Seal-less Pump Technology. Oil and Gas. Robust design - Reliability

Similar documents
Chemical and Petrochemical Process

Chemical and Petrochemical Process

Oil & Gas Processing. Seal-less Pumps. Reliable Pumps for Oil and Gas Processing with No Seals or Packing to Leak or Replace

Water and Waste Water Treatment

Reliable Pumps for Oil and Gas Processing with No Seals or Packing to Leak or Replace. Oil & Gas Processing

G10 Series API bar (350 psi) for Non-metallic Pump Heads. G10 with Cast Iron pump head

69 bar (1000 psi) for Metallic Pump Heads 24 bar (350 psi) for Non-metallic Pump Heads

G35 Series API bar (1500 psi) for Metallic Pump Heads. G35 with Stainless Steel pump head and SAE flanges. G35 with Brass pump head

Condensed Catalog. Seal-less Pumps

G20 Series. 24 bar (350 psi) for Non-metallic Pump Heads. G20 Close-coupled with Brass pump head ATEX. G20 Version 5 10/16

G25 Series API bar (350 psi) for Non-metallic Pump Heads. G25 with Cast Iron pump head

Seal-less Pump Technology

103 bar (1500 psi) for Metallic Pump Heads

G15 Series API bar (2500 psi) for Metallic Pump Heads. G15 for horizontal installations shown with Stainless Steel pump head.

G10 Series API bar (350 psi) for Non-metallic Pump Heads. G10 with Cast Iron pump head

T100 Series Medium Pressure Models T100K & T100M

G66 Series API bar (250 psi) for Non-metallic Pump Heads. G66 with Ductile Iron pump head. G66 with Polypropylene pump head.

Versatile, Reliable Pumps for a Wide Range of Applications D35 Series

G03 Series. 24 bar (350 psi) for Non-metallic Pump Heads. G03 Shaft-driven with Stainless Steel pump head

T100 Series Low Pressure Models T100E, T100F & T100H

Versatile, Reliable Pumps for a Wide Range of Applications H25 Series

Versatile, Reliable Pumps for a Wide Range of Applications D10 Series

T100 Series Medium Pressure Models T100K & T100M

G03 Series Dosing Range

T100 Series Medium Pressure Models T100K & T100M

Accurate Metering and Superior Handling of Abrasives in the Manufacture of Engineered Wood Products. Engineered Wood

T100 Series Low Pressure Models T100E, T100F & T100H

G03 Mono-Block Series

Metering Pumps with Pulse-Free Linear Flow

Versatile, Reliable Pumps for a Wide Range of Applications M03 Series

High-Pressure Machine Tool Coolant Pumps with Superior Handling of Abrasive Fines and Metal Particles. Machine Tool Coolant

MT8 Pump. Triplex Metering Pump with Pulse-Free Linear Flow

Versatile, Reliable Pumps for a Wide Range of Applications M03 Series

G04 Series. Maximum Flow Rate: 11.2 l/min (2.9 gpm) Maximum Pressure: 200 bar (2900 psi) for Metallic Pump Heads. G04 with Stainless Steel pump head

Metering Pumps with Pulse-Free Linear Flow

T100 Series Medium Pressure Models T100K & T100M

Seal-less Pump Technology

T100 Series High Pressure

G10 Series API bar (350 psi) for Non-metallic Pump Heads. G10 with Cast Iron pump head

Versatile, Reliable Pumps for a Wide Range of Applications D66 Series

MODEL: G-25 WITH METALLIC PUMP HEAD

Model T25 Triplex Power Pump

Versatile, Reliable Pumps for a Wide Range of Applications M03 Mono-Block Series

Models: G-25, H-25 With Non-Metallic Pump Head

Models: G-25, H-25 With Metallic Pump Head

G20 Series. G20 Close-coupled with Brass pump head ATEX. G20 Version 1 01/15

INDUSTRIAL PUMPS MODEL: D-35 PARTS MANUAL WANNER ENGINEERING, INC. IMPORTANT

Hydracel High Pressure Pump

H/G-25 Series. Up to 20 gpm (75.7/min) H/G-25 Specialized Designs

Seal-less Pump Technology

D/G-35 Series. Up to 37gpm (140 l/min) D/g-35 hydra-cell diaphragm pump. D/G-35 Specialized Designs

Model: D-10. Parts Manual D B. with non-metallic pump head WANNER ENGINEERING, INC. IMPORTANT

H/G-25 Series. Up to 20 gpm (75.7/min) H/g-25 hydra-cell diaphragm pump. H/G-25 Specialized Designs

Pulsation Dampeners NEW! Wanner Engineering Inc

D/G-10 Series. Up to 8 gpm (30.3 l/min) D/g-10 hydra-cell diaphragm pump. D/G-10 Specialized Designs

Electronic Precision Metering. Built to exceed API 675 performance standards with pulse-free linear flow

Models: D-12, G-12. Parts Manual D D WANNER ENGINEERING, INC.

