PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

Similar documents
Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

TC-RHH/RHW-2 USE-2 Copper

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

MC, THHN/THWN-2 Copper


TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

MC or MV-105 Copper, TR-XLPE Insulated

Mecklenburg County Common Code Defects

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

STABILOY BRAND FeeDeR SOLuTIONS

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Primary, Secondary, Post-Secondary Education Facilities

ATHLETIC STADIUMS AND SPORTS ARENAS

HOSPITAL AND HEALTHCARE

Medium Voltage Power Cables

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

PART A General Conductor Requirements

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

NEC 2014 Code Changes

RENEWABLE ENERGY. Alcan cable solutions

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

Section 8. Portable Cordage & Power Cable

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

UNSHIELDED MULTI CONDUCTOR

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

TUNNELING POWER CABLES

High Voltage Copper, Smooth Aluminum Shield/Sheath

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

DLO. Mining Cable. Mining Cable. 2 kv

Section 11 Mining Cable

E R C. R E R C ; ; W T E C

The Reliable Choice. Field Pocket Guide

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

KALAS ENTERTAINMENT CABLE

Easier! Faster! Safer!

IEEE 1580 TYPE T/N CABLE

Variable Frequency Drive (VFD) Cable Solutions

Omni Cable is a master distributor of specialty wire and cable selling

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Type P Drilmar 125-XE Signal & Instrumentation

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

Type P Drilmar 125-XE Signal & Instrumentation

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

Medium Voltage Cable. marmonutility.com

New TITANEX PREMIUM. No limit!

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

Spring Test 10 due 05/11/2013

C-L-X Aluminum Sheath Type IEC

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Generator Fire Safety: Generator assemblies should be located outside the building.

CHAPTER V RESIDENTIAL WIRING

NEC 2011 Code Changes

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

Automotive Cables. The Global Cable Solutions Company

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

2016 Photovoltaic Solar System Plan Review List

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

Wired for Power Generation

Type MMV-WP Medium Voltage Wind Power Cable

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

Have You Been Grounded Lately

N2XY IEC XLPE PVC 0.6/1kV Cable

BRONCO PHILATRON. Brand. Premium Flexible Power Cable WIRE AND CABLE * USA MANUFACTURER

Spring Test 7 due 05/03/2013

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

See Part 3 for the Introduction for Article 314

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Airfield Ground Lighting

Rail & Transit WIRE AND CABLE

HIGH PERFORMANCE OVERHEAD LINE CONDUCTORS TO UPGRADE YOUR SYSTEM

Your Partner in Safe Power Solutions. About RESCAB

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C

MEDIUM VOLTAGE

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

AMENDMENT ELECTRIC SERVICE MANUAL 2014

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Category # 1 - Overhead, Primary, & Secondary Conductors

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

Transcription:

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

Table of content About Nexans 3 Commercial Building Wire & Cable 4 Armored 5 ENERGEX AC-HCF - Green Striped Armor 6 ENERGEX AC 9 ENERGEX MC 120 Aluminum Armored PVC Jacketed 12 ENERGEX MC 120 Aluminum Armored Unjacketed 16 ENERGEX MC 120 Steel Armored 20 ENERGEX MC 277 Aluminum Armored 24 ENERGEX MC Aluminum Feeder Cable 28 ENERGEX MC Ground Plus 33 ENERGEX MC Mega Neutral 37 ENERGEX MC Multi Conductor 42 Direct Buried 47 ENERGEX 8000 RHH/RHW-2/USE-2 Aluminum 48 ENERGEX RHH/RHW-2/USE-2 Copper 52 Conduit Wire & Cable 56 ENERGEX 8000 Aluminum XHHW-2 57 ENERGEX INSTAGLIDE THHN / THWN-2 / MTW 61 ENERGEX INSTAGLIDE XHHW-2 Copper 65 Components, Specialty & Bare Copper 69 ENERGEX PV/RHH/RHW-2/USE-2 70 Soft Bare Copper USA* 85 Generated 8/2/18 www.nexans.us Page 2 / 87

About Nexans Nexans brings energy to life through an extensive range of cables and cabling solutions that deliver increased performance for our customers worldwide. Nexans teams are committed to a partnership approach that supports customers in four main business areas: Power transmission and distribution (submarine and land), Energy resources (Oil & Gas, Mining and Renewables), Transportation (Road, Rail, Air, Sea) and Building (Commercial, Residential and Data Centers). Nexans strategy is founded on continuous innovation in products, solutions and services, employee development, customer training and the introduction of safe, low-environmental-impact industrial processes. In 2013, Nexans became the first cable player to create a Foundation to introduce sustained initiatives for access to energy for disadvantaged communities worldwide. We have an industrial presence in 40 countries and commercial activities worldwide, employing close to 26,000 people and generating sales in 2015 of 6.2 billion euros. Nexans is listed on Euronext Paris, compartment A. Generated 8/2/18 www.nexans.us Page 3 / 87

Commercial Building Wire & Cable Nexans wide assortment of safe, reliable and environmentally friendly commercial building cables assure ease of installation and provide for the safety and efficiency of low and high-rise offices, retail establishments and public buildings such as schools, hospitals and libraries. Choose the cable type required: Generated 8/2/18 www.nexans.us Page 4 / 87

Armored Cables with interlocked metal tape armor or continuous metal sheath are suitable for applications where cable might be exposed to mechanical damage.the Nexans array of armored cables encompasses superior designs with rugged jackets for direct buried applications while our jacketed and unjacketed cables are manufactured for extreme conditions to withstand the dangers of physical and environmental damage that could be a factor when employed in exposed runs. Generated 8/2/18 www.nexans.us Page 5 / 87

ENERGEX AC HCF Green Striped Armor Green Striped Aluminum Armored AC Cable for Health Care Facility, UL Type AC THH, 600 V, 90 C dry rated - Copper Conductors - RoHS compliant STANDARDS National UL 4; UL 83 DESCRIPTION ENERGEX AC-HCF cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They may be used in patient areas of hospitals, out-patient centers and medical and dental offices. They are not permitted where hazardous anesthetizing is performed. They may also be used in applications which require AC cable with a redundant ground in accordance with NEC Article 250.118(8). They are suitable for installations in accordance with NEC Article 320. These cables may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. Nexans AC HCF cable is RoHS compliant. Construction Conductor: Solid conductors are soft bare annealed copper to ASTM B3. Stranded conductors are soft bare annealed copper to ASTM B3 and ASTM B8. Insulation: PVC/Nylon type THHN in accordance to UL 83, flame resistant, meeting UL VW-1 flame test. Bond Wire: Longitudinal aluminum bond wire in continuous contact with armor. Ground Wire: Green PVC/Nylon Type THHN insulation, sized in accordance with NEC and UL. Assembly: Conductors are individually paper wrapped and cabled with a marker tape/core protection tape combination which assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Armor has an intermittent green stripe to identify HCF cable. Marker Tape Print: ALUMINUM ARMORED CABLE NOT FOR USE ON DC CIRCUITS / CAUTION NOT TO BE USED WITH SET SCREW CONNECTOR / FOR CT USE LEAD FREE (MFG DATE) Specifications Meets UL 4: Armored Cable Meets UL 83: Thermoplastic-Insulated Wires and Cables Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords Designated Type AC per NEC Article 320 Meets UL 2556: Wire and Cable Test Methods Meets NEC Articles: 250.94, 250.118(8), 300.22(C), 320, 517.13 and 645 Version V4.0 Generated 8/2/18 www.nexans.us Page 6 / 87

ENERGEX AC HCF Green Striped Armor CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C ENERGEX AC HCF GREEN STRIPED ARMOR Part Number 250 ft coil1000 ft reel Number of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal Diameter Approximate Net over Armor Cable Weight Ampacity (Amps) inches mm lb/kft kg/km 60ºC75ºC90ºC 671560 672170 2 12 (1) 12 (1) white/black 0.49 12.4 133 198 20 20 20 672188 672196 3 12 (1) 12 (1) white/black/red 0.52 13.2 157 234 20 20 20 673426 673434 4 12 (1) 12 (1) white/black/red/blue 0.55 13.9 187 278 20¹ 20¹ 20¹ 673715 2 10 (1) 10 (1) white/black 0.50 12.8 181 269 30 30 30 3 10 (1) 10 (1) white/black/red 0.54 13.6 226 336 30 30 30 673756 4 10 (1) 10 (1) white/black/red/blue 0.59 14.9 279 415 30¹ 30¹ 30¹ Bend Radius: 7 overall diameter 2 12 (19) 12 (19) white/black 0.49 12.4 133 198 20 20 20 3 12 (19) 12 (19) white/black/red 0.52 13.2 157 234 20 20 20 Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. 60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AWG throu gh 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AW G. 90 C - Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings se e NEC Table 310.15(B) (16). NEC Article 240.4(D) requires that overcurrent protection not exceed 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temprature and num ber of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). ¹ Where the 4th (white) conductor is the neutral of a balanced 3 phase system. SELLING INFORMATION Product Features Version V4.0 Generated 8/2/18 www.nexans.us Page 7 / 87

ENERGEX AC HCF Green Striped Armor Cables are UL listed as Type AC, 600 V UL listed insulated conductors UL listed for use in cable trays per NEC Article 320.10(2) Temperature rating of 90ºC dry Excellent mechanical and physical properties Lightweight aluminum armor with intermittent green stripe to identify HCF cable Standard Nexans ENERGEX AC-HCF is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts Version V4.0 Generated 8/2/18 www.nexans.us Page 8 / 87

ENERGEX AC Aluminum Armored AC Cable UL Type ACTHH, 600 V, 90 C dry rated - Copper Conductors - RoHS compliant STANDARDS National UL 4; UL 83 DESCRIPTION Applications ENERGEX AC cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installations in accordance to NEC Article 320. These cables may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. Nexans ACTHH cable is RoHS compliant. Construction Conductor: Solid conductors are soft bare annealed copper to ASTM B3. Stranded conductors are soft bare annealed copper to ASTM B3 and ASTM B8. Insulation: PVC/Nylon type THHN in accordance to UL 83, flame resistant, meeting UL VW-1 flame test. Bond Wire: Longitudinal aluminum bond wire in continuous contact with armor. Assembly: Conductors are individually paper wrapped and cabled with a marker tape/core protection tape combination which assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: ALUMINUM ARMORED CABLE NOT FOR USE ON DC CIRCUITS / CAUTION NOT TO BE USED WITH SET SCREW CONNECTOR / FOR CT USE LEAD FREE (MFG DATE) Specifications: Meets UL 4: Armored Cable Meets UL 83: Thermoplastic-Insulated Wires and Cables Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type AC per NEC Article 320 Version 4.0 Generated 8/2/18 www.nexans.us Page 9 / 87

ENERGEX AC CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C ENERGEX AC Number of Conductors Conductor Size AWG Circuit Conductor Color Code Nominal Diameter over Armor Approximate Net Cable Weight Ampacity (Amps) inches mm lb/kft kg/km 60ºC 75ºC 90ºC 2 14 (1) white/black 0.48 12.1 89 132 15 15 15 3 14 (1) white/black/red 0.50 12.6 109 162 15 15 15 2 12 (1) white/black 0.50 12.8 109 162 20 20 20 3 12 (1) white/black/red 0.52 13.3 137 204 20 20 20 4 12 (1) white/black/red/blue 0.56 14.2 168 250 20¹ 20¹ 20¹ 2 10 (1) white/black 0.56 14.3 146 217 30 30 30 3 10 (1) white/black/red 0.59 15.0 190 283 30 30 30 4 10 (1) white/black/red/blue 0.64 16.1 236 351 30¹ 30¹ 30¹ 3 8 (19) white/black/red 0.64 16.1 246 366 40 50 55 3 6 (19) white/black/red 0.74 18.7 357 531 55 65 75 Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than si ze 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B) (16). NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temprature a nd number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). ¹ Where the 4th (white) conductor is the neutral of a balanced 3 phase system. SELLING INFORMATION Product Features Version 4.0 Generated 8/2/18 www.nexans.us Page 10 / 87

ENERGEX AC Cables are UL listed as Type ACTHH, 600 V UL listed insulated conductors UL listed for use in cable trays per NEC Article 320.10(2) Temperature rating of 90ºC dry Excellent mechanical and physical properties Lightweight aluminum armor Standard Nexans ENERGEX AC is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts Version 4.0 Generated 8/2/18 www.nexans.us Page 11 / 87

