.234 0.177 5880 S-7 / B-0 Blank G115-4 126,000 130,000 CG4001 CG4BUF3 F3G 5.25" 0.364 0.234 NONE S-5 / B-0 4 - Slot G115-5 154,000 145,000 CG4001 CG4BUF4 F4G 5.25" 0.316 0.234 5880 S-10 / B-1 4 - Slot Head Insertion G215-3* 154,000 145,000 CG4001 CG4BUF4 F4G 5.25" 0.316 0.234 NONE S-5 / B-0 4 - Slot G215-4* 196,000 190,000 CG4001 CG4BUF6 F6G 5.25" 0.354 0.256 NONE S-8 / B-0 4 - Slot * Heat Exchanger s Must Be Removed to Achieve Appropriate Flue Temperature Above 325 F. V8 Series Head Insertion V83 105,000 110,000 CG4001 CG4MUF3 F3G 1.75" 0.277 0.206 5880 S-7 / B-0 Blank V83 147,000 145,000 CG4001 CG4MUF4 F4G 1.75" 0.316 0.234 5880 S-10 / B-0 4 - Slot V84 147,000 160,000 CG4001 CG4MUF4 F4G 1.75" 0.348 0.246 5880 S-10 / B-0 4 - Slot V84 189,000 175,000 CG4001 CG4MUF4 F4G 1.75" 0.406 0.261 None S-6 / B-0 4 - Slot V85 189,000 190,000 CG4001 CG4MUF6 F6G 1.75" 0.354 0.256 None S-8 / B-0 4 - Slot V85 231,000 220,000 CG4001 CG4MUF6 F6G 1.75" 0.422 0.281 None S-9 / B-0 4 - Slot MPO Series Head Insertion MPO115 115,000 110,000 CG4001 CG4BMPOF3 F3G 2.00" 0.277 0.266 5880 S-8 / B-0 4 - Slot MPO147* 147,000 145,000 CG4001 CG4BMPOF4 F4G 2.00" 0.316 0.234 5880 S-6 / B-0 4 - Slot MPO189* 189,000 190,000 CG4001 CG4BMPOF4 F4G 2.00" None 0.281 None S-10 / B-1 4 - Slot * Heat Exchanger s Must Be Removed to Achieve Appropriate Flue Temperature Above 325 F. 5

TWZ Series Head Insertion TWZ075 105,000 110,000 CG4001 CG4SFF3 F3G 1.75" 0.277 0.206 5880 S-7 / B-0 Blank TWZ100 140,000 140,000 CG4001 CG4SFF3 F3G 1.75" N/A 0.242 None S-7-1/2 / B-0 4 - Slot TWZ125 175,000 160,000 CG4001 CG4SFF4 F4G 1.75" 0.348 0.246 None S-6-1/2 / B-0 4 - Slot TWZ175 245,000 220,000 CG4001 CG4SFF6 F6G 1.75" 0.422 0.281 None S-9 / B-0 4 - Slot KSZ Series Head Insertion KSZ075 105,000 110,000 CG4001 CG4SFF3 F3G 1.75" 0.277 0.206 5880 S-7 / B-0 Blank KSZ100 140,000 140,000 CG4001 CG4SFF3 F3G 1.75" N/A 0.242 None S-7-1/2 / B-0 4 - Slot KSZ125 175,000 160,000 CG4001 CG4SFF4 F4G 1.75" 0.348 0.246 None S-6-1/2 / B-0 4 - Slot KSZ175 245,000 220,000 CG4001 CG4SFF6 F6G 1.75" 0.422 0.281 None S-9 / B-0 4 - Slot FWZ Series Head Insertion FWZ080 112,000 110,000 CG4001 CG4BMPOF3 F3G 2.00" 0.277 0.266 5880 S-8 / B-0 4 - Slot FWZ100* 147,000 145,000 CG4001 CG4BMPOF4 F4G 2.00" 0.316 0.234 5880 S-6 / B-0 4 - Slot FWZ130* 189,000 190,000 CG4001 CG4BMPOF4 F4G 2.00" None 0.281 None S-10 / B-1 4 - Slot * Heat Exchanger s Must Be Removed to Achieve Appropriate Flue Temperature Above 325 F. Peerless Head Insertion WBV-3-085 119,000 120,000 CG4001 CG4PBF3 F3G 2.50" 0.316 0.219 None S-3.5 / B-0 4 - slot WBV-3-105 147,000 140,000 CG4001 CG4PBF3 F3G 2.50" None 0.242 None S-7 / B-0 4 - slot WBV-4-125 175,000 175,000 CG4001 CG4PBF4 F4G 2.50" 0.406 0.261 None S-8 / B-0 4 - slot WBV-4-150 210,000 190,000 CG4001 CG4PBF4 F4G 2.50" None 0.281 None S-10 / B-0 4 - slot Peerless Head Insertion EC-3 140,000 140,000 CG4001 CG4PBF3 F3G 2.50" None 0.242 None S-7 / B-0 4 - slot EC-4 175,000 190,000 CG4001 CG4PBF4 F4G 2.50" None 0.281 None S-10 / B-2 4 - slot EC-5 245,000 250,000 CG4001 CG4PBF6 F6G 2.50" None 0.312 None S-10 / B-4 4 - slot 6