PULSAPRO HYDRAULIC DIAPHRAGM METERING PUMP API-675 ENGINEERED PRODUCTS. Flow: up to 270 gph (1,022 lph) Pressure: up to 5,100 psi (350 bar)

Models: D-03, G-03, G-13 and M-03

PULSAPRO HYDRAULIC DIAPHRAGM METERING PUMP API-675 ENGINEERED PRODUCTS. Flow: up to 270 gph (1,022 lph) Pressure: up to 5,100 psi (350 bar)

MODELS: G-20, G-21, G-22

WANNER ENGINEERING INC

Model T5 Triplex Power Pump

Model T10 Triplex Power Pump

F20 Series. Maximum Flow Rate: 1.0 gpm (3.8 l/min) Maximum Pressure: 1500 psi (103 bar) for Metallic Pump Heads

INDUSTRIAL PUMPS PARTS MANUAL MODELS: M-03 D-03 M-23 M-24 G-03 G-13 WANNER ENGINEERING, INC. IMPORTANT

D/G-12 Series. Up to 8 gpm (30.3 l/min)

Model T10 Triplex Power Pump

A pump is a machine used to move liquid through a piping system and to raise the pressure of the liquid.

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

DIAPHRAGM METERING PUMPS

Hydra-Cell Metering Accessories and Options

stream and green PUMPING The new PCM Delasco DX series DX65 - DX80 - DX100

Model T5 Triplex Power Pump

JH Process Equipment Inc. 617 Jeffers Circle, Exton, PA

THE LEADING FORCE behind liquids since 1857

Hydra-Cell T80 Series Pumps Design Advantages

DIAMOND SERIES. With DHP Advantages

KL-RÜ / KL-RQ / KL-RS / KL-R Triplex

AODD PUMPS FOR YOUR MOST SEVERE APPLICATIONS

C Series Valves C24 1-1/4 NPT C23 1 NPT C22 3/4 NPT. C22/C23/C24 Series. Stainless Steel Off-Line Brass Off-Line. Brass In-Line.

VIKING. Viking Mag Drive Series 855. Ideal for: Hard-to-Seal Liquids 24/7 Operations Hazardous and Toxic Liquids

Ultra-Matic Air Valve System

ROTAN INTERNAL GEAR PUMPS. Serving industry since 1921 Available in cast iron, carbon steel, and stainless steel construction

Process Equipment. Pumping Solutions for Process Industries

M03 Series. Maximum Flow Rate: 3.1 gpm (11.7 l/min) Maximum Pressure: 1200 psi (83 bar) for Metallic Pump Heads

ProMinent Meta METERING PUMPS. ProMinent

LPP PUMP LAROX PERISTALTIC PUMPS (LPP)

P400 Metering Pump. Installation, Operation & Maintenance P C. Metallic pump shown W0014B

Positive Displacement Rotary Lobe Pumps

NEMO BT Immersible Pumps - special design for the petroleum industry

Moyno 2000 Pumps Offer Superior Pumping Performance

Process Equipment. Pumping Solutions for Process Industries. Springer Pumps, LLC. Tel: Fax:

THE LEADING FORCE behind liquids TM since Rotary Positive Displacement Pumps

A Series General Purpose Pumps General Purpose Pumps for Pressure Lubrication, Hydraulic Service, Fuel Supply and General Transfer

Selection Guide for P Series Pump Accessories & Options

An IDEX Water & Wastewater Business. pulsafeeder.com. Mechanical Diaphragm Metering Pump

SD Series. Slurry Duty Pumps. Hydra-Cell Slurry Duty pumps are specifically designed for abrasive duty applications in order to:

D/G-04 Series. Up to 3.0 gpm (11.3 l/min)

Process Equipment. Pumping Solutions for Process Industries

Transcription:

Seal-less Pump Technology Oil and Gas Robust design - Reliability

Hydra-Cell Oil & Gas Industry Pumps - High reliability, Gas Extraction Produced water injection Produced water disposal Well dewatering NGL transfer Polymer injection Gas Processing Gas drying Sweetening Odourising Artificial Lift Jet Pumps Power fluid pressurisation Pressure Testing Pipes and well testing 1

compact, seal-less and energy efficient design Oil Refining Steam stripping / generation Additive injection Stack cooling Chemical metering High pressure cleaning Chemical transfer Burner Fuel Feed Emissions Control Solvent transfer Process sampling Seal flushing Water treatment Distribution Gasoline transfer Onshore / Offshore Oil Extraction Well stimulation Produced eater injection Produced eater disposal Chemical injection Methanol injection Polymer Injection Drilling mud injection Crude oil transfer and sampling Injection of drag reducing agents Reverse osmosis & filtration High pressure cleaning Polymer Injection 2