ENERGEX MC 120 Aluminum Armored PVC Jacketed Aluminum Armored Jacketed MC Cable UL Type MC, 600 V, 90 C DRY - RoHS Compliant Copper Conductors STANDARDS National UL 1569; UL 83; UL 44 DESCRIPTION Applications ENERGEX MC 120 cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction in accordance with NEC Article 330. They are suitable for installation In motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. Nexans MC 120 cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 8 AWG to 2 AWG. Insulation: Colored PVC/Nylon type THHN in accordance with UL 83, flame retardant, meeting UL VW-1 flame test for sizes 14 AWG to 1 AWG. Colored cross-linked polyethylene type XHHW-2 per UL 44 for sizes 1/0 AWG and larger. Ground Wire: Green PVC/Nylon Type THHN insulation for phase conductor sizes from 14 AWG to 1 AWG, sized in accordance with NEC and UL, (green cross-linked polyethylene Type XHHW-2 for phase conductors sized 1/0 AWG and larger). Assembly: Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Jacket: Black PVC jacket. Marker Tape Print: NEXANS TYPE MC 600 VOLT FOR CT USE (SIZE) THHN (UL) E-47409 LEAD FREE (MFG DATE) Version 4.0 Generated 8/2/18 www.nexans.us Page 12 / 87

ENERGEX MC 120 Aluminum Armored PVC Jacketed Specifications Meets UL 44: Thermoset Insulated Wires and Cables (1/0 AWG and larger) Meets UL 83: Thermoplastic Insulated Wires and Cables (14 AWG to 1 AWG) Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wire, Cable, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 4.0 Generated 8/2/18 www.nexans.us Page 13 / 87

ENERGEX MC 120 Aluminum Armored PVC Jacketed ENERGEX MC 120 ALUMINUM ARMORED JACKETED Numbe r of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal Diamete r over Armor Nominal Diamete r over Jacket Approximate Net Cable Weight Ampacity (Amps) inches mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 2 14 (1) 14 (1) white/black 0.45 11.3 0.55 14.0 147 219 15 15 15 3 14 (1) 14 (1) white/black/red 0.47 12.0 0.58 14.7 166 247 15 15 15 2 12 (1) 12 (1) white/black 0.48 12.3 0.59 14.9 183 272 20 20 20 3 12 (1) 12 (1) white/black/red 0.51 13.1 0.62 15.7 210 313 20 20 20 4 12 (1) 12 (1) white/black/red/blue 0.55 14.0 0.66 16.6 238 354 20¹ 20¹ 20¹ 2 10 (1) 10 (1) white/black 0.55 14.0 0.66 16.6 239 356 30 30 30 3 10 (1) 10 (1) white/black/red 0.57 14.9 0.69 17.6 283 421 30 30 30 4 10 (1) 10 (1) white/black/red/blue 0.64 16.3 0.75 19.0 319 475 30¹ 30¹ 30¹ 2 8 (19) 10 (1) white/black 0.66 16.7 0.76 19.3 309 460 40 50 55 3 8 (19) 10 (1) white/black/red 0.71 18.1 0.82 20.8 380 566 40 50 55 4 8 (19) 10 (1) white/black/red/blue 0.78 19.7 0.88 22.4 451 671 40¹ 50¹ 55¹ 2 6 (19) 8 (19) white/black 0.74 18.9 0.85 21.5 410 610 55 65 75 3 6 (19) 8 (19) white/black/red 0.81 20.6 0.92 23.3 515 766 55 65 75 4 6 (19) 8 (19) white/black/red/blue 0.89 22.0 0.99 25.2 612 911 55¹ 65¹ 75¹ 3 4 (19) 8 (19) white/black/red 0.94 23.9 1.05 26.6 714 1063 70 85 95 4 4 (19) 8 (19) white/black/red/blue 1.06 26.8 1.16 29.5 945 1406 70¹ 85¹ 95¹ 3 2 (19) 6 (19) white/black/red 1.09 25.9 1.20 30.4 1086 1616 95 115 130 4 2 (19) 6 (19) white/black/red/blue 1.20 30.5 1.31 33.2 1345 2002 95¹ 115¹ 130¹ Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambiant temperatures. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than si ze 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B)(16). NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). ¹Where the Ampacity assuming 4th (white) conductor is the neutral of a balanced 3 phase system. Version 4.0 Generated 8/2/18 www.nexans.us Page 14 / 87

ENERGEX MC 120 Aluminum Armored PVC Jacketed SELLING INFORMATION Product Features Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article 330.10(A)(6) UL listed for use in cable trays per NEC Article 501.10(B)(1), Class II, Div.2 per NEC Article 502.10(B)(1) and Class III, Div. 1 & 2 per NEC Article 503.10(A) and with approved termination fittings. Temperature rating of 90ºC dry Excellent mechanical & physical properties Lightweight aluminum armor Nexans ENERGEX MC 120 is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW-2 insulation on sizes 14 AWG to 1 AWG Conductor sizes larger than 1/0 AWG Version 4.0 Generated 8/2/18 www.nexans.us Page 15 / 87

ENERGEX MC 120 Aluminum Armored Unjacketed Aluminum Armored, Unjacketed MC Cable, UL Type MC, 600 V, 90 C dry rated - RoHS Compliant Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 Applications ENERGEX MC 120 cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction in accordance with NEC Article 330. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645.These cables may be installed in approved raceways and as open runs of cable on a messenger.they may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. Nexans MC 120 cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 12 AWG to 2 AWG. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class B Unilay compressed stranded for sizes 1 AWG and larger. Insulation: Colored PVC/Nylon Type THHN in accordance with UL 83, flame retardant, meeting UL VW-1 flame test. Ground Wire: Green PVC/Nylon Type THHN insulation bare copper, sized in accordance with NEC and UL. Assembly: Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS-C TYPE MC 600V FOR CT USE (SIZE) THHN (UL) E-47409 Specifications Meets UL 83: Thermoplastic Insulated Wires and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wire, Cable, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version V4.0 Generated 8/2/18 www.nexans.us Page 16 / 87

ENERGEX MC 120 Aluminum Armored Unjacketed CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V4.0 Generated 8/2/18 www.nexans.us Page 17 / 87

ENERGEX MC 120 Aluminum Armored Unjacketed ENERGEX MC 120 ALUMINUM ARMORED UNJACKETED Nominal Diamete Part Number r Approximate Net Ampacity ConductorGround over Armor Cable Weight (Amps) Number of Size Size Circuit Conductor 250 ft coil1000 ft reelconductors AWG AWG Color Code inches mm lb/kft kg/km 60 C75 C90 C 618777 642876 2 14 (1) 14 (1) white/black 0.45 11.3 87 129 15 15 15 618785 642884 3 14 (1) 14 (1) white/black/red 0.47 12.0 106 158 15 15 15 670050 670051 4 14 (1) 14 (1) white/black/red/blue 0.51 12.8 123 183 15¹ 15¹ 15¹ 618793 635045 2 12 (1) 12 (1) white/black 0.48 12.3 118 176 20 20 20 618801 635052 3 12 (1) 12 (1) white/black/red 0.51 13.1 145 216 20 20 20 618819 635060 4 12 (1) 12 (1) white/black/red/blue 0.55 14.0 173 257 20¹ 20¹ 20¹ 618827 636977 2 10 (1) 10 (1) white/black 0.55 14.0 164 244 30 30 30 618835 636985 3 10 (1) 10 (1) white/black/red 0.59 14.9 207 308 30 30 30 618843 640177 4 10 (1) 10 (1) white/black/red/blue 0.64 16.3 244 363 30¹ 30¹ 30¹ 642892 642900 2 12 (19) 12 (19) white/black 0.48 12.3 118 176 20 20 20 644997 645002 3 12 (19) 12 (19) white/black/red 0.51 13.1 145 216 20 20 20 645010 645028 4 12 (19) 12 (19)white/black/red/blue 0.55 14.0 173 257 20¹ 20¹ 20¹ 672972 672980 2 10 (19) 10 (19) white/black 0.55 14.0 164 244 30 30 30 672576 672584 3 10 (19) 10 (19) white/black/red 0.58 14.9 207 308 30 30 30 670017 672634 4 10 (19) 10 (19)white/black/red/blue 0.64 16.3 244 363 30¹ 30¹ 30¹ 200 ft reel 500 ft reel 670085 670190 2 8 (19) 8 (19) white/black 0.66 16.7 229 341 40 50 55 670086 642918 3 8 (19) 8 (19) white/black/red 0.71 18.1 300 446 40 50 55 --- 670208 4 8 (19) 10 (19)white/black/red/blue 0.78 19.7 371 552 40¹ 50¹ 55¹ 125 ft reel 500 ft reel 670088 670182 2 6 (19) 8 (19) white/black 0.74 18.9 330 491 55 65 75 670089 643445 3 6 (19) 8 (19) white/black/red 0.81 20.6 435 647 55 65 75 --- 670174 4 6 (19) 8 (19) white/black/red/blue 0.89 22.5 541 805 55¹ 65¹ 75¹ --- 670539 3 4 (19) 8 (19) white/black/red 0.94 23.9 624 929 70 85 95 --- --- 4 4 (19) 8 (19) white/black/red/blue 1.06 26.8 855 1272 70¹ 85¹ 95¹ --- 673848 3 3 (19) 6 (19) white/black/red 1.02 25.8 795 1183 85 100 110 --- 670237 4 3 (19) 6 (19) white/black/red/blue 1.13 28.7 1049 1561 85¹ 100¹ 110¹ --- 670521 3 2 (19) 6 (19) white/black/red 1.09 27.7 966 1438 95 115 130 --- 673871 4 2 (19) 6 (19) white/black/red/blue 1.20 30.5 1245 1853 95¹ 115¹ 130¹ --- --- 3 1 (19) 6 (19) white/black/red 1.20 30.6 1427 2124 110 130 150 --- --- 3 1/0 (19) 6 (19) white/black/red 1.27 32.3 1585 2359 125 150 170 Bend Radius: 7 x overall diameter *60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor larger than 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. Version Notes: V4.0 Generated 8/2/18 www.nexans.us Page 18 / 87 Where stated, nominal and approximate value are provided for information purposes only and are subje ct to standard manufacturing tolerances. Ampacities are in accordance with NEC Articles 310.15 and 334.80, which are based on NEC Table 310.15(B) (16) for conductors in a raceway or direct buried at 30

ENERGEX MC 120 Aluminum Armored Unjacketed SELLING INFORMATION Product Features Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article 330.10(A)(6) or NEC Article 330.10(6) For use in Class 1, Div. 2 per NEC Article 501.10(B)(1), Class II, Div.2 per NEC Article 502.10(B)(1) and Class III, Div. 1 & 2 per NEC Article 503.10 with approved termination fittings. Temperature rating of 90ºC dry Suitable for direct burial Excellent mechanical & physical properties Lightweight aluminum armor Nexans ENERGEX MC 120 is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW-2 insulation Version V4.0 Generated 8/2/18 www.nexans.us Page 19 / 87

ENERGEX MC 120 Steel Armored Steel Armored MC Cable, UL Type MC, 600 V, 90 C dry rated - RoHS Compliant, Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 Applications ENERGEX MC 120 cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. Nexans MC 120 cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 12 AWG to 6 AWG. Insulation: PVC/Nylon Type THHN in accordance with UL 83, flame retardant meeting UL VW-1 flame test. Ground Wire: Green PVC/Nylon Type THHN insulation sized in accordance with NEC and UL. Assembly: Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking galvanized steel tape armor applied directly over the core. Marker Tape Print NEXANS-C TYPE MC 600V FOR CT USE (SIZE) THHN (UL) E-47409 Specifications Meets UL 83: Thermoplastic Insulated Wires and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords Meets UL 2256: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version V4.0 Generated 8/2/18 www.nexans.us Page 20 / 87

ENERGEX MC 120 Steel Armored CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V4.0 Generated 8/2/18 www.nexans.us Page 21 / 87

