FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Similar documents
PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

EXCa. Exhaust register

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

CRP. Commissioning damper, Ductwork Leakage Class 0

DIR. VARIZON Displacement unit with adjustable spread pattern. Quick guide

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

TBV - Terminal Unit. Halton TBV. Terminal Unit

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

Ceiling swirl diffusers

Ceiling swirl diffusers

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

DATASHEET PRODUCT CODE EXAMPLE:

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

Conical diffuser KHAA TECHNICAL DATA

ACTIVENT System. Specifications. Product code example ACTA

CTVK Supply air diffuser

KTI Supply air valve. Product Facts. Product code example. Quick Selection

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

Nozzle air diffuser DYSB

Slot diffusers, Round duct diffusers. IMP Klima

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

VARYCONTROL VAV Dual Duct Terminal Boxes

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers

Ventiduct nozzle ducts

ceiling swirl diffuser DQJ

Exhaust air diffuser HPKH + Plenum box ATTS

series RVV Variable flow rate controllers

SERENO

KGEB Exhaust valve. Specifications. Quick Selection. Product code example Exhaust valve KGEB-100-C Mounting ring KGEZ-01

Ventiduct nozzle ducts

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

2/6.1/EN/1. High Induction. Variable / Constant Volume Swirl Diffuser Types HIVV HICV

BLBd

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

ADRIATIC VF. Active climate beam with cooling, heating and ventilation QUICK FACTS

Fan - Powered Terminal Unit Series Flow

Ceiling swirl diffusers with perforated face plate

CornerAir. CornerAir. Active chilled beam

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Supply air diffusers RHKH and RHOH / Supply air units RHKB/RHOB (=RHKH/RHOH+ATTD)

Ceiling Swirl Diffuser DQJ

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

GDD - Supply Grille. Halton GDD. Supply Grille

CONSTANTFLOW Volume Flow Controllers

for suspended installation. Active climate beam with cooling, heating and ventilation

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

BRC

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

ALD. Sound attenuating exterior wall grille QUICK FACTS. Excellent noise attenuation A robust grille that withstands severe climatic conditions

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Swegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES

Casing Hot galvanised steel / Option: stainless steel EN (AISI316L) Reheat coil EN (AISI 304)

WGA Long throw nozzle grille

SDV Vane Swirl Diffusers

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

Room product for Swegon s WISE System for demand-controlled ventilation

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

Swegon PACIFIC. Integrated climate beam

Swegon PACIFIC. Integrated climate beam

Zest Iris Duct Dampers

ceiling swirl diffuser Model DQJA / DQJR

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

Ventilation grilles for installation into walls, sills or rectangular

Ceiling impulse diffuser Model PIL

Transcription:

Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable for airborne heating Can be used with the ALS commissioning box Cleanable Standard colour White RAL 9003 -- alternative standard colours -- Other colours upon request FALCON Ceiling AIR FLOW - SOUND PRESSURE ROOM (LpA) *) 2 db(a) db(a) 3 db(a) l/s m 3 /h l/s m 3 /h l/s m 3 /h 12 48 173 7 68 24 160 70 22 83 299 99 36 112 3 132 47 16 62 170 612 2 727 2 864 31 26 94 312 1123 370 1332 0 431 12 0 1818 90 2124 00 631 2272 743 267 87 3 FALCON Ceiling ALS 2 db(a) db(a) 3 db(a) l/s m 3 /h l/s m 3 /h l/s m 3 /h 12-12 24 86 34 122 44 18 160 12-160 34 122 46 166 66 237 160-4 194 68 24 9 342-82 29 378 1 8 31-31 12 2 76 0 31-0 7 24 882 32 1170 00 0-00 3 1116 37 1 16 The data for the FALCON C + commissioning box combination is specified for 0 Pa total pressure and for a horizontal distribution pattern. *) LpA = Sound pressure incl. A-filter with 4 db room attenuation and m2 room absorption area.

Contents Technical description... 3 Design... 3 Materials and finish... 3 Accessories... 3 Project design... 3 Installation... 3 Commissioning with the ALS commissioning box... 3 Maintenance... 3 Sizing... 4 Motor Properties... 4 FALCON C + ALS Horizontal... Air diffuser only Vertical... 6 FALCON C + ALS Vertical... 6 FALCON C Supply air... 7 Horizontal or vertical distribution pattern... 7 FALCON C with ALS Supply air... 8 Horizontal and vertical distribution pattern... 8 FALCON C with ALS Supply air... Vertical distribution pattern... Dimensions and weights... 12 Ordering key... 13 Specification text... 13 2 Swegon reserves the right to alter specifications. 183