Hydra-Cell Oil and Gas Industry Pumps Compact seal-less pumps for long life and high reliability Gas Drying Pumping hot TEG With over 35 years experience in Oil and Gas industry service, Hydra-Cell pumps have proven performance. In 2010, the new Hydra-Cell T-Series packing free triplex pump received a Spotlight on New Technology award from the Offshore Technology Conference (OTC) Production Transport Refining ATEX Well Injection Metering and Dosing Chemicals Acids Sulphuric, Hydrochloric, Nitric Biocide Injection Caustics Sodium Hydroxide, Potassium Hydroxide Corrosion Inhibitor Demulsifier H2S Scavengers Amines O2 Scavengers Challenges in Pumping Corrosive. Tend to crystallise when cold or in contact with air, forming fine solids which can damage mechanical seals. Very low flow rates, accurate metering of chemicals to optimise usage, minimise environmental damage. Tend to crystallise when cold or in contact with air, forming fine solids which can damage mechanical seals. Very low flow rates, accurate metering of chemicals to optimise usage, minimise environmental damage. Very low flow rates, accurate metering of chemicals to optimise usage, minimise environmental damage. Containment of any H2S saturated in Amine. Responsive accurate control of flow rate. Tend to crystallise when cold or in contact with air, forming fine solids which can damage mechanical seals. The Hydra-Cell Advantage No dynamic seals to be damaged. Unique spring-loaded check valves, which can handle liquids with particles reliably. Unique multiple diaphragm pump head providing virtually pulseless flow for accurate metering. Seal-less pump head means that liquids containing particles can be pumped reliably. Unique multiple diaphragm pump head providing virtually pulseless flow for accurate metering. Unique multiple diaphragm pump head providing virtually pulseless flow for accurate metering. Seal-less pump chamber provides 100% containment. Virtually pulse-less flow gives responsive control with accuracy exceeding API 675 performance criteria. Unique spring-loaded check valves, which can handle liquids with particles reliably. Scale Inhibitor Corrosive. No dynamic seals to be damaged. Sodium Hypochlorite Outgassing. Correct pump selection to achieve higher speed, giving the ability to clear gas quicker. 3

Typical Chemicals and Liquids Pumped Challenges in Pumping The Hydra-Cell Advantage Condensates Non-lubricating. No need for lubrication from pumped liquid. Must be 100% contained to comply with VOC emissions legislation. Seal-less pump chamber provides 100% containment. Crude Oil Range of viscosities makes it difficult to pump. Hydra-Cell seal-less pumping action can handle liquids with viscosities from 0.01 to 6000 cst, or liquids containing a mixture of viscosities. Drag Reducing Agents Very abrasive and highly viscous. No dynamic seals to be damaged by abrasive product Can handle high viscosity liquids. Hot Tri-Ethylene Glycol (TEG) and Diethylene Glycol (DEG) for gas drying Methanol for well icing prevention Natural Gas Liquids Mixtures of Methane, Propane, Ethane Polymers for well stimulation Produced, Salt and Sour Water injection, disposal and transfer Non-lubricating. Liquid temperatures up to 100 C. Controllability of injected TEG /DEG. Non-lubricating, especially pumping at pressure. Non-lubricating. Must be 100% contained to comply with VOC emissions legislation. Shear sensitive gel structures which can be broken down easily. High viscosity. Abrasive, contains soda ash. Responsive accurate control of flow rate. Corrosive. Can contain H2S, salt, CO2 plus other impurities forming acidic solutions. Abrasive. Water contains sand and other contaminants barium, cadmium, sulphur, chromium, copper, iron, lead, nickel, silver and zinc. Containment of H2S gas. No need for lubrication from pumped liquid. No dynamic seals to be damaged. Flow rate directly proportional to pump rpm. RPM adjustable range from 10 rpm to 1500 rpm (1000 rpm for some models). No need for lubrication from pumped liquid. No need for lubrication from pumped liquid. Seal-less pump chamber provides 100% containment. Low shear pumping action. Unique spring loaded check valves for reliable pumping action. Seal-less pump chamber and unique spring loaded check valves allows reliable pumping of liquids with suspended solids. Virtually pulseless flow gives responsive control with accuracy exceeding API 675 performance criteria. Corrosion resistant liquid head materials available Seal-less pumping chamber. Seal-less pump head means that liquids containing particles can be pumped reliably. No dynamic seals to wear. No cups, packing or seals to leak gas Seal-less pump chamber provides 100% containment. 4