ENERGEX MC 120 Steel Armored ENERGEX MC 120 STEEL ARMORED CABLE Part number 250 ft coil 1000 ft reel Numbe r of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal Diamete r over Armor Approximate Net Cable Weight Ampacity (Amps) inches mm lb/kft kg/km 60ºC 75ºC 90ºC 670033 670040 2 14 (1) 14 (1) white/black 0.44 11.2 144 214 15 15 15 670035-3 14 (1) 14 (1) white/black/red 0.47 11.9 167 249 15 15 15 670036 670043 4 14 (1) 14 (1) white/black/red/blue 0.50 12.7 189 281 15¹ 15¹ 15¹ 670011 670044 2 12 (1) 12 (1) white/black 0.48 12.1 179 266 20 20 20 670012 670045 3 12 (1) 12 (1) white/black/red 0.51 12.9 213 317 20 20 20 670013 670046 4 12 (1) 12 (1) white/black/red/blue 0.54 13.8 247 368 20¹ 20¹ 20¹ 670014 670047 2 10 (1) 10 (1) white/black 0.54 13.8 238 354 30 30 30 670015 670048 3 10 (1) 10 (1) white/black/red 0.58 14.8 287 427 30 30 30 670016 670049 4 10 (1) 10 (1) white/black/red/blue 0.63 16.0 333 496 30¹ 30¹ 30¹ - - 2 12 (19) 12 (19) white/black 0.48 12.3 215 320 20 20 20 - - 3 12 (19) 12 (19) white/black/red 0.51 13.1 252 375 20 20 20 - - 4 12 (19) 12 (19) white/black/red/blue 0.55 14.0 290 432 20¹ 20¹ 20¹ - - 2 10 (19) 10 (19) white/black 0.55 14.0 164 244 30 30 30 - - 3 10 (19) 10 (19) white/black/red 0.59 14.9 207 308 30 30 30 - - 4 10 (19) 10 (19) white/black/red/blue 0.64 16.3 244 363 30¹ 30¹ 30¹ - - 3 8 (19) 10 (19) white/black/red 0.71 18.1 300 446 40 50 55 - - 3 6 (19) 8 (19) white/black/red 0.81 20.6 435 647 55 65 75 Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table 310.15(B)(16) for conductors in a raceway at 30 C ambient temperatures. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AWG through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B)(16). NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). ¹Where the 4th (white) conductor is the neutral of a balanced 3 phase system. Version V4.0 Generated 8/2/18 www.nexans.us Page 22 / 87

ENERGEX MC 120 Steel Armored SELLING INFORMATION Product Features Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article 330.10(A)(6) For use in Class I, Div. 2 per NEC Article 501.10(B)(1), Class II, Div.2 per NEC Article 502.10(B)(1) and Class III, Div. 1 & 2 per NEC Article 503.10 with approved termination fittings. Temperature rating of 90ºC dry Excellent mechanical & physical properties Nexans ENERGEX MC 120 is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW-2 insulation Version V4.0 Generated 8/2/18 www.nexans.us Page 23 / 87

ENERGEX MC 277 Aluminum Armored Aluminum Armored MC Cable 277 Volts and Special Color Codes UL Type MC, 600 V, 90ºC dry rated - RoHS Compliant Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 ENERGEX MC 277 cables may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction in accordance with NEC Article 330. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. Nexans MC 277 cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 12 AWG to 6 AWG. Insulation:Colored PVC/Nylon Type THHN in accordance with UL 83, flame retardant, meeting UL VW-1 flame test. Ground Wire:Green PVC/Nylon Type THHN insulation sized in accordance with NEC and UL. Assembly:Conductors are cabled with grounding wires. A marker tape / core protection tape combination assembles the core in an essentially round configuration. Armor:Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS-C TYPE MC 600V FOR CT USE (SIZE) THHN (UL) E-47409 Specifications Meets UL 83: Thermoplastic-Insulated Wire and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad cables Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version V4.0 Generated 8/2/18 www.nexans.us Page 24 / 87

ENERGEX MC 277 Aluminum Armored CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V4.0 Generated 8/2/18 www.nexans.us Page 25 / 87

ENERGEX MC 277 Aluminum Armored ENERGEX MC 277 ALUMINUM ARMORED MC CABLE Part Number 250 ft coil 1000 ft reel Number of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal DiameteApproximate r Net over Armor Cable Weight indicative ratings only see and shall NEC not be binding Table on Nexans 310.15(B)(16). or be treated as constituting a representation on the part of Nexans. Version V4.0 Generated 8/2/18 www.nexans.us Page 26 / 87 Ampacity* (Amps) inches mm lb/kft kg/km 60 C 75 C 90 C 654269 652537 2 12 (1) 12 (1) brown/gray 0.48 12.3 118 176 20 20 20 654251 671917 2 12 (1) 12 (1) orange/gray 0.48 12.3 118 176 20 20 20 654244 671925 2 12 (1) 12 (1) yellow/gray 0.48 12.3 118 176 20 20 20 --- --- 2 12 (1) 12 (1) purple/gray 0.48 12.3 118 176 20 20 20 --- --- 2 12 (1) 12 (1) brown/yellow 0.48 12.3 118 176 20 20 20 652263 670570 2 12 (1) 12 (1) red/white 0.48 12.3 118 176 20 20 20 652271 670554 2 12 (1) 12 (1) blue/white 0.48 12.3 118 176 20 20 20 669762 669770 3 12 (1) 12 (1) brown/orange/gray 0.51 13.1 145 216 20 20 20 --- --- 3 12 (1) 12 (1) brown/purple/gray 0.51 13.1 145 216 20 20 20 --- --- 3 12 (1) 12 (1) purple/yellow/gray 0.51 13.1 145 216 20 20 20 --- --- 3 12 (1) 12 (1) brown/yellow/gray 0.51 13.1 145 216 20 20 20 --- --- 3 12 (1) 12 (1) red/blue/white 0.51 13.1 145 216 20 20 20 --- --- 3 12 (1) 12 (1) black/blue/white 0.51 13.1 145 216 20 20 20 671891 669812 4 12 (1) 12 (1) brown/orange/yellow/gray 0.55 14.0 173 257 20¹ 20¹ 20¹ --- --- 4 12 (1) 12 (1) brown/purple/yellow/gray 0.55 14.0 173 257 20¹ 20¹ 20¹ --- 672923 2 10 (1) 10 (1) brown/gray 0.55 14.0 164 244 30 30 30 --- 672949 3 10 (1) 10 (1) brown/orange/gray 0.59 14.9 207 308 30 30 30 672592 672600 4 10 (1) 10 (1) brown/orange/yellow/gray 0.64 16.3 244 363 30¹ 30¹ 30¹ --- --- 2 12 (19) 12 (19) brown/gray 0.48 12.3 118 176 20 20 20 --- --- 3 12 (19) 12 (19) brown/orange/gray 0.51 13.1 145 216 20 20 20 --- --- 4 12 (19) 12 (19) brown/orange/yellow/gray 0.55 14.0 173 257 20¹ 20¹ 20¹ --- --- 2 10 (19) 10 (19) brown/gray 0.55 14.0 164 244 30 30 30 --- --- 3 10 (19) 10 (19) brown/orange/gray 0.59 14.9 207 308 30 30 30 --- --- 4 10 (19) 10 (19) brown/orange/yellow/gray 0.64 16.3 244 363 30¹ 30¹ 30¹ 500 ft reel 1000 ft reel 642918 ---- 3 8 (19) 10 (19) brown/orange/gray 0.71 18.1 300 446 40 50 55 643445 --- 3 6 (19) 8 (19) brown/orange/gray 0.81 20.6 435 647 55 65 75 Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table 310.15(B)(16) for conductors in a raceway at 30 C ambient temperatures. 60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AWG through 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C - Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G).. ¹Where the 4th (gray) conductor is the neutral of a balanced 3 phase system.

ENERGEX MC 277 Aluminum Armored SELLING INFORMATION Product features * Cables are UL listed as Type MC, 600 V * UL listed insulated conductors * Fire Wall Penetration rated depending on type of installation and fire-stop system used * UL listed for use in cable trays per NEC Article 330.10(A)(6) * For use in Class I, Div. 2 per NEC Article 501.10(B)(1), Class II, Div. 2 per NEC Article 502.10(B)(1)(6) and Class III, Div. 1 & 2 per NEC Article 503.10 with approved termination fittings. * Temperature rating of 90 C dry * Excellent mechanical & physical properties * Lightweight aluminum armor * Nexans ENERGEX MC 277 is RoHS compliant Options The following constructions can be provided on special orders: * Special conductor counts * XHHW-2 insulation Version V4.0 Generated 8/2/18 www.nexans.us Page 27 / 87

ENERGEX MC Aluminum Feeder Cable Industrial Cables USA.IndustrialCable@nexans.com Aluminum Interlock Armored Power Feeder Cable, UL Type MC, 600 V, 90 C dry rated - Unjacketed, 3 or 4 aluminum conductors - XLPE insulated, with bare aluminum ground wire - LEAD FREE STANDARDS National UL 1569; UL 44 DESCRIPTION Applications Unjacketed aluminum conductor MC cable is suitable and allowed by the NEC for use in the following applications: Power lighting, control and signal circuits and as branch circuits and power feeders in industrial, commercial, institutional and residential installations up to 600 volts. Fished or embedded in plaster and concrete except in damp or wet locations. Aerial cable when fixed to a messenger support cable. Concealed or exposed applications. Cable trays and other raceways. Class I and II, Division 2 as well as Class III, Division 1 and 2 hazardous locations. Under raised floors of information technology rooms. Environmental air-handling spaces per NEC Article 300.22 (C). Places of Assembly per NEC Article 518.4 and theaters per NEC Article 520.5. Construction Conductor: Compact stranded AA-8000 series aluminum conductor material (ACM) per ASTM B801 Class B or ASTM B836 (Single Input Wire). Insulation: Colored crosslinked polyethylene (XLPE) type XHHW-2 per UL 44. Ground Wire: Bare compact stranded AA-8000 series aluminum alloy (ACM). Assembly: Insulated conductors are cabled with a bare ground wire, interstices are filled with suitable non-hygroscopic fillers, as required. A binder tape of synthetic material assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied over the assembled core. Conductor Identification: 3/C black, red, white 4/C black, red, blue, white Specifications Meets UL 44, XHHW-2 600 V conductors Meets UL 1569 requirements for Type MC, Metal Clad cables Designated Type MC per NEC Article 330 Version V4.0 Generated 8/2/18 www.nexans.us Page 28 / 87

ENERGEX MC Aluminum Feeder Cable Industrial Cables USA.IndustrialCable@nexans.com CHARACTERISTICS Construction characteristics Conductor material Aluminum Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C ENERGEX MC ALUMINUM FEEDER CABLE 3 Conductors with Bare Ground Part Number (Color Coded Conductors) Conductor Size Insulation Thickness Ground Wire Size Nominal Diameter over Armor Approximate Net Cable Weight Ampacity (Amps) AWG/kcmil mils mm AWG inches mm lb/kft kg/km 60ºC 75ºC 90ºC 603520 6 45 1.14 6 0.776 19.71 210 312 40 50 55 603521 4 45 1.14 6 0.876 22.26 285 424 55 65 75 603523* 2 45 1.14 6 1.008 25.60 396 589 75 90 100 603524 1 55 1.40 4 1.124 28.54 503 748 85 100 115 603525* 1/0 55 1.40 4 1.198 30.43 586 872 100 120 135 603526* 2/0 55 1.40 4 1.285 32.63 687 1022 115 135 150 603527* 3/0 55 1.40 4 1.388 35.24 814 1211 130 155 175 603528* 4/0 55 1.40 2 1.499 38.07 992 1476 150 180 205 603529* 250 65 1.65 2 1.781 45.23 1172 1744 170 205 230 603531* 350 65 1.65 2 1.859 47.21 1521 2264 210 250 280 603542 400 65 1.65 1 1.951 49.55 1709 2544 225 270 305 603532* 500 65 1.65 1 2.248 57.11 2249 3346 260 310 350 603562* 750 80 2.03 1/0 2.680 68.07 3213 4781 320 385 435 *Denotes stock item. Other constructions available upon request. Version V4.0 Generated 8/2/18 www.nexans.us Page 29 / 87

