Customer Training Catalog Training Proposal. Training Description for Network Energy COMMERCIAL IN CONFIDENCE 1

Similar documents
Training Proposal for Network Energy Product Technology Training Project

Customer Training Catalog Course Descriptions Network Energy Product Technology Training

Low and medium voltage service. Power Care Customer Support Agreements

Electrical Equipment and Safety: Operation, Control, Maintenance and Troubleshooting

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Course Name: POWER ELECTRONICS Course Code: EE603 Credit: 4

UPS2000-G-(1 kva-3 kva) Quick Guide. Issue: 05 Date: HUAWEI TECHNOLOGIES CO., LTD.

ABB DRIVES SERVICE. Optimize your wind economy. Wind Converter Services

RCDD: 16 Inst: 15 Tech: 16 Cert. Trainer: 16

EE069: Electrical Engineering for Non-Electrical Engineers

HWP Protection Board

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

Automotive. Automotive Body and Repair

THREE PHASE FAULT ANALYSIS WITH AUTO RESET ON TEMPORARY FAULT AND PERMANENT TRIP OTHERWISE

Lithium-Ion Phosphate Energy Storage System PowerCube-X1 Operation Manual

FTS600P FTS800P FTS1200P

ELECTRICAL EQUIPMENT : TRANSFORMERS, INVERTERS, RECTIFIERS, UNINTERRUPTABLE POWER SYSTEMS, GENERATORS. UAE, Sharjah, Copthorne Hotel Sharjah

Electrical Controls. Syllabus

3KW Off-grid Solar Power System LFP Battery

User Manual G1 Solar MPPT Inverter Solar MPPT Charger English version..1

Power Protection Discrete Automation & Motion South Africa

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

COURSE: Power Generation and Economics DEPARTMENT: Electrical and Electronics Engineering ACADEMIC YEAR: COURSE CODE: 15EE42 SEMESTER: IV TOTA

L I T H I U M B AT T E R Y

PowerCube 1000 V300R005C00. Solution Description. Issue 03. Date HUAWEI TECHNOLOGIES CO., LTD.

User Manual / Manuel utilisateur

Huawei Network Energy, Powering the Future. Huawei UPS Solutions HUAWEI TECHNOLOGIES CO., LTD.

PART7. Trouble Shooting

Protection of Power Electronic Multi Converter Systems in AC and DC Applications

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

PowerCube 1000 V300R002C01. Solution Description. Issue 02. Date HUAWEI TECHNOLOGIES CO., LTD.

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

Power Conversion System The Best Technology for your photovoltaic and storage system

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

More power for railway lines Maximum efficiency with proven system behavior

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

User Manual 3KVA/5KVA 24V INVERTER / CHARGER. Version: 1.1

In any of the 5 star hotels. The exact venue will be informed once finalized.

Auto Service Technician

ADF. Restoring the perfect wave

SINAMICS GM150 IGCT version

Two-Stroke Diesel & X-DF Engines

CURRICULUM BOSCH-REXROTH (CENTRE OF EXCELLENCE) GANPAT UNIVERSITY

Engine Division Training Center

UPS5000-E (25-75 kva) Series

12. Troubleshooting Items to be checked first. Samsung Electronics

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

Customized drive solutions

TECHNICAL DATA SHEET KVA UPS Systemss

Operating Manual / / REV F

User Manual 1KVA-5KVA INVERTER / CHARGER

Training at its best

No Operation of air conditioner Explanation

Safety Precautions. IST5 Series User Manual kva

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Switchgear and Distribution Systems for Engineers and Technicians

Marine and Outdoor Power Equipment Technician Level 2

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Liebert NX8 User Manual +%`K6 UPS

Solar Hybrid Inverter SP Brilliant Series

User Manual. Axpert King 3.2KW/5.2KW 48V MPPT SOLAR INVERTER. Version: 1.0

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

Industrial Substation Maintenance April $4,250 Abu Dhabi. UAE

Eclipse Plus VA UPS and Surge Suppressor User s Manual

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Transforming Transforming Advanced transformer control and monitoring with TEC

PR1000ELCD / PR1500ELCD User s Manual

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Connection of F-DQ to F-DI of SINAMICS

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

MGE Galaxy PW kva 480 V. Operation

Low Frequency Pure Sine Wave Inverter. Operatinal Manual

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

TRAINING CATALOGUE 2018

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK.