FR Series Head Insertion FR-98 119,000 120,000 CG4001 CG4MUF3 F3G 1.75" 0.316 0.219 Yes S-8 / B-0 4 - slot FR-122 154,000 140,000 CG4001 CG4MUF3 F3G 1.75" None 0.242 No S-7 / B-0 4 - slot HGSI 140,000 140,000 CG4001 CG4MUF3 F3G 1.75" None 0.242 No S-7 / B-0 4 - slot CL Series Head Insertion CL3-105 105,000 110,000 CG4001 CG4MUF3 F3G 1.75" 0.277 0.206 5880 S-7 / B-0 Blank CL4-175 175,000 160,000 CG4001 CG4MUF4 F4G 1.75" 0.348 0.246 None S-6-1/2 / B-0 4 - Slot CL5-245 245,000 220,000 CG4001 CG4MUF6 F6G 1.75" 0.422 0.281 None S-9 / B-0 4 - Slot CL-HGS Series Head Insertion CL-HGS 114,000 110,000 CG4001 CG4BMPOF3 F3G 2.00" 0.277 0.266 5880 S-8 / B-0 4 - Slot CL-HGS* 147,000 145,000 CG4001 CG4BMPOF4 F4G 2.00" 0.316 0.234 5880 S-6 / B-0 4 - Slot CL-HGS* 189,000 190,000 CG4001 CG4BMPOF4 F4G 2.00" None 0.281 None S-10 / B-1 4 - Slot * Heat Exchanger s Must Be Removed to Achieve Appropriate Flue Temperature Above 325 F. Slant/Fin Intrepid Head Insertion TR-30 140,000 140,000 CG4001 CG4SFF3 F3G 1.75" None 0.242 None S-8 / B-0 4 - slot TR-40 210,000 190,000 CG4001 CG4SFF4 F4G 1.75" None 0.281 None S-10 / B-3 4 - slot Thermo Dynamics Head Insertion CWL 119,000 130,000 CG4001 CG4TDF4 F4G 3.50" 0.231 0.217 5880 S-10 / B-1 4 - slot CWL 140,000 145,000 CG4001 CG4TDF4 F4G 3.50" 0.316 0.234 5880 S-10 / B-3 4 - slot Utica Starfire Head Insertion SFH-3085W 119,000 120,000 CG4001 CG4UTF3 F3G 2.25" 0.316 0.219 Yes S-10 / B-1 4 - slot SFH-3100W 140,000 140,000 CG4001 CG4UTF3 F3G 2.25" None 0.242 No S-10 / B-0 4 - slot SFH-4100W 140,000 145,000 CG4001 CG4UTF4 F4G 2.25" 0.316 0.234 Yes S-10 / B-3 4 - slot 7