Hydra-Cell advantages Designed for continuous use, Hydra-Cell Seal-less Pumps are robust, reliable, efficient and can be used in a wide variety of Oil and Gas applications, lowering the total cost of ownership. Enhanced oil recovery Pumping shear sensitive polymers High reliability low maintenance Having No Dynamic Seals means high reliability. Run dry indefinitely No seals to wear No seals to leak any potentially harmful gases such as H2S No seals to leak any Volatile Organic Compounds No tight tolerances that could be susceptible to corrosion or damaged by solid particles Pumps liquids with viscosities from 0.01 to 6000 cst Pumps non-lubricating liquids reliably Pumps liquids with up to 500µm dia. particulate matter No drop-off in performance due to seal wear Hydra-Cell pumps have no packing Compact design For metering and dosing applications Hydra-Cell s compact design gives real advantages. 1. Space saving 2. Easier servicing 3. Lower initial purchase cost Both pumps are rated at 172 Bar and 110 l/hr Hydra-Cell Weight 27 kg Traditional metering pump Weight 100 kg High efficiencies A true positive-displacement pump, Hydra-Cell is one of the most efficient metering and dosing pumps available. Both pumps are rated at 172 Bar and 110 l/hr Hydra-Cell metering pump Motor 0.75 kw ( 60) Traditional Metering pump Motor 4 kw ( 180) Save up to 65% on motor costs Hydra-Cell multiple diaphragm head means smaller motors can be used, saving energy. 5

Unique spring-loaded check valves Reliably pump acids and caustics which crystallise. Hydra-Cell unique check valves Efficient pumping of liquids with solids such as lime slurries, soured water containing sand. Low shear pumping action Due to the gentle pumping action, shear sensitive liquids, especially polymers, can be pumped without breaking down the long chain structures within the liquids. Energy saving Very economical to run compared with centrifugal pumps. Smaller, more compact motors required. Compared with multi-stage centrifugal pumping water at 20 bar: Flow (m 3 /hr) Energy used (kw) Centrifugal Hydra-Cell Energy saving Potential annual euro saving 0.6 1.54 0.5 67% 945 1.5 2.0 1.44 28% 470 Compared with multi-stage centrifugal pumping water at 40 bar: Gasoline transfer Romania Flow (m 3 /hr) Energy used (kw) Centrifugal Hydra-Cell Energy saving Potential annual euro saving Simple robust design Designed and built for long service life. Simple maintenance with no special tool requirements. 4.2 9.34 6.1 35% 2,830 7.6 15.4 11.0 28% 3,840 No critical tolerances to be aware of during maintenance. On-site repair possible, no costly requirement for removal and transportation to workshops. Minimal filtration No mechanical seals or tight tolerances that need protection by fine filtration. Hydra-Cell pumps can handle particles up to 500 µm, depending on model. Also liquids with non-dissolved solids up to 40%, depending on particle distribution. Unaffected by lapses in filtration, reducing costly pump repairs. Reduced filtration maintenance and management. NGL transfer Russia 6

Ultimate Controllability for Metering and Dosing Metering and dosing performance better than API675. Steady state accuracy better than +/- 1% Repeatability better than +/- 3% This is a measure of how well a set flow rate can be maintained. Linearity (Pump shaft speed/flow rate relationship) better than +/- 3% This is a measure of how accurate the flow rate can be controlled when varying the pump shaft rpm away from a set point and returning to that set point. Virtually pulse-less flow for accurate metering Pulsation dampeners may not be required for most Hydra-Cell pumps, thus reducing the risk of pipe strain More accurate control of flow rate and efficient use of chemicals. Significantly less inlet acceleration head issues than traditional single diaphragm metering pumps, especially with viscous liquids. This is a measure of how accurate the flow rate can be set by changing and setting pump speed. Hydra-Cell pumps Leading brand metering pump Pipe line cleaning 90 C water UK Refinery 7

