Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Similar documents
Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

General Purpose Relay

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Ordering Information. Text PCB Power Relay G5LE

Type Terminal Coil Contact form Model

General Purpose Relay

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

General Purpose Relay

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

Ordering Information. Text Surface-Mounting Signal Relay G6K

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Model Number Structure

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

Model Number Structure

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

1 Form A 5A small size power relay for interface

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Operation angle Return angle Output rating Operating voltage Model 40 to to VDC 2.4 to 3.6 VDC D6BN-1P

Subminiature Basic Switch

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

2c 15A, 4c 10A polarized power relays

Model Number Structure

Type List. Standard Type. High Power Type

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

Industrial Relay KML(1C, 2C)

General Purpose Relay

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

Mechanical Key Switch

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

RU Series Universal Relays

Power Contactor with Mirror Contacts

A22NK. Key-type Selector Switches

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Features. Type List. Ordering Information S - 1A - - C - Contact Rating

The full feature relay includes the combination for rotary button or plain button or light or indicator flag.

TV-5, TV-8 rated 10mm flat power relays Silent type is available

Tactile Switch (Hinged Type)

B3F. Miniature, Space-saving Switch

Selection Guide Automotive Relays

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Lighted Pushbutton Switch

General Purpose Low Power PCB Relays

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

Model Number Structure

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

Z b. General Purpose Relays PCB Relays SCHRACK. Power PCB Relay RT1

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Ordering Information. Solid State Relay G3NA. New Models with 75-A and 90-A Output Join the Previous Models with 5- to 50-A Output.

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Switching Power Supply

Relays & Sockets. RQ Series PCB Relays

GE Industrial Systems. General Purpose Plug-in Relays. Catalog

6mm and 14mm Slim Interface Relay

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

Features. * 2 Form C contact. * High switching capacity 60W, 125VA. * Fit standard 16 pin IC socket. * Epoxy sealed for automaitc-wave COIL

Model Number Structure

Transcription:

Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30 VDC. Sealed construction allows automatic soldering and cleaning. Long service life: up to 300,000 operations with a 2 A, 250 VAC/30 VDC load. Rated for D150 pilot duty by UL, CSA. Optional mounting socket simplifies relay installation and servicing of finished equipment. RoHS Compliant. RCE Ordering Information To Order: Select the part number and add the desired coil rating, (e.g., G6D-1A-ASI-DC12). Type Contact form Terminal Construction Model Standard SPST-NO PCB Fully sealed G6D-1A-ASI Accessories Connecting Socket PCB mount socket for G6D relay Description P6D-04P Model Specifications Contact Data Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC Contact material Ag alloy Carry current 5 A Max. operating 250 VAC, 30 VDC Max. operating current 5 A Max. switching capacity 1,250 VA, 150 W 500 VA, 60 W Min. permissible load 10 ma at 5 VDC Note: P level: λ 60 = 0.1 x 10-6 /operation Power PCB Relay G6D-ASI 145

Coil Data Rated (VDC) Rated current (ma) Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C (73 F) with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23 C (73 F). 3. The pick-up is 75% or less of rated if the relay is mounted upside down. Characteristics Note: Data shown are of initial value. Characteristic Data Coil resistance (Ω) Pick-up Dropout Maximum Power consumption (mw) % of rated 5 40 125 70% max. 10% min. 160% at 23 C Approx. 200 12 16.7 720 24 8.3 2,880 Contact resistance 100 mω max. Operate time 10 ms max. Release time 5 ms max. Operating Mechanical 18,000 operations/hour frequency Electrical 1,800 operations/hour (under rated load) Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC, 50/60 Hz for 1 minute between coil and contacts 750 VAC, 50/60 Hz for 1 minute between contacts of the same polarity Surge withstand 6,000 V, 1.20 x 50 μs between coil and contacts Vibration Mechanical durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude Malfunction durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude Shock Mechanical durability 1,000 m/s 2 (approx. 100 G) Malfunction durability 100 m/s 2 (approx. 10 G) Ambient temperature Operating -25 to 70 C (-13 to 158 F) Humidity 5% to 85% RH Life expectancy Mechanical 20 million operations min. (at operating frequency of 18,000 operations/hour) Electrical 70,000 operations min. at rated loads (300,000 operations min for 2A at 250 VAC, 30 VDC, resistive load) Weight Approx. 3 g (0.10 oz) Maximum Switching Capacity Switching current (A) 50 30 10 5 3 1 0.5 0.3 DC resistive load DC inductive load AC resistive load AC inductive load cosφ=0.4 Life Expectancy Life Expectancy (x10 4 operations) 500 300 100 50 30 10 5 3 250-VAC/30-VDC resistive load 250-VAC/30 VDC inductive load (cosφ=0.4/ L/R=7 ms) Ambient Temperature vs. Maximum Coil Voltage Maximum coil (%) 200 180 160 140 120 100 80 0.1 0 3 5 10 30 100 250 500 1,000 Switching (V) 0 1 2 3 4 5 6 7 8 9 10 Switching current (A) 60 0 23 30 40 50 60 70 80 90 Ambient temperature ( C) Note: The maximum coil is the maximum that can be applied to the relay coil. 146 Power PCB Relay G6D-ASI

