Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Similar documents
Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

ZX-Family Gas-insulated medium voltage switchgear

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

ZX2 Gas-insulated medium voltage switchgear

Surge arrester POLIM-H..SD

Surge arrester POLIM-H.. ND

EMPAC Metal enclosed capacitor bank for wind applications

TECHNICAL SPECIFICATIONS

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Selective main circuit breakers S 750 series Technical Data

Elimsan High Voltage Disconnectors

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

LV Capacitors QCap-L series Capacitors for power factor correction

ZX2.2 Gas-insulated medium voltage switchgear

Mini contactors B6, BC6 with 3 pole

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Low Voltage Systems MNS and MNS is PowerCenter

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Surge arrester POLIM-C.. HD

Section 2 - Substation Switchgear

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

TriLine PowerModules Overview with Planing Examples

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

Overview Overvoltage protection

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

ABB Low voltage systems MNS Platform

NRB Disconnector for outdoor installation

Surge arrester POLIM-H..N

Indoor disconnectors ITr. single- and three-pole design rated voltage 12, 25 and 38.5 kv rated current A

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

B kv Gas-insulated Substations

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

ZX-Family Gas-insulated medium voltage switchgear

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Thermal Overload Relays

Disconnectors and earthing switches up to 25 kv AC

Manual motor starters Overview and benefits

NXPLUS C Single busbar. Maintenance-free for lifetime

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

Voltage limiting device HVL

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Voltage limiting device HVL

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

ABB Seccionadores de Potencia HV Caracteristicas Tecnicas y Aplicaciones Especiales.

Manual motor starter magnetic only MO325

Brochure. Synchronous generators for diesel and gas engines Proven generators reliable power

Thermal overload relay TF65 and TF96

Electronic overload relay EF65, EF96 and EF146

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Electronic overload relays EF205 and EF370

Benefits, typical uses

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

PRODUCT BROCHURE. ABB Ability Wireless Monitor for surge arrester Enabling reliability and availability of power supply

US Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

8DJ. Maintenance-free for lifetime

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Air-insulated switchgear UniGear type ZS1

Independent Testing Laboratory for High Voltage Equipment

Thermal overload relay TF140DU and TF140DU-V1000

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

B kv T&D GAS INSULATED SWITCHGEAR

Gas Insulated Metal-clad Switchgear, HMGS!

the safe, reliable, and efficient choice for MV switchgear

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

TwinLine The new system of wall-mounting and floor-standing cabinets

Transcription:

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

2 Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance ABB is a leader in power and automation technologies that enables utility and industry customers to improve their performance while lowering environmental impact. The ABB Group of companies operates in approximately 100 countries and employs around 145,000 people. Disconnectors from ABB ABB disconnectors have been in service across the world for over two decades providing maintenancefree service with the highest records of operation reliability. The worldwide experience, often under severe climatic conditions, is applied for continual product improvement. Applications A mechanical device for providing isolation of power equipment from the network, a disconnector is suitable for switching very small currents or where no significant change in voltage occurs across the terminals. The option of earthing sections of power systems can be made available by providing each disconnector pole with one or two earthing switches. The semi-pantograph disconnectors type DSSP are available for rated voltages up to 300 kv. Standards The DSSP disconnectors are designed as per IEC 62271-102 and IEC 62271-1 standards. Other international regulations can be met on request. Type tests on the disconnectors are carried out by accredited testing laboratories in accordance with the latest regulations. Comprehensive electrical and mechanical routine tests are carried out on the poles and operating mechanism of each disconnector ensuring world class quality.

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance 3 Contents 4-5 6 7 8 9 Maximum reliability and minimal maintenance Technical data Main dimensions Mode of operation Earthing switches

4 Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Maximum reliability and minimal maintenance Designed based on cutting-edge technology and experience The semi-pantograph disconnector consists of three poles. Each pole consists of the hot-dip galvanized steel structure base, one support insulator, one rotating insulator, the live base, one current path including two articulated arms, the pantograph mechanism, and the contact system. The disconnnectors can be equipped with insulators in accordance with IEC, ANSI or DIN specification and with one earthing switch. Excellent current carrying capability Each pole is equipped with a double U-shape aluminium arms. The open structure,having good heat ventilation, is designed to provide the high continuous current carrying capability and ensures reliable performance under operation. Minimized contact resistance Contacts are made of copper with silver plated surface to prevent oxidation. Multiple point contact provides reliable electrical connection with lower resistance which ensures minimum energy loss. Reliable operation The specific contact force is provided by the contact system and remains unchanged during the entire lifetime. Large contact zone ensures the moving contact catching the fixed contact with the displacement of busbar by various service conditions. Smooth operation Most of the linkage of rods and cranks is selflubricating which makes the disconnectors close and open process smoothly. Optimized semi-pantograph mechanism The rotation of insulator is transferred to pantograph movement by mechanism between upper arm and lower arm. The rod-end ball bearings are used for driving movement smoothly and safely. Easy Installation The modular design concept is applied to the whole switch construction as complete as possible for easy alignment and adjustment. Minimal maintenance Graphite material is used for the disconnector arcing contacts, which have long service life and provide no contamination. In addition, all the steel components are hot-dip galvanized to protect against atmospheric influences. These features make the disconnector require minimum maintenance. Interlocking for reliability under extreme conditions In both end positions of the disconnector, the rotary arm is switched beyond the dead center point. The switch position cannot be changed by external forces even under extreme condition such as storms, earthquake etc. Superior design of mechanical interlock The superior design of mechanical interlock between the earthing switch and disconnector is employed so that there is no scope for malfunction. Ice breaking capacity The disconnectors are capable of operating under sever ice conditions. Suitable for wide range of environmental conditions The disconnectors can operate in a wide range of temperatures as well as under polluted environmental condition. All steel components are hot-dip galvanized which enables the protection against atmospheric influences.

