HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

Similar documents
HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

HANDBOOK PIPING ACCESSORIES. Ed PIPING ACCESSORIES AT-ED 01/ ENG 1

HANDBOOK SOLENOID VALVE FOR REFRIGERATING SYSTEMS AND INDUSTRIAL PURPOSES. ed. 001-VS-ENG 1

HANDBOOK EXPANSION VALVES. Ed EXPANSION VALVES VE-ED 01/ ENG 1

HANDBOOK OIL CONTROL SYSTEMS. Ed OIL CONTROL SYSTEMS CO-ED 01/ ENG 1

HERMETIC VALVES APPLICATIONS

HERMETIC VALVES. 118

HANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

Solenoid valve for R410A and R744 Types EVR 2 - EVR 6 and EVRH 10 - EVRH 40

Replaceable solid cores filter driers type CSR

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves Type EVU for fluorinated refrigerants

Solenoid valve Types EVR 2 EVR 40 NC/NO

Crankcase pressure regulator Type KVL

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.

Solenoid valves Type EVU

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Crankcase pressure regulator Type KVL

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

Capacity regulators (hot gas bypass) PMC and CVC

Electrical Control Valves

quality products for refrigeration and air conditioning products suitable for CFC, HCFC and HFC 2006 release PRODUCT HANDBOOK

Solenoid valves EVRA and EVRAT

Solenoid valves type EVR 2 40 NC / NO

Reliable season change

Modulating liquid level regulators, direct-controlled SV 1 and SV 3

Electrical Control Valves Series EX4, EX5, EX6, EX7 & EX8

(S)PORT - (S)PORT-II Evaporator Pressure Regulators

Solenoid valves. Solenoid valves, type PKVD Solenoid valves, type EVR NC / NO

Technical Data Sheet

Crankcase pressure regulator Type KVL

ELIMINATOR Hermetic bi-flow filter drier Types DMB and DCB

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

ELIMINATOR Hermetic filter drier Types DML and DCL

Sporlan V-Series Ruby Seat Solenoid Valves

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

CCMT - Electrically operated valves for transcritical and subcritical CO2

HCYCT (non adjustable) / HCYCTR (adjustable)

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

Pressure control valve Type KDC

Reliable season change

PRODUCT DATA HDF SERIES Solenoid Valve

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

Solenoid coil for control in potentially explosive areas Type BZ

YFC. Limit switch. Ex d. 24 operating head types

Electronically operated expansion valve for CO 2 Type AKVH

STAINLESS STEEL ATEX 2/2 SOLENOID VALVE SPU220-X NF

Pressure operated water valve Type WVFX and WVS

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]

Danfoss Saginomiya 4 - Way Reversing Valves

Ex m Solenoid Operator Type 0519

VE4000 & VE5000 SERIES

Solenoid valves type EVRA 3 to 40 and EVRAT 10 to 20

Anti-acid filter driers DCY

Electric expansion valve Type ETS ETS 400

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical.

Operating Instruction Modulating refrigerant valves with magnetic actuator, PS45 Hermetically sealed, for safety refrigerants

3/2-Way Zone-Drain-Valves VDHT 2E, VDHT 15E and VDHT 15EC

Electric Expansion Valve Type AKVO 10

Operating instruction Refrigerant Valves PS45

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Solenoid Valves. Product Information. It s all at Albion

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

EX4 / EX5 / EX6 / EX7 / EX8 Electrical Control Valves

Pilot-operated servo valve Type ICS

SCY. Discharge line mufflers Refrigeration & Climate Components Solutions. n Applications

BUTTERFLY VALVE WITH ADA PNEUMATIC ACTUATOR

Pressure and temperature regulators, type PM, and pilot valves

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Pilot-operated servo valve Type ICS

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

ON/OFF zone valves AMZ 112, AMZ 113

Servo-operated 2/2-way solenoid valves Type EV220A

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

STAINLESS STEEL ATEX 2/2 SOLENOID VALVE SPU225-X NF

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

AHRI Standard 1371 (SI) 2017 Standard for Performance Rating of Electronic Expansion Valves

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

XV7.2KX Variable Speed Drive Compressor R600a V 50/60Hz

FlowCon SH mm. Adjustable Dynamic Self Balancing Valve SPECIFICATIONS

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT

Features PNEUMAT IC VALVES. Pneumatic valves Vip - Pneumatic coaxial valve GENERAL FEATURES CONTROL MEDIA OPERATING MEDIA

Our new range of electromechanical pressure switches with fixed setting are compact, light and easy to install.