Pickup and Drop out (ratio of rated ) (%) Ambient Temperature vs. Pickup and Drop out Voltage G6D-1A-ASI 100 80 60 40 20 Sample: G6D1A Quantity: 5 Operating Recovery max. X min. max. X min. 0 40 20 0 20 40 60 80 Ambient temperature ( C) Malfunctioning Shock G6D-1A-ASI X Y 1,000 800 600 400 200 206 Z' X' Shock direction Not energized Y X X' Z Energized Y' Z' Unit: m/s 2 Y' Coil terminals Measurement conditions: Impose a shock in the ±X, ±Y, and ±Z directions three times each with the Relay energized to check the shock values that cause the Relay to malfunction. Z Dimensions Unit: mm Note: Orientation marks are indicated as follows: Relays G6D-1A-ASI 0.5 17.5 max. (17.3)* 6.5 max. (6.4)* 12.5 max. (12.4)* Terminal Arrangement/ Internal Connections (Bottom View) (1.13) (0.71) Mounting Holes (Bottom View) Tolerance: ±0.1 Four, 1.1-dia. holes 3.5 1 5 7 0.5 7.62. 0.8 *Average value 0.3 13 15.24 Socket P6D-04P 6.9 max. (6.7)* 6+0.1 19.7 max. (19.5)* 10.8 (2.18) (0.86) Mounting Holes (Bottom View) Tolerance: ±0.1 Four, 1.1-dia. holes 0.65 0.3 76.2 *Average value 3.6 15.24 Power PCB Relay G6D-ASI 147

Approvals The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. UL Recognized (File No. E41515) - - Ambient Temp. = 40 C Model Number of poles Coil ratings Contact ratings Number of test operations G6D-1A-ASI 1 5 to 24 VDC 5 A, 250 VAC 6,000 5 A, 30 VDC CSA Certified (File No. LR31928) Model Number of poles Coil ratings Contact ratings Number of test operations G6D-1A-ASI 1 5 to 24 VDC 5 A, 250 VAC (General Use) 6,000 5 A, 30 VDC (Resistive) EN/TÜV Approval (Registration No. R50029064/EN61810-1) Model Number of poles Coil ratings Contact ratings Number of test operations G6D-1A-ASI 1 5, 12, 24 VDC 5 A, 250 VAC (cosφ=1.0) 70,000 5 A, 30 VDC (0 ms) Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, TUV) may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. Precautions Spacing Between Relays More than two relays can be closely mounted right side up as shown in the illustration below. 6.5 mm Current flow: 5 A max. Socket Mounting When mounting the relay, insert it into the socket as vertically as possible so that the relay terminals contact securely with the contact pins on the socket. The P6D-04P socket is flux-resistant. Do not wash the socket with water. Remove the relay from the socket before soldering the socket to a PC board. Mounting height More than two relays can be closely mounted upside down as shown in the illustration below. 18.5 mm max. 7.62 mm in the upside-down direction Current flow: 2 A max. 1.12 mm Note: The space between each relay required for heat radiation may vary with operating conditions. 148 Power PCB Relay G6D-ASI

Power PCB Relay G6D-ASI MEMO

All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X301-E-1b 09/11 Specifications subject to change without notice OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Printed in USA Power PCB Relay G6D-ASI

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: P6D-04P