Dawson DAN100. Analog Multimeter User s Manual

Similar documents
Dawson DDM190D. Digital Multimeter User s Manual

Dawson DSM170 Multi-Function Moisture Meter User s Manual

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Digital Multimeter User's Manual

A.W. SPERRY INSTRUMENTS INC.

Table of Contents Title Page No.

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL DM5B Fax: (503)

5.2 PRE-OPERATION PROCEDURE WARRANTY

Mini Multimeter with Non-Contact Voltage Detector (NCV)

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

362 Clamp Meter. Users Manual

INSTRUCTION MANUAL M110A Fax: (503)

OPERATING INSTRUCTION

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

OPERATING INSTRUCTIONS

Go to to register your product and find more information.

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Phase Sequence Tester

True RMS Autoranging Multimeter

Autoranging Industrial Multimeter

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

365 Detachable Jaw True-rms Clamp Meter

Autoranging Multimeter

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

TRIPLETT. Model 310 Type C Type 9. Test Equipment Depot Washington Street, Melrose, MA TestEquipmentDepot.

362 Clamp Meter. Users Manual

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

i400s Calibration Information Introduction

Model Battery Powered Milliohm Meter

233 True-rms Remote Display Digital Multimeter Safety Information

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

323/324/325 Clamp Meter

User's Guide. True RMS Multim eter. Extech 430

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

Digital Multimeter AHMAD FOUAD ALWAN

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

OPERATING INSTRUCTIONS

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

373 Clamp Meter. Users Manual

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

INSTRUCTION MANUAL DM383B Fax: (503)

Model UT601: OPERATING MANUAL

Users Manual. Phase Rotation Indicator

OPERATING INSTRUCTION

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

TRIPLETT. Model 310 Type C Type 9

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

ATD-5570 Deluxe Automotive Meter with RPM and Temperature Functions Owner s Manual Features:

i3000s/i2000 Flex AC Current Probe

USER MANUAL. Insulation Tester + DMM. Model MG320

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

Model UT602/603: OPERATING MANUAL

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER

DC REGULATED POWER SUPPLY

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

DIGITAL RCD(ELCB) TESTER

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

ATD-5540 Digital Automotive Engine Analyzer/Multimeter Owner s Manual

707Ex. Users Manual. ma Calibrator

Visit us at

Digital/Analog Megohmmeter Model 1026 USER MANUAL

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

KMP Insulation-Continuity Tester. Users Manual

Temperature Calibrator

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

Digital/Analog Megohmmeter Model 1026

Users Manual. MegOhmMeter

302+/303 Clamp Meter. Users Manual

User Guide. Model Insulation Tester / Megohmmeter

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

Low Amp Probe EETA308A

Switching DC Power Supply

User Guide. Model Insulation Tester / Megohmmeter


TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

INSP-3 Wiring Inspection Tester

3-1/2 Digit LCD Multimeter with Tachometer Kit

User's Manual. Earth Ground Resistance Tester. Model Introduction

OPERATING INSTRUCTIONS

4-20mA DC PROCESS CLAMP METER

Transcription:

Dawson DAN100 Analog Multimeter User s Manual

TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the BoxError! Bookmark not defined. Accessories... 4 Safety Information... 6 Certification... 6 INTRODUCTION... 7 Overview... 7 Figures and Components... 7 USING THE METER... 8 Preparation... 8 Reading the Scale... 9 DC/AC Voltage Measurement... 10 Common AC Voltage Measurements... 11 DC Current Measurement (ma)... 12 Common DC ma Measurements... 13 Resistance/Continuity Measurement... 14 Extension Cords Continuity Test... 15 1

Fuses Test... 16 Switches... 16 Transistor Gain Measurement... 17 SPECIFICATIONS... 18 General Specification... 18 MAINTENANCE AND REPAIR... 19 Repair... 19 Replace Batteries... 19 Replace Fuse... 20 CONTACT DAWSON... 20 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY This instrument from Dawson Tools Inc. will be free from defects in workmanship and material for three years from the date of original purchase. This warranty does not cover defects resulting from damage caused by the user such as drops, neglect, misuse, unauthorized alteration, usage outside of specified conditions, contamination, or improper repair/maintenance. To receive service on the instrument if it becomes necessary during the warranty period, contact your nearest Dawson authorized service center at (800) 898-6991 or visit www.dawsontools.com to obtain a return authorization (within the US only). A return authorization is necessary before returning any instrument to Dawson; no service will be provided without a return authorization. The user is responsible for properly packing the unit and charges such as shipping, freight and insurance charges. The extent of Dawson's liability is limited solely to the repair/replacement of the instrument. The above warranty in its entirety is inclusive and no other warranties, written or oral, are expressed or implied. Out of the Box Check the Meter and accessories thoroughly before using the Meter. Contact your local distributor if the Meter or any components are damaged or malfunction. 3