Operating Manual

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

Installation & Operation Manual

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

PREVIEW ONLY - FULL COPY AVAILABLE TO CONSORTIUM MEMBERS. Escalator Specific Electrical Systems. Course 209 PARTICIPANT GUIDE

Electrical Power Systems 2014/15

.3 Section Waste Management and Disposal.

Sales Application Engineering Europe & Russia. Application Engineering Training. Course description and Curriculum

PREVIEW ONLY. Course 106 INSTRUCTOR GUIDE. HVAC Systems Introduction and Overview. Module 1: Overview of Rail Car HVAC and General Safety Procedures

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

Motor and Generator Training

HERMES power supply - short description -

9.1.4 Troubleshooting of Faults in LCD Screen

Installation Instructions

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Electrical Maintenance

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218

Driftsinstruks. Utopia kontroller feilkoder PCP-2HTE og PC-ART. Vi håper de får stor glede av et Novema kulde produkt!

Industrial PFC UPS System

EE042: Practical Power System Protection for Engineers & Technicians

Modular three-phase UPS system. DPA UPScale RI kw The modular UPS for customized solutions

Transcription:

Customer Catalog Proposal Description for Network Energy COMMERCIAL IN CONFIDENCE 1

Customer Catalog Proposal CONTENTS 1 Path... 3 1.1 Power Supply Path... 4 1.2 Data Center Facility Path... 5 1.3 UPS Path... 6 2 Programs... 7 2.1 Power Supply Programs... 8 2.1.1 Minishelter Operation and Maintenance... 8 2.1.2 Power3000 Operation and Maintenance... 10 2.1.3 PowerCube500 Operation and Maintenance... 12 2.1.4 PowerCube1000 Operation and Maintenance... 14 2.2 Data Center Facility Programs... 16 2.2.1 IDS1000 Container Data Center Operation and Maintenance... 16 2.2.2 IDS2000 Modular Data Center Operation and Maintenance... 18 2.2.3 Precision Air Conditioner Operation and Maintenance... 20 2.2.4 NetEco Management System Operation and Maintenance... 22 2.3 UPS Programs... 23 2.3.1 UPS Operation and Maintenance... 23 2.3.2 UPS Operation and Maintenance (Fast-Track)... 25 COMMERCIAL IN CONFIDENCE 2

1 Path Plan & Design Implement & Operate Improve Planning and Design Enterprise XX Design X d Operation and Maintenance XX Product Operation and Maintenance X d Advanced Technology XX Advanced Technology X d XX Product Operation and Maintenance (Fast-Track) X d HCNP-XX X d HCIE-XX X d XX Field Specialist X d Technology Foundation HCNA-XX X d COMMERCIAL IN CONFIDENCE 3

1.1 Power Supply Path Plan & Design Implement & Operate Improve Planning and Design Operation and Maintenance Minishelter Operation and Maintenance 1d Advanced Technology Power3000 Operation and Maintenance 4d PowerCube 500 Operation and Maintenance 1d PowerCube1000 Operation and Maintenance 4d Elective Guide The training programs in the path include Minishelter, Power3000, PowerCube500, PowerCube1000 products trainings. Operators and Maintainers, Managers are proposed to learn the technology foundation, operation and maintenance training programs respectively. COMMERCIAL IN CONFIDENCE 4

