ASSEMBLING THE 15 INCH FLUSH MOUNT TOUCH SCREEN DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN

Similar documents
Package Contents. Mounting Hardware

TRAC-Station BT Installation Instructions

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Aura CM-55i Flush Mount Illuminated Enclosure Installation Instructions

M670/M680BD MAGNALOCK SERIES Installation Instructions

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Installation Instructions for Series 3100V Low Level Indicator

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

GE Sensing & Inspection Technologies

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

SECURITY DOOR CONTROLS

Door Locking & Exit Hardware

Placing Security In YOUR Hands

SEN and SEN Outdoor Air Temperature Sensors

TS1 SMARTBOB REMOTE UNIT. INSTALLATION and OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Power Supplies DORMA PS

2904 Power Supply Installation Instructions I-EA00041

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

INSTALLATION MANUAL. Melink Corporation (513) Revision

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

USERS MANUAL MCD REMOTE OPERATOR

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS

Owner s Manual. Model 9300 Vehicular Slide Gate Operator

blocks Interconnection fuses &

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

5600 Series Power Operator Installation and Instruction Manual

SMP3CTX Series Power Supply/Charger

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

Electrical Options Booklet. Table of Contents

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

24HR 30A SPST TM SW. Features. Long Description

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

Sentinel Field Satellite Controller

MAPNET II Transceiver Installation Instructions

T57 SERIES LOW ENERGY OPERATOR INTRODUCTION FEATURES BENEFITS PATENTS TABLE OF CONTENTS

S450H 24V Hydraulic Swing Gate Operator

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Wall-Mount Server Rack with Built-in Shelf - Solid Steel - 8U

FES112 HIGH SECURITY ELECTRIC CUSTODIAL STRIKE INSTALLATION MANUAL

INQUIRY: HYROBOTICS CORP SAM LEE ( ) 5988 MID RIVER MALL DR. ST.CHARLES MO TEL : FAX :

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

AccuPower AQU128B Installation Instructions

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

V1504 Vertical Platform Lift OWNER S MANUAL

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

AC Powered. AC Powered. Model Installation/Owner s Manual. UL 325 Compliant. AC Powered Vehicular Swing Gate Operator

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

VA-7450 Series. Electric Valve Actuators

Electric strikes. An electric strike is an electromechanical device installed on the door frame allowing an electrical opening. Installation modes

AC Powered. AC Powered. Model Installation/Owner s Manual. AC Powered Vehicular Swing Gate Operator. UL 325 August 2018 Standard

24V 3A EN54 Ancillary Power Supply

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

Technical specification

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

Patient Care Facility

- 8 amp (200VA) - 8 amp (200VA) - Sixteen (16) Fuse Protected Outputs. - Sixteen (16) PTC Protected Outputs.

DC CCTV Power Supplies Installation Guide

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Pre-Installation Instructions

Combined Ventilation Controller RVWS-T-224HA

Series 1000 Room Temperature Sensors, 1K Ω Platinum (375α) RTD (MBC/RBC/MEC/UC)

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Jtec 489 UL489 Branch Circuit Breaker

Adams rite. Exit Devices & parts exit devices series exit device parts

Owner s Manual. Model 9310 Vehicular Slide Gate Operator

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

Installation and Operation Instructions DLP Series

Zodiac Max INSTALLATION MANUAL

!!!! ! Lock housing dimensions: 230mm L x 44mm W x 44mm D! Receptacle housing dimensions: 120m L x 44mm W x 44mm D. ! Surface mount housing for LK120

Fan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data

INSTALLATION MANUAL FOR

Owner s Manual. Model 9100 Vehicular Slide Gate Operator

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Adjustable Torque Controls

RETRO SOLUTIONS PRODUCT CATALOG

NMQB24-MFT, NMQX24-MFT Quick Proportional Control, Non-Spring Return, Direct Coupled, 24V, Multi-Function Technology

SHEAR ALIGNING MAGNALOCK MODEL SAM2-24 INSTALLATION AND OPERATING INSTRUCTIONS

Transcription:

DIMENSIONS OF THE 15 INCH FLUSH MOUNT TOUCH SCREEN 18 (457 mm) 12 39/64 (320 mm) 3 1/2 (89 mm) 1 13/32 (36 mm) 19 (483 mm) 3 5/8 (92 mm) 7/64 3 mm) 1 13/32 (36 mm) 23 53/64 (605 mm) 20 3/4 (527 mm) 12 3/4 (324 mm) 13 13/16 (351 mm) 21 7/32 (539 mm) 7/32 (6 mm) 7/32 (5 mm) 1 13/64 (30 mm) 26 13/64 (665 mm) 21 7/32 (539 mm) 2 53/64 (72 mm) 2 1/5 (64 mm) 2 1/5 (64 mm) Figure 1: Dimensions of the 15 Flush Mount Touch Screen A complete library of product information is available at: http://www.mircom.com/tx3 Mircom July 2015 Printed in Canada Subject to change without prior notice LT-6105 rev 1.1 Page 1 of 6

1 MOUNT THE ENCLOSURE 2 The surface mount enclosure mounts on the wall. Mount the enclosure right-side up (the Mircom logo on the door is on the bottom). You need: 6 fasteners appropriate for the wall that you are mounting the enclosure on. Keyhole Keyhole 1. Find a suitable location for the enclosure. You can mount the enclosure using the keyholes on the back, or the knockouts on the side, or both. 2. Using the enclosure as a template, trace an opening in the wall for the cutout with one side is aligned with the side of the wall stud. 3. Cut an opening in the wall 0.1 inch larger than the trace ensuring that one side is aligned with the wall stud or supporting structure. 4. Insert the enclosure into the wall cutout and using the side of the enclosure as a template mark the hole mounting locations (either keyholes or knockouts or both). 5. If you are using the keyholes, remove the enclosure and place 2 fasteners halfway into the wall into the marked keyhole locations. Then place the enclosure onto the top fasteners and lower it so that the fasteners fit in the narrow part of the keyholes. 6. Screw the other fasteners into the remaining holes or knockouts. 7. Tighten all fasteners into place. Figure 3: Front View Wall Frame Top Enclosure Figure 2: Location of the mounting holes Front Side View Figure 4: Side View LT-6105 rev 1.1 Page 2 of 6