ENERGEX MC Aluminum Feeder Cable Industrial Cables USA.IndustrialCable@nexans.com 3 CONDUCTORS WITH BARE GROUND CONNECTORS Cable Part Number (Color Coded Conductors) Conductor Size Crouse Hinds / Eaton Bridgeport Appleton AWG or kcmil ACB Series DC2 DCX2 AC 90 603520 6 ACB50 682-DC2 AC-95 603521 4 ACB75 683-DC2 AC-95 603523 2 ACB100 683-DC2 683-DCX2 AC-95 603524 1 ACB100 684-DC2 684-DCX2 AC-96 603525 1/0 ACB100 684-DC2 684-DCX2 AC-96 603526 2/0 ACB125 685-DC2 685-DCX2 AC-96 603527 3/0 ACB125 685-DC2 685-DCX2 AC-97 603528 4/0 ACB125 685-DC2 685-DCX2 AC-97 603529 250 ACB150 686-DC2 686-DCX2 AC-98 603531 350 ACB150 686-DC2 AC-99 603542 400 ACB200 686-DC2 AC-99 603532 500 ACB200 687-DC2 687-DCX2 AC-985 603562 750 ACB250 688-DC2 688-DCX2 AC-250-D Version V4.0 Generated 8/2/18 www.nexans.us Page 30 / 87

ENERGEX MC Aluminum Feeder Cable Industrial Cables USA.IndustrialCable@nexans.com ENERGEX MC ALUMINUM FEEDER CABLE 4 Conductors with Bare Ground Part Number (Color Coded Conductors) Conductor Size Insulation Thickness Ground Wire Size Nominal Diameter over Armor Approximate Net Cable Weight Ampacity (Amps) AWG/kcmil inches mm AWG inches mm lb/kft kg/km 60ºC 75ºC 90ºC 603533 6 0.045 1.14 6 0.85 21.6 269 400 40 50 55 603534 4 0.045 1.14 6 0.99 25.1 384 571 55 65 75 603535* 2 0.045 1.14 6 1.11 28.2 499 742 75 90 100 603536 1 0.055 1.40 4 1.24 31.6 655 974 85 100 115 603537* 1/0 0.055 1.40 4 1.33 33.7 767 1142 100 120 135 603538* 2/0 0.055 1.40 4 1.42 36.0 903 1343 115 135 150 603539 3/0 0.055 1.40 4 1.54 39.1 1077 1603 130 155 175 603540* 4/0 0.055 1.40 2 1.66 42.2 1313 1954 150 180 205 603541 250 0.065 1.65 2 1.81 46.1 1496 2227 170 205 230 603874* 250 0.065 1.65 1 1.83 46.6 1518 2259 170 205 230 603580 350 0.065 1.65 2 2.18 55.2 2152 3202 210 250 280 603876* 350 0.065 1.65 1/0 2.19 55.6 2195 3266 210 250 280 603543 400 0.065 1.65 1 2.29 58.1 2415 3593 225 270 305 603581 500 0.065 1.65 1 2.47 62.9 2881 4288 260 310 350 603878 500 0.065 1.65 2/0 2.47 62.8 2919 4344 260 310 350 603757* 500 0.065 1.65 250 2.53 64.3 3048 4536 260 310 350 603574* 750 0.080 2.03 3/0 2.94 74.8 4199 6249 320 385 435 Bending Radius: Fixed position: 7 x cable overall diameter During pulling: 12 x cable overall diameter 60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 6 AWG throug h 1 AWG. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AW G. 90 C - For ampacity derating purposes. Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature and 90 C rated conductors. Ampacities for four conductor cables apply where the 4th conductor is the neutral of a balanced 3 phase system. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B)(16). For load diversity of 50%, refer to NEC Table B.310.15(B)(2)(11). * Denotes stock item. Other constructions available upon request. Version V4.0 Generated 8/2/18 www.nexans.us Page 31 / 87

ENERGEX MC Aluminum Feeder Cable Industrial Cables USA.IndustrialCable@nexans.com 4 CONDUCTORS WITH BARE GROUND CONNECTORS Cable Part Number (Color Coded Conductors) Conductor Size Crouse Hinds / Eaton Bridgeport Appleton AWG or kcmil ACB Series DC2 DCX2 AC 90 603533 6 ACB75 682-DC2 AC-95 603534 4 ACB75 683-DC2 683-DCX2 AC-95 603535 2 ACB100 684-DC2 684-DCX2 AC-96 603536 1 ACB100 684-DC2 684-DCX2 AC-96 603537 1/0 ACB125 685-DC2 685-DCX2 AC-97 603538 2/0 ACB125 685-DC2 685-DCX2 AC-97 603539 3/0 ACB125 686-DCX2 AC-98 603540 4/0 ACB150 686-DCX2 AC-98 603541 250 ACB150 686-DC2 686-DCX2 AC-98 603874 250 ACB150 686-DC2 686-DCX2 AC-98 603580 350 ACB200 687-DC2 687-DCX2 AC-985 603876 350 ACB200 687-DC2 687-DCX2 AC-985 603543 400 ACB200 687-DC2 687-DCX2 AC-985 603581 500 ACB250 688-DC2 688-DCX2 AC-250-D 603878 500 ACB250 688-DC2 688-DCX2 AC-250-D 603757 500 ACB250 688-DC2 688-DCX2 AC-250-D 603574 750 ACB250 689-DC2 689-DCX2 AC-250-D SELLING INFORMATION Product Features Cables are UL listed as Type MC, rated 600 V UL listed XHHW-2 insulated conductors Cables pass UL 1685 and IEEE 383 vertical tray fire tests at 70,000 BTU/hr, ICEA T-29-520 fire test at 210,000 BTU/ hr, IEEE 1202 and CSA FT4 Fire wall penetration rated depending on type of installation and fire-stop system used Cables exhibit a -25 C cold bend rating with suitable precautions Temperature rating of 90 Cdry 130 C emergency rating and 250 C short circuit rating Excellent mechanical and physical properties RoHS Compliant Suitable for use in cabletray Can be installed in hazardous locations as permitted by the NEC Version V4.0 Generated 8/2/18 www.nexans.us Page 32 / 87

ENERGEX MC Ground Plus Aluminum Armored Isolated Ground MC Cable UL Type MC, 600 V, 90 C dry rated - RoHS Compliant Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 Applications ENERGEX MC Ground Plus cables are for use in applications where isolated, dedicated or redundant ground is required. They may be used for branch, feeder and service for distribution in commercial, industrial and multi-residential construction. They are also suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. Nexans MC Ground Plus cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 8 AWG and 6 AWG. Insulation: PVC/Nylon type THHN in accordance to UL 83, flame resistant, meeting UL VW-1 flame test. Ground Wires: Sized in accordance with NEC and UL, one with green THHN insulation, one with green THHN insulation with a yellow stripe. Assembly: Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS-C TYPE MC 600V FOR CT USE (SIZE) THHN (UL) E-47409 Specifications Meets UL 83: Thermoplastic Insulated Wires and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wire, Cable, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version 4.0 Generated 8/2/18 www.nexans.us Page 33 / 87

ENERGEX MC Ground Plus CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 4.0 Generated 8/2/18 www.nexans.us Page 34 / 87

ENERGEX MC Ground Plus ENERGEX MC GROUND PLUS Part Number 250 ft coil 1000 ft reel Number of Conductors Conductor Size AWG Ground Size AWG Circuit Conductor Color Code Nominal Approximate Diameter Net over Jacket Cable Weight Ampacity (Amps) inches mm lb/kft kg/km 60ºC 75ºC 90ºC - - 2 14 (1) 2 x 14 (1) white/black 0.48 12.1 106 158 15 15 15 - - 3 14 (1) 2 x 14 (1) white/black/red 0.49 12.3 123 183 15 15 15 - - 4 14 (1) 2 x 14 (1) white/black/red/blue 0.53 13.3 140 208 15¹ 15¹ 15¹ 671818 671826 2 12 (1) 2 x 12 (1) white/black 0.51 13.1 145 216 20 20 20 - - 3 12 (1) 2 x 12 (1) white/black/red 0.55 14.0 173 257 20 20 20 - - 4 12 (1) 2 x 12 (1) white/black/red/blue 0.58 14.8 201 299 20¹ 20¹ 20¹ - - 2 10 (1) 2 x 10 (1) white/black 0.58 14.0 207 308 30 30 30 - - 3 10 (1) 2 x 10 (1) white/black/red 0.62 15.8 244 363 30 30 30 - - 4 10 (1) 2 x 10 (1) white/black/red/blue 0.68 17.2 281 418 30¹ 30¹ 30¹ - - 2 8(19) 2 x 10 (1) white/black 0.66 16.8 300 446 40 50 55 - - 3 8(19) 2 x 10 (1) white/black/red 0.75 19.1 371 552 40 50 55 - - 4 8(19) 2 x 10 (1) white/black/red/blue 0.83 21.0 442 658 40¹ 50¹ 55¹ - - 2 6(19) 2 x 8(19) white/black 0.82 20.9 435 647 55 65 75 - - 3 6(19) 2 x 8(19) white/black/red 0.90 22.9 541 805 55 65 75 - - 4 6(19) 2 x 8(19) white/black/red/blue 0.98 24.8 647 963 55¹ 65¹ 75¹ Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table 310.15(B) (16) for conductors in a raceway or direct buried at 30 C ambient temperature. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than si ze 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B) (16). NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temprature a nd number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4 (E) through (G). ¹ Where the 4th (white) conductor is the neutral of a balanced 3 phase system. Version 4.0 Generated 8/2/18 www.nexans.us Page 35 / 87

ENERGEX MC Ground Plus SELLING INFORMATION Product Features Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article 330.10(A)(6) For use in Class 1, Div. 2 per NEC Article 501.10(B)(1), Class II, Div.2 per NEC Article 502.10(B)(1) and Class III, Div. 1 & 2 per NEC Article 503.10 with approved termination fittings. Temperature rating of 90ºC dry Excellent mechanical and physical properties Lightweight aluminum armor Nexans ENERGEX MC Ground Plus is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW insulation Version 4.0 Generated 8/2/18 www.nexans.us Page 36 / 87

ENERGEX MC Mega Neutral Aluminum Armored MC Cable, UL Type MC, 600 V, 90 C dry rated - RoHS Compliant Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 Applications ENERGEX MC Mega Neutral cables are for use in applications where increased neutral capacity is required due to non-linear switching loads which can cause additive harmonic currents to be present on the neutral conductors. They may be used for branch, feeder and service for distribution in commercial, industrial, and multiresidential construction. It is also suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY. Nexans MC Mega Neutral Cable is RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Stranded soft bare annealed copper per ASTM B3 and ASTM B8 Class C compressed stranded for sizes 8 AWG and 6 AWG. Insulation: PVC/Nylon Type THHN in accordance to UL 83, flame resistant, meeting UL VW-1 flame test. Neutral Conductor: Soft copper, with white THHN insulation and colored stripe where indicated. Cable has either one neutral per phase conductor or one over-sized neutral per two phase conductors. Ground Wire(s): Sized in accordance with NEC and UL, one with green THHN insulation, one with green THHN insulation with a yellow stripe (in cables with two grounds). Assembly: Conductors are cabled with neutrals and grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS TYPE MC 600V FOR CT USE 12/4C - 10/2C THHN (UL) E-47409 Version 4.0 Generated 8/2/18 www.nexans.us Page 37 / 87

ENERGEX MC Mega Neutral Specifications Meets UL 83: Thermoplastic-Insulated Wires and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wire, Cable, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version 4.0 Generated 8/2/18 www.nexans.us Page 38 / 87

ENERGEX MC Mega Neutral CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 4.0 Generated 8/2/18 www.nexans.us Page 39 / 87

