Drilling Series SC Series Cellular Suction Stabilizers Instruction, Operating & Maintenance Manual

Similar documents
DR Series Reactive Discharge Dampeners For Drilling

SERIES PC INSTRUCTION AND OPERATION MANUAL

Full View Flow Indicator

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC.

Installation, Operation, and Maintenance Manual

1/2" AIR DRIVEN DIAPHRAGM PUMP

IMPORTANT SAFETY NOTICE

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Installation Operation Maintenance ADDENDUM

Installation and Maintenance Manual CEMLINE CORPORATION

Wet pipe low flow foam/water manifold system

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

Page 1 of 26 Oteco Inc. Houston, Texas

Pressure Relief Valve Maintenance Manual

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

HUNTER PUMPS ELECTRIC FIRE PUMP SET

GL Ludemann Y-Strainers

Polypropylene Piston Drum Pumps

Geo-Prime Tank U.S. Patent Number 8,544,282

FU01 Tank Assembly. Copyright 1998 Inter-Industry Conference On Auto Collision Repair v.4.0

Val-Matic 4-20 Air/Vacuum Valve

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

Fisher TBX Hydro Plug Fixture

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Fisher CVX Hydro Plug Fixture

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Fisher 249 Caged Displacer Sensors

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

SERIES G3DB/AG3DB ELEVATOR

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

Geo-Prime Tank. Table of Contents. Installation, Operation & Maintenance Instructions AFCG1PT Revision: 7/3/14. Replacing a Pump 12

Operation & Maintenance Manual For 4900 Series Pumps Bulletin 134

Industrial Pro FH239 Series Filter/Separator/Warmer Installation Instructions

Installation and Maintenance Manual CEMLINE CORPORATION

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

Triton. Wet Barrel Ductile Iron. Fire Hydrants. Reliable Connections. operation / Maintenance manual. Inspection and Installation 2

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Winslow Liquid Fuel Filters Standard Design Type 2 Service Instructions

Model GP5128HS. Hydraulic Drive Pump. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Model GP5128. Triplex Ceramic Plunger Pump Operating Instructions / Manual

Operation & Maintenance Manual 4900 Series Pipeline Injection Pumps Bulletin 150

AOYUE INT. Advanced Repairing System NT 701A++ INSTRUCTION MANUAL

660R-RAC Series. Gasoline Fuel Filter/Water Separators. Overview: Contact Information: Product Features: Instruction Part Number Rev F

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Northern Pump A Division of McNally Industries, LLC

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE

OPERATING AND MAINTENANCE MANUAL

P239-1 Supply Pumper Instructions

SAFETY MANUAL READ FIRST!

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Model GX Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

KP-C Series. Close Coupled End Suction Centrifugal Pumps. Installation, Operation and Maintenance

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Sea Pro FH240 Series Filter/Separator Installation Instructions

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

Medium and high pressure pumps

Top Drive System Installation and Commissioning Manual

3M TM Filter Housing 1BS-T/1BS-TW Series

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

Model CP470. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Crispin Valves Operating Guide. Crispin

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Fisher 1B and 1BR Constant Pressure Pump Governor Actuators

Operating & Maintenance Manual For Steam Conditioning Valve

SELF PRIMING CHEMICAL SERVICE PUMPS

Venturi Flow Meter Installation and Operation Manual

Operation and Maintenance Manual Magnetic Drive Sealless Pumps MAXP SERIES

PARTS AND INSTALLATION MANUAL

Type 644 and 645 Differential Pressure Pump Governors

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Models & Inch & 4 Inch Digital Inline Pressure Control Valves SM64504

IS7.6 INSTALLATION MANUAL

INSTRUCTION MANUAL AND PARTS LIST FOR 3SIC AND 4SIC SERIES PUMPS

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

NUMBER: S.M. REF.: Listed in Table ENGINE: EPA07 Series 60 DATE: October 2012 SUBJECT: REFERENCES TO THE TURBOCHARGER PURGE ROUTINE