Accessories Test Leads 1 pair 1.5V AA Battery 1pc Safety Information WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, PRODUCT DAMAGE OR PERSONAL INJURY, PLEASE FOLLOW THE SAFETY INSTRUCTIONS DESCRIBED IN THE USER MANUAL. READ THE USER MANUAL BEFORE USING THE METER. WARNING TO ENSURE SAFE OPERATION AND LIFE OF THE METER, DO NOT PLACE THE METER IN ANY ENVIRONMENT WITH HIGH PRESSURE, HIGH TEMPERATURE, DUST, EXPLOSIVE GAS OR VAPOR. 4 Avoid shaking, dropping or any kind of impacts when using or transporting the Meter. To avoid electric shock or personal injury, repairs or servicing not covered in this manual

should be performed only by qualified personnel. Avoid direct exposure to sunlight to ensure extended life of the Meter. Do not place Meter in a strong magnetic field; this may cause false readings. Use only the batteries indicated in the Technical Spec. Avoid exposing batteries to humidity. Replace batteries as soon as the low battery indicator appears. Please keep the original packing for future shipping purposes (ex. Calibration) After opening the box, check for any damage during delivery. Safety Symbols on the Meter Important safety information, please refers to the user manual Earth ground Indicates compliance with requirements for double insulation 5

Important Safety Information Never use the Meter to measure voltages that might exceed 300V DC/AC above earth ground. Always be careful when working with voltages above 60V DC or 30V AC RMS. Keep fingers behind the probe barriers while measuring. Never connect the Meter leads across a voltage source while the rotary switch is in resistance, diode or continuity modes. Doing so can damage the Meter. Inspect test leads and probes for cracks, breaks or crazes on the insulation before using the Meter. Repair or maintenance should be implemented by trained personnel only. Certification CAT II: This meter has meet IEC1010-1 standard with an overvoltage category (300V CAT II) and pollution degree 2. The Meter is compiled to EMC requirements. 6

Introduction Overview The DAN100 is a compact analog multimeter featuring a large analog scale. Functions include AC/DC voltage, AC/DC current and resistance measurements. This DAN100 meter is ideal for both professionals and hobbyists. Figures and Components Front Panel 7

Using the Meter Preparation Fully plug the test leads into the input jacks. Red lead to VΩA+ input and black lead to COM- input. Calibration of the scale is needed before making measurements. Use a small size flat tip screwdriver to adjust the black knob located in the center of the Meter, next to the Dawson logo. The needle on the scale should align with 0 on the left side of the scale. The symbol next to the input lead shows that the input voltage or current should not exceed the specified value in order to protect the internal circuit from damage. Turn the rotary switch to the required function and range to be measured. Choose the highest range when the value to be measured is unknown. When making connections, connect the common test lead first and then the powered test lead. 8

Remove the charged test lead first when disconnecting. Reading the Scale General Make sure to align the needle with the scale. Resistance (Ohms - Ω) Use the top scale (Green) to read resistance. The meter is set to X1k; multiply the resistance value by 1000Ω. 9

DC Voltage (V DC) Use the middle scale (Black). To read of the measurement, first match the dial range setting to the highest number on the scale to find out the according scale. AC Voltage (V AC) Use the same numbers and procedures used for DC voltage measurement. DC Current (ma) Use the same scale (Black) and procedures as used for the DC voltage setting. Decibel Gain (db) Use the scale marked db to read decibels for transistor gain. Use the chart at the right of the scale for proper conversion. DC/AC Voltage Measurement Plug the test leads into the input jacks. Use rotary switch to select DCV or ACV and the proper range (0~10V, 0~50V, 0~150V or 0~300V). 10

Choose the highest range when the value to be measured is unknown. Connect the test leads to the circuit in series, that is, to let the current of the circuit to pass the Meter through test leads. If the needle deflects to the left, reverse the leads connection. Read of the scale as described in Reading the Scale. NOTE: For the 0.5mA range, use the 0-50 scale and then multiply by 0.01 (ma) Common AC Voltage Measurements Wall Receptacles If the receptacle is controlled by a switch, make sure the switch is ON. Set the rotary switch to 150 ACV. Touch the red test lead to the hot and black to the neutral slots of the receptacle (see fig. 3A). The needle indicator should read 120V AC on the 0-150 scale. To test for proper grounding of the receptacle, touch the red test lead to the hot (narrow) side of the receptacle, and the black test lead to the ground slot. The meter should read 120V AC as before. 11

DC Current Measurement (ma) WARNING DO NOT APPLY VOLTAGE TEST WHEN ROTARY SWITCH IS IN CURRENT MODE Plug the test leads into the input jacks. Use rotary switch to select proper range: 0.5, 50 or 150 DCmA. Choose the highest range when the value to be measured is unknown. Connect the test lead to the target, red to positive and black to negative terminals. Read of the scale as described in Reading the Scale. NOTE: For 0.5mA range, use the 0-50 scale and multiply by 0.01mA 12