ENERGEX MC Mega Neutral ENERGEX MC MEGA NEUTRAL Neutral Per Leg (NPL) Part Number 250 ft coil 1000 ft reel Number ofconductor Power Size Conductors AWG Neutral Size AWG Ground Size AWG Circuit Conductor Color Code NominalApproximate Diameter Net White Neutralover Armor Cable Weight Stripe Color Ampacity (Amps) inchesmmlb/kft kg/km 60ºC75ºC90ºC 671628671602 2 12 (1) 2x12 (1) 2x12 (1) black/red black/red 0.52 13.1 120 179 20 20 20 671636671586 3 12 (1) 3x12 (1) 2x12 (1) black/red/blue black/red/blue 0.53 13.4 163 243 20 20 20 - - 4 12 (1) 3x12 (1) 2x12 (1)black/red/pink/tan none/pink/tan 0.55 13.9 191 284 20¹ 20¹ 20¹ - - 2 10 (1) 2x10 (1)2x10 (1) black/red black/red 0.60 15.3 226 336 30 30 30 675413675405 3 10 (1) 3x10 (1)2x10 (1) black/red/blue black/red/blue 0.66 16.6 300 446 30 30 30 Oversize Neutral Conductor (ONC) Part Number 250 ft coil 1000 ft reel Number ofconductor Power Size Conductors AWG Neutral Size AWG Ground Size AWG Circuit Conductor Color Code NominalApproximate Diameter Net White Neutralover Armor Cable Weight Stripe Color Ampacity (Amps) inchesmmlb/kft kg/km 60ºC75ºC90ºC - 672097 1 12 (1) 10 (1) 12 (1) black no stripe 0.52 13.1 120 179 20 20 20-671644 2 12 (1) 10 (1) 12 (1) black/red no stripe 0.53 13.4 163 243 20 20 20-671578 3 12 (1) 10 (1) 12 (1) black/red/blue no stripe 0.55 13.9 191 284 20 20 20-671651 3 12 (1) 8 (19) 12 (1) black/red/blue no stripe 0.60 15.3 226 336 20 20 20-672212 4 12 (1) 2x10 (1)2x12 (1)black/red/blue/pink none/pink 0.66 16.6 300 446 20¹ 20¹ 20¹ - 670588 2 10 (1) 8 (19) 10 (1) black/red no stripe 0.60 15.1 215 320 30 30 30-670596 3 10 (1) 6 (19) 10 (1) black/red/blue no stripe 0.58 14.6 320 476 30 30 30-674911 4 10 (1) 2x8 (19)2x10 (1)black/red/blue/pink none/pink 0.79 20.1 400 595 30¹ 30¹ 30¹ Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table 310.15(B) (16) for conductors in a raceway or direct buried at 30 C ambient temperatures. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than si ze 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B)(16). NEC Article 240.4 (D) requires that overcurrent protection not exceed 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductor s have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). ¹Where the 4th (white) conductor is the neutral of a balanced 3 phase system. Version 4.0 Generated 8/2/18 www.nexans.us Page 40 / 87

ENERGEX MC Mega Neutral SELLING INFORMATION Product Features Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article 330.10(A)(6) For use in Class 1, Div. 2 per NEC Article 501.10(B)(1), Class II, Div.2 per NEC Article 502.10(B)(1) and Class III, Div. 1 & 2 per NEC Article 503.10(A) and (B) with approved termination fittings. Temperature rating of 90ºC dry Excellent mechanical and physical properties Lightweight aluminum armor Nexans ENERGEX MC Mega Neutral is RoHs compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW-2 insulation Version 4.0 Generated 8/2/18 www.nexans.us Page 41 / 87

ENERGEX MC Multi Conductor Aluminum Armored MC Cable UL Type MC, 600 V, 90 C dry rated - RoHS Compliant Copper Conductors DESCRIPTION STANDARDS National UL 1479; UL 1569; UL 83 Applications ENERGEX MC Multi Conductor cables are designed for applications that require six or more conductors. They may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) only. Nexans MC Multi Conductor Cables are RoHS compliant. Construction Conductor: Solid soft bare annealed copper per ASTM B3. Insulation: PVC/Nylon type THHN in accordance to UL 83, flame resistant, meeting UL VW-1 flame test. Ground Wire: Green PVC/Nylon Type THHN insulation, sized in accordance with NEC and UL. Assembly: Conductors are cabled with grounding wires. A marker tape/core protection tape combination assembles the core in an essentially round configuration. Armor: Interlocking aluminum tape armor applied directly over the core. Marker Tape Print: NEXANS-C TYPE MC 600V FOR CT USE (SIZE) THHN (UL) E-47409 Color Code: (tan is stripe color) 6 conductor: black, red, white, black/tan, red/tan, white/tan 8 conductor: black, red, white, blue, black/tan, red/tan, white/tan, blue/tan Version V4.0 Generated 8/2/18 www.nexans.us Page 42 / 87

ENERGEX MC Multi Conductor Specifications Meets UL 83: Thermoplastic Insulated Wires and Cables Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to 2 AWG) Meets UL 1569: Metal Clad Cables Meets UL 1581: Reference Standard for Electrical Wire, Cable, and Flexible Cords Meets UL 2556: Wire and Cable Test Methods Designated Type MC per NEC Article 330 Version V4.0 Generated 8/2/18 www.nexans.us Page 43 / 87

ENERGEX MC Multi Conductor CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V4.0 Generated 8/2/18 www.nexans.us Page 44 / 87

ENERGEX MC Multi Conductor ENERGEX MC MULTI CONDUCTOR Part Number 1000 ft reels Number of Conductors Conductor Size AWG Ground Size AWG Nominal Diameter over Armor Approximate Net Cable Weight Ampacity (Amps) inches mm lb/kft kg/km 60ºC 75ºC 90ºC 671669 6 12 (1) 12 (1) 0.57 14.5 225 335 16 20 20 671677 8 12 (1) 12 (1) 0.65 16.4 290 432 14 18 20-10 12 (1) 12 (1) 0.70 17.8 320 476 10 13 15-12 12 (1) 12 (1) 0.75 19.1 350 521 10 13 15-14 12 (1) 12 (1) 0.80 20.3 410 610 10 13 15-16 12 (1) 12 (1) 0.83 21.0 465 692 10 13 15-18 12 (1) 12 (1) 0.84 21.2 475 707 10 13 15-20 12 (1) 12 (1) 0.87 22.1 565 841 10 13 15-24 12 (1) 12 (1) 0.95 24.1 650 967 9 11 14 673707 6 10 (1) 10 (1) 0.68 17.2 340 506 24 28 30 673699 8 10 (1) 10 (1) 0.76 19.3 390 580 21 25 28-10 10 (1) 10 (1) 0.83 21.0 470 699 15 18 20-12 10 (1) 10 (1) 0.88 22.4 560 833 15 18 20-14 10 (1) 10 (1) 0.94 23.9 635 945 15 18 20-16 10 (1) 10 (1) 0.98 24.9 730 1086 15 18 20-18 10 (1) 10 (1) 0.99 25.2 805 1198 15 18 20-20 10 (1) 10 (1) 1.03 26.0 915 1362 15 18 20-24 10 (1) 10 (1) 1.13 28.7 1130 1682 14 16 18 Bend Radius: 7 x overall diameter Notes: Dimensions and weights shown are nominal values, subject to standard industry tolerances. Ampacities are in accordance with NEC Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. 60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 AW G through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than si ze 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B) (16). NEC Article 240.4(D) requires that overcurrent protection not exceed 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). SELLING INFORMATION Product Features Version V4.0 Generated 8/2/18 www.nexans.us Page 45 / 87

ENERGEX MC Multi Conductor Cables are UL listed as Type MC, 600 V UL listed insulated conductors Fire Wall Penetration rated depending on type of installation and fire-stop system used UL listed for use in cable trays per NEC Article 330.10(A)(6) For use in Class 1, Div. 2 per NEC Article 501.10(B)(6), Class II, Div.2 per NEC Article 502.10(B)(1) and Class III, Div. 1 & 2 per NEC Article 503.10 with approved termination fittings. Temperature rating of 90ºC dry Excellent mechanical and physical properties Lightweight aluminum armor Nexans ENERGEX MC Multi Conductor is RoHS compliant Options The following constructions can be provided on special orders: Special conductor counts XHHW insulation Version V4.0 Generated 8/2/18 www.nexans.us Page 46 / 87

Direct Buried Armored and unarmored cable are available for direct burial in the earth with appropriate protection as required by the local inspection authority. All are designed for ease of installation and superior performance. Generated 8/2/18 www.nexans.us Page 47 / 87

ENERGEX 8000 RHH/RHW 2/USE 2 Aluminum XLPE Insulated Cable, ACM Aluminum Conductors, 600 Volts, 90ºC Dry or Wet - RoHS compliant DESCRIPTION STANDARDS National ICEA S-95-658; UL 854; UL 44 Application Nexans ENERGEX 8000 RHH/RHW-2/USE-2 is an AA-8000 series aluminum (ACM) conductor with cross-linked polyethylene insulation. The cable may be installed in raceways and conduits or directly buried. They are 90ºC, 600 volts per NEC Articles 310 and 338. Type USE-2 conductors are suitable as service entrance conductors which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, cables are suitable for installation in both wet and dry locations. Nexans RHH/RHW-2/USE-2 conductors are RoHS compliant. Construction Conductor: Compact stranded AA-8000 series aluminum conductor material (ACM) per ASTM B801 or ASTM B836 (Single Input Wire). Insulation: Heat, sunlight, moisture and abrasion resistant cross-lined polyethylene (XLPE) insulation per UL 854 and UL 44. Black only. Specifications Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854: (USE-2) Service Entrance Cables Federal Specification A-A-59544 ICEA 5-95-658: Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy National Electrical Code - NFPA 70 Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated CT use. Surface Print Legend (example) NEXANS-C 1/0 AWG COMPACT AA-8000-AL USE-2 OR RHH OR RHW-2 600V FOR CT USE SUN RES(UL) ROHS (MFG. DATE) Version 4.0 Generated 8/2/18 www.nexans.us Page 48 / 87

ENERGEX 8000 RHH/RHW 2/USE 2 Aluminum CHARACTERISTICS Construction characteristics Conductor material Aluminum Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 4.0 Generated 8/2/18 www.nexans.us Page 49 / 87

ENERGEX 8000 RHH/RHW 2/USE 2 Aluminum ENERGEX 8000 RHH/RHW 2/USE 2 ALUMINUM Conductor Size Nominal Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (Amps) AWG/kcmil mils mm inches mm lb/kft kg/km 60 ºC 75 ºC 90 ºC 6 (7) 60 1.52 0.29 7.4 47 70 40 50 55 4 (7) 60 1.52 0.33 8.4 66 98 55 65 75 2 (7) 60 1.52 0.39 9.9 96 143 75 90 100 1 (18) 80 2.03 0.46 11.7 127 189 85 100 115 1/0 (18) 80 2.03 0.50 12.7 152 226 100 120 135 2/0 (18) 80 2.03 0.54 13.7 182 271 115 135 150 3/0 (18) 80 2.03 0.59 15.0 222 330 130 155 175 4/0 (18) 80 2.03 0.64 16.3 271 403 150 180 205 250 (35) 95 2.41 0.71 18.0 328 488 170 205 230 300 (35) 95 2.41 0.76 19.3 385 573 195 230 260 350 (35) 95 2.41 0.81 20.6 435 647 210 250 280 400 (35) 95 2.41 0.85 21.6 494 735 225 270 305 500 (35) 95 2.41 0.93 23.6 600 893 260 310 350 600 (58) 110 2.79 1.07 27.2 721 1073 285 340 385 700 (58) 110 2.79 1.11 28.2 828 1232 315 375 425 750 (58) 110 2.79 1.13 28.7 899 1338 320 385 435 1000 (58) 110 2.79 1.28 32.5 1141 1698 375 445 500 *60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 12 through 1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90ºC RHH dry locations. RHW 2 and USE 2 wet or dry locations. For ampacity derating purposes. Notes: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC Article 310.15, which are based on NEC Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B)(16). NEC Article 240.4(D) requires that over current protection not exceed 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). SELLING INFORMATION Product Features Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Version 4.0 Generated 8/2/18 www.nexans.us Page 50 / 87

ENERGEX 8000 RHH/RHW 2/USE 2 Aluminum Suitable for direct burial Sunlight resistant RoHS compliant Bare conductors are heat treated after stranding for maximum flexibility Version 4.0 Generated 8/2/18 www.nexans.us Page 51 / 87

ENERGEX RHH/RHW 2/USE 2 Copper XLPE Insulated Cable 600 Volts, 90ºC Dry or Wet - LEAD FREE NEC ART 310 and 338 Copper Conductors DESCRIPTION STANDARDS National ICEA S-95-658; UL 854; UL 44 Application Nexans ENERGEX RHH/RHW-2/USE-2 conductors may be installed in raceways and conduits or directly buried. They are 90ºC, 600 volts per NEC Articles 310 and 338. Type USE-2 conductors are suitable as service entrance conductors which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. As type RHW-2 and USE-2, cables are suitable for installation in both wet and dry locations. Nexans RHH/RHW-2/USE-2 conductors are LEAD FREE and RoHS compliant. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-lined polyethylene (XLPE) insulation per UL 854 and UL 44. Black only. Specifications Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A-59544 ICEA 5-95-658 National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger are rated CT use Surface Print Legend (example) NEXANS 1/0 AWG (53.5 mm2) (UL) E64801 F RHW-2 OR USE-2 600V FOR CT USE SR MADE IN CANADA LEAD FREE (MFG DATE). Version V2.0 Generated 8/2/18 www.nexans.us Page 52 / 87

