52
SILENCE 54 ASO 55 ROBUST 56 AIRPACK 57 MONO 58 Frequency Converter 59 Accessories 6 www.leister.com General Catalog Process Heat 53
SILENCE: The quieter option. No blower no air! In industrial processes one blower can often supply several air heaters in parallel. Our durable and maintenance-free blowers are a result of uncompromising quality standards and decades of experience. The mid-range blower SILENCE is very quiet during operation at 61 db(a). It delivers high air flows and can be installed in all orientations. Medium pressure blower SILENCE Technical data SILENCE Design: radial blower Frequency Hz 5 6 Air flow (68 F ) cfm 166 212 Static pressure psi.15.2 Max ambient temperature F 14 14 Max. air inlet temperature F 392 392 Noise emission level db(a) 61 61 Environmental protection (IEC 6529) IP 54 IP 54 Outside diameter air inlet in 3.15 3.15 Outside diameter air outlet in Weight lbs 19.8 19.8 Mark of conformity 2 2 Protection classe l 1 1 Installation dimensions in inches Ø 6 Voltage V~ 5Hz 1 23 3 23 / 4 6Hz 3 44 48 Power consumption W 25 25 Without cable Order no. 13.57 9.84 ft cable / Euro plug Order no. 13.51 Ø 4.88 124 Ø 8 3.15 Ø 11.2 28 Additional versions available on request.27 6.8 3.15 8 Ø.27 6.8 4 7 2.4 52 4 7 11.4 28 289 11.37.23.2 M2 x M2 x 38 3.93 1 12.47 34 1.33 11 4.33 2.48 63 68 2.67.17.14.11.9.6.3 14 5.51 154 6.6 26 1.23 35 7 16 141 176 212 at 68 F / 14.7 psi Air flow [ cfm]! Accessories page 6 www.leister.com 54 General Catalog Process Heat
ASO: The air flow giant. At, the ASO delivers 56 cfm. When used with the appropriate accessories it can supply several Leister air heaters in parallel. Medium pressure blower ASO Technical data ASO Design: radial blower Frequency Hz 5 6 Air flow (68 F ) cfm 476 56 Static pressure psi.23.35 Max ambient temperature F 14 14 Max. air inlet temperature F 392 392 Noise emission level db(a) 7 7 Environmental protection (IEC 6529) IP 54 IP 54 Outside diameter air inlet in 5.28 5.28 Outside diameter air outlet in 3.54 3.54 Weight lbs 33.1 33.1 Mark of conformity 2 2 Protection classe l 1 1 Installation dimensions in inches Ø 9 3.546 Voltage V~ 5Hz 1 23 3 23 / 4 6Hz 3 44 48 Power consumption W 55 55 Without cable Order no. 13.527 9.84 ft cable / Euro plug Order no. 13.53 Ø 138 5.437 Ø 5.28 134 Additional versions available on request.2767 9 3.546 1.773 45 132 5.2 Ø 2767 3.94 1 1.162 29.5 14.66 357.3 3.74 2.9 94 24 8.38 1.773 45.36.29 14.49 368 M2 M2 x x 38 116 4.57 71 2.797.22.15.479 12.16 112 4.413 4.58 13.7 222 8.747 242 9.535 7 141 212 282 353 424 494 565 365 14.381 at 68 F / 14.7 psi Air flow [ cfm]! Accessories page 6 www.leister.com General Catalog Process Heat 55
ROBUST: The name speaks for itself. Very compact design with enormous power. Thanks to the efficient sound insulation it is very quiet, can be installed in all orientations and is virtually indestructible even under extreme conditions and continuous operation. High pressure blower ROBUST Technical data ROBUST Design: regenerative blower Frequency Hz 5 6 Air flow (68 F ) cfm 42 46 Static pressure psi 1.16 2 Max. ambient temperature F 14 14 Max. air inlet temperature F 14 14 Noise emission level db(a) 62 62 Environmental protection (IEC 6529) IP 54 IP 54 Outside diameter air inlet in Outside diameter air outlet in Weight lbs 17.6 17.6 Mark of conformity 2 2 Protection classe l 1 1 Installation dimensions in inches 1.497 38 1.24 26 Voltage V~ 5Hz 1 12 1 23 3 23 / 4 6Hz 3 44 48 Power consumption W 25 25 25 Without cable Order no. 13.434 13.429 9.84 ft cable / Euro plug Order no. 13.432 8.77 221 M2 x M2 x 38 2.482 63 Additional versions available on request 1.891 48 1 3.94.473 12 5.516 14 6.68 154 1.182 46 1.7 Ø 22 7.959 Ø 124 4.886 146 5.752 1.2.9.6.276 7 8 3.152.3 2.837 72 1.339 34 Ø.2767 1.47 255 21 3 42 5 at 68 F / 14.7 psi Air flow [cfm]! Accessories page 61 www.leister.com 56 General Catalog Process Heat