Hydra-Cell Principles of Operation - Wobble Plate 1 2 3 4 5 7 6 8 Wobble Plate Models 1 Drive Shaft 5 Diaphragms 2 Tapered Roller Bearings 6 Inlet Valve Assembly 3 Fixed-angle Cam/Wobble Plate 7 Discharge Valve Assembly 4 Hydraulic Cells (Patented) 8 C62 Pressure Regulating Valve Reliable, Efficient Pumping Action The drive shaft (1) is rigidly held in the pump housing by a large tapered roller bearing (2) at the rear of the shaft and a smaller bearing at the front of the shaft. Set between another pair of large bearings is a fixed-angle cam or Wobble Plate (3). As the drive shaft turns, the swash plate moves, oscillating forward and back (converting axial motion into linear motion). The complete pumping mechanism is submerged in a lubricating oil bath. The hydraulic cell (4) is moved sequentially by the Wobble plate and filled with oil on their rearward stroke. A ball check valve in the bottom of the piston ensures that the cell remains full of oil on its forward stroke. The oil held in the Hydra-Cell balances the back side of the diaphragms (5) and causes the diaphragms to flex forward and back as the Wobble plate moves. This provides the pumping action. To provide long trouble-free diaphragm life, Hydra-Cell hydraulically balances the diaphragm over the complete pressure range of the pump. The diaphragm faces only a 0.21 bar pressure differential regardless of the pressure at which liquid is being delivered - up to 172 bar on standard Hydra- Cell models and Hydra-Cell metering pumps. Hydra-Cell Wobble plate pumps can have up to five diaphragms, and each diaphragm has its own pumping chamber that contains an inlet and discharge self-aligning spring loaded check valve assembly (6). As the diaphragms move back, liquid enters the pump through a common inlet and passes through one of the inlet check valves. On the forward stroke, the diaphragm forces the liquid out the discharge check valve (7) and through the manifold common outlet. Equally spaced from one another, the diaphragms operate sequentially to provide consistent, low-pulse flow. A Hydra-Cell C62 pressure regulating valve (8) is typically installed on the discharge side of the pump to regulate the pressure of downstream process or equipment. 8

Hydra-Cell Principles of Operation - Crankshaft 7 1 3 2 4 8 6 5 Crank-shaft Models 1 Drive Shaft 5 Diaphragms 2 Precision Ball Bearings 6 Inlet Valve Assembly 3 Connecting Rods 7 Discharge Valve Assembly 4 Hydraulic Cells (Patented) 8 C46 Pressure Regulating Valve (In-line) Reliable, Efficient Pumping Action The drive shaft (1) is supported in position by two precision ball bearings (2) positioned at either end of the shaft. Located between these bearings are either one or three cam shaft lobes with connecting rods (3) that are hardened, precision ground, and polished. Maintaining a high level of quality on the cam lobes and connecting rod surfaces ensures proper lubrication and reduced operating temperatures in the hydraulic end of the pump. As the drive shaft turns, each cam actuates the attached connecting rod that is pinned into position at the end of each hydraulic piston. This action moves the piston forward and backward, converting the axial motion into linear pumping motion. The complete pumping mechanism is submerged in a lubricating oil bath. Each piston contains a patented hydraulic cell (4) that is moved sequentially by the crank-shaft. The innovative and proprietary Hydra-Cell maintains the precise balance of oil behind the diaphragm (5) regardless of the operating conditions of the pump. The oil in Hydra-Cell is pressurized on the forward stroke of the piston causing the diaphragm to flex, 9 which drives the pumping action. The oil held in the Hydra- Cell balances the diaphragm against the liquid being pumped, maintaining no more than a 0.21 bar differential regardless of the pressure at which the liquid is being delivered - up to 172 bar on standard Hydra-Cell models and Hydra-Cell metering pumps. Hydra-Cell crank-shaft pumps can have up to three diaphragms, and each diaphragm has its own pumping chamber that contains an inlet and discharge self-aligning spring loaded check valve assembly (6). As the diaphragms move back, liquid enters the pump through a common inlet and passes through one of the inlet check valves. On the forward stroke, the diaphragm forces the liquid out of the discharge check valve (7) and through the manifold common outlet. Equally spaced from one another, the diaphragms operate sequentially to provide consistent, low-pulse flow. A Hydra-Cell C46 pressure regulating valve (8) is typically installed on the discharge side of the pump to regulate the pressure of downstream process or equipment.

Hydra-Cell Principles of Operation - T Series API 674 option available Exclusive Seal-less Diaphragm Design Seal-less design separates the power end from the process liquid end, eliminating leaks, hazards, and the expense associated with seals and packing Low NPSH requirements allow for operation with a vacuum condition on the suction - positive suction pressure is not necessary Can operate with a closed or blocked suction line and run dry indefinitely without damage, eliminating downtime and repair costs Unique diaphragm design handles more abrasives with less wear than gear, screw or plunger pumps Hydraulically balanced diaphragms to handle high pressures with low stress Provides low-pulse, linear flow due to its multiple diaphragm design Lower energy costs than centrifugal pumps and other pump technologies Rugged construction for long life with minimal maintenance Compact design and double-ended shaft provides a variety of installation options Hydra-Cell T-Series pumps can be configured to meet API 674 standards consult factory for details Hydra-Cell T80 Series pumps received a Spotlight on New Technology award from the Offshore Technology Conference. 10