ENERGEX RHH/RHW 2/USE 2 Copper CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V2.0 Generated 8/2/18 www.nexans.us Page 53 / 87

ENERGEX RHH/RHW 2/USE 2 Copper ENERGEX 8000 RHH/RHW 2/USE 2 COPPER 600 V Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 14 (1) 45 1.14 0.16 4.0 21 31 15 15 15 12 (1) 45 1.14 0.17 4.4 30 44 20 20 20 10 (1) 45 1.14 0.19 4.9 44 65 30 30 30 14 (7) 45 1.14 0.16 4.1 21 31 15 15 15 12 (7) 45 1.14 0.18 4.7 30 44 20 20 20 10 (7) 45 1.14 0.21 5.2 44 65 30 30 30 8 (7) 60 1.52 0.27 6.8 70 105 40 50 55 6 (7) 60 1.52 0.31 7.8 104 156 55 65 75 4 (7) 60 1.52 0.35 8.9 157 234 70 85 95 2 (19) 60 1.52 0.41 10.4 240 357 95 115 130 1 (19) 80 2.03 0.49 12.4 309 460 110 130 150 1/0 (19) 80 2.03 0.53 13.4 379 564 125 150 170 2/0 (19) 80 2.03 0.57 14.5 474 706 145 175 195 3/0 (19) 80 2.03 0.61 15.4 583 869 165 200 225 4/0 (19) 80 2.03 0.68 17.2 755 1124 195 230 260 250 (37) 95 2.41 0.74 18.7 867 1291 215 255 290 300 (37) 95 2.41 0.81 20.5 1029 1531 240 285 320 350 (37) 95 2.41 0.86 21.8 1192 1773 260 310 350 400 (37) 95 2.41 0.90 22.9 1352 2012 280 335 380 500 (37) 95 2.41 0.99 25.1 1686 2509 320 380 430 600 (61) 110 2.79 1.09 26.4 2012 2995 355 420 475 700 (61) 110 2.79 1.16 29.5 2332 3470 385 460 520 750 (61) 110 2.79 1.20 30.4 2492 3710 400 475 535 1000 (61) 110 2.79 1.35 34.2 3288 4895 455 545 615 Version V2.0 Generated 8/2/18 www.nexans.us Page 54 / 87

ENERGEX RHH/RHW 2/USE 2 Copper *60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90ºC RHH dry locations. RHW 2 and USE 2 wet or dry locations. For ampacity derating purposes. Notes: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC Article 310.15, which are based on NEC Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B)(16). NEC Article 240.4(D) required that over current protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). SELLING INFORMATION Product Features Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Suitable for direct burial Sunlight resistant LEAD FREE and RoHS compliant. Version V2.0 Generated 8/2/18 www.nexans.us Page 55 / 87

Conduit Wire & Cable Unarmoured Nexans wire and cable is generally installed in conduit or underground duct in dry, damp and wet locations depending on the product construction. All are designed for ease of installation and superior performance. Generated 8/2/18 www.nexans.us Page 56 / 87

ENERGEX 8000 Aluminum XHHW 2 XLPE Insulated Cable, ACM Aluminum Conductors, 600 Volts, 90ºC Dry or Wet - RoHS Compliant DESCRIPTION Application Nexans ENERGEX 8000 XHHW-2 is an AA-8000 series aluminum (ACM) conductor with cross-linked polyethylene insulation. The cable is rated at 600 volts and 90ºC for use in wet and dry locations. XHHW-2 can be used in conduit and other raceways for services, feeders and other applications recognized by the NEC. Sizes 12 AWG to 4/0 AWG are approved as SIS. Nexans XHHW-2 is RoHS compliant. STANDARDS National ICEA S-95-658; UL 44 Construction Conductor: Compact stranded AA-8000 series aluminum alloy (ACM) per ASTM B801 or B836. Insulation: Black, sunlight resistant, cross-linked polyethylene (XLPE) meeting the requirements for XHHW-2 per UL 44. Specifications Nexans ENERGEX 8000 Type XHHW-2 meets or exceeds all applicable ASTM specifications UL 44: Thermoset - Insulated Wires and Cables NEC Article 310.104 Federal Specification A-A-59544 and the requirements of the NEC Meets or exceeds the requirements of NEMA WC 70 / ICEA S-99-658: Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Sunlight resistant in black 8 AWG and larger Sizes 12 AWG to 4/0 AWG rated SIS Voltage rating - 600 Volts Meets IEEE 1202 Surface Print Legend (example) NEXANS-C 1/0 AWG COMPACT AA-8000-AL XHHW-2 600V SR ROHS (UL) (MFG. DATE) Version V5.0 Generated 8/2/18 www.nexans.us Page 57 / 87

ENERGEX 8000 Aluminum XHHW 2 CHARACTERISTICS Construction characteristics Conductor material Aluminum Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V5.0 Generated 8/2/18 www.nexans.us Page 58 / 87

ENERGEX 8000 Aluminum XHHW 2 ENERGEX 8000 XHHW 2 ALUMINUM Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (Amps) mils mm inches mm lb/kft kg/km 60 ºC 75 ºC 90 ºC 6 45 1.14 0.26 6.6 40 59 40 50 55 4 45 1.14 0.31 7.9 57 85 55 65 75 2 45 1.14 0.36 9.1 84 125 75 90 100 1 55 1.40 0.42 10.7 108 161 85 100 115 1/0 55 1.40 0.45 11.4 131 196 100 120 135 2/0 55 1.40 0.49 12.4 161 239 115 135 150 3/0 55 1.40 0.54 13.7 198 294 130 155 175 4/0 55 1.40 0.59 15.0 243 361 150 180 205 250 65 1.65 0.66 16.8 292 434 170 205 230 300 65 1.65 0.71 18.0 352 524 195 230 260 350 65 1.65 0.75 19.1 394 586 210 250 280 400 65 1.65 0.8 20.3 446 663 225 270 305 500 65 1.65 0.87 22.1 548 815 260 310 350 600 80 2.03 0.98 24.9 670 997 285 340 385 700 80 2.03 1.04 26.4 787 1171 315 375 425 750 80 2.03 1.08 27.4 822 1224 320 385 435 900 80 2.03 1.16 29.5 994 1478 355 425 480 *60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 12 AWG through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. Notes: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacity are in accordance with NEC Article 310.15, which are based on NEC Table 310.15(B)(16) for aluminum conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B)(16). NEC Article 240.4(D) required that over current protection not exceed 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). Version V5.0 Generated 8/2/18 www.nexans.us Page 59 / 87

ENERGEX 8000 Aluminum XHHW 2 PACKAGE QUANTITIES AND PART NUMBERS Conductor Size AWG/kcmil Package Quantity / Part Number 500 ft reel 1000 ft reel 5000 ft reel Long Length Cutting Reels 6 677096 677088 677427 680016 4 677153 677146 677435 680018 2 677112 677104 677211 680019 1 677864 677872-677898 1/0 660993 661009-661033 2/0 677179 677161-661777 3/0-680086 - 661322 4/0 677070 677062-661363 250 677591 677583-677906 300 - - - 680053 350 661041 661058-661082 400-680194 - 661348 500 677914 677922-677955 600 - - 661371 661355 750-680732 - 661330 900 - - - 662547 SELLING INFORMATION Product Features Cables are UL listed as Type XHHW-2 Temperature rating of 90ºC dry and wet Sunlight Resistant, black 8 AWG and larger RoHS compliant Bare conductors are heat treated after stranding for maximum flexibility Sizes 12 AWG - 4/0 AWG rated SIS Options Rating for CT use available in conductor sizes 1/0 AWG and larger (4 AWG and larger in green). Version V5.0 Generated 8/2/18 www.nexans.us Page 60 / 87

ENERGEX INSTAGLIDE THHN / THWN 2 / MTW PVC/Nylon Cable, Copper Conductors, 600 Volts, 90 C dry rated - LEAD FREE DESCRIPTION Application Nexans ENERGEX INSTAGLIDE THHN / THWN-2 / MTW is a general purpose wiring product for use in power, lighting and control circuits. It can be used in conduit, ducts and trays for service feeders and branch circuits in industrial and commercial installations. When used in accordance with the NEC, THHN / THWN-2 is suitable for use in wet and dry locations, at conductor temperatures not exceeding 90ºC or for use in oil or coolants at conductor temperatures not exceeding 75ºC. THHN / THWN-2 is gasoline and oil resistant II. When used as Machine Tool Wire (MTW) it is rated at 90ºC in dry locations and 60ºC in wet locations or when exposed to oil or coolants. STANDARDS National CSA C22.2 N 75; ICEA S-95-658; UL 1063; UL 83 Nexans ENERGEX INSTAGLIDE THHN / THWN-2/ MTW wire is RoHS compliant. Nexans INSTAGLIDE reduced friction construction in sizes 6 AWG and larger. Construction Conductor: Solid bare, annealed copper per ASTM B3. Stranded bare annealed copper per ASTM B3 and ASTM B8 Class C compressed for sizes 14 AWG to 2 AWG, and ASTM B8 Class B unilay compressed for sizes 1 AWG and larger. Insulation: Color coded polyvinyl chloride (PVC), heat, moisture and flame retardant compound per UL 83 and UL 1063. Covering: A tough abrasion resistant polyamide (Nylon) covering. Specifications Nexans ENERGEX INSTAGLIDE THHN / THWN-2 or MTW meets or exceeds all applicable ASTM specifications UL 83: Thermoplastic-Insulated Wires and Cables UL 1063: Machine-Tool Wires and Cables (stranded cables only) NEMA WC70 / ICEA S-95-658: Power Cables Rated 2000V or Less for the Distribution of Electrical Energy Federal Specification A-A-59544 and requirements of the NEC CSA C22.2 No. 75: Thermoplastic Insulated Wires and Cables 14 AWG through 750 kcmil are rated VW-1. Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated CT use Black sizes 1/0 AWG and larger are sunlight resistant Rated 600 volts Sizes 8 AWG and larger sequentially marked every 2 feet. Surface Print Legend (example) NEXANS-C INSTAGLIDE 500 kcmil (253mm2) TYPE MTW OR THHN OR THWN-2 GRII SR FOR CT USE VW-1 600V (UL) RoHS (MFG. DATE) Version V6.0 Generated 8/2/18 www.nexans.us Page 61 / 87

ENERGEX INSTAGLIDE THHN / THWN 2 / MTW CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V6.0 Generated 8/2/18 www.nexans.us Page 62 / 87

ENERGEX INSTAGLIDE THHN / THWN 2 / MTW ENERGEX INSTAGLIDE THHN / THWN 2 / MTW COPPER Conductor Size PVC Insulation Thickness Nylon Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (Amps) AWG/kcmil mils mils inches lbs/kft 60ºC 75ºC 90ºC 14 (1) 15 4 0.11 15 15 15 15 12 (1) 15 4 0.12 23 20 20 20 10 (1) 20 4 0.15 37 30 30 30 14 (19) 15 4 0.11 16 15 15 15 12 (19) 15 4 0.13 24 20 20 20 10 (19) 20 4 0.17 39 30 30 30 8 (19) 30 5 0.22 63 40 50 55 6 (19) 30 5 0.26 98 55 65 75 4 (19) 40 6 0.33 157 70 85 95 3 (19) 40 6 0.36 193 85 100 110 2 (19) 40 6 0.39 240 95 115 130 1 (19) 50 7 0.43 300 110 130 150 1/0 (19) 50 7 0.47 376 125 150 170 2/0 (19) 50 7 0.51 467 145 175 195 3/0 (19) 50 7 0.56 581 165 200 225 4/0 (19) 50 7 0.61 724 195 230 260 250 (37) 60 8 0.68 855 215 255 290 300 (37) 60 8 0.73 1022 240 285 320 350 (37) 60 8 0.78 1191 260 310 350 400 (37) 60 8 0.82 1345 280 335 380 500 (37) 60 8 0.90 1668 320 380 430 600 (61) 70 9 0.98 1994 355 420 475 750 (61) 70 9 1.08 2465 400 475 535 *60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. For MTW in wet locations or when exposed to oil or coolant. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. THWN 2 when exposed to oil or coolant. 90 C THHN dry locations. THWN 2 wet or dry locations. For ampacity derating purposes. Available colors: Black, White, Red, Blue, Green, Yellow, Brown, Orange, Purple, Gray, Pink. Notes: Where stated, nominal and approximate values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacities are in accordance with NEC Article 310.15, which are based on NEC Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.15(B)(16). NEC Article 240.4(D) requires that overcurrent protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). Version V6.0 Generated 8/2/18 www.nexans.us Page 63 / 87