AIRPACK: The full pressure provider. If high air pressure is required, the AIRPACK is the answer! It is used wherever large air volumes at high pressure are required. Its impressive power means it can supply several LEISTER air heaters in parallel. The AIRPACK delivers sufficient pressure to efficiently supply Leister blow-off nozzles. High pressure blower AIRPACK Technical data AIRPACK Design: regenerative blower Frequency Hz 5 6 Air flow (68 F) cfm 138 159 Static pressure psi 4.35 4.35 Max. ambient temperature F 14 14 Max. air inlet temperature F 14 14 Noise emission level db(a) 73 73 Environmental protection (IEC 6529) IP 54 IP 54 Outside diameter air inlet in Outside diameter air outlet in Weight lbs 57.3 57.3 Mark of conformity 2 2 Approval mark 3 3 Protection classe l 1 1 Installation dimensions in inches 14.33 364 12.873 327 7.874 2 Voltage V~ 5Hz 3 23 / 4 6Hz 3 44 48 Power consumption W 22 Without cable Order no. 119.358 Additional versions available on request 2.165 55 Ø 6 4 4.728 12 1.236 26 12.637 321.11 2.7 13.543 344 4.4 Ø 6 M25 x M25 x 38 Ø 16 6.929 3.6 2.9 2.2 7.913 21.5 Ø.59 15 3.37 84 6.141 156 8.465 215 25.98 14.724 374 35 7 16 14 175 at 68 F / 14.7 psi Air flow [cfm]! Accessories page 61 www.leister.com General Catalog Process Heat 57
R.32 MONO: Compact with high performance. In spite of its small size, this blower delivers an impressive air volume of 32 cfm and a static pressure of.73 psi. With its maintenance-free, brushless motor, it is suitable for used for continous operation. The compact MONO blower can easily be mounted in confined spaces. High pressure blower MONO Technical data Frequency Hz 5 / 6 Air flow (68 ºF) cfm 32 Static pressure psi.73 Mains switch Device protection Max. ambient temperature F 14 Outside diameter air outlet in Weight with 3 m cable lbs 2.65 Mark of conformity 2 Protection classe II 4 Installation dimensions in inches Voltage V~ 23 12 Power consumption W 23 23 Plug Euro US-plug (pol.) Order no. 132.869 141.41 9.53 8.86 2.76 2.13.22.9 3.7 2.16.22 3.33 9.53 2.6 max. 4.25 5.16 5.51 Pressure [kpa].75.6.45.3 /.15 7 14 21 28 35 at 68 F / 14.7 psi Air flow [cfm]! Accessories page 6 www.leister.com 58 General Catalog Process Heat
Frequency converters: More power for your blower. Because air volume and heating performance can be set independently, precisely and reproducibly from each other, frequency converters FC 55 and 22 improve your hot air processes. They let blowers turn faster than the mains frequency and reduces therefore the system costs. Frequency converters FC 55 / FC 22 Technical data FC 55 FC 22 Input voltage V~ 1 2 24 3 38 48 Max. blower rated power W 55 22 Frequency Hz 5 / 6 5 / 6 Typical input current at full load A 8.1 11.9 Output rated power (1%) A 3. 9.6 Weight lbs 2.2 4.6 Mark of conformity 2 2 Approval mark Protection classe I 1 1 Order no. 117.359 118.242 Installation dimensions in inches FC 55 (FC 22) 2.95 (3.93) 2.51 (3.19).43 5.51 (9.44) 6.6 (1.15) pressure [kpa].35 2.4.32 2.2.29 2. max. 8 Hz.26 1.8.23 1.6.2 1.4.17 1.2.14 1..11.8 SILENCE 7 Hz.9.6 4 Hz.6.4 3 Hz.3.2 min. 2 Hz 1 35 2 7 3 16 4 141 5 176 6 212 7 247 8 282 Air flow [l/min] Air flow [cfm] Pressure [kp].36 2.5 max..29 2..22.15 1. 