Hydra-Cell Performance Advantages Traditional Metering Pump Disadvantages Use manual stroke adjusters or expensive actuators to control flow, which can result in pumping inaccuracies, lost motion, operator error, and a greater chance of leakage. Require expensive pulsation dampeners to minimize pulsations. May only offer PTFE diaphragms, requiring frequent replacement due to stress and poor elastomeric memory. Large footprint to achieve required maximum flow and pressure. Different plunger and liquid end sizes needed to accommodate changes in operating pressures. Integral gearing (necessary to prevent cross-contamination of actuating oil) is difficult and expensive to maintain. Hydra-Cell Advantages Utilising Hydra-Cell s unique hydraulic replenishment system, this gives constant diaphragm displacement and compression ratio ensuring consistent flow rate. Multiple-diaphragm design provides virtually pulse-free flow, so expensive pulsation dampeners, in most cases, may not be required. Available with a wide choice of cost-effective, elastomeric diaphragm materials. Can meet the same flow and pressure requirements with a much smaller footprint, saving space and costs. Operates over a wide range of pressures without changes to the plunger or liquid end size. The simplicity of design means lower parts and maintenance costs. Separate gearbox prevents cross-contamination of the actuating oil. Gear Pump Disadvantages Mechanical seals and packing require maintenance, and replacement or adjustment. Does not tolerate thin/non-lubricating liquids, and does not handle solids, abrasives or particulates well. Designed for operating at low speeds and low pressure ratings. Low volumetric efficiency. Component wear reduces accuracy and efficiency. Bearings & bushes run in the pumped liquid. Unbalanced - overhung load on the shaft bearing. Fixed end clearances. Efficiency drops over 103 bar. The meshing action of the gear pump imparts a high-shear to the liquid Hydra-Cell Advantages The seal-less design of Hydra-Cell means that there are no seals or packing to leak or replace. Seal-less pumping chamber and spring-loaded, unique springloaded check valves can pump solids, abrasive fillers and particulates while handling liquids thick or thin. Operates at low-to-high speeds and at higher pressures with higher volumetric efficiency. No internal gears to wear so there is less maintenance and spare part replacement. Accuracy and efficiency are more stable. No bearings in the pumped liquid. Hydraulically balanced design so there is no overhung load. Design does not rely on clearances. Efficiency remains relatively constant over its range of operating pressures. The gentle, low-shear pumping action of the Hydra-Cell pump keeps the liquid in a more stable state for greater predictability and a more constant process. 11

Progressing Cavity Pump Disadvantages Mechanical shaft seals and Rotor / Stator seals are worn by abrasive, non-lubricating liquids. Hydrodynamic film between the stator and rotor can break down under pressure reducing flow rate and not producing a true positive displacement pump action. The meshing action between the rotor and stator imparts a high-shear to the liquid Hydra-Cell Advantages No dynamic seals in the pumped liquid. Can handle abrasive liquids reliably. Seal-less pump chamber with hydraulically balanced diaphragms means that flow rate is maintained, even as discharge pressure increases. The gentle, low-shear pumping action of the Hydra-Cell pump keeps the liquid in a more stable state for greater predictability and a more constant process. Plunger Pump Disadvantages Cannot run dry without damage to the pump. Requires fine filtration to protect dynamic seals. Liquids such as NGL s or Salt Water and corrosive or hot liquids can damage packing and seals. All dynamic seals are designed to leak resulting in crank oil contamination by process liquid and frequent oil changes. The reciprocating action of the plunger pump imparts a highshear to the liquid Hydra-Cell Advantages Seal-less design enables the pump to run dry without damage, indefinitely. No dynamic seals to protect. No need for fine filtration to protect the pump. Recycled liquids and liquids containing particle can be pumped reliably. No dynamic seals, so can handle these liquids reliably. Crank oil and process liquid are completely separated resulting in significantly low frequency of oil change. The gentle, low-shear pumping action of the Hydra-Cell pump keeps the liquid in a more stable state for greater predictability and a more constant process. Peristaltic Pump Disadvantages Pulsing flow on discharge. Pulsation dampers required. Pump tube operates under stress leading to a consumable replacement part. Hydra-Cell Advantages Multiple diaphragm pump head ensures smooth discharge flow. Pulsation dampers not required on the majority of applications. Diaphragms operating in hydraulic balance under no stress leading to long life. Magnetic Drive Pump Disadvantages Cannot run dry without damage to the pump. Does not handle iron or scale particles well. Requires monitoring to ensure liquid flow. Designed to pump clean, low-viscosity liquids. Higher power requirements and energy costs. Can have a long horizontal footprint with higher acquisition and replacement costs. Hydra-Cell Advantages Seal-less design enables Hydra-Cell to run dry without damage, indefinitely. Seal-less pumping chamber and spring-loaded check valves can handle particulates. Ensures proper liquid flow without monitoring. Seal-less pumping chamber and spring-loaded check valves can handle particulates and abrasive fillers. Low-shear pumping action handles higher viscosity liquids. Smaller footprint compared to some magnetic drive pumps. More energy efficient. Easier to service. Lower acquisition, operating and replacement costs. 12

