Navigator 550 Sodium wet-section

Similar documents
Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

ABB MEASUREMENT & ANALYTICS DATA SHEET series ph and Redox (ORP) industrial dip electrode systems

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

Measurement Products. WaterMaster electromagnetic flowmeter The perfect fit for all water industry applications

Shut-off valves and accessories for pressure measuring instruments

R Series Electromagnetic flowmeter Reduced-bore flow sensors. The smart solution for remote applications

The perfect solution for wellhead flow measurement with CoriolisMaster, ProcessMaster and VortexMaster

Gas analyzers EL3060 The specialists for hazardous areas

FPD201 Single-chamber orifice fitting

EAS822 (Contrac) Power Electronic Unit

Service Flow products

ZMT & ZFG2 Zirconia Oxygen Analyzer Systems. Superior technology and quality from the world leader in oxygen measurement

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

Moving Coil Indicators with direct temperature sensor input

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual

Electromagnetic Flowmeters

Katharometer Power Supply Units

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

Additional Information. Measurement made easy

RSD100 (Contrac) Electrical Linear Actuator

FLEXIBLE PENDANTS with Axis MEDICAL GAS TERMINAL UNITS

2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment

MB3600-HP10 Laboratory FT-NIR analyzer for hydrocarbon applications Pre-calibrated for blended gasoline, diesel, reformate and naphtha

Technical Description. Wireless Automation Accessories

Additional Information. Measurement made easy

1260 Infinity II Degasser User Manual. 5 Maintenance

AquaMaster3 Electromagnetic flowmeter

ABB measurement & analytics data sheet. Model M26 Manifold line for 266 pressure transmitters

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

MKIV Universal Hopper Service Manual TSP053.doc Issue 2.1 June 2004

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. Electronic unit and accessories Retrofitting on Contrac

Product Brochure. E-Z Kleen and Ultra Kleen ball bearings

AP200 series Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

ABB cable glands SCG series Stainless Steel 316L, general purpose cable glands

Safety interlock switch MKey

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell

Surge arrester POLIM-H..SD

Control Valve 23 / 24 Single-seat straight-way valve with exchangeable seat ring

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

ABB measurement products HEC Eastern Sunshine Fluorine Shaoguang China

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Insulated crimp terminals For reliable device connection

FPD220 meter 2 di Dual-chamber orifice fitting with double isolation

FICHA TÉCNICA DE PRODUTO

Safety stop buttons Smile, INCA and Compact

Analytical Instruments Two-Electrode Conductivity Sensors

Valve Blocks. For direct flanging to pressure and differential pressure transmitters. Drop-forging housing. Replaceable valve seat

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Voltage limiting device HVL

RS85 Vibrating fork level switch

CV Master Cylinders. Publication CB 006. Typical Assembly

FICHA TÉCNICA DE PRODUTO

Voltage limiting device HVL

Marine motors Additional manual for open deck marine motors Cast iron motors IEC

Axis MEDICAL GAS TERMINAL UNITS

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

N) manual. Register your instrument! Eppendorf Research plus. Operating manual

Installing an H-200 Integral Right-Angle Module

Sieve Shaker 200mm/300mm - 8/12 inch SV003

C15C C15C. Page 1 of 20

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Fitting Instructions: Street Triple from VIN and Street Triple R from VIN A

Mini contactors B6, BC6 with 3 pole

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Accessory Kit Estimated Fitting Time: 120 Minutes (Prado) Estimated Fitting Time: 140 Minutes (Kluger)

Surge arrester POLIM-C.. HD

Fitting Instructions

3 PORT MOTORISED VALVE (22 mm)

TRANSFORMER SERVICE. ABB Ability inspection for transformers TXplore Oil-filled transformer internal inspection service

LV Capacitors QCap-L series Capacitors for power factor correction

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

MW05 MagWave Magnetic Level Gauge. Dual chamber level system K-TEK Products

MEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

Relay Retrofit Program for REX 521 Cutting Tool Safety Guide

Combination ph/redox (ORP) Sensors

Features. Marathon SL TECHNICAL CHARACTERISTICS. Sliding bushes: made of friction free and wear free material.