Operating instructions Solenoid interlock EX-AZM About this document. Content

The precise step to take

Pilot-operated servo valve Type ICS

Centrifugal fan with highly efficient EC drive motor

Pilot Controlled Servo Valves ICS

Assisted lift operated 2/2-way solenoid valves Type EV251B

ELIMINATOR Hermetic filter drier Types DCL and DML

Transcription:

HANDBOOK Ed. 2017 1

CHAPTER 5 NORMALLY-CLOSED FOR REFRIGERATION PLANTS THAT USE HC REFRIGERANTS APPLICATION The solenoid valves illustrated in this chapter have been developed by Castel for all those refrigeration applications that use the following HC refrigeration fluids: R290, R600, R600a, belonging to Group 1, defined in Article 13, Chapter 1, Point (a) of Directive 2014/68/EU, with reference to EC Regulation No. 1272/2008. The solenoid valves with an N suffix (1028N, 1068N, 1078N, 1079N, 1098N, 1099N) must be employed only in refrigeration systems located in areas not classified as at risk of explosion, according to the definition in Annex I of Directive 1999/92/EC. The solenoid valves with an EX suffix (1028EX, 1068EX, 1078EX, 1079EX, 1098EX, 1099EX) comply with the European Standard EN 13463-1:2009 and, therefore, comply with the ESR of Directive 2014/34/ EU ATEX. This equipment is suitable for use on refrigeration systems located in areas classified as Zone 2 risk of explosion, according to the definition in Annex I of Directive 1999/92/EC. CAUTION!: The solenoid valves in this chapter cannot be used with mineral oils or alkylbenzene oils. OPERATION The valves listed in this chapter are normally closed valves (NC). This means that when the coil is not energised, the plunger closes the fluid flow. When the coil is energised, the plunger opens the valve seat connecting the inlet to the outlet. All valves with an N suffix are sold in the version without coil (with the S suffix), and in the version with series 9300, type HF2 - FAST LOCK coils (A6 suffix with coil 9300/RA6-220/230 VAC). All valves with an EX suffix are sold only in the version with coil series 9100EX (A6 suffix with coil, 9100EX-220/230 VAC, ATEX certified). The valves series 1028N and 1028EX are direct acting valves. Their operation depends only on the magnetic field produced by the current flow into the coil. Opening/closing of main valve seat, the only seat, is directly controlled by the mobile plunger. These valves can work with zero pressure differential. Valves 1068N, 1068EX, 1078N, 1078EX, 1079N, 1079EX, 1098N/7, 1098EX/7, 1099N/9, and 1099EX/9 are pilotoperated diaphragm solenoid valves. Their operation depends not only on the magnetic field produced by the current flow into the coil, but also on a minimum inlet pressure, which is necessary to: open the diaphragm and keep it lifted off the main opening close the diaphragm and ensure the tightness on the main opening Opening/closing of main valve seat is controlled by the diaphragm while opening/closing of pilot seat is controlled by the mobile plunger of the coil. These valves cannot work with zero differential pressure. The valves 1098N/9, 1098EX/9, 1099N/11, and 1099EX/11 are pilot-operated piston solenoid valves. Their operation depends not only on the magnetic field produced by the current flow into the coil, but also on a minimum inlet pressure, which is necessary to: 36