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance 5 01 02 03 04 05 06 01 Frame 02 Live base mechanism The dead center position component integrated in the live base, which ensure disconnector keeping at open position when maintenance & repair performed. This functionality refer to safety. 03 Upper arm with moving contact 04 Lower arm with balance spring Upper arm an d lower arm employ the open structure having good ventilation,which avoid the over-heat happened for long term operation perspective. 05 Fixed contact Fix contact of copper with silver plated which minimize resistance result in minimum energy loss and reliable operation as well. 06 Rack and pinion mechanism The rack and pinion are in housing and used for driving pantograph movement. The housing design avoid corro-sion for long term operation and also refer to reliability.

6 Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Technical data Technical data - DSSP Rated voltage (Ur) kv 123 145 170 245 300 Rated frequency (fr) Hz 50/60 50/60 50/60 50/60 50/60 A 3150 3150 3150 4000 4000 ka/s 40/3 40/3 40/3 50/3 50/3 kap 100 100 104 125 125 To earth and between poles kv 230 275 325 460 460 Across the isolating distance kv 265 315 375 530 606 To earth and between poles kvp 550 650 750 1050 1050 Across the isolating distance kvp 630 750 860 1200 1250 To earth and between poles kv 850 Across the isolating distance kv 700+245 Rated normal current (Ir) Rated short-withstand current, rated duration of short circuit (Ik, tk) Rated peak withstand current (Ip) Rated power frequency withstand voltage for 1 minute Rated lightning impulse withstand voltage (1.2/50 μs) Rated switching impulse withstand voltage 3 pole operated Semi-pantograph disconnector at 300 kv

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance 7 Main dimensions R C A B D Semi-pantograph Disconnector DSSP Rated voltage (kv) Outline dimensions (mm) A B C D R 123 1220 3720 3920 1180 1850 145 1500 4000 4200 1180 1850 170 1700 4200 4400 1180 1850 245 2300 5610 5810 1600 2550 300 2900 6210 6410 1600 2550

8 Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance Mode of operation The disconnectors and earthing switches are operated via independent operating mechanisms. The three phases of the disconnector are connected by the coupling rods. ABB disconnectors and earthing switches are designed and tested in accordance with the latest IEC specifications. All modules are pre-assembled and adjusted in factory as complete as possible, so it can be installed and adjusted at site easily. ABB provide clearly installation instructions and assembly drawings. The disconnectors and earthing switches supplied by ABB are designed so as to ensure that they are virtually maintenance free. However, to warrant a long and trouble- free service period, we advise that a visual inspection of the contacts and bearing points be carried out at regular intervals. If the equipment cannot be inspected periodically, it is recommended to open and close the switches whenever it is possible to do so, in order to clean the contacts and free the moving parts. Operating mechanism The disconnectors and/or earthing switches can be single- pole or three-pole operated by means of a motor-operated drive mechanism or a manual-operated drive mechanism. Customers can choose motor drive or manual drive according to the actual working situation of disconnector. Operating mechanisms contain auxiliary switches for control and signaling as well as provisions for electrical interlocks. ABB disconnector operating mechanism has excellent water proof sand prevention and rust protection performance. The output shaft of the operating mechanism has good sealing ability with the house of operating mechanism. Interlocks The disconnectors and earthing switches (when supplied) are mechanically interlocked. In operating mechanisms a blocking magnet can be installed as an additional interlocking facility, which in disconnected condition makes operation of the operating mechanism impossible. Motor mechanism Manual mechanism

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance 9 Earthing switches The earthing switch unit, an optional assembly, can be mounted on the base as required. Single-Motion Rated voltage / kv Rated current / A Short circuit ratings 72.5~300 630 40~50 ka/3 s, 100~125 ka peak The use of earthing switches ensure absolute safety by grounding and discharging all highvoltage components in a circuit or switchgear. ABB free-standing earthing switches are available for all voltage levels up to 550 kv. Suitable built-on earthing switches are available for all types of ABB disconnectors. According to the requirements, built-on earthing switches can be arranged laterally or in inboard arrangement with respect to the position of the main current path of the disconnector as needed. Optionally, all earthing switches can be designed for switching induced inductive and capacitive currents according to IEC 62271-102, Class A or Class B.

ABB High Voltage Switchgear Co., Ltd., Beijing Add.: No.12 Jingyuan Street, Beijing Economic-Technological Development Area Beijing, 100176, P.R.China Tel: +86 10 6781 8000 Fax: +86 10 6781 8001 ABB Jiangsu Jingke Instrument Transformer Co., Ltd. Add.:No.9 Gucheng Road Su-Su Industriial Park, Suqian,Jiangsu, 223800 P.R China Tel: +86 527 8288 0810 Fax: +86 527 8288 0868 www.abb.com.cn Copyright 2018 ABB. All rights reserved. Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its content - in whole or in parts - is forbidden without ABB's prior written consent. 1YVA000109 -Rev.B, en 2018-05 C Copyright 2018 ABB. All rights reserved.