Models NAA, NAB, NAD Pneumatic differential pressure transmitters. Deltapi N Series A complete range of pneumatic pressure transmitters

Control Valve From high-temperature/ high-pressure plant to process plant

Unit C of the Scholven Power Plant Automated with System 800xA

Series 100 Slam Shut Valve

2 PORT MOTORISED VALVE (28 mm)

HG 20F-012E-01 OIL CONTROL GUN

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Instruction Manual. E1M40, E1M80, E2M40 and E2M80 E2M40S and E2M80S Rotary Vacuum Pumps. Item Number

PNEUMATIC PUMP Series

Operating instructions ErgoPack 600 E

250L Cartridge Dual Seal

EMPAC Metal enclosed capacitor bank for wind applications

ZP2.5-PE Spring Terminal Block Ground

Transcription:

ABB MEASUREMENT & ANALYTICS INFORMATION INF13/115-EN REV. B Navigator 550 Sodium wet-section Spares replacement procedures Measurement made easy Navigator 550 sodium wet-section 1 Introduction These procedures must be carried out by a trained technician. 2 For more information Further information is available from: www.abb.com/analytical Tools required Pozidrive screwdriver Slot-head terminal screwdriver Anti-static strap. or by scanning these codes: Sales Service

3 Safety 3 Safety 4 Replacement procedures Warning. These procedures must be carried out by a trained technician. CHEMICAL Ensure personal protective equipment (PPE) such as gloves and eye protection are worn during any maintenance. Observe all health and safety procedures for handling chemicals. To familiarize yourself with handling precautions, dangers and emergency procedures, always review the Material Safety Data Sheets prior to handling containers, reservoirs and delivery systems that contain chemical reagents and standards. Take care if cleaning any spillages and observe all relevant safety instructions. Wipe up any spillages using clean water. Perform general cleaning of the wet-section using a damp cloth only mild detergent can be used as a cleaning aid. Do not use Acetone or any organic solvents. ELECTRICAL Isolate all high voltage supplies to the transmitter before performing replacement procedures. The wet-section is vulnerable to electrostatic damage. Wear an anti-static strap or dismantle the wet-section on an anti-static workbench. Ensure all electrical connections are kept dry at all times. Modbus cable assembly see Section 4.5, page 5 PCB housing seals, PCB cover and PCB see Section 4.1, page 3 Constant-head assembly, pressure switch assembly and pressure switch cable see Section 4.3, page 4 Solenoid valve assembly and solenoid valve cable(s) see Section 4.4, page 4 Flowmeter assembly and flowmeter cable(s) see Section 4.2, page 3 Fig. 4.1 Sodium wet-section replacement procedures GENERAL Shut off the external sample supply to the wet-section before performing replacement procedures. When a procedure is complete, restore power to the transmitter, sample to the wet-section at the correct flow rate and, if necessary, calibrate the wet-section refer to the wet-section Operating Instructions (OI/ASO550-EN) for calibration instructions. Dispose of the old components in accordance with the guidelines contained in the Operating instructions (OI/ASO550-EN). 2 INF13/115 EN Rev. B Navigator 550 Sodium wet-section Spares replacement procedures

