VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

Similar documents
Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Series VENTS OVK. Low pressure axial fans in the steel casing with the air. for wall mounting.

Series VENTS OVК. Axial fans of low pressure in steel case with the efficiency. wall-mounted assembly.

VENTS ТТ. Series. In-line mixed-flow fans in plastic casing with the air capacity up to 2350 m 3 /h. FANS FOR ROUND DUCTS

SMOKE EXTRACTION VENTILATION FOR PARKING PREMISES

IN-LINE CENTRIFUGAL DUCT FANS VT Series

KV sileo 100 M. Circular duct fans. Circular duct fans

Sentinel D-Box Single Fan

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Sentinel D-Box Twin Fan

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

MegaBox Product-specific information

Single-inlet centrifugal fans

CK, LPK, LPKB. Duct fans with circular connection.

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

AC Commercial Fans Edition. ErP ready

NEW Acoustic In-Line Fans (ACQ)

Circular Duct Fan prioair

GigaBox centrifugal fans Product specific information

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

NEW Slimpak EC Box Fan (SLPT EC)

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

CENTRIFUGAL IN-LINE FANS VENT Series

Suitable For: Bathroom Living Area Whole House Ventilation Duct Boosting Hydroponic Growing General Ventilation

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

TWINFLOW STDR Product Brochure

USER S MANUAL VENTS OV/ OVK/ OV1/ OV1 R/ OVK1/ VKF/ VKOM / OVP

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

Ceiling swirl diffusers with perforated face plate

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

SILENT MV Ultra Quiet In-line Fans

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

BDB DIDW CENTRIFUGAL FAN with Backward Wheel TYPE X TYPE T

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

Wall mounted fan

F a n t y p e s J K K - J K K

ROOFMASTER STEF-HT ROOF FAN

BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

Air Flow Solutions. Commercial Fans Offices, retail, leisure, education

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Energy-saving motors (ESM)

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

Mechanical mixing box MBM

ROOF FAN ROOFMASTER STEC

Inline Fans Options Featuring TD-MIXVENT/TD-SILENT

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

ROOFMASTER STEF-HT ROOF FAN

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CMP/EW EFFICIENT WORK

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Multi-Port Centrifugal Fans for Round Duct

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

ROOFMASTER STEF-ATEX ROOF FAN

NCF fans 50 Hz. Protection class IP 55

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

CMR/EW EFFICIENT WORK

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

supplied in Form (B) configuration. Airflow over Impeller- Motor.

In-line rectangular fans. Technical Catalogue

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

IN-LINE NORMALIZED ELECTROPUMPS in cast iron

TKC, TKS, TKV/TKH Roof fans

Product Data Sheet 4118 N/ The engineer's choice

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

HIGH TEMPERATURE TWIN SQUIF FANS

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

7/S5 FIRE DAMPER FD40. v 2.9 (en)

Sabre Plate Mounted Sickle Fans (VSP)

Sound attenuators, Sound attenuating louvres

Transcription:

SOUND-INSULATED FANS Series Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7 m 3 /h Purpose KSB fan design allows to use them in supply and exhaust ventilation systems in premises with high requirements to the noise level and with limited space for mounting. For example, the unit design includes a possibility of space-restricted installation above suspended ceilings. They are designed for mounting into Ø - mm air ducts. Design The fan casing is made of aluzinc. For easy installation and operation, the top cover of the fan is secured with a special lock. Warm and sound insulation is made of non-combustible mineral wool mm thick. To ensure better noise absorption, the inner surface of the insulation is made of a perforated metal sheet. The round connecting spigots are rubber sealed. Motor The fans are equipped with asynchronous motors with an external rotor and centrifugal impellers with backward curved blades. The motors are equipped with an integrated overheating protection with automatic restart. The use of ball bearings with specially selected lubricating oil guarantees low noise and makes the fan completely maintenance-free. Speed control The control can be either smooth or stepped and carried out with a thyristor or autotransformer regulator. Several fans can be connected to one controller, provided that the total power and operating current do not exceed the nominal parameters of the controller. Mounting Inline fans are designed for round air ducts. The fans are installed at an air duct junction. The use of flexible connectors requires fixation of the fan on the building structure by means of supports, mounts, or fixing brackets. The fan can be fixed in any position, taking into account the air flow direction indicated by the arrow on the fan casing. While mounting the fan provide enough access for servicing and repair operations. Designation key Series Spigot diameter Modification Motor Options VENTS KSB, 125,, 16,, 2, 315, 355,,, K2: heat- and soundinsulated casing S: high-powered motor; B: low noise modification R: power cable with IEC C14 plug Accessories