1.2 Data Center Facility Path Plan & Design Implement & Operate Improve Planning and Design Operation and Maintenance IDS1000 Container Data Center Operation and Maintenance 2d Advanced Technology IDS2000 Modular Data Center Operation and Maintenance 2d Precision Air Condition Operation and Maintenance 3d NetEco Management System Operation and Maintenance 2d Elective Guide The training programs in the path include IDS1000, IDS2000, air condition and NetEco products trainings. Operators and Maintainers, Managers are proposed to learn the technology foundation, operation and maintenance training programs respectively. COMMERCIAL IN CONFIDENCE 5

1.3 UPS Path Plan & Design Implement & Operate Improve Planning and Design Operation and Maintenance UPS Operation and Maintenance 5d Advanced Technology UPS Operation and Maintenance (Fast-Track) 2d Elective Guide The training programs in the path include UPS2000, UPS5000, UPS8000 products trainings. Operators and Maintainers, Managers are proposed to learn the technology foundation, operation and maintenance training programs respectively. COMMERCIAL IN CONFIDENCE 6

2 Programs Enterprise Network Energy Programs are designed as follows: Programs Level Duration (working days) Location Class Size Power Supply Product Programs Minishelter Operation and Maintenance Ⅱ 1 6~12 Power3000 Operation and Maintenance Ⅱ 4 6~12 PowerCube500 Operation and Maintenance Ⅱ 1 6~12 PowerCube1000 Operation and Maintenance Ⅱ 4 6~12 Data Center Facility Product Programs IDS1000 Container Data Center Operation and Maintenance IDS2000 Modular Data Center Operation and Maintenance Ⅱ 2 6~12 Ⅱ 2 6~12 Precision Air Conditioner Operation and Maintenance Ⅱ 3 6~12 NetEco Management System Operation and Maintenance Ⅱ 2 6~12 UPS Product Programs UPS Operation and Maintenance Ⅱ 5 6~12 UPS Operation and Maintenance (Fast-Track) Ⅱ 2 6~12 Level Description: Ⅰ: Basic Course Ⅱ: Intermediate Course Ⅲ: Advanced Course Ⅳ: Expert Course COMMERCIAL IN CONFIDENCE 7

2.1 Power Supply Programs 2.1.1 Minishelter Operation and Maintenance Path Minishelter Operation and Maintenance OPS11 Target Audience Lecture 1d Operators and maintainers Prerequisites Have a basic knowledge of Minishelter Objectives On completion of this program, the participants will be able to: Understand the basic structure of the Minishelter Master the principle, functional of Minishelter Master functions and parameters of the various components about Minishelter Master the installation of Minishelter Master the routine operation of Minishelter Master the routine maintenance of Minishelter Describe common faults of Minishelter Dispose common faults of Minishelter Content OPS11 Minishelter Operation and Maintenance Minishelter System introduction Minishelter product overview Minishelter hardware installation and operation Minishelter hardware installation and operation, norms and notes Minishelter working principle, structure, function Minishelter working principle Minishelter structure introduction Minishelter various components features the value of the integrated data center Minishelter maintenance and fault diagnosis How to obtain technical support help about Minishelter Minishelter basic knowledge about routine maintenance Minishelter basic knowledge about fault diagnosis Minishelter operation guidance about parts replacement Minishelter common fault diagnosis and treatment guidance 8

Duration 1 working day Class Size Min 6, max 12 9

2.1.2 Power3000 Operation and Maintenance Path Power3000 Operation and Maintenance OPS12 Lecture, Hands-on exercise 4d Target Audience Operators and maintainers Prerequisites Have a basic knowledge of power supply Objectives On completion of this program, the participants will be able to: Describe the function of Power3000 power supply system Describe the hardware structure of Power3000 power supply system Understand functions and parameters of the various components about Power3000 power supply system Understand the load capacity of Power3000 power supply system Master the installation of Power3000 power supply system, could complete some replace operation Master the routine operation of Power3000 power supply system Master the routine maintenance of Power3000 power supply system Describe common faults of Power3000 power supply system Dispose common faults of Power3000 power supply system Content OPS12 Power3000 Operation and Maintenance Power3000 power supply system introduction Power3000 power supply system product overview Power3000 power supply system hardware installation and operation Power3000 power supply system hardware installation and operation, norms and notes Power3000 power supply system site maintenance Power3000 power supply system site maintenance operation Power3000 power supply system parts replacement operation Power3000 power supply system maintenance and fault diagnosis How to obtain technical support help about Power3000 power supply system Power3000 power supply system basic knowledge about routine maintenance Power3000 power supply system basic knowledge about fault diagnosis Power3000 power supply system common fault diagnosis and treatment guidance Duration 4 working days 10