Hydra-Cell Materials of Construction As part of our Mass Customisation philosophy, every Hydra-Cell pump is built with manifolds, elastomeric materials, and valve assemblies using construction materials specified by the customer. Hydra- Cell distributors and factory representatives are readily available to assist customers in selecting the materials best suited to the process application. (The range of material choices depends on each pump model for example, models designed to operate at higher pressures are available with metallic pump heads only.) Manifolds Manifolds for Hydra-Cell pumps are available in a variety of materials to suit your process application. They are easy to replace and interchangeable to accommodate different liquids processed by the same pump. Special manifolds with a 2:1 dosing ratio are also available. (Consult factory.) Non-metallic Pump Heads Non-metallic pump heads are often used when a corrosive or aggressive liquid is being processed at lower pressures. Polypropylene PVDF Metallic Pump Heads Metallic pump heads can handle higher operating pressures. Hastelloy CW12MW or Stainless Steel is also selected for corrosion resistance and other properties. Brass Bronze Cast Iron (Nickel-plated) Duplex Alloy 2205 Super Duplex Alloy 2507 Hastelloy CW12MW 304 Stainless Steel 316L Stainless Steel 13 Diaphragms and O-rings Diaphragms and corresponding o-rings are available in several elastomeric materials. Aflas (used with PTFE O-ring) Butyl Buna-N EPDM (requires EPDM-compatible oil) FFKM FKM Neoprene PTFE

Valve Springs Elgiloy (Exceeds SST grade 316L) Hastelloy CW12MW 17-7 PH Stainless Steel 316L Stainless Steel Valve Spring Retainers Celcon Hastelloy CW12MW Nylon (Zytel) Polypropylene Valve Materials Hydra-Cell valve assemblies (seats, valves, springs, and retainers) are available in a variety of materials to suit your process application. Valve Seats Ceramic Hastelloy CW12MW Nitronic 50 Tungsten Carbide 17-4 PH Stainless Steel 316L Stainless Steel Valves Ceramic Hastelloy CW12MW Nitronic 50 Tungsten Carbide 17-4 PH Stainless Steel PVDF 17-7 PH Stainless Steel Registered trademarks of materials: Aflas Buna -N (Nitrile) Celcon Elgiloy Hastelloy CW12MW Kynar (PVDF) Mesamoll Neoprene Nitronic 50 Teflon (PTFE) Viton (FKM) Zytel (Nylon) Asahi Glass Co., Ltd. E.I. Du Pont de Nemours and Company, Inc. Celanese Company Elgiloy Limited Partnership Haynes International, Inc. Arkema, Inc. Lanxess Deutschland GmbH E.I. Du Pont de Nemours and Company, Inc. AK Steel Corporation E.I. Du Pont de Nemours and Company, Inc. DuPont Performance Elastomers, LLC E.I. Du Pont de Nemours and Company, Inc. 14

Hydra-Cell G Series Seal-less Pumps Hydra-Cell T Series Seal-less Pumps Hydra-Cell Q Series Seal-less Pumps Hydra-Cell P Series Seal-less Metering Pumps 15

Hydra-Cell Flow Capacities and Pressure Ratings G, T and Q Series Seal-less Pumps 350 300 T100 (High) Pressure: Bar 200 T100 (Med) Q155 (Med) 100 G04 G15 G17 G20 T100 (Low) Q155 (Low) 0 G03 G03MB G10 G12 G25 G35 0 5 10 20 40 80 160 320 640 Flow: Litres per minute G66 The graph above displays the maximum flow capacity at a given pressure for each model series. The table below lists the maximum flow capacity and maximum pressure capability of each model series. Please Note: Some models do not achieve maximum flow at maximum pressure. Refer to the individual model specifications in this section for precise flow and pressure capabilities by specific pump configuration. Model Maximum Capacity l/min Maximum Discharge Pressure bar Maximum Operating Temperature C 2 Non-Metallic 1 Metallic Non-Metallic Metallic Maximum Inlet Pressure bar G20 3.8 24 103 60 121 17 G03 11.7 24 103 60 121 17 G04 11.2 N/A 200 N/A 121 34 G10 33.4 24 103 60 121 17 G12 33.4 N/A 103 N/A 121 17 G15/17 58.7 N/A 172 N/A 121 34 G25 75.9 24 69 60 121 17 G35 138 N/A 103 N/A 121 34 G66 248 17 48 49 121 17 T100S 98 N/A 345 N/A 82 34 T100M 144 N/A 241 N/A 82 34 T100K 170 N/A 207 N/A 82 34 T100H 259 N/A 145 N/A 82 34 T100F 290 N/A 128 N/A 82 34 T100E 366 N/A 103 N/A 82 34 Q155E 595 N/A 103 N/A 82 34 Q155F 490 N/A 127 N/A 82 34 Q155H 421 N/A 144 N/A 82 34 Q155K 295 N/A 207 N/A 82 34 Q155M 253 N/A 241 N/A 82 34 1 24 bar maximum with PVDF (Kynar ) liquid end; 17 bar maximum with Polypropylene liquid end. 2 Consult factory for correct component selection for temperatures from 160 F (71 C) to 250 F (121 C). 16