WWW.VENTILATION-SYSTEM.COM Overall dimensions Dimensions [mm] Model D B B1 H L L1 L2 Weight [kg] KSB K2 99 42 228 258 517 7 414 13 KSB 125 K2 124 42 228 258 517 7 414 13 KSB 125 K2 S 124 533 333 28 63 617 525 19 KSB K2 149 47 278 282 566 586 493 17 KSB 16 K2 159 47 278 282 566 586 493 17 KSB K2 198 535 357,5 355 632 628 535 22.6 KSB 2 K2 248 677 537 429 774 759 666 33 KSB 315 K2 S 313 76 56 46 857 747 666 48 KSB 355 K2 354 83 641 927 885 84 58 KSB K2 399 927 737 578 124 957 876 78.5 KSB K2 449 149 858 67 1152 149 968 84 KSB K2 499 123 993 724 1 1263 1182 123 L1 L H B B1 L2

SOUND-INSULATED FANS KSB K2 KSB 125 K2 KSB 125 K2 C KSB K2 Unit voltage [V/ Hz] 1~ 23 1~ 23 1~ 23 1~ 23 Power [W] 58 61 88 84 Current [A].25.28.37.37 Maximum air flow [m 3 /h] 285 33 484 485 RPM [min -1 ] 253 256 267 262 level at 3 m distance [dba] 34 35 4 38 Transported air temperature [ C] -25 up to +55-25 up to +55-25 up to +55-25 up to +55 Ingress protection rating IPX4 IPX4 IPX4 IPX4 SEC class C C C C KSB K2 KSB 125 K2 2 2 2 2 6 55 KSB K2 7 6 55 KSB 125K2 45 45 4 2 4 2 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 62 48 57 6 52 48 42 42 32 42 52 L wa to outlet dba 79 74 76 72 58 51 53 44 59 69 L wa to environment dba 54 4 44 42 41 39 39 34 44 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 63 49 57 61 52 48 42 42 33 43 53 L wa to outlet dba 81 66 76 78 73 6 52 54 45 61 71 L wa to environment dba 55 41 45 51 51 43 42 4 39 35 45 6 7 KSB 125 K2 S 6 KSB K2 95 KSB 125K2 S 9 85 8 75 7 6 9 KSB K2 85 8 75 7 6 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 71 56 7 6 55 48 48 37 51 61 L wa to outlet dba 88 72 83 85 8 57 59 68 78 L wa to environment dba 6 43 52 58 53 44 42 4 4 4 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 7 55 64 68 59 54 47 47 37 6 L wa to outlet dba 86 71 81 83 78 64 55 58 49 66 76 L wa to environment dba 59 42 57 52 43 41 39 39 38 48

