Project Number Date 17.01932 7/21/2017 Test Sample Description Catalog Number: Description: P90812827K9 Med Step Design Track Lighting Lab 1 Sphere Photometry Test Method: Preburn Time: Time To Stabilize: Total Operating Time: Input Voltage (Volts) : Input Current (Amps) : Input Wattage (Watts) : Ambient Temp ( C) : Sphere IES LM-79-08 10 Test Method: IES LM-79-08 9.1 & 12.1 00:05 Preburn Time: 0:10 0:55 Time To Stabilize: 1:13 1:50 Total Operating Time: 1:23 120.1 Input Voltage (Volts) : 120.0 0.059 Input Current (Amps) : 0.059 6.9 Input Wattage (Watts) : 6.9 24.1 Ambient Temp ( C) : 24.0 Hubbell Lighting, Inc. 701 Millennium Boulevard Checked (sphere) : Checked (photometry) : Approved: B. LEE D. ROBBINS D. BLACK TESTING NVLAP LAB CODE: 201003-0 This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Page 1 of 8
Test #: 17.01932 Date: 7/21/2017 Lamp Cat#: Lamp Desc: Driver Desc: BXRE-27G0800-B 1 - Bridgelux 2700K LEDs N/A Efficacy: 70.3 LPW S/P Ratio: 1.3 LM'/LM Spectral Results Name Value Unit Φ 1.67 watts Φ(v) 485 lumens Φ(v') 650 lm' Chrom x 0.4497 Chrom y 0.4052 Chrom u 0.2583 Chrom v 0.3491 Duv 0.0012 Chrom u' 0.2583 Chrom v' 0.5237 CCT 2803 K Purity 56.6 % λ (dom) 584.1 nm FWHM 141.8 nm λ (peak) 621.8 nm λ (center) 607.1 nm λ (centroid) 595.6 nm SDCM Cool White RA 91 Corr. Coef. 0.00111766 Correlation 0.0054 R1 90.5 R2 96.8 R3 97.0 R4 88.7 R5 90.6 R6 95.9 R7 88.7 R8 76.7 R9 51.4 R10 92.1 R11 88.9 R12 83.0 R13 92.1 R14 99.2 Spectral Radiant Flux (W) Spectral Distribution of Radiant Flux 1.20E-02 1.00E-02 8.00E-03 6.00E-03 4.00E-03 2.00E-03 0.00E+00 350 450 550 650 750 850 Wavelength (nm) This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Page 2 of 8
REPORT NUMBER: 17.01932 LUMINAIRE: Med Step Design Track Lighting LAMP CAT. NO.: BXRE-27G0800-B LAMP: 1 - Bridgelux 2700K LED MOUNTING: Ceiling / Track NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED. PAGE: 3 OF 8
REPORT NUMBER: 17.01932 PAGE: 4 OF 8 DEG CANDELA LUMENS 0 1364 5 1242 104 15 415 123 25 199 93 35 157 90 45 20 24 55 8 7 65 4 4 75 2 3 85 0 0 90 0 ZONAL LUMEN SUMMARY ZONE LUMENS %FIXT 0-30 320 71.3 0-40 411 91.4 0-60 442 98.4 0-90 449 100.0 90-180 0 0.0 0-180 449 100.0 EFFICACY = 65.5 lm/w CIE TYPE - DIRECT LUMINAIRE SPACING CRITERION = 0.39 PLANE : 0-DEG 90-DEG SHIELDING ANGLES : 90 90 LUMINOUS DIAMETER: 2.250 LUMINANCE DATA IN CANDELA/SQ M ANGLE AVERAGE IN DEG 45 11026. 55 5437. 65 3690. 75 3012. 85 0. 500 1000 1500 90 75 60 45 0 15 30
REPORT NUMBER: 17.01932 PAGE: 5 OF 8 CANDELA DISTRIBUTION 0.0 1364 2.5 1337 5.0 1242 7.5 1053 10.0 815 12.5 592 15.0 415 17.5 306 20.0 253 22.5 220 25.0 199 27.5 183 30.0 173 32.5 166 35.0 157 37.5 128 40.0 87 42.5 45 45.0 20 47.5 15 50.0 12 52.5 10 55.0 8 57.5 6 60.0 5 62.5 5 65.0 4 67.5 4 70.0 4 72.5 3 75.0 2 77.5 2 80.0 1 82.5 0 85.0 0 87.5 0 90.0 0
