R-Frame Molded Case Circuit Breakers Selection Guide
Product Selection Product Selection 2500 A, R-Frame UL 489 Note: Terminal box lugs must be ordered separately. CSA 22.2, No. 5 IEC 60947-2 CE KEMA-KEUR Assembled Circuit Breakers, Electronic Trip Units Rated Current 1600 2000 2500 1600 2000 2500 Adjustment Range I r [A] Select proper rating plug to cover thermal trip equipment. Rating Plugs Protection Type Breaking Capacity (50 Hz) Protection I cu /I cs [ka] Interrupting Rating (60 Hz) [ka] Type 220 240V 380 415V 500V 690V 240V 480V 600V LS 135 100 70 50 25 13 125 65 50 140U-R6L3-E16 LSI 135 100 70 50 25 13 125 65 50 140U-R6H3-E16 LSG 135 100 70 50 25 13 125 65 50 140U-R6G3-E16 LSIG 135 100 70 50 25 13 125 65 50 140U-R6I3-E16 LS 135 100 70 50 25 13 125 65 50 140U-R6L3-E20 LSI 135 100 70 50 25 13 125 65 50 140U-R6H3-E20 LSG 135 100 70 50 25 13 125 65 50 140U-R6G3-E20 LSIG 135 100 70 50 25 13 125 65 50 140U-R6I3-E20 LS 135 100 70 50 25 13 125 65 50 140U-R6L3-E25 LSI 135 100 70 50 25 13 125 65 50 140U-R6H3-E25 LSG 135 100 70 50 25 13 125 65 50 140U-R6G3-E25 LSIG 135 100 70 50 25 13 125 65 50 140U-R6I3-E25 100 ka @480V LS 200 100 100 50 35 18 200 100 65 140U-R0L3-E16 LSI 200 100 100 50 35 18 200 100 65 140U-R0H3-E16 LSG 200 100 100 50 35 18 200 100 65 140U-R0G3-E16 LSIG 200 100 100 50 35 18 200 100 65 140U-R0I3-E16 LS 200 100 100 50 35 18 200 100 65 140U-R0L3-E20 LSI 200 100 100 50 35 18 200 100 65 140U-R0H3-E20 LSG 200 100 100 50 35 18 200 100 65 140U-R0G3-E20 LSIG 200 100 100 50 35 18 200 100 65 140U-R0I3-E20 LS 200 100 100 50 35 18 200 100 65 140U-R0L3-E25 LSI 200 100 100 50 35 18 200 100 65 140U-R0H3-E25 LSG 200 100 100 50 35 18 200 100 65 140U-R0G3-E25 LSIG 200 100 100 50 35 18 200 100 65 140U-R0I3-E25 800 140U-R16RP3-E80 1000 140U-R20RP3-E10 1200 140U-R25RP3-E12 1000 140U-R16RP3-E10 1200 140U-R20RP3-E12 1250 140U-R25RP3-E125 1200 140U-R16RP3-E12 1250 140U-R20RP3-E125 1600 140U-R25RP3-E16 1250 140U-R16RP3-E125 1400 140U-R20RP3-E14 2000 140U-R25RP3-E20 1400 140U-R16RP3-E14 1600 140U-R20RP3-E16 2500 140U-R25RP3-E25 1500 140U-R16RP3-E15 2000 140U-R20RP3-E20 1600 140U-R16RP3-E16 Protection Type LS LSI LSG LSIG Short Time Range 2 8 x I n 2 8 x I n 2 8 x I n 2 8 x I n Short Time Delay 1 300 ms 1 300 ms Ground Fault Pickup 200 1200 A 200 1200 A Ground Fault Delay 1 500 ms 1 500 ms Protection Type Definitions L: Adjustable long delay pickup (by adjustable rating plug) S: Adjustable short delay pickup with fixed short delay time (I2t response) or adjustable short delat time (flat response) I: Adjustable instantaneous pickup by setting short delay time to instantaneous G: Adjustable ground fault pickup with adjustable ground fault delay (flat response) 2
Accessories Internal Control Modules Field Installed Description Auxiliary Contact (AX) Electrically indicates "ON/OFF" status of breakers (2) N.O-N.C. 140U-R-EA2 Auxiliary/Alarm Contact (AX/AL) Combination Combination of auxiliary contact and alarm contact Shunt Trip (SNT) Provides remote tripping of the circuit breaker Undervoltage trip not available when shunt trip is used (1) 1a, 1b (1) 1 Make, 1 Break 220 250V DC or 380 440V AC 480 600V AC 140U-R- EA1R1 140U-R-SNN 140U-R-SNB Undervoltage Release (UVT) Automatically trips breaker when voltage falls between preset value, 35 70% Shunt trip is not available when undervoltage release is used 208 240V AC Right hand only 140U-R-UVA 24V DC Right hand only 140U-R-UVZJ 48 60V DC Right hand only 140U-R-UVZZ 120V DC Right hand only 140U-R-UVZS 220 250V DC Right hand only 140U-R-UVZA 380 480V AC Right hand only 140U-R-UVN 12V DC Right hand only 140U-R-UVZQ 110 127 V AC Right hand only 140U-R-UVD 3
Accessories External Accessories Description 4 ft (1.3 m) Cable 140U-R-FCX04 Flex-Cable Operating Mechanism Includes handle, cable, operating, and bail mechanism Pre-assembled and adjusted Non-Metallic - UL IP66, Type 1/3/12/4/4X Flange Mount Operating Handle 6 ft (1.8 m) Cable 140U-R-FCX06 Rotary, Variable-Depth Operating Mechanism Type 1/12 Rotary Handle 12 in. (30.48 cm) operating rod Black Handle 140U-R-RM12B 1600 A size Aluminum lug, Al or Cu wire (4) 500 1000 MCM or (4) 300 500 mm2 140U-R-TLA4 Terminal Lugs 1600 A size Copper lug, Cu wire only (4) 1 600 MCM or (4) 50 300 mm2 140U-R-TLC4 Terminal Lugs 2000 A size Aluminum lug, Al or Cu wire (6) 2 600 MCM or (6) 35 300 mm2 140U-R-TLA6 1600 A size copper rear 140U-R-RCC16 Rear Connector 2000 A size copper rear 2500 A size copper rear 140U-R-RCC20 140U-R-RCC25 4
Approximate Dimensions Dimensions are in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Approximate Dimensions Approximate Weights 140U-R1600 140U-R2000 140U-R2500 Weight 102 lbs 102 lbs 135 lbs Rockwell_Power_Molded_Case_140U_R-Frame_Select_en_0611.pdf Helsinki tel. +358 9 540 4940 automation@klinkmann.fi St. Petersburg tel. +7 812 327 3752 klinkmann@klinkmann.spb.ru Moscow tel. +7 495 641 1616 moscow@klinkmann.spb.ru Yekaterinburg tel. +7 343 376 5393 yekaterinburg@klinkmann.spb.ru Samara tel. +7 846 273 95 85 samara@klinkmann.spb.ru Кiev tel. +38 044 495 33 40 klinkmann@klinkmann.kiev.ua Riga tel. +371 6738 1617 klinkmann@klinkmann.lv Vilnius tel. +370 5 215 1646 post@klinkmann.lt Tallinn tel. +372 668 4500 klinkmann.est@klinkmann.ee Мinsk tel. +375 17 200 0876 minsk@klinkmann.com