WWW.VENTILATION-SYSTEM.COM KSB 16 K2 KSB K2 KSB 2 K2 KSB 315 K2 S Unit voltage [V/ Hz] 1~ 23 1~ 23 1~ 23 3 ~ 38 Power [W] 86 164 32 4 Current [A].38.71 1.4 1.1 Maximum air flow [m 3 /h] 77 1515 27 RPM [min -1 ] 267 258 2615 26 level at 3 m distance [dba] 38 42 45 48 Transported air temperature [ C] -25 up to +55-25 up to +55-25 up to +55-25 up to +55 Ingress protection rating IPX4 IPX4 IPX4 IPX4 SEC class C C - - 7 9 6 KSB 16 K2 8 KSB K2 7 6 6 7 8 95 9 KSB 16 K2 85 8 75 7 6 18 17 KSB K2 16 14 13 12 11 6 7 8 [dba], 9 8 KSB 2 K2 7 6 6 8 1 1 16 Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 7 55 64 68 59 54 47 47 37 6 L wa to outlet dba 87 72 83 84 79 56 59 49 67 77 L wa to environment dba 58 42 57 52 43 42 39 39 38 48 [dba], 1 1 KSB 315 K2 S 1 9 8 7 6 1 2 Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 73 57 67 71 61 57 49 49 38 53 63 L wa to outlet dba 81 67 77 78 74 6 52 54 46 61 71 L wa to environment dba 62 39 46 62 51 45 45 35 34 42 52 36 34 KSB 2 K2 32 28 26 24 22 6 8 1 1 16 7 68 66 KSB 315 K2 S 64 62 6 58 56 54 52 1 2 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 77 6 7 75 64 59 52 52 4 56 66 L wa to outlet dba 81 67 77 79 74 6 52 55 46 61 71 L wa to environment dba 46 6 63 55 48 33 33 34 45 55 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 87 8 83 81 77 7 66 64 62 66 76 L wa to outlet dba 9 8 8 79 83 81 83 8 76 69 79 L wa to environment dba 68 55 56 67 58 53 52 53 48 58

SOUND-INSULATED FANS KSB 355 K2 KSB K2 KSB K2 Q Unit voltage [V/ Hz] 1~ 23 1~ 23 1~ 23 Power [W] 22 349 473 Current [A].89 2. 2.35 Maximum air flow [m 3 /h] 2235 286 276 RPM [min -1 ] 133 138 1 level at 3 m distance [dba] 48 48 48 Transported air temperature [ C] -25 up to +55-25 up to +55-25 up to +55 Ingress protection rating IPX4 IPX4 IPX4 SEC class - - - 8 7 7 KSB 355 K2 6 KSB K2 6 1 1 2 22 21 KSB 355K2 19 18 17 16 14 13 12 1 41 KSB K2 39 37 33 31 29 1 2 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 78 61 72 77 66 61 53 53 41 58 68 L wa to outlet dba 83 68 78 8 76 61 53 56 47 63 73 L wa to environment dba 68 52 66 64 47 41 32 33 33 48 58 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 84 66 78 83 71 66 57 57 44 64 74 L wa to outlet dba 9 74 85 87 82 66 58 6 51 69 79 L wa to environment dba 69 63 64 54 46 34 35 35 48 58 8 7 KSB K2 Q 6 1 2 48 KSB K2 Q 46 44 42 38 1 2 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 8 63 74 79 68 63 54 55 42 6 7 L wa to outlet dba 87 72 83 84 79 56 59 49 67 77 L wa to environment dba 69 56 66 53 51 42 4 35 48 58

WWW.VENTILATION-SYSTEM.COM KSB K2 ( ) KSB K2 (Y) Unit voltage [V/ Hz] 1~ 23 3 ~ 38 Power [W] 73 78 Current [A] 2.82 1.6 Maximum air flow [m 3 /h] 7 672 RPM [min -1 ] 98 948 level at 3 m distance [dba] 56 54 Transported air temperature [ C] -25 up to +55-25 up to +55 Ingress protection rating IPX4 IPX4 SEC class - - 6 6 KSB K2 ( ) KSB K2 (Y) 6 7 6 7 8 7 KSB K2 ( ) 7 6 6 5 6 7 8 7 6 5 KSB K2 (Y) 6 7 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 87 69 8 86 74 68 59 59 46 67 77 L wa to outlet dba 92 76 88 9 84 69 6 62 52 72 82 L wa to environment dba 76 68 75 67 52 48 46 4 56 66 [dba], Hz 63 125 2 8 LpA, 3 m [dba] LpA, 1 m [dba] L wa to inlet dba 85 66 78 83 71 66 57 57 44 64 74 L wa to outlet dba 9 75 86 88 83 67 58 61 51 7 8 L wa to environment dba 74 66 73 51 49 47 45 39 54 64