Weil-McLain Gold Head Insertion GO2* 105,000 100,000 CG4001 CG4WMF3 F3G 3.00" 0.250 0.189 5880 S-4.5 / B-0 Blank GO3R 112,000 120,000 CG4001 CG4WMF3 F3G 3.00" 0.316 0.219 5880 S-9 / B-0 4 - slot GO3 133,000 130,000 CG4001 CG4WMF3 F3G 3.00" 0.364 0.234 None S-6 / B-0 4 - slot GO4R 140,000 145,000 CG4001 CG4WMF4 F4G 3.00" 0.316 0.234 5880 S-10 / B-1 4 - slot GO4 168,000 160,000 CG4001 CG4WMF4 F4G 3.00" 0.348 0.246 None S-6.5 / B-0 4 - slot GO5R 168,000 175,000 CG4001 CG4WMF4 F4G 3.00" 0.406 0.261 None S-7.5 / B-0 4 - slot GO5 203,000 190,000 CG4001 CG4WMF4 F4G 3.00" None 0.281 None S-10 / B-0 4 - slot * Must Use 7.00" Flue Only. Weil-McLain Ultra Head Insertion UO3* 140,000 140,000 CG4001 CG4MUF3 F3G 1.75" None 0.242 None S-8 / B-0 4 - slot UO4* 160,000 160,000 CG4001 CG4MUF4 F4G 1.75" 0.348 0.246 None S-7 / B-0 4 - slot UO5* 196,000 190,000 CG4001 CG4MUF4 F4G 1.75" None 0.281 None S-10 / B-2 4 - slot * Heat Exchanger s Must Be Removed to Achieve Appropriate Flue Temperature Above 325 F. Williamson Head Insertion OWB/OWT-3 98,000 100,000 CG4001 CG4WMF3 F3G 3.00" 0.250 0.189 5880 S-4.5 / B-0 Blank OWB/OWT-3 133,000 130,000 CG4001 CG4WMF3 F3G 3.00" 0.364 0.234 None S-6 / B-0 4 - slot OWB/OWT-4 140,000 145,000 CG4001 CG4WMF4 F4G 3.00" 0.316 0.234 5880 S-10 / B-1 4 - slot OWB/OWT-4 168,000 160,000 CG4001 CG4WMF4 F4G 3.00" 0.348 0.246 None S-6.5 / B-0 4 - slot OWB/OWT-5 168,000 175,000 CG4002 CG4WMF4 F4G 3.00" 0.406 0.261 None S-7.5 / B-0 4 - slot OWB/OWT-5 203,000 190,000 CG4001 CG4WMF4 F4G 3.00" None 0.281 None S-10 / B-0 4 - slot Notes: Blank Air Band included in CG4XXF3 ATC combinations See Manual for operating pressure requirements 8

Contractor Start-Up Form Installation Name: Installation Date: Installation Address: Start-Up Contractor s Name Phone: Name of Technician (Information below can be obtained from appliance name plate) Manufacturer: Type (circle one): [ Boiler / Furnace / Other ] Model #: Serial #: Input MBH: Original Designed for (circle one): [ Oil / Natural Gas / Propane ] Output MBH: Limits Limit Model No. (Indicate n/a if not required by the appliance manuf.) Operation Verified Temperature YES / NO Pressure YES / NO LWCO YES / NO Other Limits YES / NO / n/a Fuel: [ Natural Gas / Propane ] Model #: Serial #: Combustion Head: [ F3G / F4G / F6G ] Fuel : Air Shutter Setting: Air Band Setting: [ or Blank Band Installed ] : [ Installed / Not ] Chimney/Smoke Pipe Chimney Type:[ Masonry / Metal Vent / Direct Vent ] Location (circle one): [ Inside / Outside ] Chimney Height: Flue Pipe : Flue Pipe Length: of Elbows: Confirm Double Acting Draft Regulator Installed: [ Yes / No ] Thermal Safety Switch Installed [ Yes / No ] Voltage: [ 120V / 24V ] Gas Supply Piping Pipe Diameter: Length of Pipe from to Meter: of Elbows: Gas Pressure to Gas Valve While is Operating Inches W.C. Combustion Readings O 2 : % CO: PPM CO 2 : % Stack Temperature (325 F MIN.): F Manifold Gas Pressure: (Inches W.C.) Draft at Breach W.C. 9

Notes 10

Limited Warranty Information The R. W. BECKETT CORPORATION ( ) warrants to persons who purchase its Products from for resale, or for incorporation into a product for resale ( Customers ), that its equipment is free from defects in material and workmanship. To qualify for warranty benefits, products must be installed by a qualified service agency in full compliance with all codes and authorities having jurisdiction, and used within the tolerances of s defined product specifications. To review the complete warranty policy and duration of coverage for a specific product, or to obtain a written copy of warranty form 61545, please choose one of the following options: 1. Visit our website at: www.beckettcorp.com/warranty 2. Email your request to: rwb-customer-service@beckettcorp.com 3. Write to: R. W. Corporation, P. O. Box 1289, Elyria, OH 44036 NOTE: is not responsible for any labor cost for removal and replacement of equipment. THIS WARRANTY IS LIMITED TO THE PRECISE TERMS SET FORTH ABOVE, AND PROVIDES EXCLUSIVE REMEDIES EXPRESSLY IN LIEU OF ALL OTHER REMEDIES, AND IN PARTICULAR THERE SHALL BE EXCLUDED THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL BECKETT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGE OF ANY NATURE. neither assumes, nor authorizes any person to assume for, any other liability or obligation in connection with the sale of this equipment. s liability and Customer s exclusive remedy is limited to the cost of the product. USA: P.O. Box 1289 Elyria, Ohio 44036 Canada: R.W. Canada, Ltd. Unit #3, 430 Laird Road Guelph, Ontario N1G 3X7 www.beckettcorp.com 1-800-OILBURN (645-2876)