1451 Control Valve. General Instructions. Table of Contents

Product Service Manual For DLH12DHT SERIES PUMPS

LU27 Series Quick Start

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Disassembly and Assembly

CSA products for waste water. Combination air valve. Mod. SCF 2

Installation, Operation, and Maintenance Manual

RB-90 RUPTURE DISK, RB-7R, RB-7FF AND RB-7FS SAFETY HEAD INSTALLATION INSTRUCTIONS

1750 RPM Centrifugal Pumps

MUELLER. Super Centurion 350 Fire Hydrant. Reliable Connections. Inspection and Maintenance 2. Filling Oil Reservoir 3. Facing the Hydrant 4

1 set. Bulkhead Fitting, flat seal, washer & lock nut. 1 ea. Grommet Adapter. 1 ea. ½ male quick connect. 5 ea. Wire clamps.

Installation, Operation and Maintenance Manual for Pressure/Vacuum Relief Valves

Installation, Operation and Maintenance Manual for Pressure/Vacuum Relief Valves (Spring Loaded)

Sea Pro FH240 Series Filter/Separator Installation Instructions

INSTALLATION OF TYPE ZSP PTO DRIVEN Fire Pump

Transcription:

Drilling Series SC Series Cellular Suction Stabilizers Instruction, Operating & Maintenance Manual Manufacturer of Pulsation Control Products 3309 Essex Dr. Suite 200, Richardson, Texas 75082 Phone: 972.699.8600 Fax: 972.699.8602 2018 All Rights Reserved Rev10.1.2018

PREFACE Pg 2 This manual describes operating practices, periodic inspection and maintenance procedures applicable SC-Series Maintenance Free Cellular Suction Stabilizers contained herein reflects recommendations based on industry best practices and recognized safety protocols. Use of the information and procedures contained in this manual is voluntary and is to be implemented at the sole discretion of the user.the user is at all times responsible for operating and maintaining pulsation dampeners in a manner that is safe, conforms to the owner s established business practices, and is in conformance with applicable regulations. NOTE: Please read all instructions carefully before proceeding with the installation, operation, and charging of this equipment. Contact Performance Pulsation Control for assistance or questions concerning the information in this manual. 2018 Performance Pulsation Control, Inc. All Rights Reserved

INSTALLATION START UP OPERATION Pg 3 MATERIALS NEEDED: General Hand Tools INSTALLATION: Before installation, visually check the dampener or stabilizer for damage. NOTE: For maximum performance, dampeners or stabilizer should be installed as close as possible to the pump on which it is to be used. Verify that the mounting provision location is no more than 10 times the relevant pipe diameter from the pump discharge or suction interface. INSTALLATION INSTRUCTIONS 1. Lift the stabilizer using the lifting lugs, or by slings in a location that provides a stable, safe lift. Only lift the stabilizer after completely drained. 2. Install the suction stabilizer within the piping as indicated by the direction arrow on the inlet connection. Bolting should be per standard piping practices. Flange gaskets should be suitable for the service. START UP: Be sure that prior to start-up the dampener or stabilizer is fully primed. This will avoid trapped air being absorbed into the fluid flow and increasing the time to achieve maximum performance. WARNING If the fluid is toxic, flammable, or corrosive, take proper precautions to remove the vapor. 1. Turn on pump and set to operating conditions. 2. Slowly open the vent until liquid comes out, then immediately close the vent. Take care to capture any fluid that flows out in order to prevent spillage or area contamination. LOW TEMPERATURE OPERATION To prevent damaging the stabilizer from freezing of liquids in the system during operation or shut-down, it should be protected from freezing temperatures or drained if freezing temperatures are expected. NOTE: Suction stabilizers and connecting piping require proper support in order to reduce nozzle and piping loads.support should be provided with PPC's standard footpads or with special piping supports as may be specified by user.