Power Switch (on outside of door) AC or DC Door Strikes: Auxiliary Door Strike: 21 and 3 AC Door Strike or Maglock 4 2 18 AWG 3 NO NC Jumper JW8 Jumper JW8 NO NC TS8 AC Door Strike or Magnetic Lock AC or DC Power Supply for Door Strike For a door strike: connect the jumper wire to the top pin of jumper JW8 (normally open). AC or DC Power Supply for Door Strike TS8 DC Door Strike (Output 1) 18 AWG DC Output Door Strike or Magnetic Lock TS9 4 Auxiliary Door (Output 2) 18 AWG For a maglock: connect the jumper wire to the bottom pin of jumper JW8 (normally closed). The maximum supply for the AC or DC Power Supply for Door Strike must not exceed: 28 VAC / 1 A max 30 VDC / 1 A max Alternative Wiring for Dry Contact Warning: Turn the power off before wiring. Wiring Requirements Install all power supplies outside the enclosure. Unless specified otherwise, all wiring is a maximum length of 1000 ft (304.8 m). The RS-485 wiring maximum length is 4000 ft (1219.2 m). See LT-996 for power wiring lengths. The door strike power supply depends on the door strike power requirements. On/Off Switch TS9 - + Door Strike Note: Most door strikes are nonpolarity. + - Power Supply Note: If AC power supply is used, polarity does not apply. Jumper JW8 NO NC TS8 Trigger for door operator Jumper JW8 controls whether the contact is normally open or normally closed. Contact ratings for outputs 2-4: 125 VAC / 2 A 30 VDC / 1 A LT-6105 rev 1.1 Page 3 of 6

Camera Supply 5 6 8 Address 1 DIP SWITCH SETTINGS FOR RS-485 Address 2 Address 3 Address 4 ON OFF 1 8 1 8 1 8 1 8 Each Touch Screen must have a unique RS-485 address. Use DIP switches 1-6 to set the RS-485 network address. See LT-969 for details. Phone Lines: 8 SW1 DIP Switches TS3 Camera Power Supply (12 VDC) Phone Lines Line 1 T R T R Line 2 (optional) P7 Guard Phone board connector P5 TX3-IP Module Connection P4 TX3-MDM Modem board connector 7 Postal Lock (Input 1) Fire Alarm Override (Input 2) Door Contact (Input 3) 22 AWG Non-configurable PBX systems are not supported. For more information, contact Mircom technical support at 1-888-647-2665. Warning: Turn the power off before wiring. USB connector: Connect to computer for firmware upgrade and configuration (maximum length of USB cable: 8 ft/2.4 m) Postal Lock: RS-485: 7 9 6 On/Off Switch Camera Supply: TS5 Postal Lock Warning: Do not attach the wiring until after the postal lock is installed. Fire Panel Activation of this input Door relocks the main door Contact (Output 1). Activation of this input unlocks the main and auxiliary doors (Outputs 1 and 2). LT-6105 rev 1.1 Page 4 of 6

9 RS-485 10 GROUND 22 AWG Maximum length: 4000 ft (1219.2 m) Panel 1 First panel on network Panel 2 Panel 3 Last panel on network 1. Make sure that the power is off. 2. Attach one end of a 16 AWG or larger wire to the ground terminal and connect the other end to the site ground (water pipe). Power Switch (on outside of door) 120 Ω 120 Ω Optional common reference connection if available Connect shield to chassis ground on one panel only Ground (16 AWG or larger) To MD-990 24 VDC power supply (not polarity sensitive) Figure 5: Chassis Ground and Power LT-6105 rev 1.1 Page 5 of 6

11 12 MOUNTING THE MD-990 24 VDC, 156 W POWER SUPPLY Overall dimensions including door: height: 7 23/32 (196 mm) width: 9 53/64 (250 mm) depth: 2 37/64 (66 mm) Knockout dimensions: 1 1/8 (29 mm) and 7/8 (22 mm) CONNECTING THE POWER 1. Connect the MD-990 load power supply wires to the Touch Screen terminal screws as shown in Figure 5. 2. Connect the building power supply wires to the MD- 990 line terminal screws as shown in Figure 8. 3. Connect the other end of the building power supply wires the line voltage terminals. 4. Turn the power on. 7 3/4 (197 mm) Screws To building power { To Touch Screen { 7 1/5 (191 mm) Figure 7: Power Supply Enclosure 9 1/5 (241 mm) 3 (76 mm) Figure 6: Power Supply Enclosure Dimensions To surface mount the power supply enclosure: 1. Find a suitable location for the power supply enclosure, such as over a wall stud. 2. Using the power supply enclosure as a template, mark the back mounting hole locations as indicated in Figure 7. Ensure that at least one side is over a wall stud. 3. Remove the power supply enclosure and place the top two screws halfway into the marked hole locations and wall stud. 4. Place the power supply enclosure onto the two screws. 5. Screw the other two screws into the remaining holes. 6. Tighten all four screws into place. The enclosure can also be mounted directly onto the drywall using anchors. Figure 8: Terminal block wiring LT-6105 rev 1.1 Page 6 of 6