4 Hz ASO.7.5 3 Hz min. 2 Hz 2 7 4 141 6 212 8 282 1 353 12 424 14 494 16 565 Air flow [l/min] Air flow [cfm] 5.7 (6.81) ROBUST AIRPACK 12. 1.7 4.4 (without) 5.62 (9.6)) 4.9 (without) Pressure [kpa] 1. max. 8. 1.2 6..9 4 Hz 4..6 3 Hz 2..3 min. 2 Hz 3.6 2.9 2.2.7 3 6 21 9 3 12 42 15 Air flow [l/min] Air flow [cfm] 35 7 16 14 75 Air flow [cfm] www.leister.com General Catalog Process Heat 59
Accessories SILENCE (Ø in) Accessories ASO (Ø 3.54 in) 17.288 PVC air hose in 17.237 PVC air hose 3.54 in 17.287 Hose clip for in air hose 17.236 Hose clip for 3.54 in air hose 17.24 Closing cap in attacheable to hose connection adaptor 17.238 and 17.278 17.239 Stainless steel filter, push-fit on air intake 17.294 Stainless steel filter, push-fit on air intake 111.771 Motor capacitor 23 V 11.887 Motor capacitor 23 V 17.238 3.54 Hose connection adaptor, Push-fit 17.291 Hose connection adaptor with 1 air outlet for in hose. 17.278 Hose connection adaptor, 17.292 17.293 Hose connection adaptor with 2 air outlets for in hose. Hose connection adaptor, Push-fit on adaptor 17.292 Accessories MONO (Ø in) 133.67 Holder 17.295 17.296 2.44 2.44 Hand operated air flow adjuster and on/off switch. Size 8.43 3.46 5.24 in Air flow off/on switch The air flow is interrupted on command (pneumatic 72.5 psi) to the heaters. Size 8.43 3.46 5.24 in 124.53 17.288 17.286 b a External air hose connection adaptor a = 2.52 in, b = in PVC air hose, in Special nozzles on request If using non-leister blowers or accessories, Leister does not provide any warranty for its products. www.leister.com 6 General Catalog Process Heat
The combination of blow-off nozzles and blowers allows fast and efficient drying of beverage bottles. Accessories ROBUST (Ø in) Accessories AIRPACK (Ø in) 17.35 PVC air hose,.748 in 17.287 Hose clip for ø and in air hose 17.29 Hose clip for.748 in air hose 17.241 Closing cap in push-fit on hose connection adaptors 17.292 and 17.293 17.242 Closing cap.748 in attacheable to hose connection adaptor 17.298 PVC air hose, in 17.288 17.354 18.623 14.17 17.298.78.78 Stainless steel filter push-fit on air intaker Motor capacitor 23 V~ Motor capacitor 12 V~ Hose conncetion adaptor, push-fit on ROBUST blower and adaptor 17.293 for hose connection 17.24 17.291 Closing cap in, push-fit on hose connection adaptors 17.278 Hose connection adaptor with 1 air outlet for in hose. 17.281 Hose connection adapter ( in), 3 outputs, each.55 in 17.292 Hose connection adaptor with 2 air outlets for in hose. 17.286 PVC air hose, in 17.278 Hose connection adaptor, 17.287 17.241 17.293 18.755 7 Hose clip for and in air hose Closing cap in push-fit on hose connection adaptors 17.292 and 17.293 Hose connection adaptor, push-fit Hand operated air flow adjuster and on/off switch. Size 8.43 3.46 5.24 in 11.895 125.97 125.98 a Stainless steel filter push-fit on air intaker Blow-off nozzle, push-fit Outlet opening adjustable.39.217 in a = 11.81 in a = 19.69 in Connector in 17.296 17.299 7 Air flow off/on switch The air flow is interrupted on command (pneumatic 72.5 psi) to the heaters. Size 8.43 3.46 5.24 in Special nozzles on request If using non-leister blowers or accessories, Leister does not provide any warranty for its products. www.leister.com General Catalog Process Heat 61