INSPECTION AND MAINTENANCE OVERVIEW This equipment is intended to be maintenance free for long periods of time, however the cellular tube(s) contained inside will most likely need to be replaced at some future time. As with all pressure vessels, some general inspection of equipment is recommended. Both the suction stabilizer and the pump are subjected to the same pressures and effects imposed by the pumped media. This means that over time the effects of the pumping action and pump flow can deteriorate components. The following recommendations are made for inspection and maintenance of PPC Cellular Suction Stabilizers, General review of all components of the suction stabilizer should be done on the regular scheduled timing of your major component inspection and maintenance - every 12 to 24 months is a general guideline in lieu of no other set standard. Minimally, the review should consist of inspection of the following items: 1. Cellular Tube(s) 2. Vent (if applicable) 3. Drain (if applicable) 4.Gasket Seal Surfaces 5. Pressure Vessel Integrity 6. Footpads 7. Lift Lugs INSPECTION PROCEDURE: 1. Isolate the suction stabilizer form the suction system and the manifold of the pump. 2. Relieve pressure off of the suction stabilizer using system vent, stabilizer vent, if available or stabilizer drain, if available. Refer to standard procedures for proper management of corrosive or otherwise dangerous fluids. Capture fluid flowing out. Pg 4 4. Vent and drain openings should be opened to verify that the passages are still clear for the purpose which it was intended. NOTE: In either case, the openings may require periodic cleaning to keep the openings operational. The openings will tend to plug with the barite and solids present in the drilling process. 5. The cellular tube(s), located in the cylindrical portion of the body of the unit will need to be removed for inspection. This requires the large body flange at the end of the cylindrical section of the unit to be unbolted, exposing the cellular tube(s) for removal. NOTE: The system flange connected to the suction stabilizer inlet flange may need to be unbolted. Disconnect the system flange from the suction stabilizer inlet to allow the large body flange to be removed. 6. Remove the cellular tube(s) completely from the unit and set on the ground for inspection. 7. Wash the cellular tube with compatible fluids used in general service of the unit to remove all mud and solids from surfaces. Take care to capture any fluid that flows out in order to prevent spillage or area contamination. 8. Examine the outer skin surface of the cellular tube to insure that no mechanical or chemical damage has occurred to these surfaces. The inside diameter, outside diameter, and ends need to be examined for any damage. 9. Check the cellular tube to insure that the tube has not been chemically damaged. It should be round in shape and relatively stiff in its ability to retain this round shape. A tube should be spongy or springy and return to its original shape after pressure is applied. 10. The body of the vessel can be inspected with the large body flange removed.

INSPECTION 11. Examine inside the suction stabilizer for any solids or drilling mud buildup. Clean any solids out of the unit to insure that the full volume of the stabilizer is usable. 12. Check to the process nozzle areas for any evidence of wear or erosion due to flow of drilling mud through the unit. 13. Inspect the baffle plate (only certain units are equipped with this) located in the lower section of the vessel below where the cellular tubes are located. Check for any mechanical damage, wear or erosion of the baffle plate. 14. Inspect the inside of the vessel for any other signs of wear or damage that seem unusal. 15. Inspect all gasket seal surfaces and flanges. Clean or repair as necessary. 16. After inspection of suction stabilizer body and cellular tube if the suction stabilizer appears to be in good working condition, the unit needs to be reassembled and readied for service. 22. Insure that the drain plug is sealed properly, taking care not to cross thread. Pg 5 23. Fill unit with process fluid and vent all air from suction stabilizer to insure that no air may flow directly into pump. Close/replace vent plug, taking care not to cross thread. 24. Prepare suction stabilizer for system use by opening the appropriate suction system valves. Please use all safety measure required to insure that all procedures performed do not place risk on any personnel or equipment. CORROSIVE FLUID INSPECTIONS If pumping a corrosive fluid, please complete an appropriate inspection of the pressure vessel based on your company's policies, local regulation, or on a 1-2 year interval. 17. Replace new or existing cellular tube(s), as applicable into the body of the unit by sliding the tube through the large body flange opening. The tube should easily clear the opening during this procedure. If there is any interference, do not force the tube into the vessel. Remove and identify the problem before continuing. 18. Install new gasket onto body flange facing, being careful to insure correct size and rating is used. 19. Replace blind flange assembly onto body flange. 20. Re-install studs and nuts. Torque studs and nut using standard practice. 21. If applicable, reconnect the system flange to the suction stabilizer inlet flange with the existing fasteners (bolts or studs/nuts). Torque studs and nuts using standard practice.