4 Replacement procedures 4.1 Replacing the PCB housing seals, PCB cover and PCB Part numbers: PCB housing seals: AW501 051 PCB cover: AW501 052 PCB: AW501 050 Referring to Fig. 4.2: 1. Remove and retain the 4 PCB cover fixing screws and washers A and remove the PCB cover B. 2. If replacing PCB housing seals, remove and discard housing seal C. 3. Disconnect all cables from the PCB D, loosen all cable glands and remove cables. 4. Remove and retain the 4 PCB housing fixing screws and washers E and remove the PCB housing F. 5. If replacing PCB housing seals, lift PCB housing seal G out of the groove and discard. 6. Remove and retain the 2 PCB fixing screws and washers H and remove the PCB D. If replacing PCB housing seals, fit the new (large) PCB housing seal G in the groove (a small amount of silicone sealant or grease can be used to help retain the seal in place). 7. Fit the new PCB to the rear of the main case using the 2 PCB retaining screws and washers H. 8. Refit the PCB housing E using the 4 PCB housing fixing screws and washers D. Referring to Fig. 4.3 and Table 4.1 for terminal connection details: 9. Make cable connections at the new PCB. Referring to Fig. 4.2: 10. If replacing PCB housing seals, fit the new (small) PCB housing seal C between the PCB cover B and PCB housing F (a small amount of silicone sealant or grease can be used to help retain the seal in place). 11. Refit the PCB cover B using the 4 PCB cover fixing screws and washers A, ensuring PCB housing seal C is located correctly in its groove. Fig. 4.2 Replacing the PCB housing seals, PCB cover and PCB Additional daisy -chain cable connections 1 B R SC R G W 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 2 3 4 5 6 8 7 Entry Cable Color Terminal Description R 24 V B 0 V G Data +ve W Data ve SCR Screen 1 Serial (Modbus) refer to Operating Instructions Green (OI/ASO550-EN) White for multiple wet-section setup Screen 2 Sodium electrode Screen Core 3 Pt1000 temperature sensor Blue 34 N/A 36 33 N/A 35 4 Reference electrode 32 N/A 5 Pressure switch Green Brown 6 Calibration valve Yellow Orange Stream switch valve single-stream Green 7 Brown Stream switch valve multi-stream Yellow Orange Flowmeter stream 1 Brown 8 Orange Flowmeter stream 2 Yellow (multi-stream) Green Blue Flowmeter stream 3 Violet (multi-stream) Grey Table 4.1 Wet-section cable terminal connections 25 26 7 8 9 10 11 12 1 2 1 2 3 4 5 6 13 15 17 20 22 24 19 21 23 N/A N/A Valve 1 +ve Valve 1 ve Valve 2 +ve Valve 2 ve Regen. +ve Regen. ve Valve 1 +ve Valve 1 ve Valve 1 +ve Valve 1 ve Valve 2 +ve Valve 2 ve Valve 3 +ve Valve 3 ve +ve GND ve +ve GND ve +ve GND ve 4.2 Replacing the flowmeter assembly and flowmeter cable(s) Part numbers: Flowmeter: AW501 068 Single-stream cable: AW501 086 Multi-stream cable: AW501 087 Referring to Fig. 4.4: 1. Disconnect the flowmeter cable A from the flowmeter B and remove the sample inlet tubing C from the flowmeter inlet spigot D. If replacing cable(s), refer to Section 4.1 for cable disconnection details and remove / discard the cable(s). 2. Disconnect the flowmeter B from the QD connector E by pressing the ring and pulling the flowmeter away. 3. Fit new flowmeter(s) / cable(s) in the reverse order of removal ensure the correct cable type (multi-stream or single-stream) is connected at each flowmeter. Fig. 4.3 Wet section PCB cable entries see Table 3.1 for connections Fig. 4.4 Replacing the flowmeter assembly and flowmeter cable(s) Navigator 550 Sodium wet-section Spares replacement procedures INF13/115 EN Rev. B 3

