DIESEL GENERATOR SET MTU 12V4000 DS2250

Similar documents
DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 12V4000 DS1750

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 20V4000 DS3600

DIESEL GENERATOR SET MTU 20V4000 DS3300

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET DS03200D5S

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET DS01650D5S

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 12V1600 DS660

KVA KW KVA KW

DIESEL GENERATOR SET MTU 10V1600 DS500

DIESEL GENERATOR SET MTU 4R0113 DS80

POWER MODULE MTU 16V4000 DS2560

DIESEL GENERATOR SET DG00660D5

KVA KW KVA KW

KVA KW KVA KW

20' STANDARD CONTAINER MTU 16V2000 DS: kva MTU 18V2000 DS: kva

PRODUCT PRESENTATION SERIES kva. MTU Onsite Energy Systems GmbH All rights reserved

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Diesel generator set QSK23 series engine

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

STANDBY 200 ekw 250 kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Model NA 2 L

Standby Rating 220/ / / / / /

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

STANDBY 200 ekw 250 kva

Diesel generator set QSK23 series engine

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

DIESEL GENERATOR DATA SHEET

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

60 Hz FEATURES. Exclusively from your Caterpillar dealer

130 KW / 165 KVA POWERED by

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Standby kw Prime kw

WPS100/S EP Series. Features:

Generator Set Specifications 100 ekw (125 kva)

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

TPD2250H6.3 TECHNICAL DATA

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

WPS350/S EP Series. Features:

Rating Definitions and Conditions

Specifications. 3406C Generator Set Electric Power

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

WPS60/S EP Series. Features:

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Rating Definitions and Conditions

220 to volts. Electronic unit injection

Model MP150 W W

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

640 KW / 800 KVA POWERED by

Diesel generator set QSX15 series engine

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Part III : Technical Specification POS C)

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Transcription:

DIESEL GENERATOR SET MTU 12V4000 DS2250 380V 11 kv/50 Hz/Prime Power for Stationary Emergency/ Fuel Consumption Optimized/MTU 12V4000G34F/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits - Low fuel consumption - Optimized system integration ability - High reliability - High availability of power - Long maintenance intervals // MTU Onsite Energy is a single-source supplier // Support - Global product support offered // Standards - Engine-generator set is designed and manufactured in facilities certified to standards ISO 2008:9001 and ISO 2004:14001 - Generator set complies to ISO 8528 - Generator meets NEMA MG1, BS5000, ISO, DIN EN and IEC standards - NFPA 110 // Power Rating - System ratings: 2100 kva - Accepts rated load in one step per NFPA 110 - Generator set complies to G3 according to ISO 8528-5 - Generator set exceeds load steps according to ISO 8528-5 // Performance Assurance Certification (PAC) - Engine-generator set tested to ISO 8528-5 for transient response - 85% load factor - Verified product design, quality and performance integrity - All engine systems are prototype and factory tested // Complete range of accessories available - Control panel - Power panel - Circuit breaker/power distribution - Fuel system - Fuel connections with shut-off valve mounted to base frame - Starting/charging system - Exhaust system - Mechanical and electrical driven radiators - Medium and oversized voltage alternators // Emissions - Fuel consumption optimized // Certifications - CE certification option

2 / / / MTU 12V4000 DS2250 / 50 Hz / 380V - 11kV APPLICATION DATA ➀ // Engine Manufacturer MTU Model 12V4000G34F Type 4-cycle Arrangement 12V Displacement: l 57.2 Bore: mm 170 Stroke: mm 210 Compression ratio 16.4 Rated speed: rpm 1500 Engine governor ADEC (ECU 9) Max power: kwm 1755 Air cleaner Dry // Fuel System Maximum fuel lift: m 5 Total fuel flow: l/min 27 l/hr g/kwh At 100% of power rating: 413 195 At 75% of power rating: 307 193 At 50% of power rating: 211 199 // Liquid Capacity (Lubrication) Total oil system capacity: l 260 Engine jacket water capacity: l 160 Intercooler coolant capacity: l 40 // Combustion Air Requirements Combustion air volume: m 3 /s 2.2 Max. air intake restriction: mbar 50 // Cooling/Radiator System Coolant flow rate (HT circuit): m 3 /h 55 Coolant flow rate (LT circuit): m 3 /h 30 Heat rejection to coolant: kw 690 Heat radiated to charge air cooling: kw 425 Heat radiated to ambient: kw 75 Fan power for electr. radiator (40 C): kw 55 // Exhaust System Exhaust gas temp. (after engine): C 440 Exhaust gas temp., max (after engine): C 550 Exhaust gas temp. (before turbocharger): C 645 Exhaust gas volume: m 3 /s 5.5 Maximum allowable back pressure: mbar 50 ➀ All data refers only to the engine and is based on ISO standard conditions (25 C and 100m above sea level). ➁ Values referenced are in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml. All fuel consumption values refer to rated engine power.