Technical description Design The FALCON C consists of two parts: an outer cone with rubber ring sealed-fitted spigot connection on the sizes up to and including size 0 as well as an aerodynamically designed outlet cone. The inner cone is height-adjustable and removable. The inner cone can be set to a new position by hand or its setting can be changed by a motor. The FALCON C with electric motor is available in sizes 31, 0 and 00. The motor-actuated model has a longer spigot connection. See the dimension table and Figure 6. Materials and finish The entire air diffuser is made of sheet steel and its interior and exterior surfaces are painted in our standard white colour: RAL 9003/NCS S 000-N. The air diffuser is also available in optional standard colours: RAL 7037 dusty grey, RAL 9006 white aluminium, RAL 900 jet black, RAL 9007 grey aluminium and RAL 90. Accessories Commissioning box: ALS. Made of galvanised sheet steel. The box contains a removable commissioning damper, fixed measurement tapping and sound absorbent insulation covered by a reinforced surface layer, rated to Fire resistance class B-s1,d0 conforming to EN ISO 1192-2. Tightness class C on the housing according to SS-EN 12237 and VVS/AMA 12. Controller for resetting motor-actuated air diffusers: VHC. The controller resets motor-actuated (24 V) air diffusers, which are designed for supply air below room temperature and above room temperature. The controlling parameter is the temperature difference between the supply air and the room air. See separate product datasheet for the VHC at www.swegon. com. Measurement accuracy and requirement on straight duct before the commisioning box, see Figure 1. The requirements of straigh duct depends on the type of disturbance before the commissioning box. Figure 1 shows a bend, a dimensional change and a T-piece. Other types of disturbances requires at least 2xD straight (D = connection dimension) for measurement accuracy of ± % of the flow. The K-factor (COP) is specified on the product s identification label. K-factors can also be found in the relevant commissioning instructions at www.swegon.com. Maintenance Clean the air diffuser if needed with lukewarm water and dishwashing detergent added. The duct system is accessible without the need for tools. The cone package can be dismantled by screwing out the plastic screws on the inner side of the outer cone. If an ALS commissioning box is used, move the air distribution plate out of the way and turn the damper unit out of its holder with a simple twist of the hand. Project design For airborne heating systems, the distribution pattern should be calculated according to computer-calculated values. Use our ProAir air diffuser selection computer program that is available at www.swegon.com. The air diffuser is available as from size 31 and upward with motorised actuation of the cone position in order to via thermostat, or other external switch, control from horizontal to vertical air diffusion or vice versa. Installation Secure the inlet spigot to the connecting duct using blind rivets. If an ALS commissioning box is used, the sleeve coupling between the ALS and the FALCON C can be lengthened using an ordinary circular duct of up to 00 mm without having to lengthen the measuring tubes and damper adjustment cords. See Figure 1. Commissioning with the ALS commissioning box Commissioning should be carried out with the diffuser face mounted. Pull the measuring tubes and damper adjustment cords out of the air diffuser through the gap. Lockable damper setting. 0xD / ±% 0xD / ±% 2xD / ±% Figure 1. Installation. Commissioning. 183 Swegon reserves the right to alter specifications. 3

Wiring diagram Figure 2. Wiring diagram for the FALCON C with motor 2-point motor positioning control. The switch is not included. 1 2 3 L1 N Sizing The specified sound levels db(a) are applicable to rooms with an equivalent sound absorption area of m 2. Throw length 1 0.2 is measured under isothermal discharge conditions. The recommended max. permissible temperature below room temperature is K. The horizontal distribution pattern is specified with the inner cone package set to its lower position. See the dimension drawing. The vertical distribution pattern is specified with the inner cone package set to its upper position. See the dimension drawing. For calculating the width of the air stream, air velocities in the occupied zone or sound levels in rooms with other dimensions, please refer to our web calculation softwares available for download at www.swegon. com. Motor Properties Motor Supply voltage Power consumption Delay time LH24A *) 24 V AC 0/60 Hz 3 VA s LH2A **) 2 V AC 0/60 Hz VA s *) Standard, stocked motor, can be connected to VHC controller. **) Non-stocked motor. Figure 3. Wiring diagram for the FALCON C with motor 3-point motor positioning control. The switch is not included. Figure 4. The wiring diagram shows the connections with the Belimo damper motor against the VHC. NOTE! Only available with 24 V AC power supply. Key to Figure 4. 1 = VHC controller 2 = Duct temperature sensor (DT) 3 = Room temperature sensor (RT) 4 = Setting the switch-over temperature 4 Swegon reserves the right to alter specifications. 183