Class Size Min 6, max 12 11

2.1.3 PowerCube500 Operation and Maintenance Path PowerCube500 Operation and Maintenance OPS13 Lecture, Hands-on exercise 1d Target Audience Operators and maintainers Prerequisites Have a basic knowledge of power supply Objectives On completion of this program, the participants will be able to: Describe the function of PowerCube500 system Describe the hardware structure of PowerCube500 system Understand functions and parameters of the various components about PowerCube500 system Understand the load capacity of PowerCube500 system Master the installation of PowerCube500 system, could complete some replace operation Master the routine operation of PowerCube500 system Master the routine maintenance of PowerCube500 system Describe common faults of PowerCube500 system Dispose common faults of PowerCube500 system Content OPS13 PowerCube500 Operation and Maintenance PowerCube500 system introduction PowerCube500 product overview PowerCube500 hardware installation and operation PowerCube500 hardware engineering installation and operation, norms and notes PowerCube500 working principle, structure, function PowerCube500 working principle PowerCube500 structure introduction PowerCube500 various components features the value of the integrated data center PowerCube500 maintenance and fault diagnosis How to obtain technical support help about PowerCube500 PowerCube500 basic knowledge about routine maintenance PowerCube500 basic knowledge about fault diagnosis PowerCube500 operation guidance about parts replacement PowerCube500 common fault diagnosis and treatment guidance Duration 1 working day 12

Class Size Min 6, max 12 13

2.1.4 PowerCube1000 Operation and Maintenance Path PowerCube1000 Operation and Maintenance OPS14 Lecture, Hands-on exercise 4d Target Audience Operators and maintainers Prerequisites Have a basic knowledge of power supply Objectives On completion of this program, the participants will be able to: Describe the function of PowerCube1000 system Describe the hardware structure of PowerCube1000 system Understand functions and parameters of the various components about PowerCube1000 system Understand the load capacity of PowerCube1000 system Master the installation of PowerCube1000 system, could complete some replace operation Master the routine operation of PowerCube1000 system Master the routine maintenance of PowerCube1000 system Describe common faults of PowerCube1000 system Dispose common faults of PowerCube1000 system Content OPS14 PowerCube Solution Introduction PowerCube1000 system introduction PowerCube1000 system product overview PowerCube1000 system hardware installation and operation PowerCube1000 system hardware engineering installation and operation, norms and notes PowerCube1000 system site maintenance PowerCube1000 system site maintenance operation PowerCube1000 system parts replacement operation PowerCube1000 system maintenance and fault diagnosis How to obtain technical support help about PowerCube1000 system PowerCube1000 system basic knowledge about routine maintenance PowerCube1000 system basic knowledge about fault diagnosis PowerCube1000 system common fault diagnosis and treatment guidance Duration 4 working days 14

Class Size Min 6, max 12 15

2.2 Data Center Facility Programs 2.2.1 IDS1000 Container Data Center Operation and Maintenance Path IDS1000 Container Data Center Operation and Maintenance OIDS11 Lecture, Hands-on exercise 2d Target Audience Operators and maintainers Prerequisites None Objectives On completion of this program, the participants will be able to: Describe the basic architecture of the container DC Describe the basic concepts and features of the container DC Describe the typical configurations of the container DC Describe the values for consumer of the container DC Describe the technical advantages of the container DC Describe the application scenarios of the container DC Perform the engineering surveys of the container DC Describe the installation tools of the container DC Describe the installation precautions of the container DC Describe fastness and combination Describe the interconnect pipes of the container DC Describe the interconnect cables of the container DC Describe the System commission with power supply Describe the Inspections and checks of the container DC Describe the cooling system troubleshooting methods Describe the power supply system troubleshooting methods Describe the fire protection system troubleshooting methods Describe the room management system alarm processing methods Content OIDS11 IDS1000 Container Data Center Operation and Maintenance IDS1000 Container DC introduction DC basic concept and feature DC value Huawei DC s core technology and advantage DC application 16