3 / / / MTU 12V4000 DS2250 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES // System Ratings (kw/kva) Generator model Voltage Fuel consumption optimized without radiator with mechanical radiator kwel kva* AMPS kwel kva* AMPS Leroy Somer LSA52.3 S7 380 V 1680 2100 3191 1624 2030 3084 (Low voltage 400 V 1680 2100 3031 1624 2030 2930 Leroy Somer standard) 415 V 1680 2100 2922 1624 2030 2824 Leroy Somer LSA52.3 L12 380 V 1680 2100 3191 1624 2030 3084 (Low voltage 400 V 1680 2100 3031 1624 2030 2930 Leroy Somer oversized) 415 V 1680 2100 2922 1624 2030 2824 Marathon 744RSL7092 380 V 1672 2090 3175 1616 2020 3069 (Low voltage Marathon) 400 V 1672 2090 3017 1616 2020 2916 415 V 1672 2090 2908 1616 2020 2810 Leroy Somer LSA53.2 XL9 11 kv 1680 2100 110 1632 2040 107 (Medium voltage Leroy Somer) Marathon 1020FDH7097 11 kv 1664 2080 109 1616 2020 106 (Medium volt. marathon) * cos phi = 0,8 // Engine 4-Cycle Standard single stage air filter Oil drain extension & shut-off valve Closed crankcase ventilation Governor-electronic isochronous Common rail fuel injection Fuel consumption optimized engine // Generator 4 pole three-phase synchronous generator Brushless, self-excited, self-regulating, self-ventilated Digital voltage regulator Anti condensation heater Stator winding Y-connected, accessible neutral (brought out) Protection IP23 Insulation class H, utilization acc. to H Radio suppression EN55011, group 1, cl. B Short circuit capability 3xIn for 10sec Winding and bearing RTDs (without monitoring) Excitation by AREP + PMI Mounting of CT s: 3x 2 core CT s Winding pitch: 2/3 winding Voltage setpoint adjustment ± 5% Meets NEMA MG-1, BS 5000, IEC 60034-1, VDE 0530, DIN EN 12601, AS1359 and ISO 8528 requirements Leroy Somer low voltage generator Marathon low voltage generator Oversized generator Medium voltage generator Represents standard features Represents optional features

4 / / / MTU 12V4000 DS2250 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Cooling System Jacket water pump Thermostat(s) Water charge air cooling Mechanical radiator Electrical driven front-end cooler Jacket water heater Pulley for Fan drive // Control Panel Pre-wired control cabinet for easy application of customized controller (V1+) Island operation (V2) Automatic mains failure operation with ATS (V3a) Automatic mains failure operation incl. control of generator and mains breaker (V3b) Island parallel operation of multiple gensets (V4) Automatic mains failure operation with short (< 10s) mains parallel overlap synchronization (V5) Mains parallel operation of a single genset (V6) Mains parallel operation of multiple gensets (V7) Basler controller Deif controller Complete system metering Digital metering Engine parameters Generator protection functions Engine protection SAE J1939 engine ECU communications Parametrization software Multilingual capability Multiple programmable contact inputs Multiple contact outputs Event recording IP 54 front panel rating with integrated gasket Different expansion modules Remote annunciator Daytank control Generator winding temperature monitoring Generator bearing temperature monitoring Modbus TCP-IP // Power Panel Available in 600x600 and 600x1000 Phase monitoring relay 230V/400V Supply for battery charger Supply for jacket water heater Supply for anti condensation heating Plug socket cabinet for 230V compatible Euro/USA Supply electrical driven radiator from 55kW (PP 600x1000) // Circuit Breaker/Power Distribution 3-pole circuit breaker 4-pole circuit breaker Manual-actuated circuit breaker Electrical-actuated circuit breaker Stand-alone solution in seperate cabinet Represents standard features Represents optional features

5 / / / MTU 12V4000 DS2250 / 50 Hz / 380V - 11kV STANDARD AND OPTIONAL FEATURES, CONTINUATION // Fuel System Flexible fuel connectors mounted to base frame Fuel filter with water separator Fuel filter with water separator heavy-duty Switchable fuel filter with water separator Switchable fuel filter with water separator heavy-duty Seperate fuel cooler Fuel cooler integrated into cooling equipment // Starting/Charging System 24V starter Starter batteries, cables, rack, disconnect switch Battery charger Redundant Starter 2x15KW // Mounting System Welded base frame Resilient engine and generator mounting Modular base frame design // Exhaust System Exhaust bellows with connection flange Exhaust silencer with 10 db(a) sound attenuation Exhaust silencer with 30 db(a) sound attenuation Exhaust silencer with 40 db(a) sound attenuation Y-connection-pipe Represents standard features Represents optional features

6 / / / MTU 12V4000 DS2250 / 50 Hz / 380V - 11kV WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings. System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 4077 x 1810 x 2330 mm 11130 kg Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific engine-generator set. SOUND DATA // Consult your local MTU Onsite Energy distributor for sound data. EMISSIONS DATA // Consult your local MTU Onsite Energy distributor for emissions data. RATING DEFINITIONS AND CONDITIONS // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. A 10% overload capability is available for 1 min of duration per event. Ratings are in accordance with ISO 8528-1, ISO-3046-1, BS 5514 and AS 2789. Average Load Factor: 85%. Operating hours/year: max. 500. // Consult your local MTU Onsite Energy Power Generation Distributor for derating information. Subject to change. 32311461 Edition 01/18 ESM 2018-11. Materials and specifications subject to change without notice. MTU Onsite Energy Part of the Rolls-Royce Group www.mtuonsiteenergy.com