4 Replacement procedures 4.3 Replacing the constant-head assembly, pressure switch assembly and pressure switch cable Part numbers: Constant-head assembly: AW501 061 Pressure switch assembly: AW501 062 Pressure switch cable: AW501 085 Referring to Fig. 4.5: 1. Remove all tubing A to the constant-head assembly. 2. Carefully disconnect the 2 spade connectors B at the rear of pressure switch C. If replacing the cable, refer to Section 4.1, page 3, for cable connection details and remove / discard the cable. 3. Unscrew the 2 securing screws D on the upper faces of the constant head body support arms E and remove the constant-head assembly, complete with pressure switch. 4. If replacing the pressure switch, unscrew the 4 retaining screws F (note that the nuts G are constrained in the support bracket and may fall out when screws are removed). 5. Fit a replacement pressure switch and new O-ring H in the reverse order of removal note the orientation (LOW) is always uppermost. 6. If replacing the cable, fit in the reverse order of removal and connect the 2 spade connectors B to the rear of the pressure switch, otherwise re-connect the existing spade connectors. 7. Secure the constant-head assembly complete with pressure switch, in the reverse order of removal. 4.4 Replacing the solenoid valve assembly and solenoid valve cable(s) Part numbers: Sodium multi-stream solenoid valve: AW501 053 Cable for multi-stream solenoid valve: AW501 081 Sodium single-stream solenoid valve: AW501 077 Cable for single-stream solenoid valve: AW501 080 Cable for calibration and reagent solenoid valve: AW501 082 Note. Valve port configuration: on the single-stream solenoid valve only (part number AW501 077), the N/C port is closest to the electrical connector. Referring to Fig. 4.6: 1. Remove all tubing connected to the valves A. 2. Unclip the valve cable connectors B from the underside of each solenoid valve body. If replacing cable(s), refer to Section 4.1 for cable connection details and remove / discard the cables. 3. Unscrew the 2 retaining screws C that hold plate D to bracket E and withdraw the valves complete with plate D. 4. For each valve, unscrew the 2 valve securing screws and nuts F and remove the valve. 5. Ensure the valve cable connector for each valve is facing downwards and fit each new valve assembly to the plate D using the 2 valve securing screws and nuts F refer to Note. above for single-stream valve port configuration. 6. Refit plate D to the bracket E using the 2 retaining screws C. 7. If replacing cable(s), fit in the reverse order of removal and re-clip cable connector(s) B to the underside of each new valve body. Ensure the correct cable type is connected at each solenoid valve. 8. Reconnect all tubing to the new valves. Calibration and reagent stream switching solenoid valves Single- and multistream solenoid valve(s) IN/OUT Fig. 4.5 Replacing the constant-head assembly, pressure switch assembly and pressure switch cable Fig. 4.6 Replacing the solenoid valve assembly and solenoid valve cables (multi-stream version shown) 4 INF13/115 EN Rev. B Navigator 550 Sodium wet-section Spares replacement procedures

4 Replacement procedures 4.5 Replacing the Modbus cable assembly Modbus cable part numbers: AW501 090 / 1.5 m (4.9 ft.) AW501 091 / 5 m (16.4 ft.) AW501 092 / 10 m (32.8 ft.) AW501 093 / 20 m (65.6 ft.) Referring to Section 4.2, page 3: 1. Remove the wet-section PCB cover. Referring to Fig. 4.7: 2. Loosen cable gland A at the wet-section PCB housing B and disconnect the Modbus cable D from the terminal block connections C marked black, red, screen, green and white. 3. Withdraw the Modbus cable D from the PCB housing and main case assembly and discard. 4. Feed the replacement Modbus cable into the main case via the guide channel E at the top, feed through the gland and remake connections to the black, red, screen, green and white PCB wet-section terminals and at the transmitter. 5. Refit the PCB cover by reversing the removal procedure. B R SCR G W Fig. 4.7 Replacing the Modbus cable assembly Navigator 550 Sodium wet-section Spares replacement procedures INF13/115 EN Rev. B 5

Notes Notes 6 INF13/115 EN Rev. B Navigator 550 Sodium wet-section Spares replacement procedures

Notes Navigator 550 Sodium wet-section Spares replacement procedures INF13/115 EN Rev. B 7

ABB Limited Measurement & Analytics Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671 Email: instrumentation@gb.abb.com ABB Inc. Measurement & Analytics 125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 abb.com/measurement We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. ABB 2018 INF13/115-EN Rev. B 10.2018