Common DC ma Current Measurements WARNING DO NOT APPLY VOLTAGE TEST WHEN ROTARY SWITCH IS IN CURRENT MODE It is important to point out that milliamps can also be expressed as thousandths of an Ampere; therefore 150 milliamps is 150 thousandths of one Amp. The 150mA function of your multimeter is commonly used by electronics repair technicians and hobbyists to troubleshoot various low voltage circuits. Although not normally used for electrical troubleshooting around house, this function can be used to measure the milliamperage draw of household items such as flashlights and other battery operated devices that do not draw more than 150 ma. In fig. 2 the red (+) test lead is hooked up to the (+) terminal of the lantern battery while the black (-) test lead is hooked up to the bulb. The meter will indicate the milli-amperage draw when the flashlight switch is thrown in the ON position. 13

Resistance/Continuity Measurement WARNING DO NOT APPLY VOLTAGE OR CURRENT TEST WHEN ROTARY SWITCH IS IN RESISTANCE MODE WARNING POWER OFF THE CIRCUIT Plug the test leads into the input jacks. Rotate the switch to Ohm x1k mode. Connect the test lead to the target, polarity is not a concern. For Resistance read the scale (Green) as described in Reading the Scale. For Continuity test, if the circuit is well connected, the needle should move all the way to the right side of the ohms scale (Green), indicating 0 ohms. 14

NOTE: When switching between resistance mode and other modes, always calibrate the needle to zero before making measurement. Extension Cords Continuity Test Unplug the cord from two sides. Set the rotary switch to the ohm x1k position. Touch one of the test leads to one of the metal prong ends of the cord, insert the other test lead in either one of the receptacle slots on the other end of the cord. Make sure the test lead is making contact with the slot. Test both slots with the test lead, making sure in both cases that the leads are well connected to the slot. If none of the tests appear to have 0 ohm resistance, the continuity test fails. Fig.4 15

Fuses Test Remove the fuse from the appliance. Touch each end of fuse (fig.5) with the test leads and perform the continuity test. For plug type fuses, touch the test leads at the bottom and the threaded metal contact (fig.6). Switches Remove the switch from any power source. Turn the switch to ON position and touch the test leads to the switch terminals (fig. 7). If the switch is good, the needle indictor will move to ~0 ohm. On other switches such as three-way light switches or double pole double throw (ON-OFF-ON) switches, each ON position will need to be tested. Alternate the test leads between the switch terminals to determine which two terminals control the ON position. 16

Transistor Gain Measurement (db) To measure the gain of a transistor: Plug the test leads into the input jacks. Set the rotary switch to any one of the AC voltage ranges and read the decibel measurement on the bottom (red) scale. Compute the actual decibel conversion based on the chart located at the bottom right of the faceplate. NOTE: Circuit impedance must be at least 600 ohms. 0 decibels = 1 milliwatt. 17

Specifications General Specification Ranges: 12 measuring ranges DC Voltage: 10,50,150,300 Volts AC Voltage: 0.5,50,150mA DC Current (ma): 0.5,50,150mA Resistance : R x1k (resistance indicated multiplied by 1000) ohm AC voltage range:-20db to +52dB Accuracy: DC voltage, ma = ±4% full scale of range AC voltage = ±5 % full scale of range Resistance = ±4% arc of scale length ±4 Operating altitude: max. 2000 meters (7000 ft.) Display: Analog display Fuse: F200mA/250V Φ 5.2x20mm Power Supply : 1.5V 1 AA batteries Test Lead: CE CATII 300V 1A Operating Temperature: 18 C to 25 C (64 F to 77 F) Dimension: 93 62 32mm (3.6x2.4x1.3 in.) Weight: approximate 117g (4.1oz) including batteries 18

Maintenance and Repair Repair Please follow the steps closely if the Meter is not functioning properly: Check batteries; replace if necessary Follow User s Manual to confirm all procedures. Before sending Meter back for repair, include a description of the problems encountered. Remove batteries and pack Meter well to avoid damage in delivery, Dawson does not cover damage due to delivery. Repair or service not covered in this manual should be performed only by the authorized service center or qualified personnel. Replacing Batteries Follow these steps to replace batteries: Turn off the Meter. Loosen the back cover and remove from case. Remove batteries and replace with new batteries. Re-attach back cover and tighten screw. 19

Replacing Fuse Fuses rarely need replacement. Almost all blows are the result of operation error. Loosen the back cover like in the Replacing Batteries. Replace the blown fuse with one at the specified rating (F200mA 250V). Re-attach back cover and tighten screw. Contact Dawson Dawson Tools, Inc. 1142 S. Diamond Bar Blvd., #858 Diamond Bar, CA 91765 Phone: (310) 728-6220 www.dawsontools,com Do not recycle 20