Acoustic data FALCON C Supply air Air diffuser only Horizontal Sound power level, L w (db) Table K OK Mid-frequency (Octave band) Hz 12 11 8 0 - -11-21 -27 160 3 12 7 1-4 -8-14 -23 6 13 7 1-4 -8-1 -22 9 13 6 1-2 -9-19 -27 31 12 16 9 0-3 -11-17 -2 0 14 12 8 1-3 - -14-22 00 1 12 7 1-2 -8-1 -23 Sound attenuation DL(dB) Table DL Mid-frequency (Octave band) Hz 12 21 16 12 7 2 0 0 0 160 18 14 1 0 0 0 17 13 9 4 0 0 0 0 18 11 7 3 0 0 0 0 31 6 2 0 0 0 0 0 19 9 1 0 0 0 0 00 12 7 3 1 0 0 0 0 FALCON C + ALS Horizontal Sound power level, L w (db) Table K OK Mid-frequency (Octave band) Hz 12 3 7-1 -2-7 -13-18 160 9 9 8-2 -4-6 -13-18 7 11 8-2 -4-7 -13-18 4 11 6-2 -3-7 -13-16 31 6 11-2 -1-7 -13-18 0 8 11 4 0-2 -6-12 -19 00 9 11 3 1-1 -8-14 -21 Sound attenuation DL(dB) Table DL Mid-frequency (Octave band) Hz 12 21 16 9 17 23 16 11 13 160 22 14 17 19 12 12 17 11 8 16 18 12 11 11 14 8 8 16 17 12 12 13 31 13 6 7 19 14 13 0 13 8 14 11 11 12 00 8 4 6 12 9 183 Swegon reserves the right to alter specifications.

Air diffuser only Vertical Sound power level, L w (db) Table K OK Mid-frequency (Octave band) Hz 12-2 8 0-6 -7-1 -2 160-6 7 7 2-4 -6-13 -26-2 7 1-3 - -14-23 -2 9 7 1-2 -7-17 -28 31 4 13 9 1-2 - - -2 0 7 8 2-3 -8-14 -22 00 9 7 1-2 -7-1 -24 Sound attenuation DL(dB) Table DL Mid-frequency (Octave band) Hz 12 21 16 12 7 2 0 0 0 160 18 14 1 0 0 0 17 13 9 4 0 0 0 0 18 11 7 3 0 0 0 0 31 6 2 0 0 0 0 0 19 9 1 0 0 0 0 00 12 7 3 1 0 0 0 0 FALCON C + ALS Vertical Sound power level, L w (db) Table K OK Mid-frequency (Octave band) Hz 12 7-2 - -8-14 -18 160 8 11 11-2 -8 - -1-19 6 14 11-3 -8 - -16-19 14-3 -7 - -18-19 31 9 14 8-4 -4-8 -16-19 0 11 1 7-2 - -11-16 - 00 12 1 7-1 -3-11 -18-2 Sound attenuation DL (db) Table DL Mid-frequency (Octave band) Hz 12 21 16 9 17 23 16 11 13 160 22 14 17 19 12 12 17 11 8 16 18 12 11 11 14 8 8 16 17 12 12 13 31 13 6 7 19 14 13 0 13 8 14 11 11 12 00 8 4 6 12 9 6 Swegon reserves the right to alter specifications. 183

Sizing diagram FALCON C Supply air Horizontal or vertical distribution pattern The diagrams provide data for a FALCON C placed in a ceiling. The diagrams should not be used for commissioning. The db(a) values are for rooms with normal acoustic absorption (4 db room attenuation). The db(c) value is normally 6-9 db higher than the db(a) value. FALCON C 12, Horizontal 12 160 FALCON C 12, Vertical 12 160 0 2 db(a) 3 0 2 db(a) 3 160 4 3 0 l/s 0 0 00 m 3 /h 160 4 0 l/s 0 0 m 3 /h 12 2 3 4 12 3 4 FALCON C 00, Horizontal FALCON C 00, Vertical 0 2 db(a) 3 31 0 00 0 2 db(a) 3 31 0 00 00 0 31 4 3 0 0 00 l/s 0 0 00 0 0 m 3 /h 00 0 31 4 0 0 l/s 00 0 0 00 0 m 3 /h m l 0,2 0 183 Swegon reserves the right to alter specifications. 7

FALCON C with ALS Supply air Horizontal and vertical distribution pattern Airflow Pressure drop Sound level Throw length The diagrams provide data for a FALCON C placed in a ceiling. The diagrams should not be used for commissioning. = Min. airflow required for obtaining necessary commissioning pressure. The db(a) values are for rooms with normal acoustic absorption (4 db room attenuation). The db(c) value is normally 6-9 db higher than the db(a) value. FALCON C 12 + ALS -12, Horizontal 00 0 0 2 db(a) 3 % FALCON C 160 + ALS 12-160, Horizontal 00 0 0 2 db(a) 3 % 0 0 0 l/s 0 m 3 /h 0 l/s 0 m 3 /h 1 2 3 4 1 2 3 4 FALCON C + ALS 160-, Horizontal 00 0 0 db(a) 3 % FALCON C + ALS -, Horizontal 00 0 0 db(a) 3 % 2 2 0 0 0 l/s 0 l/s 0 0 0 00 m 3 /h 0 0 00 m 3 /h 2 3 4 m l 0,2 2 3 4 8 Swegon reserves the right to alter specifications. 183