open the piston and keep it lifted off the main opening close the piston and ensure the tightness on the main opening Opening/closing of main valve seat is controlled by the piston, while opening/closing of pilot seat is controlled by the mobile plunger of the coil. These valves cannot work with zero differential pressure. CONSTRUCTION The main parts of the valves are constructed with the following materials: Hot forged brass EN 12420 CW 617N for body and cover Copper tube EN 12735-1 Cu-DHP for solder connections Austenitic stainless steel EN 10088-2 1.4303 for enclosure where the plunger moves Ferritic stainless steel EN 10088-3 1.4105 for the plunger Austenitic stainless steel EN ISO 3506 A2-70 for tightening screws between body and cover. Hydrogenated nitrile butadiene rubber (HNBR) for outlet seal gaskets P.T.F.E. for seat gaskets All solenoid valves with an EX suffix are also equipped with: Identification label for compliance of the valve to the ATEX Directive. Operating instructions regarding installation of the valve in areas classified as at risk of explosion. Operating instructions regarding installation of the coil in areas classified as at risk of explosion. INSTALLATION The valves series 1028N, 1028EX, 1068N, 1068EX, 1078N, 1078EX, 1079N, 1079EX, 1098N, 1098EX, 1099N, and 1099EX can be installed on the three main branches of a system (hot gas line, liquid line, and suction line), while respecting the limits of use and the capacities indicated in TABLE 18. TABLE 16 shows the following functional characteristics of a solenoid valve: Connections PS: maximum allowable pressure TS: maximum / minimum allowable temperature Kv: discharge factor minopd: minimum Opening Pressure Differential. This is the minimum pressure differential between inlet and outlet at which a pilot-operated solenoid valve can open and stay opened or close and maintain the seal. MOPD: maximum Opening Pressure Differential according to AHRI STANDARD 760 : 2014. This is the maximum pressure differential between inlet and outlet at which a solenoid valve can open. Before connecting the valve to the pipe, it is advisable to make sure that the refrigerating system is clean. In fact, valves with P.T.F.E. gaskets, and particularly piston valves, are sensitive to dirt and debris. Furthermore, check that the flow direction in the pipe corresponds to the arrow stamped on the valve body. All the valves can be mounted in any position so long as the coil does not point downwards. The brazing of valves with solder connections should be carried out with care, using a low melting point filler material. It is not necessary to disassemble the valves before brazing, but it is important to avoid direct contact between the torch flame and the valve body, which could be damaged and compromise the proper functioning of the valve. Before connecting a valve to the electrical system, be sure that the line voltage and frequency correspond to the values marked on the coil. N.B.: Product suitable for hydrocarbon refrigerants The products in this chapter can be used with HC refrigerants classified as flammable fluids and that are in Safety Group A3 according to Standard EN 378-1:2016. These products must be used exclusively in refrigeration systems that comply with the current regulations for flammable refrigerant fluids (series EN 60335). Installation, maintenance and repair operations must be performed only by authorized personnel, qualified to work on flammable refrigeration systems. Note: In the specific case of solenoid valves with an EX suffix, the personnel must carefully follow the operating instructions provided in the packaging of said valves. TRACEABILITY Direct action valves in series 1028N are identified by laser marking on the valve enclosure of the mobile plunger. This marking includes the following data: valve code, refrigerants, PS, TS, and production lot. The pilot-operated diaphragm and piston solenoid valves in series 1068N, 1078N, 1079N, 1098N, and 1099N are identified by a plastic label fit on the valve enclosure of the mobile plunger. This label includes the following data: valve code, refrigerants, PS, TS, and production lot. The direct action valves in series 1028EX and the pilotoperated diaphragm and piston solenoid valves in series 1068EX, 1078EX, 1079EX, 1098EX, and 1099EX are identified by a plastic label fit on the valve enclosure of the mobile plunger, below the coil. This label provides the following information: valve code, PS, TA, type of ATEX certification, ATEX certification file number. 37

TABLE 16: General characteristics of NC valves with ODS connections, for HC (R290, R600, R600a) Operating Principles Catalogue Number ATEX No compliance ATEX Compliance for use in EX Zone 2 Connections ODS Ø [in.] Ø [mm] Seat size nominal Ø [mm] Kv Factor [m 3 /h] 1028N/2# 1028EX/2A6 1/4" 2,2 0,15 min OPD Opening Pressure Differential [bar] 9100 9100EX 9110 9110EX 9300 (AC) MOPD coil series 9160 (AC) 9120 9320 (AC) PS [bar] 9120 9320 (DC) TS [ C] min. max. TA [ C] min. (1) max. Risk Category according to PED Recast Direct Acting 1028N/2#.E 1028EX/2A6.E 1/4" 1028N/3# 1028EX/3A6 3/8" 3 0,23 0 21 28 35 21 45 40 +130 40 +50 Art. 4.3 1028N/M10# 1028EX/M10A6 10 1068N/3# 1068EX/3A6 3/8" 1068N/M10# 1068EX/M10A6 10 1068N/M12# 1068EX/M12A6 12 6,5 0,80 18 1068N/4# 1068EX/4A6 1/2" Diaphragm Pilot Operated 1078N/M12# 1078EX/M12A6 12 1078N/4# 1078EX/4A6 1/2" 1078N/5# 1078EX/5A6 5/8" 16 1079N/7# 1079EX/7A6 7/8" 22 12,5 2,20 2,61 0,05 21 28 35 13 45 40 +120 40 +50 Art. 4.3 1098N/5# 1098EX/5A6 5/8" 16 3,80 1098N/6# 1098EX/6A6 3/4" 4,80 16,5 1098N/7# 1098EX/7A6 7/8" 22 5,70 1099N/9# 1099EX/9A6 1.1/8" 10 Piston Pilot Operated 1078N/9# 1078EX/9A6 1.1/8" 1079N/11# 1079EX/11A6 1.3/8" 35 1098N/9# 1098EX/9A6 1.1/8" 1099N/11# 1099EX/11A6 1.3/8" 35 # = S, A6 (3) Check TA min of the chosen coil 25,5 10 13 25 10 0,1 21 28 35 18 45 40 +120 40 +50 Art. 4.3 38