REPORT NUMBER: 17.01932 PAGE: 6 OF 8 5-DEGREE ZONAL LUMEN SUMMARY 0-5 31 5-10 73 10-15 70 15-20 52 20-25 47 25-30 47 30-35 49 35-40 42 40-45 18 45-50 6 50-55 4 55-60 3 60-65 2 65-70 2 70-75 2 75-80 1 80-85 0 85-90 0 10-DEGREE ZONAL LUMEN SUMMARY 0-10 104 10-20 123 20-30 93 30-40 90 40-50 24 50-60 7 60-70 4 70-80 3 80-90 0
REPORT NUMBER: 17.01932 PAGE: 7 OF 8 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 119119119119 116116116116 111111111 106106106 102102102 100 1 114111109107 111109107105 105103102 101100 99 98 97 96 94 2 109104100 97 106102 99 96 99 96 94 96 94 92 93 91 90 88 3 104 97 93 89 102 96 92 88 94 90 87 91 88 86 89 86 84 83 4 99 92 87 83 97 91 86 82 89 84 81 87 83 80 85 82 79 78 5 94 87 81 77 93 86 81 77 84 80 76 82 79 76 81 78 75 74 6 90 82 77 73 89 81 76 72 80 75 72 79 74 71 77 74 71 70 7 87 78 72 69 85 77 72 68 76 71 68 75 71 68 74 70 67 66 8 83 74 69 65 82 74 69 65 73 68 65 72 67 64 71 67 64 63 9 80 71 66 62 79 70 65 62 70 65 62 69 64 61 68 64 61 60 10 77 68 63 59 76 67 62 59 67 62 59 66 62 59 65 61 59 57 ALL CANDELA, LUMENS, LUMINANCE, AND VCP VALUES IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY. THE COEFFICIENT OF UTILIZATION VALUES ARE BASED ON THE TOTAL ABSOLUTE LUMEN OUTPUT OF THIS TEST SAMPLE.
Project Number Date 17.01932 7/21/2017 Goniophotometer Calibration Calibration Lamp : GE 1000W, 120V, T6, CL (FEL) Lamp Number: ITL78966-1000-38 Calibration Current: 8.300 Amps DC Total Luminous Flux: 25889.0 Lumens Calibration Date: 07/10/2017 Test Equipment Used Instrument Manufacturer / Model S/N Calibration Due: Goniophotometer ITL/HLI LAB 1 - Test Distance: 31.74' N/A N/A Power Analyzer Yokogawa / WT 332 C2QA27071V 11/2/2017 Power Source Voltage-Regulated House Power N/A N/A Thermometer National Instruments / USB-TC01 176F4EB 11/7/2017 Sphere Calibration Calibration Lamp: EIKO 28V75W/E10 Lamp Number: SCL-1400-J136 Calibration Current: 2.679 Amps Total Luminous Flux: 1427 Lumens Test Equipment Used - Color & SPD; THD & Power Factor Instrument Manufacturer / Model S/N Calibration Due: 3-Meter Sphere Labsphere / LMS-3M N/A Calibrated Weekly Thermometer National Instruments / USB TC01 1912751 11/2/2017 LAMP Power Meter Yokogawa / WT332 C2QA27075V 11/1/2017 Power Supply Chroma / 61602 616020002113 N/A Aux Lamp Supply Labsphere / LPS-100-0833 031159372 10/31/2017 Cal Lamp Supply Labsphere / LPS-150-0268 1218148505 12/1/2017 Spectrometer Labsphere / CDS 1100 0624117792 N/A Hubbell Lighting, Inc. 701 Millennium Boulevard This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Page 8 of 8