Hydra-Cell Metering & Dosing Pumps ATEX / Explosive Areas Flow Capacities and Pressure Ratings 200 180 160 140 MT8 P300 G04 Pressure: Bar 120 100 80 G03/G13 G10 60 G25 40 P200 P400 G35 20 0 0 25 50 100 200 400 800 1600 3200 6400 Flow: Litres per hour Model Maximum Capacity l/hr Maximum Discharge Pressure bar Maximum Operating Temperature C 2 Maximum Inlet Pressure bar Non-Metallic 1 Metallic Non-Metallic Metallic 17 MT8 30 N/A 241 N/A 121 17 P200 102 24 103 60 121 17 P300 95 N/A 172 N/A 121 34 P400 305 24 69 60 121 17 G13 - M2H 462 24 103 60 121 17 G13 - M2M 462 24 60 60 121 17 G13 - M4L 230 24 20 60 121 17 G13 - M2L 462 24 20 60 121 17 G04 - M4H 226 N/A 172 N/A 121 34 G04 - M2M 452 N/A 150 N/A 121 34 G10 - M4H 732 24 103 60 121 17 G10 - M2M 1470 24 50 60 121 17 G10 - M4L 732 20 20 60 121 17 G10 - M2L 1470 20 20 60 121 17 G25 - M4L 2600 20 20 60 121 17 G25 - M4M 2600 24 60 60 121 17 G35 - M2L 6360 N/A 10 N/A 121 10 G35 - M4L 4800 N/A 30 N/A 121 17 1 24 bar maximum with PVDF (Kynar ) liquid end; 17 bar maximum with Polypropylene liquid end. 2 Consult factory for correct component selection for temperatures from 160 F (71 C) to 250 F (121 C).

Hydra-Cell Metering & Dosing Pumps Electronic Control Flow Capacities and Pressure Ratings 200 MT8 P300 G04 G15 Pressure: Bar 100 G03 P100 P200 P400 P500 P600 G10 G25 G35 0 0 300 600 1200 2400 4800 9600 Flow: Litres per hour Model Maximum Capacity l/hr Maximum Discharge Pressure bar Maximum Operating Temperature C 2 Maximum Inlet Pressure bar Non-Metallic 1 Metallic Non-Metallic Metallic MT8 30 N/A 241 N/A 121 17 P100 85 24 103 60 121 17 P200 255 24 103 60 121 17 P300 257 N/A 172 N/A 121 34 P400 766 24 69 60 121 17 P500 1244 N/A 172 N/A 121 34 P600 2808 24 69 60 121 17 G03 660 24 103 60 121 17 G04 660 N/A 172 N/A 121 34 G10 1800 24 69 60 121 17 G10 900 24 103 60 121 17 G15 2940 N/A 138 N/A 121 34 G15 2280 N/A 172 N/A 121 34 G25 4560 24 69 60 121 17 G35 8280 N/A 83 N/A 121 34 G35 3960 N/A 103 N/A 121 17 1 24 bar maximum with PVDF (Kynar ) liquid end; 17 bar maximum with Polypropylene liquid end. 2 Consult factory for correct component selection for temperatures from 160 F (71 C) to 250 F (121 C). 18

19 Notes

20

21

22

Partners in over 70 Countries Wanner Engineering - World Headquarters & Manufacturing Minneapolis USA t: (612) 332-5681 e: sales@wannereng.com Wanner Engineering Latin American Office t: +55 (11) 3565 4001 e: sales@wannereng.com Wanner Pumps Shanghai CHINA t: +86-21-6876 3700 e: sales@wannerpumps.com Wanner Pumps Kowloon HONG KONG t: +852 3428 6534 e: sales@wannerpumps.com Wanner International Hampshire UK t: +44 (0) 1252 816847 e: sales@wannerint.com Version 13. 11/16 www.hydra-cell.eu