IDS1000 Container DC installation Container DC survey Container DC installation precautions Container DC equipment installation tools Container DC fastness and combination Connecting pipe Connecting cable System commission with power supply IDS1000 Container DC routine maintenance Refrigeration system troubleshooting Power distribution system troubleshooting Fire protection system troubleshooting Computer room management system alarm processing Duration 2 working days Class Size Min 6, max 12 17

2.2.2 IDS2000 Modular Data Center Operation and Maintenance Path IDS2000 Modular Data Center Operation and Maintenance OIDS14 Lecture, Hands-on exercise 2d Target Audience Operators and maintainers Prerequisites None Objectives On completion of this program, the participants will be able to: Description modular DC basic components Description modular DC basic concept Description modular DC typical configuration Description modular DC value for consumer Description modular DC application scene Description modular DC installation tool Description modular DC installation notes Description modular DC combined cabinet Description modular DC fan installation Description modular DC UPS and UPS battery installation Description modular DC cable connection Description modular DC system power on debugging Description modular DC inspection Description modular DC UPS fault handle method Description modular DC fan fault handle method Description management system alarm handle method Content OIDS14 IDS2000 Modular DC Operation and Maintenance IDS2000 modular data center introduce Modular DC basic concept and features Modular DC basic components Modular DC typical configuration Modular DC value Modular DC core technology and advantage Modular DC application Modular DC technical specification IDS2000 Modular DC installation 18

Modular DC installation tool Modular DC installation notes Modular DC combined cabinet Modular DC fan installation Modular DC UPS and UPS battery installation Modular DC cable connection Modular DC power on and debugging IDS2000 Modular DC maintenance Modular DC routine maintenance Modular DC UPS fault handle Modular DC fan fault handle Modular DC management alarm handle Duration 2 working days Class Size Min 6, max 12 19

2.2.3 Precision Air Conditioner Operation and Maintenance Path Precision Air Conditioner Operation and Maintenance OIDS13 Lecture, Hands-on exercise 3d Target Audience Operators and maintainers Prerequisites Have the basic technology of data center facility Objectives On completion of this program, the participants will be able to: Description precision air conditioner basic technology Description precision air conditioner cooling principle Description Huawei main precision air conditioner products Description precision air conditioner main technical parameters Description precision air conditioner installation and debugging Precision air conditioner different type, cooling type, feature, and application scene Precision air conditioner different air supply method, feature, and application scene Description precision air conditioner type selection and configuration method Precision air conditioner design and heat load calculation Description precision air conditioner installation and debugging Description precision air conditioner on-site fault handle Description precision air conditioner routine maintenance Content OIDS16 Precision Air Conditioner Operation and Maintenance Precision air conditioner basic technology Temperature, humidity, press express and measurement Introduce cooling principle Introduce main parts and main parts function Introduce main parameters Introduce Huawei precision air conditioner products Precision air conditioner advanced technical training Precision air conditioner different type, cooling type, feature, and application scene Precision air conditioner different air supply method, feature, and application scene Precision air conditioner configuration method Precision air conditioner design and heat load calculation Precision air conditioner type selection method Precision air conditioner installation and debugging Precision air conditioner installation survey 20

Duration Precision air conditioner installation environment check Precision air conditioner indoor machine and outdoor machine installation Precision air conditioner pipe connection Precision air conditioner vacuum pumping and pressure test Precision air conditioner refrigerant charging Precision air conditioner power on and debugging 3 working days Class Size Min 6, max 12 21