ENERGEX INSTAGLIDE THHN / THWN 2 / MTW SELLING INFORMATION Product Features Nexans INSTAGLIDE reduced friction construction in sizes 6 AWG and larger. Sizes 8 AWG to 600 kcmil available in various colors from stock Cables are UL listed as Type THHN / THWN-2/ MTW Meets UL VW-1 flame test requirements Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) are rated CT use Black sizes 1/0 AWG and larger are sunlight resistant Color coded polyvinyl chloride (PVC), heat, moisture and flame retardant insulation system THWN-2 90ºC rated for dry and wet locations Gasoline and Oil Resistant II Small diameter for improved conduit fill RoHS compliant Packaging 14 AWG & 12 AWG: 4 x 500' spools (2000' per carton) or 2500' reel 10 AWG: 2 x 500' spools (1000' per carton) or 2500' reel 8 AWG - 350 kcmil: 500', 1000', 2500' or 5000' reel 400 kcmil - 500 kcmil: 500', 1000', or 2500' reel 600 kcmil - 750 kcmil: 500' reel * Only stranded cables are MTW listed per UL 1063. Version V6.0 Generated 8/2/18 www.nexans.us Page 64 / 87

ENERGEX INSTAGLIDE XHHW 2 Copper XLPE Insulated Cable, Copper Conductors, 600 Volts, 90ºC Dry or Wet - LEAD FREE DESCRIPTION Application Nexans ENERGEX INSTAGLIDE XHHW-2 is a copper conductor, with cross-linked polyethylene insulation. The cable is rated at 600 volts and 90 C for use in wet and dry locations. XHHW-2 can be used in conduit and other raceways for services, feeders and other applications recognized by the NEC. Sizes 14 AWG to 4/0 AWG are approved as Type SIS. Sizes 1/0 AWG and larger (4 AWG and larger in green) in all colors are cable tray (CT) rated. Nexans ENERGEX INSTAGLIDE XHHW-2 conductors are RoHS compliant. Nexans INSTAGLIDE reduced friction construction in sizes 6 AWG and larger. STANDARDS National ICEA S-95-658; UL 44 Construction Conductor: Annealed soft bare copper per ASTM B3, B787 and B8 Insulation: Cross-linked polyethylene (XLPE) insulation per UL 44 Surface Print Legend (example) NEXANS EXELENE 500 kcmil (253 mm2) XHHW-2 (UL) E64801 F 600V FOR CT USE SR - MADE IN CANADA LEAD FREE (MFG. DATE) Specifications Nexans ENERGEX Type XHHW-2 meets or exceeds all applicable ASTM specifications. UL 44: Thermoset-Insulated Wire and Cables Federal Specification A-A-59544 and the requirements of the NEC. NEMA WC70 / ICEA S-95-658: Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy. Conductor sizes 1/0 AWG and larger (4 AWG and larger in green) rated for CT use. Sunlight resistant in black 8 AWG and larger. 14 AWG to 10 AWG are available in 10 distinct colors for identification purposes. Sizes 14 AWG to 4/0 AWG rated SIS. Nexans XHHW-2 is LEAD FREE. Voltage rating - 600 Volts. Version V3.0 Generated 8/2/18 www.nexans.us Page 65 / 87

ENERGEX INSTAGLIDE XHHW 2 Copper CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version V3.0 Generated 8/2/18 www.nexans.us Page 66 / 87

ENERGEX INSTAGLIDE XHHW 2 Copper ENERGEX INSTAGLIDE XHHW 2 COPPER Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 14 (7) 30 0.76 0.130 3.40 18 27 15 15 15 12 (7) 30 0.76 0.150 3.80 26 39 20 20 20 10 (7) 30 0.76 0.170 4.50 40 60 30 30 30 8 (7) 45 1.14 0.240 6.00 64 95 40 50 55 6 (7) 45 1.14 0.270 6.90 97 144 55 65 75 4 (7) 45 1.14 0.320 8.20 149 222 70 85 95 2 (7) 45 1.14 0.380 9.60 230 342 95 115 130 1 (19) 55 1.40 0.430 10.90 288 429 110 130 150 1/0 (19) 55 1.40 0.480 12.10 360 536 125 150 170 2/0 (19) 55 1.40 0.520 13.20 456 679 145 175 195 3/0 (19) 55 1.40 0.560 14.20 563 838 165 200 225 4/0 (19) 55 1.40 0.610 15.60 703 1046 195 230 260 250 (37) 65 1.65 0.680 17.10 837 1245 215 255 290 300 (37) 65 1.65 0.750 18.90 995 1481 240 285 320 350 (37) 65 1.65 0.800 20.20 1155 1719 260 310 350 400 (37) 65 1.65 0.840 21.40 1324 1970 280 335 380 500 (37) 65 1.65 0.930 23.50 1643 2445 320 380 430 600 (61) 80 2.03 1.040 26.30 1986 2955 355 420 475 700 (61) 80 2.03 1.100 27.90 2283 3397 385 460 520 750 (61) 80 2.03 1.140 28.80 2467 3671 400 475 535 1000 (61) 80 2.03 1.290 32.70 3230 4806 455 545 615 *60 C When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 14 through 1 AWG. 75 C When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C Wet or dry locations. For ampacity derating purposes. Notes: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. Ampacity are in accordance with NEC Article 310.15, which are based on NEC Table 310.16 or NEC Table 310.15(B)(16) for conductors in a raceway or direct buried at 30 C ambient temperature. For correction factors for different ambient temperatures and ampacities at different conductor temperature ratings see NEC Table 310.16 or NEC Table 310.15(B)(16). NEC Article 240.4(D) required that over current protection not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper conductors after any correction factors for ambient temperature and number of conductors have been applied. Exceptions to this may be covered in NEC Article 240.4(E) through (G). Version V3.0 Generated 8/2/18 www.nexans.us Page 67 / 87

ENERGEX INSTAGLIDE XHHW 2 Copper SELLING INFORMATION Product Features Sizes 14 AWG to 10 AWG are available in 10 colors: Black, White, Red, Blue, Green, Yellow, Brown, Orange, Gray, Purple. Size 8 AWG and larger in black only. Meets IEEE 1202 Conforms to ICEA S-95-658 Sunlight Resistant 8 AWG and larger in black Conductor sizes 1/0 AWG and larger (4 AWG and larger in green are rated for CT use Sizes 14 AWG to 4/0 AWG rated SIS Meets or exceeds all applicable industry standards LEAD FREE Packaging 14 AWG to 10 AWG 2 x 500 spools (1000 feet) per carton; 2500 reel 8 AWG to 600 kcmil long length 750 kcmil 500 reel or long length Version V3.0 Generated 8/2/18 www.nexans.us Page 68 / 87

Components, Specialty & Bare Copper Cables specially designed for unique installation requirements. Generated 8/2/18 www.nexans.us Page 69 / 87

ENERGEX PV/RHH/RHW 2/USE 2 DESCRIPTION Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. STANDARDS National ICEA S-95-658; UL 854; UL 854 Subject 4703; UL 44 Version 2.0 Generated 8/2/18 www.nexans.us Page 70 / 87

Commercial Building Wire & Cable Aluminum 2 kv Part Number: Solar Cable DESCRIPTION STANDARDS National ICEA S-95-658; UL 854; UL 854 Subject 4703; UL 44 Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Application Nexans ENERGEX PV/RHH/RHW-2/USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 2 kv per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH cables are suitable for installation in dry locations. Type RHW-2 and USE-2 cables are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Compact stranded AA-8000 series aluminum conductor material (ACM) per ASTM B801 Class B or ASTM B836 (Single Input Wire). Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Specifications Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A-59544 National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger are rated CT use UL File Numbers: E338981 (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Surface Print Legend (example) (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) CPT ACM ALUM (UL) USE-2 600V OR RHW-2 OR PV WIRE 2000V 90C WET OR DRY SR DIR BUR LEAD FREE Version 2.0 Generated 8/2/18 www.nexans.us Page 71 / 87

Commercial Building Wire & Cable Aluminum 2 kv CHARACTERISTICS Construction characteristics Conductor material Aluminum Electrical characteristics Maximum operating voltage 2000 V Usage characteristics Maximum operating temperature 90 C Version 2.0 Generated 8/2/18 www.nexans.us Page 72 / 87

Commercial Building Wire & Cable Aluminum 2 kv ENERGEX PV/RHH/RHW 2/USE 2 ALUMINUM 2 KV Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 6 85 2.16 0.34 8.6 57 84 40 50 60 4 85 2.16 0.39 9.9 77 115 55 65 75 2 85 2.16 0.44 11.2 108 160 75 90 100 1 105 2.67 0.51 13.0 142 212 85 100 115 1/0 105 2.67 0.55 14.0 169 251 100 120 135 2/0 105 2.67 0.59 15.0 202 300 115 135 150 3/0 105 2.67 0.64 16.3 240 357 130 155 175 4/0 105 2.67 0.69 17.5 292 434 150 180 205 250 120 3.05 0.76 19.3 354 528 170 205 230 300 120 3.05 0.81 20.6 412 613 190 230 255 350 120 3.05 0.86 21.8 468 697 210 250 280 400 120 3.05 0.90 22.9 525 781 225 270 305 500 120 3.05 0.98 24.9 607 904 260 310 350 600 135 3.43 1.09 27.7 771 1147 285 340 385 750 135 3.43 1.18 30.0 935 1391 320 385 435 1000 135 3.43 1.33 33.8 1214 1806 375 445 500 60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes #6 through #1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than #1 AWG. 90ºC RHH dry locations. PV and RHW 2 wet or dry locations. For ampacity derating purposes. For conductors installed in conduit on a roof top, use the derating factors specified by Table 310.15(B)(3)(c) in the NEC. * Allowable ampacities shown are for general use as specified by the NEC, Section 310.15. SELLING INFORMATION Product Features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 AWG and larger are rated CT use LEAD FREE Options Class C stranding available Version 2.0 Generated 8/2/18 www.nexans.us Page 73 / 87

Commercial Building Wire & Cable Aluminum 600 V Part Number: Solar Cable DESCRIPTION STANDARDS National ICEA S-95-658; UL 854; UL 854 Subject 4703; UL 44 Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Application Nexans ENERGEX PV/RHH/RHW-2/USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 600 V per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH cables are suitable for installation in dry locations. Type RHW-2 and USE-2 cables are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor:Compact stranded AA-8000 series aluminum conductor material (ACM) per ASTM B801 Class B or ASTM B836 (Single Input Wire). Insulation:Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Specifications Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RWH-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A-59544 National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger are rated CT use UL File Numbers: E338981 (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Surface Print Legend (example) (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) CPT ACM ALUM (UL) RHW-2 OR USE-2 OR PV WIRE 600V 90C WET OR DRY SR DIR BUR LEAD FREE Version 2.0 Generated 8/2/18 www.nexans.us Page 74 / 87

Commercial Building Wire & Cable Aluminum 600 V CHARACTERISTICS Construction characteristics Conductor material Aluminum Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 2.0 Generated 8/2/18 www.nexans.us Page 75 / 87