FALCON C 31 + ALS -31, Horizontal 0 0 0 2 db(a) 3 % FALCON C 0 + ALS 31-0, Horizontal 0 0 2 db(a) 3 % 0 0 0 l/s 00 0 0 00 0 m 3 /h 0 0 00 l/s 0 0 00 0 0 m 3 /h 2 3 4 3 4 l 0,2 m FALCON C 00 + ALS 0-00, Horizontal 0 2 db(a) 3 % 0 0 00 l/s 0 0 00 0 0 m 3 /h 3 4 l 0,2 m 183 Swegon reserves the right to alter specifications. 9

FALCON C with ALS Supply air Vertical distribution pattern Airflow Pressure drop Sound level Throw length The diagrams should not be used for commissioning. = Min. airflow required for obtaining sufficient commissioning pressure. The db(a) values are for rooms with normal acoustic absorption (4 db room attenuation). The db(c) value is normally 6-9 db higher than the db(a) value. FALCON C 12 + ALS -12, Vertical 00 0 0 2 db(a) 3 % FALCON C 160 + ALS 12-160, Vertical 00 0 0 2 db(a) 3 % 0 0 0 l/s 0 m 3 /h 0 l/s 0 m 3 /h 2 3 4 2 3 4 FALCON C + ALS 160-, Vertical 00 0 0 2 db(a) 3 % FALCON C + ALS -, Vertical 00 0 0 2 db(a) 3 % 0 0 0 l/s 0 0 00 m 3 /h 0 l/s 0 0 0 00 m 3 /h 4 l 0,2 m Swegon reserves the right to alter specifications. 183

FALCON C 31 + ALS -31, Vertical 00 0 0 0 2 db(a) 3 % FALCON C 0 + ALS 31-0, Vertical 0 0 2 db(a) 3 % 0 0 l/s 0 0 0 00 0 m 3 /h 0 0 00 l/s 0 0 00 0 0 m 3 /h 0 l 0,2 m FALCON C 00 + ALS 0-00, Vertical 0 2 db(a) 3 % 0 0 00 l/s 0 0 00 0 0 m 3 /h 0 183 Swegon reserves the right to alter specifications. 11

Dimensions and weights FALCON C ØA Ød ØJ F F1 G H L L1 Weight (kg) 12 124 270 7 4 9, 1,0 160 19 270 6 4 13 1,0 378 199 3 7 4 14 13 1, 477 249 4 9 4 17 16 2,2 31 91 314 1 4 32 4 3,4 0 703 399 6 12 4 24 24 3 4,1 00 83 499 780 13 4 3 4 8,0 of the opening = ØJ FALCON C + ALS ØA B C ØD E K M N P Weight (kg) 12 282 217 99 23 80 180 270 3,0 160 342 22 124 249 80 4 112 31 3,7 378 4 288 19 292 239 1 37,0 477 04 332 199 346 11 279 46 7,4 31 91 622 388 249 421 1 3 17 7 11,4 0 703 767 488 314 489 17 0 212 712 1, 00 83 887 88 399 618 19 280 79 18, CL = Centre line F F1 H G Figure 7. FALCON C, cone positions. G = Lower position horizontal diffusion H = Upper position vertical diffusion Figure. FALCON C, hand-actuated. P N M Figure 6. FALCON C, motor-actuated. Figure 8. FALCON C + ALS. CL = Centerline 12 Swegon reserves the right to alter specifications. 183

Ordering key Product Circular ceiling air diffuser for supply air Version: Hand-actuated: 1 Motor-actuated: 2 (31, 0, 00) : 12, 160,,, 31, 0, 00 Accessories FALCON C a -a -bbb Commissioning box ALS d -aaa bbb Version For FALCON C 12 160 31 0 00 ALS -12 12-160 160- - -31 31-0 0-00 Specification text SD XX Swegons circular type FALCON C multi-cone air diffuser for ceiling mounting with ALS commissioning box, with the following functions: Adjustable horizontal/vertical distribution pattern White powder paint sprayed and baked finish, RAL 9003/NCS S 000-N Cleanable ALS commissioning box with removable commissioning damper with lockable blade position, measuring method with low systematic error and lined inside with sound absorbing material covered with reinforced surface layer : FALCON Ca a bbb + ALSd aaa-bbb xx items Control unit VHC a Version 183 Swegon reserves the right to alter specifications. 13