2.2.4 NetEco Management System Operation and Maintenance Path NetEco Management System Operation and Maintenance OIDS14 Lecture, Hands-on exercise 2d Target Audience Operators and maintainers Prerequisites Have the basic technology of data center facility Objectives On completion of this program, the participants will be able to: Description of the NetEco networking mode Description of the NetEco function Description of the NetEco highlight Description of the NetEco data base installation Description of the NetEco software package installation Description of the NetEco configuration Content OIDS17 NetEco Management System Operation and Maintenance NetEco system introduction NetEco management system function highlight NetEco networking mode NetEco function NetEco highlight NetEco application scene NetEco installation NetEco data base installation NetEco software package installation NetEco hardware equipment installation NetEco configuration Equipment access Troubleshooting Duration 2 working days Class Size Min 6, max 12 22

2.3 UPS Programs 2.3.1 UPS Operation and Maintenance Path UPS Operation and Maintenance OUPS11 Lecture, Hands-on exercise 5d Target Audience Operators and maintainers Prerequisites Have a basic knowledge of electrician Objectives On completion of this program, the participants will be able to: Master the application scenarios and basic working principle of UPS product Master the Structure and components function of UPS product and Storage battery Master the installation and debugging points, site work content, attention matters of UPS product and Storage battery Master the basic Fault determination method and thought of UPS product and Storage battery Master the trouble diagnosis and treatment methods of UPS product Master the log analysis capabilities of UPS Master the commonly testing tools usage of UPS Master the commonly faulty judgment and processing of storage battery Content OUPS11 UPS Operation and Maintenance UPS system introduction Master the host of the panel in various states indicate characteristics The Model identification and Features of Fuse / fuses, resistors, capacitors, diodes, transistors, MOSFET, IGBT, and so on According to the LED, LCD display / voice to recognize (relays, transformers, buzzer, fan) / Charred flavor material appearance (batteries, transformers) / Machine and component temperature to identify potential problems Detection based on the phenomenon of online, offline, all the major components. Focus to master online detection method, to understand the general laws of the fault detection UPS parts replacement Manual maintenance bypass the conversion, and the machine exit The dismantling of Amplifier board Electrolytic capacitor discharge, DC FUSE dismantling IGBT module dismantling Fan dismantling 23

Commonly circuit board dismantling UPS testing tools usage The proper use of a multi-meter To measure host AC and DC output voltage zero ground voltage, zero fire voltage Focus on mastering the IGBT and power MOSFET and fuse / fuse detection The Mains state inverter Insertion of a battery switch Parameter measurements confirm to appropriate adjustment (output / charge voltage) Manual maintenance bypass Turn to the automatic bypass, debugging parallel machine systems UPS faulty judgment and processing of storage battery The Current Situation of storage battery industry To introduce common storage battery types and characteristics The working principle and application scenarios of various storage battery types The common failure case studies of storage battery Duration 5 working days Class Size Min 6, max 12 24

2.3.2 UPS Operation and Maintenance (Fast-Track) Path UPS Operation and Maintenance(Fast-Track) OUPS12 Lecture, Hands-on exercise 2d Target Audience Operators and maintainers Prerequisites Have a basic knowledge of electrician Objectives On completion of this program, the participants will be able to: Master the application scenarios and basic working principle of UPS product Master the Structure and components function of UPS product and Storage battery Master the installation and debugging points, site work content, attention matters of UPS product and Storage battery Master the basic Fault determination method and thought of UPS product and Storage battery Content OUPS12 UPS Operation and Maintenance(Fast-Track) UPS product introduction Basic knowledge of power supply and distribution Safety Basic knowledge UPS Product appearance and functionality introduction UPS Typical application scenarios Introduce the host within the plate member and the name of the device, functions of UPS UPS Common operating mode and various mode working principle Storage battery product and application scenarios introduction UPS installation and operations The installation and debugging points of UPS and Storage battery The Installation and maintenance process of UPS parallel operation Routine maintenance operations Duration 2 working days Class Size Min 6, max 12 25