Operating Principles Direct Acting Diaphragm Piston TABLE 17: Dimensions and weights of NC valves for HC, with 9300 coils (1) 1028N/2# Catalogue Number 1028EX/2A6 Dimensions [mm] H 1 H 2 H 3 L 1 L 2 Q 1028N/2#.E 1028EX/2A6.E 350 75 62,5 34 125 52 1028N/3# 1028EX/3A6 365 1028N/M10# 1028EX/M10A6 365 1068N/3# 1068EX/3A6 1068N/M10# 1068EX/M10A6 111 395 82 69,5 40 1068N/M12# 1068EX/M12A6 127 420 1068N/4# 1068EX/4A6 127 420 1078N/M12# 1078EX/M12A6 1078N/4# 1078EX/4A6 127 680 91 75 47 45 1078N/5# 1078EX/5A6 175 775 52 1079N/7# 1079EX/7A6 190 765 1098N/5# 1098EX/5A6 1098N/6# 1098EX/6A6 175 1185 106 78 50 57 1098N/7# 1098EX/7A6 180 1170 1099N/9# 1099EX/9A6 216 1225 1078N/9# 1078EX/9A6 250 2565 115 96 72 80 1079N/11# 1079EX/11A6 292 2620 1098N/9# 1098EX/9A6 235 2050 157 127 99 52 60 1099N/11# 1099EX/11A6 277 2130 111 127 175 Weight [g] 350 400 690 995 (1) : With coil 9320 the dimension L 2 is equal to 64 mm and theweights must be increased of 500 g. 39

Operating Principles Direct Acting Diaphragm Piston TABLE 18: Refrigerant flow capacity of NC valves for HC [kw] Catalogue Number 1028N/2# 1028EX/2A6 3,06 3,59 3,18 1028N/2#.E 1028N/3# 1028N/M10# 1068N/3# 1068N/M10# 1068N/M12# 1068N/4# 1078N/M12# 1078N/4# 1078N/5# 1079N/7# 1028EX/2A6.E 1028EX/3A6 1028EX/M10A6 1068EX/3A6 1068EX/M10A6 1068EX/M12A6 1068EX/4A6 1078EX/M12A6 1078EX/4A6 1078EX/5A6 1079EX/7A6 Liquid line Suction line Hot Gas line R290 R600 R600a R290 R600 R600a R290 R600 R600a 1,91 0,97 1,12 4,69 5,50 4,88 2,93 1,49 1,71 16,3 19,1 17,0 2,44 1,03 1,26 10,2 5,2 6,0 44,8 52,6 46,6 6,71 2,84 3,48 28,1 14,2 16,4 53,2 62,4 55,3 7,96 3,37 4,12 33,3 16,9 19,4 1098N/5# 1098EX/5A6 77,4 90,8 80,6 11,6 4,9 6,0 48,5 24,5 28,3 1098N/6# 1098EX/6A6 97,8 114,7 101,8 14,6 6,2 7,6 61,2 31,0 35,7 1098N/7# 1099N/9# 1078N/9# 1079N/11# 1098N/9# 1099N/11# 1098EX/7A6 1099EX/9A6 1078EX/9A6 1079EX/11A6 1098EX/9A6 1099EX/11A6 116,2 136,2 120,8 17,4 7,4 9,0 72,7 36,8 42,4 203,8 239,0 212,0 30,5 12,9 15,8 127,6 64,6 74,4 203,8 239,0 212,0 30,5 12,9 15,8 127,6 64,6 74,4 Standard rating conditions according to AHRI Standard 760-2007 Temperature leaving evaporator 50 F (9,9 C) Condensing temperature 110 F (43,3 C) Evaporator superheating 10 R (5,5 K) Liquid temperature 100 F (37,8 C) Suction line temperature 65 F (18,3 C) Subcooling 10 R (5,5 K) Suction superheating 15 R (8,4 K) Evaporating temperature 40 F (4,4 C) Discharge temperature 160 F (71,1 C) 40

www.castel.it Castel can accept no responsibility for any errors or changes in the catalogues, handbooks, brochures and other printed material. Castel reserves the right to make changes and improvements to its products without notice. All trademarks mentioned are the property of their respective owners. The name and Castel logotype are registered trademarks of Castel Srl. All rights reserved. ed. 76 001-VS-ENG Castel Srl - Via Provinciale 2-4 - 20060 Pessano con Bornago - MI