XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

Similar documents
XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

XACA871 pendant control station XAC-A - 8 pushbuttons

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

K50H004UP cam changeover switch - 4-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

Limit switches 3. Page 92. Page 92

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

K63F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

XACA871 pendant control station XAC-A - 8 pushbuttons

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications XCR. b XCR

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Limit switches. Steel roller plunger. Metal end plunger with elastomer boot 4.6(P) mm

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

Compact plastic limit switches with positive opening mechanism

Miniaturized limit switches

Compact plastic limit switches with positive opening mechanism

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

Components for safety applications

Pendant control stations 6

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

FL series position switches

Safety detection solutions

Limit Switch - Prewired Type Metal Body

Safety rope switches with reset for emergency stop

Position switches FD series

Switches with manual reset

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

LK Position Switches TECHNICAL DATASHEET.

Presentation. Limit switches. b XC2J. v With head for linear movement (plunger) with 1 cable entry. v With head for rotary movement (lever)

PRODUCT SPECIFICATION. Foot Switches. Series.

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Pre wired limit switches

Limit Switches - Limit Type (PS21L) Metal Body IP66

Position switches FR series

Safety rope switch with reset for emergency stop

Position switches FR series

Limit switches Osiswitch Classic For hoisting and materials handling applications, type XCR Complete switches with 1 cable entry

BMI0703P17F servo motor BMI 3-phase - keyed IP54 multiturn p/t x 4096 t - brake

Microswitches M series

Limit Switches - Limit Type Plastic Body IP65

Limit Switches - Limit Type Plastic Body IP65

Safety switches for hinged doors

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Screw limit switches XRBA and XR2. Catalogue

BMH1001P17F2A servo motor BMH Nm rpm - keyed shaft - with brake - IP54

BMH0701P07F2A servo motor BMH Nm rpm - untapped shaft - with brake - IP54

Rotary limit switches FCR FGR series

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

VW3A4552 line/motor choke - 4 mh - 10 A - 3 phases - 65 W - for variable speed drive

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Safety switches for hinges

Safety switches with separate actuator

Position switches FC series

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Prewired position switches FF series

Safety Limit Switch

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Standard Interlock Safety Switches

Safety switches for hinged doors

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

AF40... AF96 3-pole contactors Technical data

BSH1001P21F1A AC servo motor BSH N.m rpm - untapped shaft - with brake - IP65

FOOT SWITCHES

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Safety rope switch without reset for simple stop

BSH0702T22A2A AC servo motor BSH N.m rpm - untapped shaft - without brake - IP65

Prewired position switches FF series

Transcription:

Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 47.90 USD Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device short name XCKP Sensor design Compact Body type Fixed Head type Rotary head Material Plastic Body material Plastic Head material Zamak Fixing mode By the body Movement of operating head Rotary Type of operator Spring return roller lever thermoplastic (variable length) Type of approach Lateral approach 2 directions Number of poles 2 Contacts type and composition 1 NC + 1 NO Contact operation Snap action Complementary Switch actuation By 30 cam Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² Cable entry 1 entry tapped for M16 x 1.5 cable gland, cable outer diameter: 0.16...0.31 in (4...8 mm) Contacts insulation form Zb Positive opening With Positive opening minimum torque 2.21 lbf.in (0.25 N.m) Minimum torque for tripping 0.88 lbf.in (0.1 N.m) Mar 28, 2019 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Maximum actuation speed Repeat accuracy Contact code designation 4.92 ft/s (1.5 m/s) 0.1 mm on the tripping points with 1 million operating cycles A300, AC-15 (Ue = 240 V, Ie = 3 A), Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1 appendix A [Ui] rated insulation voltage 300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to IEC 60947-1 300 V conforming to UL 508 Resistance across terminals <= 25 MOhm conforming to IEC 60255-7 category 3 [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60664 6 kv conforming to IEC 60947-1 Short-circuit protection Electrical durability Mechanical durability Width Height Depth Product weight Terminals description ISO n 1 10 A by gg cartridge fuse 5000000 cycles, DC-13, 120 V, 4 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 24 V, 10 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, 48 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 10000000 cycles 1.22 in (31 mm) 2.56 in (65 mm) 1.18 in (30 mm) 0.32 lb(us) (0.145 kg) (13-14)NO (21-22)NC Environment Shock resistance 50 gn (duration = 11 ms) conforming to IEC 60068-2-27 Vibration resistance 25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 IP degree of protection IP66 conforming to IEC 60529 IP67 conforming to IEC 60529 IK degree of protection IK04 conforming to EN 50102 Electrical shock protection class Class II conforming to IEC 61140 Class II conforming to NF C 20-030 Ambient air temperature for operation Ambient air temperature for storage Protective treatment Product certifications -13...158 F (-25...70 C) -40...158 F (-40...70 C) TC CCC CSA UL Standards EN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14 Ordering and shipping details Category 22418 - LIMIT SWITCH,IEC,XCKP&XCKT Discount Schedule T GTIN 00785901912903 Nbr. of units in pkg. 1 Package weight(lbs) 0.70000000000000007 Returnability Y Country of origin FR Offer Sustainability Sustainable offer status RoHS (date code: YYWW) Green Premium product Compliant - since 1002 - Schneider Electric declaration of conformity 2

Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and - - - - - - - Substance 2 Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 3

Dimensions Drawings Dimensions (1) Tapped entry for M16 x 1.5 (2) 2 elongated holes Ø 4.3 x 6.3 mm on 22 mm centres, 2 holes Ø 4.3 on 20 mm centres. (3) 2 x Ø 3 holes for support studs, depth 4 mm. 4

Mounting and Clearance Mounting with Cable Entry Position of Cable Gland (1) Recommended (2) To be avoided 5

Mounting and Clearance Mounting with Rotary Heads and Levers Type of Cam (1) Recommended (2) To be avoided 6

Mounting and Clearance Setting-up with Head ZCE01 and ZCE09 (1) Tightening torque (Min : 1) (Max : 1.5) (2) Tightening torque (Min : 0.8) (Max : 1.2) 7

Connections and Schema Wiring Diagram 2-pole NC + NO Snap Action 8

Technical Description Characteristics of Actuation Switch Actuation by 30 Cam 9

Technical Description Functionnal Diagram (1) Closed (2) Open (4) Tripping (5) Resetting is replaced by the following group of products: Miniature range ZCE01 limit switch head ZCE - without lever - spring return - left and right actuation Qty 1 Compact range ZCP21 limit switch body ZCP - compact - 1NC+1NO - snap action Qty 1 Compact range ZCPEP16 cable gland entry - M16 x 1.5 - for limit switch - plastic body Qty 1 Miniature range ZCY45 limit switch lever ZCY - thermoplastic roller lever variable length Qty 1 10

Reason for Substitution: end of life Substitution date: 01 January 2017 11