Commercial Building Wire & Cable Aluminum 600 V ENERGEX PV/RHH/RHW 2/USE 2 ALUMINUM 600 V Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 6 75 1.91 0.32 8.2 52 77 40 50 60 4 75 1.91 0.37 9.3 72 107 55 65 75 2 75 1.91 0.42 10.7 102 151 75 90 100 1 95 2.41 0.49 12.5 135 201 85 100 115 1/0 95 2.41 0.53 13.4 161 240 100 120 135 2/0 95 2.41 0.57 14.5 193 288 115 135 150 3/0 95 2.41 0.62 15.6 231 344 130 155 175 4/0 95 2.41 0.67 17.0 282 420 150 180 205 250 110 2.79 0.74 18.9 344 512 170 205 230 300 110 2.79 0.79 20.2 401 596 190 230 255 350 110 2.79 0.84 21.3 456 679 210 250 280 400 110 2.79 0.88 22.4 512 762 225 270 305 500 110 2.79 0.96 24.4 621 925 260 310 350 600 125 3.18 1.07 27.1 755 1124 285 340 385 750 125 3.18 1.16 29.5 918 1367 320 385 435 1000 125 3.18 1.31 33.4 1195 1778 375 445 500 60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes #6 through #1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than #1 AWG. 90ºC RHH dry locations. PV, RHW 2 and USE 2 wet or dry locations. For ampacity derating purposes. For conductors installed in conduit on a roof top, use the derating factors specified by Table 310.15(B)(3)(c) in the NEC. * Allowable ampacities shown are for general use as specified by the NEC, Section 310.15. SELLING INFORMATION Product Features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 and larger are rated CT use LEAD FREE Options Class C stranding available Version 2.0 Generated 8/2/18 www.nexans.us Page 76 / 87

Commercial Building Wire & Cable Copper 2 kv Part Number: Solar Cable DESCRIPTION STANDARDS National ICEA S-95-658; UL 854; UL 854 Subject 4703; UL 44 Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Application Nexans ENERGEX PV/RHH/RHW-2/USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 2 kv per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. When used as type RHH, the cables are suitable for installation in dry locations. Type RHW-2 and USE-2 cables are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Specifications Version 2.0 Generated 8/2/18 www.nexans.us Page 77 / 87

Commercial Building Wire & Cable Copper 2 kv Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A-59544 National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger are rated CT use UL File Numbers: E338981 (PV), E49786 (USE-2), E64801 (RHH, RHW-2 Surface Print Legend (example) (mon/year) NEXANS [plt] 350 kcmil (177.3 mm2) (UL) USE-2 600V OR RHW-2 OR PV WIRE 2000V 90C WET OR DRY SR DIR BUR LEAD FREE CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 2000 V Usage characteristics Maximum operating temperature 90 C Version 2.0 Generated 8/2/18 www.nexans.us Page 78 / 87

Commercial Building Wire & Cable Copper 2 kv ENERGEX PV/RHH/RHW 2/USE 2 COPPER 2 KV Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 8 (7) 85 2.16 0.31 7.9 80 119 40 50 55 6 (7) 85 2.16 0.35 8.8 115 171 55 65 75 4 (7) 85 2.16 0.40 10.0 169 251 70 85 95 2 (7) 85 2.16 0.46 11.5 253 377 95 115 130 1 (19) 105 2.67 0.53 13.3 323 481 110 130 150 1/0 (19) 105 2.67 0.57 14.3 398 592 125 150 170 2/0 (19) 105 2.67 0.61 15.4 489 728 145 175 195 3/0 (19) 105 2.67 0.66 16.6 605 900 165 200 225 4/0 (19) 105 2.67 0.71 18.0 750 1116 195 230 260 250 (37) 120 3.05 0.79 19.9 896 1333 215 255 290 300 (37) 120 3.05 0.84 21.6 1059 1576 240 285 320 350 (37) 120 3.05 0.88 22.4 1220 1816 260 310 350 400 (37) 120 3.05 0.93 23.5 1388 2066 280 335 380 500 (37) 120 3.05 1.10 25.6 1714 2551 320 380 430 600 (61) 135 3.43 1.12 28.2 2064 3072 355 420 475 700 (61) 135 3.43 1.21 29.9 2395 3564 385 460 520 750 (61) 135 3.43 1.24 30.7 2560 3810 400 475 535 1000 (61) 135 3.43 1.39 35.2 3367 5011 455 545 615 60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 8 through 1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90ºC RHH dry locations. PV, RHW 2 and USE 2 wet or dry locations. For ampacity derating purposes. * Allowable ampacities shown are for general use as specified by the NEC, Section 310.15. For conductors installed in conduit on a roof top, use the derating factors specified by Table 310.15(B)(3)(c) in the NEC. Note: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. SELLING INFORMATION Product Features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Suitable for direct burial Sunlight resistant in black and colors Coductors 1/0 AWG and larger are rated CT use LEAD FREE Version 2.0 Generated 8/2/18 www.nexans.us Page 79 / 87

Commercial Building Wire & Cable Copper 2 kv Options Class C stranding available Version 2.0 Generated 8/2/18 www.nexans.us Page 80 / 87

Commercial Building Wire & Cable Copper 600 V Part Number: Solar Cable DESCRIPTION STANDARDS National ICEA S-95-658; UL 854; UL 854 Subject 4703; UL 44 Nexans ENERGEX PV solar cables offer exceptional performance, easy installation and long-term reliability for DC connections. They link photovoltaic panels on rooftops or solar farms, and also connect them to the array box (if one exists), and to the inverter which transforms DC solar energy into usable AC electricity. These cables have a wet and dry temperature rating of 90 C, are UV resistant, flame-retardant, and are certified as UL type PV. Application Nexans ENERGEX PV/RHH/RHW-2/USE-2 cables may be installed indoors or outdoors, in raceways and conduits, or directly buried. They are 90ºC, 600 V or 2 kv per NEC Articles 310 and 338, and suitable for use in a photovoltaic system per NEC Article 690. Type PV cables are for use on the DC side of a photovoltaic system, suitable for installation in both wet and dry locations, and may be exposed to sunlight. Type USE-2 cables are suitable as service entrance cables, which can be installed directly buried in accordance with the NEC. Type RHH cables are suitable for installation in dry locations. Type RHW-2 and USE-2 cables are suitable for installation in both wet and dry locations. Nexans PV/RHH/RHW-2/USE-2 cables are LEAD FREE. Construction Conductor: Stranded annealed soft bare copper conductors per ASTM B8 and B787 Insulation: Heat, sunlight, moisture and abrasion resistant cross-linked polyethylene (XLPE) insulation in black or colors per UL 854 and UL 44 Specifications Version 2.0 Generated 8/2/18 www.nexans.us Page 81 / 87

Commercial Building Wire & Cable Copper 600 V Meets UL Subject 4703 (PV) Photovoltaic Wire Meets UL 44: (RHH, RHW-2) Thermoset Insulated Wires and Cables Meets UL 854 (USE-2) Service Entrance Cables Federal Specification A-A-59544 National Electrical Code - NFPA 70 Conductors 1/0 AWG and larger are rated CT use UL File Numbers: E338981 (PV), E49786 (USE-2), E64801 (RHH, RHW-2) Surface Print Legend (example) (mon/year) NEXANS [plant] 350 kcmil (177.3 mm2) (UL) RHW-2 OR USE-2 OR PV WIRE 600V 90C WET OR DRY SR DIR BUR LEAD FREE CHARACTERISTICS Construction characteristics Conductor material Copper Electrical characteristics Maximum operating voltage 600 V Usage characteristics Maximum operating temperature 90 C Version 2.0 Generated 8/2/18 www.nexans.us Page 82 / 87

Commercial Building Wire & Cable Copper 600 V ENERGEX PV/RHH/RHW 2/USE 2 COPPER 600 V Conductor Size AWG/kcmil Insulation Thickness Nominal Diameter Approximate Net Cable Weight Ampacity* (amps) mils mm inches mm lb/kft kg/km 60ºC 75ºC 90ºC 8 (7) 75 1.91 0.29 7.5 76 113 40 50 55 6 (7) 75 1.91 0.33 8.4 110 164 55 65 75 4 (7) 75 1.91 0.38 9.6 164 244 70 85 95 2 (7) 75 1.91 0.44 11.0 248 369 95 115 130 1 (19) 95 2.41 0.51 12.9 316 470 110 130 150 1/0 (19) 95 2.41 0.55 13.9 390 580 125 150 170 2/0 (19) 95 2.41 0.59 15.0 481 716 145 175 195 3/0 (19) 95 2.41 0.64 16.2 596 887 165 200 225 4/0 (19) 95 2.41 0.69 17.6 740 1101 195 230 260 250 (37) 110 2.79 0.77 19.5 884 1316 215 255 290 300 (37) 110 2.79 0.82 20.8 1048 1560 240 285 320 350 (37) 110 2.79 0.86 22.0 1207 1796 260 310 350 400 (37) 110 2.79 0.91 23.1 1375 2046 280 335 380 500 (37) 110 2.79 0.99 25.1 1700 2530 320 380 430 600 (61) 125 3.18 1.10 27.8 2048 3048 355 420 475 700 (61) 125 3.18 1.19 30.2 2378 3539 385 460 520 750 (61) 125 3.18 1.22 31.0 2542 3783 400 475 535 1000 (61) 125 3.18 1.37 34.8 3347 4981 455 545 615 *60ºC When terminated to equipment for circuits rated 100 amperes or less or marked for conductor sizes 8 through 1 AWG. 75ºC When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90ºC RHH dry locations. PV, RHW 2 and USE 2 wet or dry locations. For ampacity derating purposes. Allowable ampacities shown are for general use as specified by the NEC, Section 310.15. For conductors installed in conduit on a roof top, use the derating factors specified by Table 310.15(B)(3)(c) in the NEC. Note: Where stated, "nominal" and "approximate" values are provided for information purposes only and are subject to standard manufacturing tolerances. SELLING INFORMATION Product Features Cables are UL listed as Type PV Cables are UL listed as Type USE-2 Temperature rating of 90ºC dry and wet Suitable for direct burial Sunlight resistant in black and colors Conductors 1/0 AWG and larger are rated CT use LEAD FREE Version 2.0 Generated 8/2/18 www.nexans.us Page 83 / 87

Commercial Building Wire & Cable Copper 600 V Options Class C stranding available Version 2.0 Generated 8/2/18 www.nexans.us Page 84 / 87

Soft Bare Copper USA* Bare Copper Conductors DESCRIPTION ASTM B-3 Soft or Annealed Copper Wire. ASTM B-3 Specification details the requirements for solid wires and the individual wires in stranded conductors. ASTM B-8 Concentric - Lay - Stranded Copper Conductors Solid or stranded 100% conductivity copper conductors. Application Used for bonding and grounding electrical circuits and systems. STANDARDS CHARACTERISTICS Construction characteristics Conductor material National Factory standard Annealed copper Version V2.0 Generated 8/2/18 www.nexans.us Page 85 / 87

Soft Bare Copper USA* SOFT DRAWN BARE COPPER Size AWG or kcmil Nominal Diameter Approximate Conductor Weight Nominal D.C. Resistance @ 25 C mm in kg/km lbs/kft Ω/km Ω/kft 14 (1) 1.63 0.064 18.5 12.4 8.44 2.570 12 (1) 2.05 0.081 29.4 19.8 5.31 1.620 10 (1) 2.59 0.102 46.8 31.4 3.34 1.020 8 (7) 3.61 0.142 75.9 51.0 2.14 0.653 6 (7) 4.55 0.179 121.0 81.1 1.35 0.411 4 (7) 5.72 0.225 192.0 129.0 0.848 0.258 2 (7) 7.19 0.283 305.0 205.0 0.533 0.163 1 (19) 7.95 0.313 385.0 258.0 0.423 0.129 1/0 (19) 8.94 0.352 485.0 325.0 0.335 0.102 2/0 (19) 10.03 0.395 611.0 410.0 0.266 0.081 3/0 (19) 11.25 0.443 771.0 518.0 0.211 0.064 4/0 (19) 12.65 0.498 972.0 653.0 0.167 0.051 250 (37) 13.77 0.542 1149.0 772.0 0.142 0.043 300 (37) 15.09 0.594 1378.0 926.0 0.118 0.036 350 (37) 16.28 0.641 1609.0 1081.0 0.101 0.031 400 (37) 17.40 0.685 1838.0 1235.0 0.088 0.027 500 (37) 19.46 0.766 2298.0 1544.0 0.071 0.021 600 (61) 21.34 0.840 2758.0 1853.0 0.059 0.018 750 (61) 23.85 0.939 3447.0 2316.0 0.047 0.014 1000 (61) 28.37 1.117 4595.0 3088.0 0.035 0.011 * ASTM B-3 Specification details the requirements for solid wires and the individual wires in stranded conductors. Version V2.0 Generated 8/2/18 www.nexans.us Page 86 / 87

Nexans US - United States globalsalessupport.us@nexans.com Distributed by